A B C D E A B C D E

F FAUCET SHO SHOWER


GV GATE VALVE WC WATER CLOSET
FAU
CB
FD CV CHECK VALVE TFD TERRACE FLOOR DRAIN
1 1
WM WATERMETER SFD SHOWER FLOOR DRAIN
WC

WC FD HB HOSE BIBB CWL COLD WATER LINE

QUEEN

QUEEN
FD FLOOR DRAIN LAV LAVATORY
QUEEN QUEEN

LAV LAV

CB CATCH BASIN PVC POLYVINYL CHLORIDE


FAU KS DC DIGESTIVE CHAMBER PVCSP PVC SOIL PIPE
2 2
LAV WC FAU LAV
FD WC FD
LC LEACHING WELL PVCWP PVC WASTE PIPE
KS KITCHEN SINK PVCDP PVC DRAINAGE PIPE
SV SHOWER VALVE PVCDSP PVC DOWNSPOUT PIPE
CB
CB
RTA RUN THRU ABOVE PVCVSTR PVC VENT STACK
FAU KS
RTB RUN THRU BELOW THRU ROOF
3 3
P P-1 LEGENDS
005 SCALE: NTS

QUEEN
ALL PLUMBING SPECIFICATIONS HEREIN SHALL BE MADE IN ACCORDANCE

QUEEN
WITH THE RULE AND REGULATIONS OF THE LATEST EDITION OF THE
PHILIPPINE NATIONAL PLUMBING CODE, ALL NATIONAL AND MUNICIPAL
S.T.
LAWS, LOCAL ORDINANCES, REGULATIONS OF THE DEPARTMENT OF
HEALTH AND REQUIREMENTS OF UTILITY COMPANY CONCERNED.
4 4
THE LOCATION OF PIPES MAYBE TRANSFERRED WHENEVER REQUIRED FOR THE
PROPER EXECUTION OF OTHER TRADES PROVIDED, THAT SUCH CHANGES
CONFORMS WITH THE RULES AND REQUIREMENTS OF THE ARCHITECT.

5 5 ALL PIPE JOINTS SHALL BE MADE WATER TIGHT AND PROPERLY SEALED USING
CV GV Ø3" PVC PIPE TO
Ø3" PVC PIPE TO THE FOLLOWING:
MAIN DRAINAGE LINE
MAIN DRAINAGE LINE
· PVC PIPE SOLVENT CEMENT - FOR PVC PIPES & FITTINGS.
· TEFLON TAPE - FOR GALVANIZED IRON PIPES AND FITTINGS.
· CEMENT MORTAR - FOR CONCRETE PIPES.
P P-1 GROUND FLOOR WATERLINE LAYOUT P P-1 GROUND FLOOR DRAINAGE LAYOUT · GASKET CEMENT - FOR GALVANIZED IRON PIPES AND FITTINGS.
001 SCALE: 1:66.67 002 SCALE: 1:66.67
· OAKUM & PEG LEAD - FOR CAST IRON PIPES AND FITTINGS.

3000 MATERIALS TO BE USED FOR THE PIPING SYSTEM SHALL BE AS FOLLOWS:


3000
1000
MH
2000
MH
Ø150MM PVC PIPE · G.I.PIPES & FITTINGS FOR MAIN WATER SUPPLY LINES.
CO CO
· PVC PIPES & FITTINGS FOR IN HOUSE WATER SUPPLY RISER &
100

1000 2000 CONC. COVER


CONCRETE COVER WITH
W/ 10MM PRB HANDLE
400
Ø10MM PRB HANDLE BRANCHES.
WATER LEVEL
WATER LEVEL 80 240 80 · PVC PIPES AND FITTINGS FOR SOIL WASTE VENTS & STORM WATER
400 400
LINES (DOWNSPOUT).

50
· CONCRETE PIPE - THE STORM DRAINAGE LINES BELOW THE GROUND
80
1150

Ø150MM
PVC PIPE VENT PIPES SHALL EXTEND FROM THE TOP OF THE ROOF AT LEAST

SEE ACTUAL
DIMENSION
1500

OUTLET INLET
400

400

200MM FOR FLAT ROOFS AND 300MM FOR SLOPING ROOFS, ALL VTR
1750
2000

INLET
400
240
400

MH MH LEACHING OPENING MUST BE COVERED BY USING WIRE SCREEN.


DIGESTIVE CHAMBER
CHAMBER
MH
ALL HORIZONTAL PIPES SHALL MAINTAIN A MINIMUM SLOPE OF 41 PER FOOT
200

OUTLET
80

75
(12%).
150

PLAN
2% SLOPE> <2% SLOPE
Ø100MM PVC PLAN Ø100MM PVC
GRAVEL BEDDING NO ARTESIAN WELL SHALL BE DONE WITHIN A RADIUS OF TWENTY FIVE (25)
150

OUTLET PIPE INLET PIPE GRAVEL & SAND


SECTION METERS FROM THE PROPOSED SEPTIC VAULT.
SECTION
P P-1 DETAIL OF CATCH BASIN ALL PLUMBING WORKS HEREIN SHALL BE DONE BY COMPETENT PLUMBERS
004 SCALE: 1:111.111
UNDER THE DIRECT SUPERVISION OF A DULY REGISTERED MASTER
P P-1 SEPTIC TANK DETAILS PLUMBER.
003 SCALE: NTS

CIVIL ENGINEER: PROJECT OWNER: PROJECT TITLE: SHEET CONTENTS SHEET NO.

PROPOSED TWO-STOREY RESIDENTIAL HOUSE P1


AS SHOWN
--------------------- 2 7