50 MHz Analog-/Digital

Oscilloscope
HM507

Specifications and functions, see HM504-2


Automatic measurements
Digital mode:
Single, Refresh, Envelope, Average, Roll and XY modes

Low-Noise 8-bit Flash A/D Converters with max. 100 MSa/s


Real Time Sampling, 2 GSa/s Random Sampling and 2 kPts
Memory per Channel

Cursor measurement Pre-/Post-Trigger -10 cm to +10 cm

Digital Time Base 100 s – 100 ns/cm, with X Magnification up


to 20 ns/cm

Programmable Mathematical Signal Processing

Signal processing with


user-defined formulas
RS-232 interface for control and signal data transfer, incl.
Windows® software
Post/Pre-Trigger: -10 div. to + 10 div. (continuous)
Display Refresh Rate: max. 180/s
50 MHz Analog / Digital Oscilloscope HM507 Bandwidth: 2 x 0 – 50 MHz (-3 dB)
Valid at 23 °C after a 30 minute warm-up period Rise Time, Overshoot: ‹ 7 ns, ≤1 %
Signal Memory: 3 x 2 k x 8 bit
Reference Signal Memory: 3 x 2 k x 8 bit
Vertical Deflection Mathematical Signal Memory:3 x 2 k x 8 bit
Operating Modes: Channel I or II only Resolution (dots/div.) Yt Mode:X: 200/div., Y: 25/div.
Channels I and II (alternate or chopped) Resolution (dots/div.) XY Mode: X: 25/div., Y: 25/div.
Sum or Difference of CH I and CH II
Invert: CH II Operation / Readout / Control
XY Mode: via CH I (X) and CH II (Y) Manual: via controls
Bandwidth: 2 x 0 – 50 MHz (-3 dB) Autoset: automatic signal related parameter settings
Rise Time: ‹ 7 ns Save and Recall: 9 user defined parameter settings
Overshoot: max. 1 % Readout: display of menu, parameters, cursors
Deflection Coefficients: 1-2-5 Sequence and results
1 mV/div. – 2 mV/div.: ± 5 % (0 to 10 MHz (-3 dB)) Auto Measurements:
5 mV/div. – 20 V/div.: ± 3 % (0 to 50 MHz (-3 dB)) Analog mode: Frequency, Period, VDC, Vpp, Vp+, Vp-,
Variable (uncalibrated): › 2.5: 1 to › 50 V/div. also in digital mode: Vrms, Vaverage
Input Impedance: 1 MΩ II 18 pF Cursor Measurements:
Coupling: DC, AC, GND (ground) Analog mode: ∆V, ∆t, 1/∆t (f), tr, ∆V, V to GND, ratio X and Y
Max. Input Voltage: 400 V (DC + peak AC) also in digital mode: Pulse count, Vt related to Trigger Point,
Peak to Peak, Peak+, Peak-
Triggering Frequency counter: 4 digit (0.01 % ± 1 digit) 0.5 Hz – 100 MHz
Automatic (Peak to Peak): 20 Hz – 100 MHz (≥ 5 mm) Interface (standard fitting): RS-232 (Control, Signal Data)
Normal with Level Control: 0 – 100 MHz (≥ 5 mm) Interface Option: HO79-6 (IEEE-488, RS-232, Centronics)
Slope: positive or negative
Sources: Channel I or II, CH I/CH II alternate (≥ 8 mm) Component Tester
Line and External Test Voltage: approx. 7 Vrms (open circuit)
Coupling: AC (10 Hz – 100 MHz), DC (0 – 100 MHz), Test Current: max. 7 mArms (short-circuit)
HF (50 kHz – 100 MHz), LF (0 – 1.5 kHz) Test Frequency: approx. 50 Hz
Trigger Indicator: with LED Test Connection: 2 banana jacks 4 mm Ø
Triggering after Delay: with Level Control and Slope selection One test circuit lead is grounded via protective earth (PE)
External Trigger Signal: ≥ 0.3 VPP (0 – 50 MHz)
Active TV sync. separator: Field and Line, +/- Miscellaneous
CRT: D14-363GY, 8 x 10 cm with internal graticule
Horizontalablenkung (analog u. digital) Acceleration Voltage: approx. 2 kV
Analog Trace Rotation: adjustable on front panel
Time Base: 0.5 s/div. – 50 ns/div. (1-2-5 Sequence) Z-Input (Intens. modulation, analog): max. + 5 V (TTL)
Accuracy: ± 3% Calibrator Signal (Square Wave): 0.2 V ± 1 %, 1 Hz - 1 MHz (tr ‹ 4 ns), DC
Variable (uncalibrated): › 2.5 :1 to › 1.25 s/div. Power Supply (Mains): 105-253 V, 50/60 Hz ± 10 %, CAT II
X-Magnification x 10: up to 10 ns/div. (± 5 %) Power Consumption: approx. 42 Watt at 230 V/50 Hz
Accuracy: ± 5% Min./max. Ambient temperature: 0° C...+ 40° C
Delay (selectable): 140 ms – 200 ns (variable) Safety class: Safety class I (EN61010-1)
Hold-Off Time: variable to approx. 10 : 1 Weight: approx. 6.0 kg
XY Mode Dimensions (W x H x D): 285 x 125 x 380 mm
Bandwidth X amplifier: 0 – 3 MHz (-3 dB)
XY Phase shift ‹ 3°: ‹ 120 kHz
Digital
Time Base: 100 s/div. – 100 ns/div. (1-2-5 Sequence)
Accuracy: ± 2%
X Magnification x 10: up to 20 ns/div.
Accuracy: ± 2%
XY Mode
Bandwidth X Amplifier : 0 - 50 MHz (-3 dB)
XY Phase shift ‹ 3°: ‹ 10 MHz

Digital Storage
Operating Modes: Refresh, Roll, Single, XY, Envelope,
Average, Random Sampling Accessories supplied: Line Cord, Operators Manual and Software for
Interpolation: Linear Dot Join Function Windows on CD-ROM, 2 Probes 1:1 / 10:1
Sampling Rate (Real Time): max 100 MSa/s, 8 bit Flash A/D Converter Optional accessories: Multifunction Interface HO79-6, Opto Interface
Sampling Rate (Random): 2 GSa/s relative (with optical fiber cable) HZ70

w w w. h a m e g . co m
HM507E/310505/ce · Subject to alterations · © HAMEG Instruments GmbH · ® Registered Trademark · DQS-certified in accordance with DIN EN ISO 9001:2000, Reg.-No.: DE-071040 QM
HAMEG Instruments GmbH · Industriestr. 6 · D-63533 Mainhausen · Tel +49 (0) 6182 800 0 · Fax +49 (0) 6182 800 100 · www.hameg.com · info@hameg.com
A Rohde & Schwarz Company