Total
Item Supply Install
Description Unit Qty. Unit Total Price
No. Price Price
Price
Section 16110
01 Raceways, Boxes and Fittings
01.01 LIGHTING OUTLET
Supply, install, connect and test of wall or ceiling lighting outlet
including conduit, conduit fittings, cable trunking, thermo plastic
cables (from panel board to the first outlet in the circuit then using
single core PVC copper conductors inside conduits till last lighting
fixture in the circuit) , earthing and boxes
01.01.01 Lighting outlet for lighting fixture type F01 No. 263.00 0.00 0.00
01.01.02 Lighting outlet for lighting fixture type F01/B No. 116.00 0.00 0.00
01.01.03 Lighting outlet for lighting fixture type FL2 No. 415.00 0.00 0.00
01.01.04 Lighting outlet for lighting fixture type FL2/B No. 196.00 0.00 0.00
01.01.05 Lighting outlet for lighting fixture type FL3 No. 96.00 0.00 0.00
01.01.06 Lighting outlet for lighting fixture type FL3/B No. 42.00 0.00 0.00
01.01.07 Lighting outlet for lighting fixture type W01/B No. 23.00 0.00 0.00
01.01.08 Lighting outlet for lighting fixture type D03/E No. 19.00 0.00 0.00
01.01.09 Lighting outlet for lighting fixture type EXIT1/E No. 6.00 0.00 0.00
01.01.10 Lighting outlet for lighting fixture type EXIT2/E No. 15.00 0.00 0.00
01.02 LIGHTING SWITCHES OUTLETS
Supply, install, connect and test of outlets for lighting switches,
including conduits, conduit fittings, boxes, wiring / cables and
earthing.
01.02.01 Outlet for lighting switch one way one gang 10A. No. 158.00 0.00 0.00
01.02.02 Outlet for lighting switch one way two gang 10A. No. 15.00 0.00 0.00
01.02.03 Lighting Outlet For Occupancy Sensor No. 93.00 0.00 0.00
01.02.04 Lighting Outlet For Motion Sensor No. 22.00 0.00 0.00
01.03 SOCKETS OUTLETS
Supply, install, connect and test of sockets outlets including
conduit, conduit fittings, cable trunking, thermo plastic cables
(from panel board to the first socket in the circuit then using single
core PVC copper conductors inside conduits till last sockets in the
circuit) , earthing and boxes.
01.03.01 Outlet for single phase single socket 16 A -220 V. No. 98.00 0.00 0.00
01.03.02 Outlet for single phase single socket 16 A -220 V Weather proof. No. 26.00 0.00 0.00
01.03.03 Outlet for single phase duplex socket 16 A -220 V No. 43.00 0.00 0.00
01.03.04 Outlet for single phase duplex socket 16 A -220 V UPS No. 27.00 0.00 0.00
No.
01.03.05 Outlet for three phase industrial socket 32 A -380 V 6.00 0.00 0.00
01.03.06 Outlet for Water Heater 20 A -220 V No. 8.00 0.00 0.00
01.03.07 Outlet for Hand Dryer 20 A -220 V No. 4.00 0.00 0.00
01.03.08 Electric outlet 16 A, 220 V No. 192.00 0.00 0.00
01.04 Switch Disconnectors (Isolators) Outlets
Supply, install, connect and test of isolators outlets including
conduits, conduit fittings, cable trunking, PVC/PVC cables / wiring
and earthing.
01.04.01 Electrical outlet for disconnect switch 16 A, 220 V No. 70.00 0.00 0.00
01.04.03 Electrical outlet for disconnect switch 32A, 220 V No. 1.00 0.00 0.00
01.05 Floor Boxes
Supply, install, connect and test of floor boxes fixed in floor and
suitable for fixing the wiring devices of different systems.
01.05.01 Floor Box type FB1 No. 9.00 0.00 0.00
01.06 Cable Tray
01.06.01 800x100 mm Mt. 848.40 0.00 0.00
01.06.02 600x100 mm Mt. 588.00 0.00 0.00
01.06.03 450x100 mm Mt. 742.00 0.00 0.00
01.06.04 400x100 mm Mt. 539.00 0.00 0.00
Page 1 of 5
Total
Item Supply Install
Description Unit Qty. Unit Total Price
No. Price Price
Price
01.06.05 300x100 mm Mt. 42.00 0.00 0.00
01.06.06 250x100 mm Mt. 614.60 0.00 0.00
01.06.07 200x100 mm Mt. 345.80 0.00 0.00
01.06.08 100x100 mm Mt. 380.80 0.00 0.00
01.07 Cable Trunk
01.07.01 600x100 mm Mt. 693.00 0.00 0.00
02 LOW VOLTAGE CABLES
Supply power cable 0.6/1kv, copper type and XLPE/PVC insulation
02.01 Multicore XLPE/PVC insulated copper cables
02.01.01 3X300+150 mm2 Mt. 294.00 0.00 0.00
02.01.02 3X240+120 mm2 Mt. 4,009.60 0.00 0.00
02.01.03 3X120+70 mm2 Mt. 513.80 0.00 0.00
02.01.04 4X35 mm2 Mt. 323.40 0.00 0.00
02.01.05 4X25 mm2 Mt. 77.00 0.00 0.00
02.01.06 4X16 mm2 Mt. 499.80 0.00 0.00
02.01.07 4X10 mm2 Mt. 5,250.00 0.00 0.00
02.01.08 4X6 mm2 Mt. 8,626.80 0.00 0.00
02.02 Multicore MICA/XLPE/LS0H insulated copper cables
02.02.01 3X240+120 mm2 Mt. 128.80 0.00 0.00
02.03 Single core PVC insulated copper cables for earthing E
02.03.01 1 x 150 mm2 Mt. 294.00 0.00 0.00
02.03.02 1 x 120 mm 2 Mt. 4,138.40 0.00 0.00
02.03.03 1 x 70 mm2 Mt. 513.80 0.00 0.00
02.03.04 1 x 16 mm 2 Mt. 900.20 0.00 0.00
02.03.05 1 x 10 mm2 Mt. 5,250.00 0.00 0.00
02.03.06 1 x6 mm 2 Mt. 8,626.80 0.00 0.00
Supply power cable 450/750 volt, copper type and PVC insulation
PVC Single Core Cable with Flexible Copper Conductor For DC
02.04 System
02.04.01 1x240 mm2 Mt. 15,758.40 0.00 0.00
02.04.02 1x50 mm2 Mt. 29,400.00 0.00 0.00
Section 16140
03 Wiring Devices
03.01 LIGHTING SWITCHES
Supply, install, connect and test of lighting switches, including face
plate and covers.
03.01.01 Lighting switch one way one gang 10A. No. 158.00 0.00 0.00
03.01.02 Lighting switch one way two gang 10A. No. 15.00 0.00 0.00
03.01.03 Occupancy Sensor No. 93.00 0.00 0.00
03.01.04 Motion Sensor No. 22.00 0.00 0.00
03.02 SOCKETS
Supply, install, connect and test of sockets, including face plate
and covers.
03.02.01 Single phase single socket 16 A -220 V. No. 98.00 0.00 0.00
03.02.02 Single phase single socket 16 A -220 V Weather proof. No. 26.00 0.00 0.00
03.02.03 Single phase duplex socket 16 A -220 V No. 43.00 0.00 0.00
Page 2 of 5
Total
Item Supply Install
Description Unit Qty. Unit Total Price
No. Price Price
Price
03.02.04 Single phase duplex socket 16 A -220 V UPS No. 27.00 0.00 0.00
03.02.05 Three phase industrial socket 32 A -380 V No. 6.00 0.00 0.00
Section 16170
04 Switch Disconnectors (Isolators)
Supply, install, connect and test of disconnect switches (isolators).
04.01 Disconnect switch 16 A, 220 V No. 70.00 0.00 0.00
04.02 Disconnect switch 32 A, 220V No. 1.00 0.00 0.00
04.02 Disconnect switch 1000A, 380V No. 4.00 0.00 0.00
04.02 Disconnect switch 100A, 380V No. 4.00 0.00 0.00
05 Earthing System
Supply, install, connect and test of earthing system the price
including sepatare earthing, ,excavation and backfilling, welding,
test links, earthing pits, including earthing of building foundation
reinforcing bars.
05.01 Earthing system for medium voltage equipment (2 ohm) LS 1.00 0.00 0.00
05.02 Earthing system for power systems (1 ohm) LS 1.00 0.00 0.00
05.03 Earthing system for telecommunication systems (0.5 ohm) LS 1.00 0.00 0.00
06 LIGHTNING PROTECTION SYSTEM
Supply, install, connect and test lightning protection system including,
06.01 early streamer and connection to earthing grid LS 1.00 0.00 0.00
Section 16264
07 Uninterruptible Power Supply (UPS)
Supply, Install, connect and test UPS system ,3PH - 50HZ with
maintenance free dry type battery , input 3-phase and output 3-
phase (380/220V-50HZ).
UPS unit 128 KW load- 380 V PF=0.8 equipped with batteries for
07.01 backup time 10 minutes and DC cables from UPS to batteries No. 6.00 0.00 0.00
07.02 Battery Monitoring System L.S
UPS unit 200 KW load- 380 V PF=0.8 equipped with batteries for
07.03 backup time 10 minutes and DC cables from UPS to batteries No. 4.00 0.00 0.00
07.04 Battery Monitoring System L.S
UPS unit 160KW load - 380 V PF=1 equipped with batteries for
07.05 No. 4.00 0.00 0.00
backup time 10 minutes and DC cables from UPS to batteries
07.06 Battery Monitoring System L.S
UPS unit 100KW load - 380 V PF=1 equipped with batteries for
07.07 No. 4.00 0.00 0.00
backup time 10 minutes and DC cables from UPS to batteries
07.08 Battery Monitoring System L.S
UPS unit 15KW load - 380 V PF=1 equipped with batteries for
07.09 No. 1.00 0.00 0.00
backup time 10 minutes and DC cables from UPS to batteries
07.10 Battery Monitoring System L.S
09 DC system for 310 kw load
Supply, Install, connect and test DC system 310KW load. including
09.01 rectifiers, power distribution frames , batteries sufficient to work No. 12.00 0.00 0.00
for 120 minutes.
09.02 PDF (3000A) No. 36.00 0.00 0.00
Section 16350
10 Power Distribution Tansformer
Supply, Install, connect & test distribution trasformers (CU/CU) of
dry type including enclosure.
Step down transformer 2500 KVA ,11/0.4 KV, 3 phase ,50Hz,low
10.01 No. 2.00 0.00 0.00
loss Dry type .
Step down transformer 2000 KVA ,11/0.4 KV, 3 phase ,50Hz,low
10.03 loss Dry type . No. 4.00 0.00 0.00
Page 3 of 5
Total
Item Supply Install
Description Unit Qty. Unit Total Price
No. Price Price
Price
11 LOW VOLTAGE SWITCHGEAR
11.01 MECH-ATS-A No. 1.00 0.00 0.00
11.02 MECH-ATS-B No. 1.00 0.00 0.00
11.03 IT12-ATS-A No. 1.00 0.00 0.00
11.04 IT12-ATS-B No. 1.00 0.00 0.00
11.05 IT32-ATS-A No. 1.00 0.00 0.00
11.06 IT32-ATS-B No. 1.00 0.00 0.00
11.07 MECH-ROOF-MDB-A No. 1.00 0.00 0.00
11.08 MECH-ROOF-MDB-B No. 1.00 0.00 0.00
11.09 IT-1st-MDB-A No. 1.00 0.00 0.00
11.10 IT-1st-MDB-B No. 1.00 0.00 0.00
11.11 IT-2nd-MDB-A1 No. 1.00 0.00 0.00
11.12 IT-2nd-MDB-B1 No. 1.00 0.00 0.00
11.13 IT-2nd-MDB-A2 No. 1.00 0.00 0.00
11.14 IT-2nd-MDB-B2 No. 1.00 0.00 0.00
11.15 IT-3rd-MDB-A No. 1.00 0.00 0.00
11.16 IT-3rd-MDB-B No. 1.00 0.00 0.00
11.17 POWER FACTOR CORRECTION PFC-1 No. 1.00 0.00 0.00
11.18 POWER FACTOR CORRECTION PFC-2 No. 1.00 0.00 0.00
11.19 POWER FACTOR CORRECTION PFC-3 No. 1.00 0.00 0.00
11.20 POWER FACTOR CORRECTION PFC-4 No. 1.00 0.00 0.00
11.21 POWER FACTOR CORRECTION PFC-5 No. 1.00 0.00 0.00
11.22 POWER FACTOR CORRECTION PFC-6 No. 1.00 0.00 0.00
11.23 FIRE PUMP CUBICAL CB-F.P No. 1.00 0.00 0.00
12 FEEDER BUSBAR TRUNKING
Supplying, install, connect and testing of low voltage Copper
busbar, feeder busbar trunking type, hanging (Horizontal/vertical),
mounting components and elbows for the following sizes:-
12.01 5000A. Mt. 368.20 0.00 0.00
12.02 4000A. Mt. 345.80 0.00 0.00
12.03 2500A. Mt. 362.60 0.00 0.00
12.04 1250A. Mt. 305.20 0.00 0.00
12.05 END FEED UNITS FOR TRANSFORMER 5000A No. 2.00 0.00 0.00
12.06 END FEED UNITS FOR TRANSFORMER 4000A No. 4.00 0.00 0.00
12.07 END FEED UNITS FOR GENERATOR 5000A No. 2.00 0.00 0.00
12.08 END FEED UNITS FOR GENERATOR 4000A No. 4.00 0.00 0.00
12.09 END FEED UNITS FOR LOW VOLTAGE PANEL 5000A No. 2.00 0.00 0.00
12.10 END FEED UNITS FOR LOW VOLTAGE PANEL 4000A No. 4.00 0.00 0.00
13 PANEL BOARDS
Supply, Install, connect and test low voltage panel boards.
13.01 PUMPS UDB-A No. 1.00 0.00 0.00
13.02 PUMPS UDB-B No. 1.00 0.00 0.00
13.03 UDB-1st-A No. 1.00 0.00 0.00
13.04 MECH UDB-1st-A No. 1.00 0.00 0.00
13.05 SERVICE UDB No. 1.00 0.00 0.00
13.06 UDB-1st-B No. 1.00 0.00 0.00
13.07 MECH UDB-1st-B No. 1.00 0.00 0.00
13.08 UDB-2nd-A1 No. 1.00 0.00 0.00
13.09 MECH UDB-2nd-A1 No. 1.00 0.00 0.00
13.10 UDB-2nd-B1 No. 1.00 0.00 0.00
13.11 MECH UDB-2nd-B1 No. 1.00 0.00 0.00
13.12 UDB-2nd-A2 No. 1.00 0.00 0.00
13.13 MECH UDB-2nd-A2 No. 1.00 0.00 0.00
13.14 UDB-2nd-B2 No. 1.00 0.00 0.00
13.15 MECH UDB-2nd-B2 No. 1.00 0.00 0.00
13.16 UDB-3rd-A No. 1.00 0.00 0.00
13.17 MECH UDB-3rd-A No. 1.00 0.00 0.00
13.18 UDB-3rd-B No. 1.00 0.00 0.00
13.19 MECH UDB-3rd-B No. 1.00 0.00 0.00
Page 4 of 5
Total
Item Supply Install
Description Unit Qty. Unit Total Price
No. Price Price
Price
13.20 G-L&P No. 1.00 0.00 0.00
13.21 F-L&P No. 1.00 0.00 0.00
13.22 S-L&P No. 1.00 0.00 0.00
13.23 TH-L&P No. 1.00 0.00 0.00
13.24 G-UPP No. 1.00 0.00 0.00
13.25 F-UPP No. 1.00 0.00 0.00
13.26 S-UPP No. 1.00 0.00 0.00
13.27 TH-UPP No. 1.00 0.00 0.00
Section 16500
14 LIGHTING FIXTURE
Supply, Install, connect and test of lighting fixtures including LED
lamps, electronic drivers.
14.01 lighting fixture type F01 No. 263.00 0.00 0.00
14.02 lighting fixture type F01/B No. 116.00 0.00 0.00
14.03 lighting fixture type FL2 No. 415.00 0.00 0.00
14.04 lighting fixture type FL2/B No. 196.00 0.00 0.00
14.05 lighting fixture type FL3 No. 96.00 0.00 0.00
14.06 lighting fixture type FL3/B No. 42.00 0.00 0.00
14.07 lighting fixture type W01/B No. 23.00 0.00 0.00
14.08 lighting fixture type D03/E No. 19.00 0.00 0.00
14.09 Llighting fixture type EXIT1/E No. 6.00 0.00 0.00
14.10 lighting fixture type EXIT2/E No. 15.00 0.00 0.00
15 DIESEL GENERATOR SET
Supplying, installing, connecting and testing of a 2250KVA
(1800KW) (at 50°C ambient) 0.8 p.f., 380V continous data center
diesel Generator(for linear/nonlinear loads) set including :
Control panel, Enclosure, residential silencer, flexible joints,
15.01 exhaust pipes, acoustic treatment, fuel system, daily fuel tanks 3 No. 2.00 0.00 0.00
m3, lines, foundation, accessories, canvas ducts, air inlet/outlet
sound attenuators louvers, monitoring and protection, Seismic
Support and battery charger.
Supplying, installing, connecting and testing of a 2000KVA
(1600KW) (at 50°C ambient) 0.8 p.f., 380V continous data center
diesel Generator(for linear/nonlinear loads) set including :
Control panel, Enclosure, residential silencer, flexible joints,
15.02 No. 4.00 0.00 0.00
exhaust pipes, acoustic treatment, fuel system, daily fuel tanks 3
m3, lines, foundation, accessories, canvas ducts, air inlet/outlet
sound attenuators louvers, monitoring and protection, Seismic
Support and battery charger.
TOTAL CARRIED TO TENDER SUMMARY 0.00