PROTECT C 3000 WD

Single phase UPS

Rugged & reliable systems


Qualified for windmills applications

Uninterruptible power security for critical


applications, including windmills control
and lighting systems.
FEATURES BENEFITS
Protect C series is a range of online double
conversion Uninterruptible Power Supply • VFI topology (online / double conversion) • Reduced OPEX: easy and economical
(UPS) securing power for essential loads. protection against all mains network maintenance thanks to the hot
problems swappable battery, which allow
Protect C 3000 WD benefits of the consistent • Very wide input voltage window of replacement on-site
continued development of this well-proven 140 VAC to 276 VAC without stress on the
and highly reliable series and of AEG PS internal battery system and with a stable • Improved uptime: no downtime for
specific expertise in applications for windmills. output voltage regular battery maintenance over
The system is robust and highly reliable and • ECO Mode for high efficiency operation system lifetime
its technical specifications are fulfilling • Expansion slot for SNMP, potential free
demanding requirements to secure power for contacts, remote display • Seamless integration with windmill
critical applications at the heart of windmills • LED display supervisory systems (control, alarms,
operations: yaw control systems or turbine • Configuration options (password protected) battery test) thanks to embedded
obstruction lighting. via the operator terminal communications
• Internal hardware data logger with plain text
Typical applications display and date / time stamp • Easy maintenance: hot swappable
• Yaw control systems • Emergency power off on terminal block battery directly from the front panel
• Turbine obstruction lighting (potential-free)
• Backup power for all types of critical loads • Cold start
in remote environments • Auto-shutdown delay time settable up
to 60 s

Hot swappable battery


for easy and quick
maintenance.
Specifications
Power type rating 3000 VA 2400 W
UPS INPUT
Input voltage 208 VAC | 220 VAC | 230 VAC (Default) | 240 VAC
Voltage range without battery mode (load dependent) 140 – 276 VAC
Frequency (auto selection) 50 Hz / 60 Hz
Frequency range 40 – 70 Hz
Synchronization range ±1 – 10 % configurable, default ±6 %
Input power factor / THDi ≥0.99 / <4 %
Current consumption at nominal load (max.) 12,6 A
UPS OUTPUT
Rated output voltage (adjustable) 200 VAC | 220 VAC | 230 VAC (default) | 240 VAC ±1 %
Voltage waveform Sinusoidal
Output voltage distortion Linear load THDU <3 % (<4 % at low battery (11 VDC / battery)
Non-linear load THDU <5 % (<7 % at low battery (11 VDC / battery)
Frequency (selectable) 50 Hz / 60 Hz
Frequency in battery Free run mode 50 Hz / 60 Hz ±0.25 Hz
Nominal output current (At 230 VAC) 13 A
Overload response (Double conversion mode) <130 % for 12 s | 130 % – 150 % for 2 s | >150 % for 100 ms
(Battery mode) <130 % for 12 s | 130 % – 150 % for 2 s | >150 % for 100 ms
Crest factor 3:1
Short circuit response Inverter limits the current >150 % for 100 ms
STATIC BYPASS
Bypass input range User selectable +20/-20 % of nominal voltage (default +15/-20 %)
Frequency range 50 / 60 Hz ±1 – 10 % of nominal value, (default 5 %)
Overload capacity 100 – 110 % overload warning | 110 - 130 % for 5 min | 130 % – 150 % for 15 s | >150 % for 300 ms
BATTERY
Type Sealed, maintenance free, integrated, hot swappable, 12 V | 7,0 Ah VRLA
Rated voltage 96 VDC (8 battery blocks 12 V each)
Max recharge current 1.7 A
Battery management Automatic and manual battery test
COMMUNICATION
Interfaces RS232, dry contacts, slot for network communication card
GENERAL DATA
Efficiency (ECO+ mode) ≥96 %
Efficiency at nominal load (Double conversion mode) ≥91 %
Operating temperature range 0 – 40 °C
Storage temperature range -25 – +55 °C (without battery, with battery recommendation 0 – 25 °C)
Humidity 0 – 96 % (without condensation)
Operation altitude at nominal load Up to 2000 m at 0 – 40 °C
Up to 3000 m at 35 °C without derating
Product safety IEC 62040-1
EMC EN 62040-2 C2, EN 61000-3-2, EN 61000-3-3
Protection class IP20
Pollution degree PD 2
Acoustic noise (1 m distance) <50 dB(A)
Input and out connectors Terminals
Dimensions (net). W x H x D (mm) UPS 214 x 346 (w/cover) | 412 (terminal cover)
Dimensions (with packing) W x H x D (mm) 320 x 490 x 576
Weight approx. UPS incl. integrated battery 35 kg, with packing 37 kg
Shipment Mains input cord 1200 mm, output power cord 1200 mm, communications cable 1200 mm,
Operating & safety instructions
Conformity CE, ROHS

AEG Power Solutions


Approach your local AEG Power Solutions representative for further support. Contact details can be found on: www.aegps.com

AEG PS – Protect C 3000 WD – EN – 07/2020 V1 – The technical data in this document do not contain any binding guarantees or warranties. The contents herein serve informational purposes only
and are subject to change at any time. We will make binding commitments only upon receipt of concrete enquiries and customer notification of the relevant conditions. Due to the non-binding nature of
these terms, we assume liability neither for the accuracy nor completeness of the data provided herein. AEG is a registered trademark used under license from AB Electrolux.