Construction Of Electrical Cars Factory Project
CEER
KAS For Engineering Consultants
Specefication
# Refrence Item Unit QTY ON DWG QTY IN BOQ REMARKS
number
Devision ( 16 ) Electrical Works:
Date:-25-07-2023
INSIDE FACTORY :
16-01 ELECTRICAL PANEL
Supply and installation of the following switchboards including all equipment, instruments,
16-01
devices, fittings and accessories, fixings, etc.; as shown in drawings and all as specified
1 16-01-01 REF. DPBAC 1-1 Unit 1 1
2 16-01-02 REF. DPBAC 1-2 Unit 1 1
3 16-01-03 REF. DPBAC 2-1 Unit 1 1
4 16-01-04 REF. DPBAC 2-2 Unit 1 1
5 16-01-05 REF. DPBAC 3-1 Unit 1 1
6 16-01-06 REF. DPBAC 3-2 Unit 1 1
7 16-01-07 REF. DPBAC 4-1 Unit 1 1
REF. DPBAC 4-2
8 16-01-08 Unit 1 1
9 16-01-09 REF. DPBEF 1-1 Unit 1 1
10 16-01-10 REF. DPBEF 1-2 Unit 1 1
11 16-01-11 REF. PBEF 2-1 Unit 1 1
12 16-01-12 REF. DPBEF 2-2 Unit 1 1
13 16-01-13 REF . DPBEF 3-1 Unit 1 1
14 16-01-14 REF. DPBEF 3-2 Unit 1 1
15 16-01-15 REF. DPBEF 4-1 Unit 1 1
16 16-01-16 REF. DPBEF 4-2 Unit 1 1
17 16-01-17 REF. DPPS-1A1 Unit 1 1
18 16-01-18 REF. DPPS-2A1 Unit 1 1
19 16-01-19 REF. DPPS-3A1 Unit 1 1
20 16-01-20 REF. DPPS-1A2 Unit 1 1
21 16-01-21 REF. DPPS-2A2 Unit 1 1
22 16-01-22 REF. DPPS-3A2 Unit 1 8
23 16-01-23 REF. DPPS-4A2 Unit 1 1
24 16-01-24 REF. DPPS-5A2 Unit 1 1
25 16-01-25 REF. DPPS-1A3 Unit 1 1
26 16-01-26 REF. DPPS-2A3 Unit 1 1
27 16-01-27 REF. DPPS-UPS1 Unit 1 1
28 16-01-28 REF. DPPS-UPS2 Unit 1 1
29 16-01-29 REF. DPPS-UPS3 Unit 1 1
30 16-01-30 REF. DPPS-UPS4 Unit 1 1
31 16-01-31 REF. DPPS-UPS5 Unit 1 1
32 16-01-29 REF. DPPS-1A4 Unit 1 1
33 16-01-30 REF. DPPS-2A4 Unit 1 1
34 16-01-31 REF. DPPS-3A4 Unit 1 1
35 16-01-32 REF. LPP-F1-01 Unit 1 1
36 16-01-33 REF. LPP-F1-02 Unit 1 1
37 16-01-34 REF. CIS PANEL Unit 1 1
38 16-01-35 REF. LPP-F2-01 Unit 1 1
Bill Of Quantities For DIV 16 1 Of 4
Construction Of Electrical Cars Factory Project
CEER
KAS For Engineering Consultants
Specefication
# Refrence Item Unit QTY ON DWG QTY IN BOQ REMARKS
number
39 16-01-36 REF. LPP-F2-02 Unit 1 1
40 16-01-37 REF. LPP-F3-01 Unit 1 1
41 16-01-38 REF. LPP-F3-02 Unit 1 1
42 16-01-39 REF. LPP-F4-01 Unit 1 1
43 16-01-40 REF. LPP-F4-02 Unit 1 1
16-02 LIGHTING UNITS
Supply and installation of the following light fittings, fixtures, including connections to
16 - 02 permanent wiring system; complete with all necessary fixings, fittings and accessories, hangers,
supports, drivers / transformer as per light fixture schedule etc., as shown in drawings
44 16 - 02- 01 Type F1 : Recessed square downlight LED 41W , 4000k , 25°, IP20 Unit 267.00 265
Type F1B : Recessed square downlight LED WITH BATTARY 41W , 4000k , 25°, IP20 emergency battery that
45 16 - 02- 02 Unit 144.00 143
works for 3 hours
46 16 - 02- 03 Type :F2 : Recessed MOUNTED LUMINAIRE LIGHT 21W, 4000K, IP44. Unit 89.00 87
Type :F2B : Recessed MOUNTED LUMINAIRE LIGHT WITH BATTARY 41W 21W, 4000K, IP44. emergency battery
47 16 - 02- 04 Unit 79.00 77
that works for 3 hours
48 16 - 02- 05 TYPE :F3: PACIFIC TYPE LED LUMINAIRE 44 W , 4000K, IP 44 Unit 147.00 145
TYPE :F3B: PACIFIC TYPE LED LUMINAIRE WITH BATTARY 44 W , 4000K, IP 44 emergency battery that works
49 16 - 02- 06 Unit 42.00 42
for 3 hours
50 16 - 02- 07 TYPE :H1 : HIGH BAY LUMINAIRE COMPLETE 1*149 W , 5000K, IP 44 Unit 285.00 283
TYPE :H1B : HIGH BAY LUMINAIRE COMPLETE WITH BATTARY 1*149 W , 5000K, IP 44 emergency battery that
51 16 - 02- 08 Unit 140.00 138
works for 3 hours
16-03 SOCKET & SWITCHS ELECTICAL
16 - 03 Supply and installation of fittings and accessories, as shown in drawings and all as specified
49 16-03-01 ONE WAY ONE GANG SWITCH 10A , 220V (S1) Unit 130.00 130
50 16-03-02 ONE WAY TWO GANG SWITCH 10A , 220V (S3) Unit 42.00 42
51 16-03-03 TWO WAY TWO GANG SWITCH 10A , 220V (S8) Unit 22.00 22
This item omited
52 16-03-04 ELECTRICAL VECHICLE DC CHARGING STATION (CCS) SOCKET 280A( 3PH+N+E) , IP66 Unit 13
from Consultant
53 16-03-05 SURFACE MOUNTING INDUSTRIAL SOCKET ,5PIN, 16A , 400V , 3PH, 60HZ,WEATHERPROOF TYPE IP44 Unit 45.00 45
54 16-03-06 SURFACE MOUNTING INDUSTRIAL SOCKET ,5PIN, 32A , 400V , 3PH, 60HZ,WEATHERPROOF TYPE IP44 Unit 65.00 65
55 16-03-07 SURFACE MOUNTING INDUSTRIAL SOCKET ,5PIN, 60A , 400V , 3PH, 60HZ,WEATHERPROOF TYPE IP44 Unit 2.00 2
56 16-03-07 SURFACE MOUNTING INDUSTRIAL SOCKET ,5PIN, 16A , 230V , 1PH, 60HZ,WEATHERPROOF TYPE IP44 Unit 4.00 4
57 16-03-08 SURFACE MOUNTING INDUSTRIAL SOCKET ,5PIN, 40A , 400V , 3PH, 60HZ,WEATHERPROOF TYPE IP44 Unit 2.00 2
SURFACE MOUNTING INDUSTRIAL SOCKET ,5PIN, 120A , 400V , 3PH, 60HZ,WEATHERPROOF TYPE IP44 for 3D
58 16-03-09 Unit 4.00 4
metal printer FEED FROM UPS 100KVA
SURFACE MOUNTING INDUSTRIAL SOCKET ,5PIN, 60A , 208V , 3PH, 60HZ,WEATHERPROOF TYPE IP44 for 3D
59 16-03-10 Unit 4.00 4
PLASTIC PRINTER FEED FROM UPS 50KVA INCLUDING ISOLATE TRANSFORMER
60 16-03-11 DISCONNECT SWITCH ( 30 amps, 600 volts , 3PHASE ) indoor, weatherproof, IP 55 Unit 74.00 1
61 16-03-12 DISCONNECT SWITCH ( 60 amps, 600 volts , 3PHASE ) indoor, weatherproof, IP 55 Unit 4.00 4
On the DWG we find
62 16-03-13 DISCONNECT SWITCH FOR COMPRESSOR ( 110 amps, 600 volts , 3PHASE ) indoor, weatherproof, IP 55 Unit 10.00 79
100amps
63 16-03-14 DISCONNECT SWITCH ( 125 amps, 600 volts , 3PHASE ) indoor, weatherproof, IP 55 Unit 6.00 6
64 16-03-15 floor box containing duplex electrical sockets on the floor, 16 amps, 220 volts,IP66 Unit 44
65 16-03-16 duplex electrical sockets (first floor) 16 amps, 220 volts with switch Unit 60
66 16-03-17 power socket for water heater 16A,220V AND DOUPLE POLE DISCONNECT SWITCH 20A Unit 38
67 16-03-18 power socket 25A,230V (1PH+N+E) Unit 74
16-04 IP TELEPHONE SYSTEM
SUPPLY, INSTALL, TESTING & COMMISSIONING DEVICES AND ACCESSORIES, COMPLETE WITH ALL NECESSARY
WIRING, CONDUIT, FIXING AND ACCESSORIESC
68 16-04-01 Patch Panel 24 slots full loaded Unit 18.00 18
69 16-04-02 Cable ORGANIZER Unit 18.00 18
70 16-04-03 Fiber Patch Panel LC/LC 24 port Unit 1.00 1
Bill Of Quantities For DIV 16 2 Of 4
Construction Of Electrical Cars Factory Project
CEER
KAS For Engineering Consultants
Specefication
# Refrence Item Unit QTY ON DWG QTY IN BOQ REMARKS
number
71 16-04-04 Network switch 24 port POE 10G with 4 port SFP Unit 18.00 18
72 16-04-05 Main Data Cabinet 42U Unit 1.00 1
73 16-04-06 Data Cabinet 12U Unit 8.00 8
74 16-04-07 PDU Unit 9.00 9
75 16-04-08 RJ45A Data Socket all rooms Unit 156.00 156
76 16-04-10 IP TELEPHONE UNIT 55.00 55
77 16-04-11 IPBX 2 LINE 100 INTERNAL TRANSFER Unit 1.00 1
16-05 CCTV CAMERA SYSTEM
Supplying ,installing internal and external surveillance cameras, all of which operate under the
OFF LINE system, with a CAT6A cable for each camera being pulled to the monitoring room
according to the plans and all that is needed to complete the work according to drawings ,the
16 - 05 terms ,specifications , according to including all excavation and backfilling works, the quantities
tables and the directives of the supervisory authority and samples must be submitted for
approval by the owner or consultant before supplying , According to the practices and all that is
necessary to complete the work according to the specifications .
78 16-05-01 IP THERMAL CAMERA Unit 5 5
79 16-05-02 IP INDOOR DOME CAMERA 4MP NIGHT VISION Unit 6 6
16-05-03 IP INDOOR FIXED CAMERA 4MP Unit 30 30
80 16-05-03 mointor (42 inch 4K) connected with CCTV control cabints Unit 12 12
81 16-05-04 CAT6A 305 M ROLL BELDEN CABLE Unit 30 30
82 16-05-05 128CH NVR WITH ONE MONTH RECORD UNIT 1 1
83 16-05-06 WORKSTATION UNIT 1 1
16-06 ACCESS CONTROL SYSTEM
Completion of card access control work and charged on the remaining price including the supply, installation
testing and operation of the card access control system complete with the security system control unit, card
16-06 reader, electric door lock, push button, including cables/wires, connection pipes and connection works
according to shown in the diagrams
Supply, installation, testing, commissioning and testing of a CARD READER to control door access and the item includes
84 16-06-01 Unit 42 42
wires, pipes and all that is needed to complete the work
Supply, installation, testing, commissioning and testing push button to control of doors and the item includes wires,
85 16-06-02 Unit 42 42
pipes and everything needed to complete the work
Supplying, installing, testing, operating and testing electrical strike locked door to the entry of doors and the item
86 16-06-03 Unit 42 42
includes wires, pipes and all that is needed to complete the work
Supply, installation, testing, commissioning and testing control door CONTROLLER (up door) and the item includes
87 16-06-04 Unit 42 42
wires, pipes and all that is needed to complete the work
88 16-06-05 CAT6A 305 M ROLL BELDEN CABLE Unit 15
16-07 PUBLIC ADDRESS SYSTEM
Supplying, installing, testing, operating and guaranteeing the Public Appeal System (PACC) according to the owner’s
requirements, provided that the system is one of the latest existing models and according to the owner’s requirements,
pipes, boxes and Shilded AUDIO cables size 2 * 2.5 mm and all the required accessories. In the case of using visible or
16 - 07 external pipes, pipes from Galvanized iron EMT, as well as boxes and all accessories, and doing everything necessary to
finish the work including all excavation and backfilling works,all that is necessary to complete the work according to
drawings , the specifications , in accordance with the bills of quantities, practices and directives with a consultant
engineer.
89 16-07-01 PUBLIC ADDRESS CABIENT 21U Unit 4.00 4
90 16-07-02 Supply, installation, testing, commissioning and testing of an amplifier unit (AMPLIFIER) with a capacity of 240 watts Unit 4.00 4
91 16-07-03 Supply, installation, testing, commissioning and testing of a ceiling speaker with adjustable output value 6 watts Unit 28.00 28
Supply, install, test, commission and test a dynamic microphone on table , the item includes the stand, cable, and size
92 16-07-04 Unit 2.00 2
according to where the microphone is to be used
93 16-07-05 AUDIO CABLE SHEILDED 305M ROLL CABLE Unit 5.00 5
16-08 Uninterruptible power supply (UPS)
Supply, install, wiring, grounding and testing & commisioning of "UPS"and all accessories needed to complete
16 - 08 the work.
UPS Capacity (100KVA), limited duration of 30 minutes, Input voltage 380V, 3PH, 60 HZ , Output 380V, 3PH, 60HZ, FOR
94 16 - 08- 01 UNIT 2.00 2
METAL PRINTER
UPS Capacity (50KVA), limited duration of 30 minutes, Input voltage 380V, 3PH, 60 HZ , Output 208V, 3PH, 60HZ - FOR
95 16 - 08- 02 PLASTIC PRINTER Unit 3.00 3
16-08 FIRE ALARM SYSTEMS NETWORK
Supply install, connect and test of fire alarm control and Voice evacuation system complete including conduits (PVC or
EMT) 20mm at least, conduit fittings, including interface with sound system, fire pump and stand-by generator and all
necessary accessories and ancillary works including all excavation and backfilling works as shown on drawings and as
specified in the technical specification in order to provide a complete system up to the main fire alarm control panel
(FACP) and doing everything necessary to finish the work, all that is necessary to complete the work according to
drawings , the specifications , in accordance with the bills of quantities, practices and directives with a consultant
engineer.
96 16 - 08 Addressable smoke detector UNIT 200.00 200
97 16 - 08- 01 Addressable heat detector UNIT 468.00 470
98 16 - 08- 02 Addressable intelligent Multi detector fixed temperature UNIT 75
99 16 - 08- 03 Addressable Fire alarm sounder UNIT 86
100 16 - 08- 04 Addressable fire alarm manual station UNIT 86
101 16 - 08- 05 Addressable intelligent monitor module for zone control valve UNIT 16
102 16 - 08- 06 Addressable intelligent module with control panel to shut down package unit in case of fire UNIT 50
103 16 - 08- 07 Addressable intelligent repeater panel UNIT 8
104 16 - 08- 08 Emergency lighting with 1.5 to 3 hour battery UNIT 155 155
105 16 - 08- 09 EXIT SIGN UNIT 35 35
106 16 - 08- 10 Addressable fire alarm control panel (FACP) UNIT 4 4
Bill Of Quantities For DIV 16 3 Of 4
Construction Of Electrical Cars Factory Project
CEER
KAS For Engineering Consultants
Specefication
# Refrence Item Unit QTY ON DWG QTY IN BOQ REMARKS
number
107 16 - 08- 11 FIRE alarm CABLE 2*1.5MM (1000M ROLL) ROLL 6 6
Sum of Devision ( 16 ) Electrical Works
Bill Of Quantities For DIV 16 4 Of 4