Is 4990 - 2024
Is 4990 - 2024
Indian Standard
ICS 79.060.10
 BIS 2024
FOREWORD
This Indian Standard (Fourth Revision) was adopted by the Bureau of Indian Standards, after the draft finalized
by the Wood and Other Lignocellulosic Products Sectional Committee had been approved by the Civil
Engineering Division Council.
Plywood for concrete shuttering works is a Boiling Water Proof (BWP) Grade plywood, preservative treated
and especially suited for use in concrete shuttering and form work. Concrete shuttering plywood is very
economic as it can be put to repeated use, depending upon the care taken during erection and dismantling. The
main requirements of such plywood are that it should be durable under alternate wetting and drying conditions,
its surface should be hard and it should possess adequate strength to withstand the load of concrete and the
forces caused by pouring of concrete and vibrations. This standard specifies the requirements of such plywood
for use in concrete shuttering and form work and provides guidance in the manufacture and use of the plywood.
This standard on plywood for concrete shuttering works was first published in 1969 and subsequently revised
in 1981, 1990 and 2011. In this revision, the following major modifications have been incorporated:
This standard also includes in Annex E, on the recommended method for handling, storing and use of
plywood for concrete shuttering and form work.
A scheme of labelling environment friendly products known as ECO-Mark has been instituted at the instance of
the Ministry of Environment, Forests and Climate Change, Government of India. The ECO-Mark is administered
by the Bureau of Indian Standards (BIS) under the Bureau of Indian Standards Act, 2016 as per the
Resolution No. 71 dated 21 February 1991 and Resolution No. 425 dated 20 October 1992 published in the
Gazette of the Government of India. For a product to be eligible for ECO-Mark, it shall also carry the Standard
Mark (ISI Mark) of BIS besides meeting additional environment friendly requirements. For this purpose, the
Standard Mark of BIS would be a single mark being a combination of the ISI Mark and the ECO-Mark.
Requirements to be satisfied for a product to qualify for the BIS Standard Mark for ECO-friendliness are
optional. Manufacturing units are free to opt for ISI Mark alone also.
The ECO criteria is based on the Gazette Notification No. 170 dated 16 May 1996 for wood substitutes as
environment friendly products published in the Gazette of Government of India, as revised/amended from time to
time.
This standard contributes to the United Nations Sustainable Development Goal 9 ‘Industry innovation and
infrastructure’ Build resilient infrastructure promote inclusive and sustainable industrialization and foster
innovation.
The composition of the Committee responsible for the formulation of the standard is given in Annex F.
For the purpose of deciding whether a particular requirement of this standard is complied with the final value,
observed or calculated, expressing the result of a test or analysis shall be rounded off in accordance with
IS 2 : 2022 ‘Rules for rounding off numerical values (second revision)’. The number of significant places retained
in the rounded off value should be the same as that of the specified value in this standard.
                                                                                                 IS 4990 : 2024
                                             Indian Standard
          PLYWOOD FOR CONCRETE SHUTTERING WORKS —
                        SPECIFICATION
                                             ( Fourth Revision )
1 SCOPE                                                     5 MATERIALS
  (1)                (2)                   (3)              6.1 Veneers for the manufacture of plywood for
                                                            concrete shuttering works shall be either rotary cut
  i)      Plywood for concrete             CS
                                                            or sliced, but preferably rotary cut. The veneers
          shuttering work (plain)
                                                            shall be reasonably smooth to permit an even spread
   ii)    Plywood for concrete            CSC               of glue. The veneers shall be dried to a moisture
          shuttering work with                              content in a range of 6 percent to 10 percent before
          polymer coating (coated)                          bonding. The glue shall be evenly spread. The
   iii)   Plywood for concrete            CSFF              veneers shall then be assembled with alternate layers
          shuttering work with                              at right angles to each other (except in the case of
          suitable overlay (film                            even number of veneers when the two central
          faced)                                            veneers are in the same direction) and hot pressed
                                                            under controlled conditions of temperature, pressure
4.2 In terms of formaldehyde class, each type of            and pressing time. The core veneers shall not have
plywood shall be further classified in two classes as       open joints or splits beyond the limits prescribed
follows:                                                    in 8.2. No unglued area shall be found on
                                                            separation of the veneers.
     a)   Formaldehyde Class, 𝐸1
                                                            The veneers may have sound knots of diameter
     b) Formaldehyde Class, 𝐸2                              not exceeding 50 mm. Tight fitted patches, with
                                                        1
IS 4990 : 2024
distance from one patch to the other not less than           7 DIMENSIONS AND TOLERANCES
600 mm, shall be permitted, but maximum diameter
of any patch shall not exceed 40 mm. The number              7.1 Any dimensions (length, width and thickness)
of pin-holes on face (top) veneers shall not be more         and number of ply as agreed to between the
than 10 in any square metre of the surface.                  manufacturer and the purchaser may be used and
Discolouration may be permitted, but loose knots             shall also be declared by the manufacturer.
and dry-rot shall not be permitted (see 8.1).                Prevailing dimensions (length × width) of plywood
                                                             boards are as given below:
6.2 The thickness of all individual veneers shall be
uniform with a variation of ± 5 percent. The veneer              a)    2 440 mm × 1 220 mm;
shall be straight grained within a permitted slope               b)    2 135 mm × 1 220 mm;
of ± 10°.
                                                                 c)    2 135 mm × 915 mm;
6.3 Corresponding veneers on either side of the                  d)    1 830 mm × 1 220 mm; and
central ply and those of face (top) and back (bottom)            e)    1 830 mm × 915 mm.
veneers shall be of species having similar physical
and mechanical properties, such as thickness,                7.2 Thickness
density, modulus of elasticity, shrinkage, etc to
ensure balanced construction.                                The thickness of the plywood boards shall be 3 mm,
                                                             4 mm, 5 mm, 6 mm, 9 mm, 12 mm, 15 mm, 19 mm,
6.4 Plywood for concrete shuttering work shall be            22 mm and 25 mm.
preservative treated and bonded with BWP
Grade adhesive. When required, concrete shuttering               NOTE — Any other thickness as agreed to between the
plywood may be supplied with or without any                      manufacturer and the purchaser may also be used.
polymer coating or suitable overlay (see 6.7
and 10.6).                                                   7.3 Squareness and Edge Straightness
6.5 When boards of a size larger than the available          Edge straightness and squareness shall be tested
press size are required, these may be made by scarf          as per Annex C.
jointing the finished board, the scarf being through
the thickness of the board.                                  7.4 Tolerances
All scarf joints shall be bonded with adhesives              The tolerances on the dimensions of finished
conforming to IS 848, having similar properties to           plywood boards shall be as given in Table 1.
those used in the bond of veneers. Scarf joints
shall be made with 1 : 8 slope.                               Table 1 Tolerances on Dimensions of Plywood
                                                                          for General Purposes
6.6 The plywood after manufacture shall be given                               (Clause 7.4)
a preservative treatment as given in IS 5539 and
conditioned to a moisture content not exceeding
                                                              Sl No.         Dimension             Tolerance
15 percent. The preservative used shall have a
copper-chrome-boron (CCB) composition or acid-
copper-chrome (ACC) composition, with retention                 (1)               (2)                 (3)
of not less than 12 kg/m3.                                       i)      Length                     + 6 mm
                                                                                                    – 0 mm
6.7 Plywood for concrete shuttering work with                   ii)      Width                      + 3 mm
polymer coating, or with suitable overlay shall be                                                  – 0 mm
made with a surface film of phenol formaldehyde or
creosol formaldehyde resin, either carried by tissue            iii)     Thickness
paper or evenly spread by a mechanical spreader                              a) less than         ± 10 percent
with resin content not less than 100 g/m2 (paper                                6 mm
weight: total weight shall be at least 1 : 1.5), which                       b) 6 mm and          ± 5 percent
is subsequently cured under heat and pressure to                                above
give a smooth and waterproof surface. The film                  iv)      Squareness, Max        2 mm/1 000 mm
shall be applied on the surface of preservative                                                  or 0.2 percent
treated plywood after manufacture. The pressing
shall be such that the film uniformly melts and                 v)       Edge straightness,     2 mm/1 000 mm
finishes into a smooth and hard surface on the                           Max                     or 0.2 percent
plywood.
                                                         2
                                                                                                           IS 4990 : 2024
8.1 The plywood for concrete shuttering work shall           10.4.1 Glue Shear Strength
be smooth and the face (top) and back (bottom)
shall be free from discolouration, pleats, overlaps          Six test specimens from each pair of glue lines shall
and loose knots. The edges shall have smooth                 be tested in accordance with the method described
uniform finish.                                              in IS 1734 (Part 4). The average failing load shall
                                                             be not less than the corresponding values specified
8.2 Gaps and open joints shall be permitted as               in Table 2.
follows:
                                                             10.4.2 Adhesion of Plies
    a)   In face (top) — The gap or opening shall
         not exceed a width of 0.4 mm. If it                 Adhesion shall be tested by knife test method
         exceeds 0.4 mm, this may be rectified by            described in IS 1734 (Part 5). The adhesion of plies
         well-fitted veneer inserts of suitable width        may also be tested by forcibly separating the layers.
         provided the grain of the veneer insert does        The veneers shall offer appreciable resistance to
         not deviate by more than 10 percent from            separation and the fractured samples shall show
         the grain direction of the surrounding              some adherent fibres distributed more or less
         veneer.                                             uniformly.
    b) In core (cross-band) — The width of the                    NOTE — If a definite result is not obtained by the method
                                                                  described in IS 1734 (Part 4), the result of knife test
       opening shall not exceed 1 mm in the case                  described in IS 1734 (Part 5) shall be considered as decisive.
       of 3 ply and 5 ply, and 2 mm in the case of                In case of even number of plies, where the grains of central
       plywood of more than 5 ply, provided such                  plies follow the same direction the result as obtained from
       openings are not less than 300 mm apart in                 knife test shall be considered as final.
       any veneer and staggered not less than
       150 mm between any veneer and the next                10.5 Resistance to Water Test
       one with the same grain direction.
                                                             Six test pieces each approximately 250 mm × 100 mm,
8.3 The faces (top/bottom) of plywood for concrete           shall be cut from any position in the board such that the
shuttering work with polymer coating, or with                grains of the face veneer are parallel to the length of the
suitable overlay, shall be dense, smooth and                 piece. Six test specimens from each pair of glue lines
without blisters and patch marks. It shall be of             shall be prepared as given in IS 1734 (Part 4). The
uniform colour.                                              specimens shall be subjected to any one of the tests
                                                             specified in 10.5.1 and 10.5.2.
9 SAMPLING
                                                             10.5.1 The specimens shall be kept submerged
The method of drawing representative samples,                horizontally in a pan of boiling water for a period of
sample size and the criteria for conformity shall be         72 h. The period of 72 h of boiling may be a
as prescribed in IS 7638.                                    continuous period or an aggregate of smaller periods
                                                             of boiling, if the test piece is left in cold water
10 TESTS                                                     between these smaller periods. The test pieces shall
                                                             then be removed from the boiling water and cooled
10.1 The plywood shall conform to the requirements           down to room temperature by plunging them in cold
given in 10.3 to 10.12.                                      water. These test specimens, while still in wet
                                                             condition, shall be subjected to tests described
10.2 Unless otherwise specified in this standard, six        under 10.5.1.1 and 10.5.1.2.
test specimens, cut from each of the plywood
selected as in 9 for tests specified in 10.3 to 10.10.       10.5.1.1 Glue shear strength
For formaldehyde content and steady-state
formaldehyde emission test, specimens shall be               When tested for glue shear strength by the method
taken as per IS 13745 and IS/ISO 12460 (Part 1)              described in IS 1734 (Part 4), the average failing
respectively.                                                load shall be not less than the corresponding values
                                                             specified in Table 2.
10.3 Moisture Content
                                                             10.5.1.2 Adhesion of plies
The average moisture content of three test pieces cut
out from each board selected as in 9, when tested in         Adhesion shall be tested by knife test method
accordance with IS 1734 (Part 1), shall be                   described in IS 1734 (Part 5). The adhesion of plies
not less than 5 percent and not more than 15 percent.        may also be tested by forcibly separating the layers;
                                                         3
IS 4990 : 2024
the veneers shall offer appreciable resistance to                       NOTE — In case a definite result is not obtainable by the
                                                                        method described in IS 1734 (Part 4), the result of knife test
separation and the fractured sample shall show                          described in IS 1734 (Part 5) shall be considered as decisive.
some adherent fibres distributed more or less                           In case of even number of plies, where the grains of central
uniformly.                                                              plies follow the same direction the result as obtained from
                                                                        knife test shall be considered as final.
    NOTE — In case a definite result is not obtainable by
    the method described in IS 1734 (Part 4), the result of         10.8 Tensile Strength
    knife test described in IS 1734 (Part 5) shall be
    considered as decisive. In case of even number of plies,
    where the grains of central plies follow the same               The tensile strength, when determined by the
    direction the result as obtained from knife test shall be       method described in IS 1734 (Part 9), shall comply
    considered as final.
                                                                    with the following requirements:
10.5.2 The specimens shall be subjected to constant                     a)   Tensile strength shall be not less than
steam pressure for a definite duration inside a                              28 N/mm2 in the direction parallel to the
vacuum steam pressure test apparatus as described                            grain direction of the face veneers;
in Annex D and thereafter subjected to tests as
per 10.5.1.1 and 10.5.1.2.                                              b) Tensile strength shall be not less than
                                                                           26 N/mm2 in the direction at right angles to
10.6 Plywood for concrete shuttering work with                             the grain direction of the face veneers; and
polymer coating or with suitable overlay (see 6.4),
                                                                        c)   The sum of the tensile strengths in
after being subjected to 72 h boiling, shall not show
                                                                             both directions shall be not less than
any softening, checking, cracking or deterioration of
                                                                             60.0 N/mm2.
the surface layer.
The test for resistance to micro-organisms shall be                 Three test specimens taken in each direction from
carried out by the method described in                              the sample of plywood, when tested in accordance
IS 1734 (Part 7). The test piece shall;                              with IS 1734 (Part 11) shall have an average and a
                                                                    minimum individual modulus of elasticity and
    a) show no appreciable signs of separation at                   modulus of rupture not less than the values
       the edges of the veneers; and                                specified in Table 3.
                                                                4
                                                                                                             IS 4990 : 2024
              Table 2 Minimum Average Failing Load and Percentage Wood Failure Requirements of
                                             Structural Plywood
                                               (Clauses 10.4.1, 10.5.1.1 and 10.7.1)
       Table 3 Average and Minimum Individual Values of Modulus of Elasticity (MOE) and Modulus
                              of Rupture (MOR) in Static Bending Strength
(Clause 10.9)
         Table 4 Minimum Average and Minimum Individual Values of Modulus of Elasticity (MOE)
                       and Modulus of Rupture (MOR) for Wet Bending Strength
                                                          (Clause 10.10)
                               a)    Average                                             21                 17
                               b) Minimum individual                                     19                 15
                                                                5
IS 4990 : 2024
    b) Formaldehyde Class, 𝐸2       > 0.124 mg/m3.              d) Nominal length, width and thickness of
                                                                   plywood;
10.14 Re-test                                                   e)   Month and year of manufacture;
                                                                f)   Batch No.; and
If any specimen fails to fulfil the test requirements
specified under 10.3 to 10.12, a further two sets of            g) Criteria for which the plywood has been
samples on the basis prescribed in 9 shall be                      labelled as ECO-Mark (if applicable).
selected by the purchaser from the same batch and
tested in the same manner. Test specimens                   12.2 Following additional information may be
prepared from these two further samples shall               marked on each plywood:
comply with the requirements specified in 10,
otherwise the batch shall be rejected.                          a)   Number of plies; and
                                                        6
                                                                                                 IS 4990 : 2024
12.3 BIS Certification Marking                             The manufacturer shall supply on demand to the
                                                           purchaser full technical data and recommended
The product(s) conforming to the requirements of           method of use and loading. This information shall
this standard may be certified as per the conformity       cover in particular the following:
assessment schemes under the provisions of the                 a)   Type of preservative used;
Bureau of Indian Standards Act, 2016 and the
Rules and Regulations framed there under, and the              b) Radii to which the plywood of given
products may be marked with the Standard Mark.                    dimensions is recommended as bendable
                                                                  for architectural concrete work;
13 DELIVERY                                                    c)   Loading and deflection tables for the
                                                                    purpose of calculating the supports, that is,
Unless otherwise specified, the plywood boards                      the sizes of bearers and distances of
shall be delivered in a clean condition and shall be                bearers;
suitably packed according to normal trade. For
                                                               d) Density or mass per square metre of the
ECO-Mark the material used for packaging of the
                                                                  plywood; and
plywood shall be recyclable, reusable or
biodegradable.                                                 e)   Species of timber.
                                                       7
IS 4990 : 2024
                                                  ANNEX A
                                                   (Clause 2)
 IS 707 : 2011          Timber technology and                   IS 2753 (Part 1) :     Methods for estimation of
                        utilization of wood, bamboo             1991                   preservatives in treated
                        and cane — Glossary of                                         timber and in treating
                        terms (third revision)                                         solutions:       Part     1
                                                                                       Determination of copper,
 IS 848 : 2006          Synthetic resin adhesives for                                  arsenic, chromium, zinc,
                        plywood      (phenolic   and                                   boron, creosote and fuel oil
                        aminoplastic) — Specification                                  (first revision)
                        (second revision)
                                                                IS 5539 : 1969         Specification for preservative
 IS 1150 : 2000         Trade names and abbreviated
                                                                                       treated plywood
                        symbols for timber species
                        (third revision)                        IS 7638 : 1999         Wood/lignocellulosic based
 IS 1734                Methods of test for plywood:                                   panel products — Methods of
                                                                                       sampling (second revision)
     (Part 1) : 1983    Determination of density and
                        moisture content (second                IS/ISO 12460-1 :       Wood based panels —‒
                        revision)                               2007                   Determination             of
                                                                                       formaldehyde release: Part 1
     (Part 4) : 1983    Determination of glue shear                                    Formaldehyde emission by
                        strength (second revision)                                     the 1-cubic-metre chamber
     (Part 5) : 1983    Test for adhesion of plies                                     method
                        (second revision)
                                                                IS 13745 : 2020        Method for determination of
     (Part 7) : 1983    Mycological    test   (second                                  formaldehyde content in
                        revision)                                                      wood-based     panels    by
                                                                                       extraction method called
     (Part 11) : 1983   Determination   of  static                                     perforator method (first
                        bending strength (second
                                                                                       revision)
                        revision)
                                                        8
                                                                                                    IS 4990 : 2024
                                                     ANNEX B
                                                     (Clause 5.1)
         LIST OF PREVALENT TREE OUTSIDE FOREST (TOF) SPECIES FOR PLYWOOD
                                                     ANNEX C
                                                     (Clause 7.3)
The straightness of the edges and ends of plywood              C-2 PROCEDURE FOR SQUARENESS
shall be verified against a straight edge not less than
the full length of the plywood. If the edge on the end         The squareness of plywood shall be checked with
of plywood is convex, it shall be held against the             a 1 200 mm × 1 200 mm square, by applying, one
straightedge in such a way as to give approximately            arm of the square to the plywood. The maximum
equal gap at each end. The largest gap between the             width of the gap shall be recorded.
straightedge and the edge shall be measured to the
                                                          9
IS 4990 : 2024
                                                 ANNEX D
                                               (Clause 10.5.2)
D-1 Pure water shall be filled in the boiler of the        chamber, the vacuum pump shall be switched off,
vacuum steam pressure test (VPT) apparatus as              the vacuum inlet valve closed and boiler valve
shown in Fig. 1 to the marking of minimum water            connected to main chamber opened. The time shall
level on glass water level indicator and the boiler        be noted the moment the steam pressure in the main
shall be switched on with the valve connecting the                                 +10
                                                           chamber reaches 220          kPa and same pressure
boiler and main chamber in closed condition. The                                    −0
test specimen(s) shall be placed in the working            shall be maintained for 6 h. The system and boiler
(main) chamber and shall be closed air tight with          then shall be switched off. The steam release valve
cover. The vacuum pump shall then be switched              and vacuum release value shall slowly be opened
on and vacuum inlet valve shall be kept in open            until the steam in the chamber is completely
condition. The steam release valve shall be kept in        evacuated. The samples shall then be kept in water
closed condition. After the required vacuum of             for 1 h at 27 °C ± 2 °C. The samples shall
     +10                                                   thereafter be tested as per 10.5.1.1 and 10.5.1.2.
110      kPa has been created inside the main
     −0
                                                      10
                                                                                                      IS 4990 : 2024
                                                      ANNEX E
                                                      (Foreword)
       RECOMMENDED METHOD OF HANDLING, STORING AND USE OF PLYWOOD FOR
                    CONCRETE SHUTTERlNG AND FORM WORK
E-2.1 At the time of dispatch from the factory, the             Cut edges of the plywood at the time of making
plywood panels shall be carefully loaded to prevent             concrete former should also be coated with suitable
any damage. Extra care should be taken in the case              sealants like chlorinated rubber paint, for longer life
of coated and film faced plywood to avoid any                   of the board.
scratches. Preferably a sheet of thick water proof
paper/polythene sheet may be inserted between the               E-4 DRYING OF PANELS
two surfaces to prevent scratches. The plywood
should be properly secured and covered with                     The plywood for concrete shuttering work may be
tarpaulin to ensure delivery to destination in clean            used repeatedly. However, if it has to be stored for
and serviceable condition.                                      a long time after one use, the panels should be dried
                                                                by stacking in free circulation of air and on suitable
E-2.2 The plywood panels shall be unloaded                      spacers before storage.
carefully from the carrier truck or wagon. These
shall be lifted, carried and stacked in a careful               E-5 DESIGN DATA
manner to avoid damage to the corners of surfaces.
These shall be stored in packs on a level, flat and             E-5.1 The following data are generally applicable to
raised surface in a clean, dry and covered place with           plywood for concrete shuttering work. However, as
free circulation of air. The boards and stacks shall            the species of timber used vary from manufacturer
be protected from rain and dampness. The edges of               to manufacturer and with that the density and
a board in a pack shall be in a straight vertical line.         strength, the instructions of the manufacturers would
The top of the stack shall be covered with a cover              be helpful for individual cases.
board and weighed down suitably.
                                                           11
IS 4990 : 2024
Generally, density of plywood for concrete                          The following are approximately the minimum
shuttering work may be taken as 650 kg/m3.                          bending radii for plywood for concrete shuttering
                                                                    work, when dry:
The mass per square metre in various thickness is
given below:                                                         Sl      Thickness     Across the     Parallel with
                                                                     No.                   Group of       the Group of
  Sl No.          Thickness                 Mass                                           the Outer        the Outer
                    mm                      kg/m2                                            Plies            Plies
       (1)           (2)                      (3)                               mm              m                m
       i)             6                      3.90                    (1)        (2)            (3)              (4)
       ii)            9                      5.85                     i)         6            0.90             1.25
       iii)          12                      7.80                     ii)        9            1.65             2.15
       iv)           19                     12.35                     iii)      12            2.55             3.30
       v)            25                     16.25
       NOTE — When in wet condition, the mass may increase          E-5.3.1 Plywood without any polymer coating or
       by 30 percent or more. The accuracy of the above mass        suitable overlay may be bent to still smaller radii by
       can be taken only within a tolerance of ± 10 percent
       because of varying species and also variation in the
                                                                    soaking in cold or hot water (temperature up to
       moisture content.                                            70 °C) before fixing.
E-5.2 Loading and Deflection                                        E-5.4 Fixing
Taking the maximum permitted deflection as 1 : 270                  It is advised that, wherever possible, screws or nuts
(that is 1/270th of the span between the bearers), the              and bolts are used for fixing. While handling,
following load per square meter, in kg/m2, are                      scratching by screws, nuts and bolts or other metal
arrived at; the maximum load permitted is given                     fixtures should be avoided. This is particularly so in
provided that the face grain of the plywood is                      case of plywood with polymer coating or with
perpendicular to the length of bearers:                             suitable overlay.
                                                               12
                                                                                                     IS 4990 : 2024
E-6.2 Concrete formers for concrete walls or other             E-6.7 Many users use thin sheets of plywood for
broad vertical surface works may be similarly made             concrete shuttering as linings over conventional
in the form of wood or iron frames fixed with                  timber shuttering. The advantage gained by this is,
shuttering plywood panels. The two wide side                   primarily, a uniform, smooth surface on the concrete
surfaces on the two sides of a wall can be further             work. Care should be taken in such cases that the
secured to avoid a sag at intermediate places by use           level of timber battens is reasonably correct to take
of nut and bolts through the concrete. This would              the maximum advantage of getting a uniform and
keep the former frames from spreading out. Such                smooth surface finish of concrete work.
intermediate nuts and bolts may be removed after
48 h of concrete pouring and the hole in the wall              E-6.8 When used for architectural concrete and
later on plugged with concrete. The bolts may also             curved forms, the data given in E-5.3 should be
be left in and later on cut out at the protruding              used to design the curved surfaces of the formers.
portions. An alternative method would be the
provision of well-designed additional supports and             E-6.9 When removing concrete formers or sheets,
props outside. Formers, if required on one side only           care should be taken to carry out the parting, sliding
of a wall as in underground tanks and sewers, should           and lowering carefully to avoid damage.
be similarly made and suitably supported.
                                                               E-6.10 Plywood supplied with suitable overlay
E-6.3 In case of concrete slabs, the concrete                  requires handling with special care to avoid
shuttering plywood may be laid without any                     scratching of the surface as scratches on the surface
framework on suitable bearers and be assembled                 take away the advantage of surface overlay. The
side by side with suitable fixing cleats to avoid any          sheets after each use shall be cleaned off of any
ridge formation in the concrete work at the joint.             sticking sand or aggregate.
Dismantling may be done by carefully removing the
props and beams from one side. Some users prefer               E-7 PRECAUTIONS
use of backing frame work even for horizontal slabs
and beams. Backing framework may be made of                    E-7.1 After work at one site is over, the plywood
wood or steel.                                                 used should be dried and sent to stores, or taken for
                                                               re-use elsewhere. If a builder has finished work
E-6.4 For concrete beams, box formers are made                 and does not want to store the plywood for long,
as in E-6.1 and then suitably supported by props.              the same could be disposed off to another builder
                                                               for shuttering work or may be used as plywood of
E-6.5 Some users use steel framework into which                non-decorative type for general purpose.
plywood may be slid just in the same way as pressed
steel shuttering sheets. The plywood for use as                E-7.2 There is a tendency in builders to cut plywood
shuttering in such cases should be cut to the size of          to shorter sizes for convenient handling. This should
the recess or to the required shape and rested into the        be discouraged as the greatest advantage of plywood
position like shuttering steel sheets.                         for concrete shuttering is in its availability in large
                                                               sizes leading to smooth ridge-free concrete work,
E-6.6 The supporting structure for the plywood                 thus saving in the expenses of elaborate plastering.
shuttering should be adequately strong. The design
data given under E-5.2 provides some guidance to
design these supports.
                                                          13
IS 4990 : 2024
                                                   ANNEX F
                                                   (Foreword)
                                       COMMITTEE COMPOSITION
                  Wood and Other Lignocellulosic Products Sectional Committee, CED 20
Organization Representative(s)
                                                      14
                                                                                                IS 4990 : 2024
Organization Representative(s)
                                           Member Secretary
                                    SHRI PRADEEP SINGH SHEKHAWAT
                                     SCIENTIST ‘D’/JOINT DIRECTOR
                                       (CIVIL ENGINEERING), BIS
Plywood, Veneers and Adhesives for Wood Products Subcommittee, CED 20:1
Organization Representative(s)
                                                    15
IS 4990 : 2024
Organization Representative(s)
  In Personal Capacity (House No. 12, HIG, 1st Stage,        SHRI S. S. ZOOLAGUD
      K.H.B. Colony, Basaveswara Nagar,
      Bangaluru)
                                                        16
Bureau of Indian Standards
BIS is a statutory institution established under the Bureau of Indian Standards Act, 2016 to promote harmonious
development of the activities of standardization, marking and quality certification of goods and attending to
connected matters in the country.
Copyright
BIS has the copyright of all its publications. No part of these publications may be reproduced in any form without
the prior permission in writing of BIS. This does not preclude the free use, in the course of implementing the
standard, of necessary details, such as symbols and sizes, type or grade designations. Enquiries relating to
copyright be addressed to the Head (Publication & Sales), BIS.
Amendments are issued to standards as the need arises on the basis of comments. Standards are also reviewed
periodically; a standard along with amendments is reaffirmed when such review indicates that no changes are
needed; if the review indicates that changes are needed, it is taken up for revision. Users of Indian Standards
should ascertain that they are in possession of the latest amendments or edition by referring to the website-
www.bis.gov.in or www.standardsbis.in
This Indian Standard has been developed from Doc No.: CED 20 (22830).