Lug Analysis

mechanicalc.com/reference/lug-analysis

Lug Analysis Overview


Analysis of a lug is deceptively complex since there are several simultaneous, interacting
failure modes. These failure modes are associated with different areas of the lug, as
illustrated in the figure below (Note: Figure not to scale):

The failure modes for the lug are listed


below. The numbers correspond with the
labeled sections from the above figure:

1. Tension failure across the net


section
2. Shear failure along two planes
3. Bearing failure
4. Hoop tension failure / fracture on
single plane
5. Out of plane buckling ("dishing") --
(not shown in the figure)

There are several common methods of analyzing a lug:

Simplified analysis - This method is based on first principles and involves making
simplifying assumptions about the nature of the failure and calculating factors of
safety. This has the advantage of being relatively easy, but it only gives an
approximate determination of the adequacy of the lug.
Air Force Method - This method considers most of the failure modes above, and it
uses empirical curves to determine more accurate allowable loads. This method
allows for lugs under axial loading, transverse loading, or oblique loading. This
method also accounts for the interaction between the lug and the clevis pin.
ASME BTH - This method considers most of the failure modes above, and it uses
simplified equations with correction factors based on empirical data to determine
more accurate allowable loads. This method is simpler than the Air Force Method,
but it only allows for lugs under axial loading and does not account for the
interaction between the lug and the clevis pin.

All of these methods are described in the following sections.

Simplified Analysis

1/30
This method is based on first principles (as well as on the simplified method outlined in
Bruhn) and involves making simplifying assumptions about the nature of the failure. While
it is relatively easy to perform, it only gives an approximate determination of the adequacy
of the lug and should not be employed for critical structure.

In the simplified analysis, the following failure modes are considered:

Tension failure across the net section


Shear failure along two planes
Bearing failure

A factor of safety is calculated for each of the failure modes, and as long as each factor of
safety is acceptable then the lug can be considered to pass. The figure below shows the
lug in blue and the pin in green.

The dimensions in the figure are:

Dh = hole diameter
Dp = pin diameter
R = edge distance (distance from center of hole to edge of lug in direction of applied
load)
r = radius of curvature of edge of lug (greater than or equal to R)
a = distance from edge of hole to edge of lug = R − 0.5 Dh
w = width
t = thickness (not shown in figure -- thickness is into the page)
Z = loss in shear plane length due to curvature at end of lug
ϕ = shear plane locating angle = 40°

Tension Failure Across Net Section

2/30
Tension failure across the net section occurs over the cross-section highlighted in red in
the figure below:

The area of the net section is given


by:

At = (w − Dh) t

The ultimate tensile load is the load


that would result in tensile failure
across the net section, and is given
by:

Ptu = Stu At

where Stu is the ultimate tensile strength of the lug material. The equation above assumes
a uniform tensile stress over the cross-section. In reality there will be a stress
concentration due to the flow of stress around the hole.

The factor of safety is given by:

Shear Tear Out Along Two Planes


Shear tear out occurs over the two shear planes highlighted in red in the figure below:

The total shear plane area is given by:

As = 2 Lsp t

where Lsp is the length of the shear


plane and t is the lug thickness. A
simple and conservative approach is
to calculate the length of a single
shear plane as:

Lsp = a

where a = R − 0.5 Dh, as shown in the


figure above. If it is desired to account
for a slightly longer shear plane, it is common practice to consider a 40 degree line
extending from the center of the shear pin. At the point where that 40 degree line
intersects the pin hole, extend the shear plane horizontally to the outer edge of the lug. In
this case, Lsp is calculated as:

3/30
where ϕ is the shear plane locating angle of 40°
and Z is the loss in shear plane length due to the
curvature at the end of the lug. This loss is
calculated as:

Note that if the lug end is flat then r is infinity and Z


is zero.

The ultimate shear load is the load that would result


in shear tear out along the two planes, and is given
by:

Psu = Ssu As

where Ssu is the ultimate shear strength of the lug material.

The factor of safety is given by:

Bearing Failure
Bearing occurs between the surface of the pin and the inner surface of the hole in the lug,
as shown in the figure below:

The bearing area is given by:

Abr = Dp t

Note that since the length of the


bearing surface is equal to the
diameter of the pin, and since the
circumference of a circle is given by C
= πD, then:

the length of the bearing surface


is also equal to 1/π times the circumference of the pin
the swept angle of the bearing surface is equal to 2 radians ≈ 115°

The ultimate bearing load is the load that would result in bearing failure, and is given by:

Pbru = Sbru Abr

where Sbru is the minimum of the ultimate bearing strength of the lug material and the
ultimate bearing strength of the pin material. The ultimate bearing strength can be
approximated as 1.5·Stu.

The factor of safety is given by:

4/30
If a bushing is pressed into the lug, then bearing needs to be
calculated for both sets of contact:

Pin on bushing
Bushing on lug

Mailing List

Subscribe to receive occasional updates on the latest improvements:

Air Force Method

The Air Force Method of lug analysis is widely used in industry and is documented in the
Stress Analysis Manual of the Air Force Flight Dynamics Laboratory (FDL). This method
follows closely with the methods presented in Melcon & Hoblit and Bruhn, and it relies
heavily on curves generated by empirical data. Although this method is somewhat more
complex than other lug analysis methods, it is incredibly useful because it allows for lugs
under axial loading, transverse loading, or oblique loading, and because it accounts for
the interaction between the lug and the pin.

This section discusses axial loading, transverse loading, and oblique loading separately.
These sections disregard the effect of the pin on the lug strength. A discussion of the pin
and lug interaction is given at the end.

Axial Loading
For axially loaded lugs, the Air Force method evaluates the lug for bearing failure, shear-
out failure, hoop tension failure, and failure across the net section. Three of the failure
modes are actually combined into a single failure mode -- the "bearing strength" accounts
for bearing, shear-out, and hoop tension. This is consistent with Bruhn and Melcon &
Hoblit.

The dimensions of interest for an axially loaded lug are shown in the figure below:

5/30
The dimensions from the figure include:

D = hole diameter
Dp = pin diameter
e = edge distance
a = distance from edge of hole to edge of lug = e − 0.5 D
w = width
t = thickness

Bearing Strength Under Axial Load

The ultimate bearing load, accounting for bearing, shear-out, and hoop tension, is given
by:

where D is the hole diameter, t is the


lug thickness, and Stu and Sty are
the lug material's ultimate and yield
tensile strengths, respectively. Fbru.L
and Fbry.L are the lug ultimate and yield bearing stresses, respectively, and are given by
the following equations:

e/D < 1.5 e/D ≥ 1.5

Ultimate Bearing Stress, Fbru.L: K Stu

Yield Bearing Stress, Fbry.L: K Sty

The equation for ultimate bearing load can be condensed down to:

6/30
For ratios of e/D less than 1.5, the hole is close to the edge of the lug and so shear-out
and hoop tension are likely to be the most critical failure modes. For larger values of e/D,
the hole is spaced farther from the edge and so bearing is likely to be the critical failure
mode.

The factor K in the equations above is the allowable axial load coefficient which accounts
for the interaction effects between the different failure modes (bearing, shear-out, and
hoop tension). The value of K is read off of one of the following two plots. The first plot is
used for D/t ≤ 5, which is the most common case. If D/t > 5 then the lug is thin, and in that
case the value of K is read off of the second plot below. (Note 2)

7/30
Bushing Bearing Strength Under Axial Load

If there is a bushing in the lug, then the bearing strength for the bushing must be
calculated. The bushing ultimate load is given by:

Pu.B = 1.304 Scy.B Dp t

where Dp is the pin diameter, t is the bushing thickness (assumed to be equal to the lug
thickness), and Scy.B is the compressive yield strength of the bushing material. The Air
Force manual assumes the compressive ultimate strength of the bushing material, Scu.B,
to be equal to 1.304·Scy.B.

If there is no bushing in the lug, then the calculation should still be performed assuming
that the lug material is the bushing material.

Net Section Strength Under Axial Load

The net-section ultimate load accounts for tension failure across the net section and is
calculated by:

8/30
where w is the width and D is the hole diameter. Fnu.L and Fny.L are the ultimate and yield
net-section stresses, respectively, and are given by the following equations:

Ultimate Net-Section Stress: Fnu.L = Kn Stu

Yield Net-Section Stress: Fny.L = Kn Sty

The equation for net section ultimate load can be condensed down to:
Pnu.L = Kn · min(Stu , 1.304 Sty) · (w − D) · t

The factor Kn in the equations above is the net tension stress coefficient which is a knock-
down on the allowable stresses. The value of Kn is determined by interpolating between
the following plots:

9/30
In the curves above, Fty and Ftu are the material's yield and ultimate strengths,
respectively, E is the elastic modulus, and εu is the ultimate strain (i.e. the total strain at
failure).

Design Strength Under Axial Load

10/30
The design ultimate load for an axially loaded lug is the minimum of the ultimate bearing
load, the ultimate bushing load, and the ultimate net-section load:

Pu.L.B = min( Pbru.L , Pu.B , Pnu.L )

Transverse Loading
The analysis for a transversely loaded lug is similar to that for an axially loaded lug.
However, the failure mode for transverse loading is more complicated than for axial
loading, and different dimensions are critical for determining lug strength. The dimensions
of interest for a transversely loaded lug are shown in the figure below:

where h1, h2, h3, and h4 are failure planes of interest. If the lug is symmetric, then the
values for these dimensions can be easily obtained from the dimensions for an axially
loaded lug:

h2 = 0.5 (w − D)

h1 = h4 = h2 + 0.5 D (1 − cos 45°)

h3 = a

It should be noted that h3 is defined as the smallest dimension on any radial section
around the hole, but it will typically be equal to a. From the above dimensions, the
effective edge distance is calculated:

The equation above is simply a "reciprocal


average" that gives more weighting to
dimension h1 since that section takes most of
the load. (Note 3)

Lug Strength Under Transverse Load

11/30
The ultimate transverse load is given by:

where D is the hole diameter and t


is the lug thickness. Fbru.L and Fbry.L
are the lug ultimate and yield
bearing stresses, respectively, and
are given by the following equations:

Ultimate Bearing Stress: Fbru.L = Ktru Stu

Yield Bearing Stress: Fbry.L = Ktry Sty

where Ktru and Ktry are the transverse ultimate and yield load coefficients and are
determined from the following plot:

Bushing Bearing Strength Under Transverse Load

The bearing strength for the bushing in a transversely loaded lug is the same as for an
axially loaded lug:

Ptru.B = Pu.B

where Pu.B is the bushing bearing strength for an axially loaded lug.

Design Strength Under Transverse Load

The design ultimate load for a transversely loaded lug is the minimum of the ultimate lug
load and the ultimate bushing load:

12/30
Ptru.L.B = min( Ptru.L , Ptru.B )

Oblique Loading

In an obliquely loaded lug, the applied load has both axial and transverse components, as
shown in the figure below:

For an obliquely loaded lug, the applied load should


be broken out into the axial and transverse
components, Pax and Ptr, and the strengths in the
axial and transverse directions should be calculated
as discussed in the previous sections. An allowable
load curve can then be defined which takes the form
of an interaction equation, and is given below:

The allowable load curve defines the limits at which


the lug is expected to fail -- it defines the ultimate load
for a given combination of applied axial and
transverse load. In the equation above, Pax.ult is
the axial component of the ultimate load, Ptr.ult is
the transverse component of the ultimate load,
Pu.L.B is the design strength under axial load, and Ptru.L.B is the design strength under
transverse load. The allowable load curve is shown below:

13/30
In the figure above, the values along the y-axis are the ratios of the transverse applied
load to the transverse strength, and the values along the x-axis are the ratios of the axial
applied load to the axial strength.

Axial Load Ratio Transverse Load Ratio

The point for the applied load with coordinates of (Rax , Rtr) should be plotted. Any point
that falls within the allowable load curve has a factor of safety ≥ 1 with respect to the
ultimate load. Note that if the applied load is completely axial, then the value for Rtr is 0
and the point (Rax , Rtr) lies along the x-axis, and so the ultimate load is simply the axial
design strength. Likewise for a completely transverse applied load; in this case, the point
lies along the y-axis and so the ultimate load is the transverse design strength.

For an applied load with both axial and transverse components, the ultimate load is
calculated by drawing a line from the origin, through the point (Rax , Rtr), and then through
the allowable load curve. This is the load line, and it has a slope of:

14/30
The ultimate load ratios are given by the intersection
of the load line with the allowable load curve. These
ultimate ratios can then be used to calculate the
ultimate load values in the axial and transverse
directions.

Ultimate Axial Load Ratio Ultimate Transverse Load Ratio

It should be noted that the equation for the slope given above disagrees with the slope
specified in the Air Force Manual. A discussion is given in the Appendix.

Instead of determining the ultimate values by plotting, they can be calculated directly by
noting that the ultimate load components, Pax.ult and Ptr.ult are related by:

Ptr.ult = Pax.ult · tan(α)

where α is the angle of the applied load with respect to the axial direction. (Note 4) The
equation defining the allowable load curve can then be solved for the ultimate axial load,
with the relationship above substituted for the ultimate transverse load:

The ultimate applied load can then be determined by:

The factor of safety is calculated by: (Note 5)

Double Shear Joint Strength


It is important for the pin in the joint to be strong enough that it will distribute the load
evenly over the lugs. Even though a weak pin will not commonly break in practice,
excessive flexure of the pin will cause the load to "peak up" near the shear planes such
that the outer edges of the lugs see high loads and the inner portions of the lugs are

15/30
relatively unloaded. This can cause the material around the holes on the outer surfaces of
the lugs to deform far enough to initiate a fracture, and the lug will fail at a lower load than
predicted.

One effect that helps the situation is that as the load concentrates near the shear planes,
the bending arm is reduced, and therefore the bending moment in the pin is reduced.
However, a study cited by Molcon and Hoblit found that this decrease in bending moment
is "seldom more than 25 percent and usually much less."

Since bending in the pin affects the strength of the lug, it is critical to account for the pin
strength when analyzing the joint. In this section, a method for calculating the allowable
load for a double shear joint is presented. An example of a double shear joint is shown
below:

In a double shear joint, there are two outer (female) lugs, a single inner (male) lug, and a
pin.

The overall process of determining the allowable load is illustrated in the diagram below:

16/30
Calculate Joint Strength Ignoring Pin Effects

Initially ignoring the effects of pin bending, calculate the ultimate load of each lug in the
joint using the methods described in the previous sections. Then calculate the nominal
ultimate joint load (which does not account for the pin strength):

Pu.J.nom = min( 2·Pult.F , Pult.M )

where Pult.M is the ultimate load for the male lug and Pult.F is the ultimate load for a single
female lug. Since there are 2 female lugs supporting the load, then the ultimate load with
respect to the female lugs is 2·Pult.F.

Calculate Pin Shear and Bending Strengths

The shear strength and the bending strength of the pin should both be calculated.

Pin Shear Strength

The ultimate shear load is calculated by:

where Dp is the pin diameter and Ssu.P is the ultimate shear


strength of the pin material. Note that twice the area is used
in calculating pin shear strength since there are two shear
planes.

17/30
Pin Bending Strength

The ultimate bending load is the applied load that would result in bending failure of the
pin, and is calculated by:

where Larm is the moment arm and Mu.P is the ultimate failing
moment for the pin. If the load is distributed evenly across the entire
width of the lugs, then the moment arm is calculated by:

where t1 is the thickness of a single female lug, t2 is the


thickness of the male lug, and g is the gap between the male
and female lugs when the male lug is centered between the
female lugs.

The ultimate failing moment for the pin is calculated by:

where Stu.P is the ultimate tensile strength of the pin


material and kb.P is the plastic bending coefficient.
According to the Air Force Manual, "the value of kb.P
varies from 1.0 for a perfectly elastic pin to 1.7 for a
perfectly plastic pin, with a value of 1.56 for pins made from reasonably ductile materials
(more than 5% elongation)."

Pin Strong or Weak in Bending?

Once the pin strengths are calculated, determine whether the pin is strong or weak in
bending. If the pin ultimate bending load (Pub.P) is greater than either the pin ultimate
shear load (Pus.P) or the nominal ultimate joint load (Pu.J.nom), then the pin is relatively
strong and is not critical in bending. Otherwise, the pin is weak and is critical in bending.

Pub.P ≥ Pu.J.nom or Pub.P ≥ Pus.P ? Yes → Strong Pin

No → Weak Pin

Strong Pin

If the pin is strong, the joint strength will be limited by either the pin shear strength or by
the nominal joint strength. In the case of a strong pin, the pin ultimate bending load is
calculated assuming that the load distributes evenly over the full width of the lugs:

The equation above is the same as the equation


presented earlier for the ultimate pin bending load, but
with the terms combined into a single equation.

18/30
For a strong pin, the pin bending does not affect the joint strength and the ultimate joint
load is equal to the nominal ultimate joint load:

Pu.J = Pu.J.nom

Weak Pin

If the pin is weak in bending, then the load will not be distributed evenly over the lug
widths. Instead, the load will concentrate toward the shear planes, and the inner portions
of the lugs will be relatively unloaded. Because of this, the lugs will fail at a lower load
than predicted.

To account for the low pin bending strength, a "balanced design" ultimate load is
calculated. The goal is to determine the actual bearing widths over which the lugs support
the load. Instead of the load being supported over the full lug thicknesses, t1 and t2, the
load will instead be distributed over some smaller widths, b1 and b2, as shown in the
figure below. It is assumed that the load is uniformly distributed over these widths.

Reducing the bearing width has two effects:

The ultimate load is reduced for the lugs (the lugs fail at a lower load).
The moment arm for the pin is reduced, which increases the pin's ultimate bending
load (the pin fails at a higher load).

The new, increased value of the pin ultimate bending load is calculated by:

19/30
where, in the equation above, b1 and 2·b2 were
substituted for t1 and t2 from the previous pin bending
equation.

The trick is to find the values of b1 and b2 that result in


the "balanced design" ultimate load. To determine the balanced design ultimate load,
reduce the bearing widths of each of the lugs until the ultimate load for the lugs are equal
to one other as well as equal to the ultimate bending load of the pin. This requires an
iterative process.

Once the balanced design ultimate load is found, the ultimate joint load and the pin
ultimate bending load are each equal to the balanced load:

Pu.J = Pub.P = Pbalanced

Calculate Allowable Load for Joint

The ultimate joint load (Pu.J) should have been calculated in one of the two previous
sections, depending on whether the pin was strong or weak in bending:

Strong pin: Pu.J = Pu.J.nom

Weak pin: Pu.J = Pbalanced

The overall ultimate load accounting for both the ultimate joint load and the ultimate pin
shear load is calculated by:

Pult = min( Pu.J , Pus.P )

The factor of safety is calculated by:

ASME BTH Method


The ASME method of lug analysis is described in ASME BTH-1, "Design of Below-the-
Hook Lifting Devices." This method considers the following failure modes, where the
numbers correspond to the figure:

1. Tension failure across the net section


2. Shear failure along two planes
3. Bearing failure
4. Fracture on single plane

20/30
While the factor of safety on dishing
(out-of-plane buckling) is not explicitly
calculated, the effective width
calculation accounts for the lug
thickness in an attempt to protect
against dishing failure.

The dimensions of interest for the lug


analysis are shown in the figure below:

The dimensions from the figure include:

Dh = hole diameter
Dp = pin diameter
be = net width (distance between the edge of the hole and the edge of the lug in the
transverse direction)
R = edge distance (distance from the center of the hole to the edge of the lug in the
direction of applied load)
r = radius of curvature of edge of lug (greater than or equal to R)
a = distance from the edge of the hole to the edge of the lug = R − 0.5 Dh
t = thickness (not shown in figure -- thickness is into the page)
Z = loss in shear plane length due to curvature at the end of the lug
ϕ = shear plane locating angle

Correction Factors

The analysis in ASME BTH is very similar to the simplified analysis, with the exception of
several correction factors that are calculated based on test results. These correction
factors are discussed below.

21/30
Strength Reduction Factor

The lug strength is reduced as the fit between the pin and the hole is loosened. The lug
strength is not much affected as long as the pin and hole are a relatively tight fit. ASME
defines a strength reduction factor that can be used to account for the pin-to-hole
clearance as:

where Dp is the pin diameter and


Dh is the hole diameter.

Shear Plane Locating Angle

A shear plane locating angle, ϕ, is used to locate the two planes along which shear tear
out occurs, as shown in the figure:

A larger value of ϕ results in a larger shear plane


area. Other methodologies commonly take ϕ as a
constant value (typically 40°), but ASME relates it
to the ratio of the pin diameter to the hole
diameter such that a loose-fitting pin has a
smaller shear plane area than a tight-fitting pin:

Effective Width

The term be is referred to as the net width and is the distance between the edge of the
hole and the edge of the lug in the transverse direction, as shown in the figure:

In the tension calculations, an effective width is


calculated and is the smallest of the following:

• beff.1 The effective width should not be


= be larger than the actual net width.

• beff.2 This limit is intended to protect


=4t against dishing failure (once the lug
thickness drops below 1/4 of the net
width be, the effective width is driven
down). This limit can be ignored if
the lug is stiffened or constrained
against buckling.

• This equation is empirical, fitted to


test results.

22/30
The effective width is calculated as:

beff = min( beff.1 , beff.2 , beff.3 )

Design Factor & Service Class

A design factor (i.e. required factor of safety), Nd, is used in the strength calculations. The
value for Nd can be found from the table below:

Design
Factor Condition

Nd = 2.00 Design Category A lifters (predictable loads, accurately defined or non-


severe environmental conditions, no more than 20,000 load cycles)

Nd = 3.00 Design Category B lifters (unpredictable loads, uncertain or severe


environmental conditions)

A service class is used to account for fatigue life and is defined based on the table below:

Service Class Load Cycles

0 0 - 20,000

1 20,001 - 100,000

2 100,001 - 500,000

3 500,001 - 2,000,000

4 Over 2,000,000

Lug Strength Calculations


These strength calculations are only applicable for axially applied loads, as indicated by
the applied force arrow in the figure below:

23/30
To determine whether the lug has sufficient strength, calculate a factor of safety for each
of the failure modes described below. As long as the applied force is within the allowable
load, and as long as each factor of safety is acceptable, then the lug can be considered to
pass.

Tensile Strength

The ultimate tensile load is the load that would result in tensile failure across the net
section, and is given by:

Pt.u = Cr Stu At

where Cr is the strength reduction factor and Stu is the ultimate tensile strength of the lug.
At is the area of the net section and is calculated by:

At = 2 t beff

where beff is the effective width and t is the lug thickness.

The allowable tensile load is based on the design factor, Nd, and is given by:

Note that the allowable tensile load is based on the design factor
multiplied by 1.20. ASME requires the design factor for some of the
strength calculations to be higher than the nominal value. The factor of
safety is given by:

To meet ASME BTH, the factor of safety must be at least 1.20·Nd, but the required factor
of safety may be larger depending on customer requirements or engineering judgement.

24/30
Single Plane Fracture Strength

The ultimate single plane fracture load is the load that would result in failure along the
plane collinear with the applied load, and is given by:

Pb.u = Cr Stu Ab

where Cr is the strength reduction factor and Stu is the ultimate tensile strength of the lug.
Ab is an effective area that is calculated as:

where R is the edge distance, Dh is the


hole diameter, be is the net width, and t is
the lug thickness.

The allowable single plane fracture load is based on the design factor, Nd, and is given
by:

The factor of safety is given by:

Double Plane Fracture Strength

The ultimate double plane shear load is the load that would result in shear tear out along
the two planes, and is given by:

Pv.u = 0.70 Stu Av

where Stu is the ultimate tensile strength of the lug. Av is the total area of the two shear
planes and is given by:

where ϕ is the shear plane locating angle


and Z is the loss in shear plane length due
to the curvature at the end of the lug. This
loss is calculated as:

Note that if the lug end is flat then r is infinity and Z


is zero.

The allowable double plane shear load is based on


the design factor, Nd, and is given by:

The factor of safety is given by:

25/30
Bearing Strength

The ultimate bearing load is the load that would result in bearing failure on either the lug
or the pin. This ultimate load is dependent on the number of load cycles that the
connection will be subjected to, and is given by:

where Sty.min is the minimum yield strength between the lug and the pin (i.e. Sty.min =
min(Sty.lug , Sty.pin)). The value Ap is the pin bearing area and is calculated by:

Ap = Dp t

The allowable bearing load is based on the design factor, Nd, and is given by:

The factor of safety is given by:

Appendix

Discrepancy With Air Force Manual - Oblique Loading

The Air Force Manual specifies to calculate the factor of safety for an obliquely loaded lug
by drawing a line from the origin that intersects with the allowable load curve, where the
slope of the line is given by:

where Pu.L is the ultimate load for an axially loaded lug and Ptru.L is the ultimate load for a
transversely loaded lug.

The problem with using the above equation for the slope is that the intersection line is the
same regardless of the angle of the applied force. This problem is illustrated in the figure
below:

26/30
If the applied force is at an angle of 5° such that it is almost entirely axial, then the point
for the applied load would lie along the blue line as shown in the figure, and the
intersection point should reflect a factor of safety that is very close to that of a pure axially
loaded lug. Likewise, if the applied force is at an angle of 85° such that it is almost entirely
transverse, then the point for the applied load would lie along the red line as shown in the
figure, and the intersection point should reflect a factor of safety that is very close to that
of a pure transversely loaded lug. Based on this reasoning, the slope of the line should
reflect the applied loading condition:

Notes

Note 1: Lug & Clevis Relative Sizing

It should be noted that the figure showing the lug with the clevis pin does not accurately
depict the relative sizing. The clevis pin should be a relatively tight fit in the lug. Per
ASME, the pin diameter should be at least 90% of the lug hole diameter to avoid a
reduction in the joint strength.

27/30
Note 2: Axial Load Coefficient Plot

The variable names used in the Axial Load Coefficient plot from the Air Force Manual are
inconsistent with the rest of the variable names throughout the manual. This plot
originated in Melcon & Hoblit, and the variable names from the plot were not updated to
match. The Air Force Manual uses the variable e for edge distance (center of hole to
edge of lug) and a for the distance between the edge of the hole to the edge of the lug.
However, the plot uses a for the edge distance (center of hole to edge of lug).

Note 3: Reciprocal Average for Transverse Lug Dimensions

The effective edge distance for a transversely loaded lug is calculated using a reciprocal
average. The effect of the reciprocal average is that the result is dominated by the smaller
terms such that a disproportionately large value will not drive up the average much, but a
disproportionately small value will drop the average significantly (i.e. a weak link -- this is
the same effect seen by placing springs in series). The use of this equation for calculating
the effective edge distance for a transversely loaded lug originated with Melcon and
Hoblit. They stated that the reason for the coefficient 3 on the h1 term was to reduce
scatter on their test data, but that it made sense because in a transversely loaded lug the
h1 section will be taking most of the load.

Note 4: Relationship Between Ultimate Load Components for Oblique Loading

To calculate the ultimate load components for an obliquely loaded lug, it is necessary to
determine a relationship between the ultimate components. It is known that the actual
load ratios are proportional to the ultimate load ratios since these ratios lie along the
same load line:

Express the ratios in terms of the load components and simplify:

The load components are related by the angle of the applied load:

Note 5: Factor of Safety for Oblique Loading

28/30
It should be noted that the factor of safety for an obliquely loaded lug can be incorporated
into the allowable load curve itself by:

The factor of safety can then be


calculated directly by:

Mailing List

Subscribe to receive occasional updates on the latest improvements:

References

Bruhn, "Analysis & Design of Flight Vehicle Structures"

Niu, "Airframe Stress Analysis"

29/30
30/30