0% found this document useful (0 votes)
101 views2 pages

Oscilloscope Specs for Engineers

This document describes two analog oscilloscopes, the HM1004-3 (100MHz) and HM2005 (200MHz). Both oscilloscopes have two input channels, autoset functions, and the ability to save and recall user settings. They provide voltage and time measurements and can be remotely controlled via RS-232. Key specifications include bandwidths of 100MHz and 200MHz, sampling rates of up to 5GS/s, and trigger functions to 200MHz and 300MHz respectively.

Uploaded by

ramonlim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
101 views2 pages

Oscilloscope Specs for Engineers

This document describes two analog oscilloscopes, the HM1004-3 (100MHz) and HM2005 (200MHz). Both oscilloscopes have two input channels, autoset functions, and the ability to save and recall user settings. They provide voltage and time measurements and can be remotely controlled via RS-232. Key specifications include bandwidths of 100MHz and 200MHz, sampling rates of up to 5GS/s, and trigger functions to 200MHz and 300MHz respectively.

Uploaded by

ramonlim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

OSCILLOSCOPE

Analog Oscilloscope HM1004-3 (100MHz) & HM2005 (200MHz)


Autoset, Save/Recall, Readout/Cursor and RS-232 Interface

 2 x DC to 100MHz (200MHz-HM2005) 2 x 1mV/div to 20V/div (5V/div-HM2005)


 Time Base A: 0.5s/div to 5ns/div (2ns-HM2005), Time Base B: 20ms /div to 5(2)ns/div
 Triggering DC to 200MHz (300MHz-HM2005), Peak Triggering; Component Tester
 1kHz/1MHz Calibrator, TV Sync Separator, Built in Adjustment Menu

These microprocessor controlled oscilloscopes have been designed for a wide


multitude of applications in service and industry. For ease of operation, the „Autoset“
function allows for signal related automatic setup of measuring parameters. On screen
alphanumeric readout and cursor functions for voltage, time and frequency meas-
urement provide extraordinary operational convenience. Nine different user defined
instrument settings can be saved and recalled without restriction.

The built in RS-232 serial interface permits remote controlled operation by a PC. The
outstanding features of the HM1004-3 and HM2005 include a second time base with
the ability to magnify, over 1000 times, extremely small portions of the input signal. The Screen shot of a 1MHz square wave and
second time base has its own triggering controls, to allow a stable and precisely 200MHz sine wave with alternate trigger
referenced display of asynchronous or jittery signal segments. The trigger circuit is
designed to provide reliable triggering to over 200MHz (300MHz/HM2005) at signal
levels as low as 0.5div. An active TV Sync Separator for TV signal tracing ensures
accurate triggering even with noisy signals.

The HM1004-3 and HM2005 have a built in switchable calibrator, which checks the
instrument’s transient response characteristics. The essential high frequency compen-
sation of wide band probes can be performed with this calibrator. The built in
adjustment menu allows closed case adjustment procedures. The instruments offer
the right combination of triggering control, frequency response, and time base versatility
to facilitate measurements in a wide range of applications - in laboratory as well as in Screen shot of a FBAS-Signal with burst,
field service use. It is another example of HAMEGs dedication to engineering excellence. displayed with 2.Timbase and 2.Trigger
230403

Accessories supplied: Operators Manual, PC-Software on CDR, 2 Probes 10:1 and Line Cord
10
OSCILLOSCOPE

Specifications Reference Temperature: 23°C ±2°C


2°C

Vertical Deflection HM1004-3 (100MHz) HM2005 (200MHz)


Operating modes: Channel I or II separate, Channel I or II separate,
Channel I and II: alternate or chopped Channel I and II: alternate or chopped
Chopper Frequency: approx. 0.5MHz approx. 0.5MHz
Sum or difference: from CH I and CH II from CH I and CH II
Invert: both channels both channels
XY-Mode: via channel I (Y) and channel II (X) via channel I (X) and channel II (Y)
Frequency range: 2x DC to 100MHz (-3dB) 2x DC to 200MHz (-3dB)
incl. Bandwidth Limiter: – 2x DC to approx. 50MHz (-3dB)
Min. Rise Time: < 3.5ns < 1.75ns
Overshoot: ≤1% ≤1%
Deflection coefficients: 14 calibrated steps 12 calibrated steps
1mV to 2mV/div.: ±5% (DC – 10MHz (-3dB)) 1mV to 2mV/div.: ±5% (DC – 10MHz (-3dB))
5mV/div. to 20V/div.: ±3% in 1-2-5 sequence 5mV/div. to 5V/div.: ±3% in 1-2-5 sequence
with variable 2.5:1 up to 50V/div. with variable 2.5:1 up to 12,5V/div.
Input impedance: 1MΩ II 15pF 1MΩ II 15pF
Input coupling: DC-AC-GD (ground) DC-AC-GD (ground)
Input voltage: max. 400V (DC + peak AC) max. 250V (DC + peak AC)
Delay line: approx. 70ns approx. 70ns
Triggering
Automatic (peak to peak): ≤ 20Hz-200MHz (≥ 0.5div.) ≤ 20Hz-300MHz (≥ 0.5div.
Normal with level control: DC-200MHz (≥ 0.5div.) DC-300MHz (≥ 0.5div.)
Indicator for trigger action: LED LED
Slope: positive or negative positive or negative
Sources: Channel I or II, line and external Channel I or II, line and external
ALT. Triggering: CH I/CH II (≥ 0.8div.) CH I/CH II (≥ 0.8div.)
Coupling: AC (10Hz – 200MHz) DC (0 – 200MHz) AC (10Hz – 300MHz) DC (0 – 300MHz)
HF (50kHz – 200MHz) LF (0 –1.5kHz) HF (50kHz – 300MHz) LF (0 –1.5kHz)
NR (noise reject): 0-50MHz (≥ 0.8div.) NR (noise reject): 0-50MHz (≥ 0.8div.)
Triggering time base B: normal with level control and normal with level control and
slope selection (0 – 200 MHz) slope selection (0 – 300 MHz)
Active TV Sync. Separator: field and line, + / – field and line, + / –
External: ≥0.3Vpp (0 – 100MHz) ≥0.3Vpp (0 – 200MHz)
Horizontal Deflection
Time base A: 22 calibrated steps (±3%) 23 calibrated steps (±3%)
from 0.5s/div. – 50ns/div. in 1-2-5 sequence from 0.5s/div. – 20ns/div. in 1-2-5 sequence
variable 2.5:1 up to 1.25s/div. variable 2.5:1 up to 1.25s/div.
X-Mag. x10: 5ns/div. (±5%) 2ns/div. (±5%)
Hold off time: variable to approx. 10:1 variable to approx. 10:1
Time base B: 18 calibrated steps (±3%) 19 calibrated steps (±3%)
from 20ms/div. to 50ns/div. in 1-2-5 sequence from 20ms/div. to 20ns/div. in 1-2-5 sequence
Operating modes: A or B, alternate A/B A or B, alternate A/B
Bandwidth X-amplifier: 0 – 3MHz (-3dB) 0 – 5MHz (-3dB)
Input X-amplifier: via Channel II via Channel I
Sensitivity: see CH II see CH I
X-Y phase shift: <3° below 220kHz <3° below 220kHz
Operation / Control
Manual: front panel switches front panel switches
Auto Set: automatic parameter selection automatic parameter selection
Save/Recall: 9 user-defined parameter settings 9 user-defined parameter settings
Readout: Display of parameter settings Display of parameter settings
Cursor measurement: ∆V, ∆t or ∆1/t (frequency) ∆V, ∆t or ∆1/t (frequency)
Remote control: with built in RS-232 interface with built in RS-232 interface
Component Tester
Test voltage: approx. 7Vrms (o/c) approx. 50Hz approx.. 7Vrms (o/c) approx. 50Hz
Test current: approx. 7mArms (s/c) approx. 50Hz approx.. 7mArms (s/c) approx. 50Hz
One test lead is grounded (Safety Earth) One test lead is grounded (Safety Earth)
General Information
CRT: D14-375GH, 8x10cm, internal graticule D14-375GH, 8x10cm, internal graticule
Acceleration voltage: approx. 14kV approx. 14kV
Trace rotation: adjustable on front panel adjustable on front panel
Calibrator: 0,2V ±1%, ≈ 1kHz/1MHz (tr <4ns) 0,2V ±1%, ≈ 1kHz/1MHz (tr <4ns)
Z-Input (Intensity modulation): – max. +5V (TTL)
Line Voltage / Power consumption: 100-240V AC ±10% / approx. 38Watt. 50/60Hz 100-240V AC ±10% / approx. 43Watt. 50/60Hz
Min./Max. ambient temperature: +10°C + 40°C +10°C + 40°C
Protective system: Safety class I (IEC1010-1) Safety class I (IEC1010-1)
Weight: approx. 5.9kg. approx. 5.9kg.
230403

Cabinet / Color: W 285, H 125, D 380 mm / techno-brown W 285, H 125, D 380 mm / techno-brown
Lockable tilt handle Lockable tilt handle