9 10 11 12 13 14 15 16

Make the handrails


23190 7200
A A (775) 5650
X (1:20) lower at the place
Z (1:20)
A

of the box (width 500).

B X B
Z

See note 4
B

C C

(28500)
22970 7000 Working space
14870 for maintenance
min. 600 mm.
860 860
Pneumatics Gate 730 Gate
cabinet D

HHU Control
JB104 JB101 cabinet
Gate
860
(10000)

7200

350

E
Floor grating
(upper level)
JB105 JB102
(1400)

860 860
Gate 730 Gate A-A
(710) 5790 Recommended maintenance area F
Junction boxes
JB101, JB102, JB104 GATE
(1:50)
(28500) 600 270
(1:25)
22680
14870

760
1060 184
860 860
Gate 730 Gate

2033
G G

(1273)
HHU
Hydraulic E E

1208
unit

150

100
D D
(10000)

100
7200

400

H 120 H
HHU, JB105 200

15
(1:50) 380 270

380
HHU

200
860

160
1713
(1400)

860 860
B-B

(1333)
Gate 730 Gate 920
F F
D-D
J
(1000) 5500 Recommended maintenance area J
Note!:Gate can be changed

150
Note 1! Handrails are excluded 100
to left- or right-handed.

100
from filter delivery and they are
(28500)
therefore under customer's
Weight: 35 kg
19000 responsibility!

Note 2! Handrail dimensions in


3370
K this drawing are for separation of K
0 harrmik 07.06.2021 sakero 07.06.2021 harrmik 07.06.2021
people from the filter hazards.
1 harrmik 25.01.2022 sakero 25.01.2022 harrmik 25.01.2022
REV. NAME DATE NAME DATE NAME DATE
REVISION TEXT
PREPARED CHECKED APPROVED
Note 3! Handrail position STATUS UNITS SCALE SIZE
dimensions are minimum mm 1:100 A1
distances from filter due safe CUSTOMER PROJECT PHASE SITE NO.
HHU reach range and risk of spraying
(10000)

7000

media (1400 mm). Do not PROJECT NAME CUSTOMER DOCUMENT NO.


decrease these dimensions! REPLACED BY REPLACES LANGUAGE
L L
Note 4! Handrail positions, type EN
DOCUMENT TITLE
and height must comply with local
legistlation. Minimum height in
ARRANGEMENT DRAWING
European Union 1200 mm.

GATE = recommended safety gate


(1500)

1150
C-C EQUIPMENT NO. SAFETY HANDRAILS ARRANGEMENT
position
Gates included in delivery by FFP3512 62/68/74
PROJECT ID PLANT CODE PLANT UNIT CODE DOCUMENT TYPE COUNTING NO. REVISION SHEET OF SHEETS
default as loose items
M (3130) Recommended maintenance area 1 1 / 1 M
HHU = Hand Held Unit / Local THIS INFORMATION IS CONFIDENTIAL AND PROPRIETARY TO METSO OUTOTEC CORPORATION OR ITS SUBSIDIARIES ( METSO DOCUMENT ID
OUTOTEC ) AND IS PROTECTED BY TRADE SECRET, COPYRIGHT AND/OR OTHER LAWS. IT MAY NOT BE ACCESSED, USED,
control panel COPIED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF METSO OUTOTEC. ALL RIGHTS RESERVED. T-8160
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16