GP-PRO/PBIII for Windows
Device/PLC CONNECTION MANUAL
    Keyence Corporation PLC
Reading the GP-PRO/PBIII Device/PLC Connection Manual
     This document is designed as an addition to the latest GP-PRO/PBIII for Windows
     Device/PLC Connection manual's Keyence Corporation data.
     When connecting a Factory Gateway unit, please substitute the words "Factory
     Gateway" for this document's "GP/GLC/ST".
                                                                                  Keyence Corporation PLC
         2.18         Keyence
            2.18.1           System Structure
                 The following describes the system structure for connecting the GP to Keyence PLCs.
                                      The Cable Diagrams mentioned in the following tables are
                                      listed in the section titled "2.18.2 Cable Diagrams".
                KZ-300/KZ-350 Series (using Link I/F)
                       CPU                 Link I/F             Cable Diagram          Target Machine
                                                  PC Link
                                                     Unit
                KZ-300             KZ-L2                     RS-232C                   GP/GLC Series
                KZ-350                                       Port 1 Connection
                                                             (Cable Diagram 1)            ST401
                                                             RS-232C                   GP/GLC Series
                                                             Port 2 Connection
                                                             (Cable Diagram 2)            ST401
                                                             RS-422                    GP/GLC Series
                                                             Port 2 Connection
                                                             (Cable Diagram 3)            ST400
                     Port 1 and Port 2 can be connected at the same time on the GP. When
                     connected at the same time, the Communication Setup for Port 1 and Port
                     2 must be the same.
                KZ-A500 Series (using Link I/F)
                             CPU                  Link I/F             Cable Diagram              Target Machine
                KZ-A500                        KZ-L10          RS-232C - connected to Port 1       GP/GLC Series
                                                               (Cable Diagram 4)
                                                                                                        ST401
                                                               RS-232C - connected to Port 2       GP/GLC Series
                                                               (Cable Diagram 2)
                                                                                                        ST401
                                                                RS-422 - connected to Port 2       GP/GLC Series
                                                                    (Cable Diagram 3)
                                                                                                        ST400
                     Port 1 (RS232C), Port 2 (RS232-C or RS422) and the modular
                     controller on CPU unit can be used at the same time.
GP-PRO/PBIII for Windows Device/PLC Connection Manual                                                              1
Keyence Coporation PLC
                 KZ-A500 (CPU Direct Connection)
                          CPU                      Cables               Connector         Target Machine
                                                       Modular
                                         Modular
                KZ-A500                 Keyence Co.              Keyence Co.
                                                                                           GP/GLC Series
                                        OP-26487                 OP-26485 *1
                                                                 Keyence Co.
                                                                                              ST401
                                                                 OP-26486
                 *1 The above CPU cannot be directly connected to GP2300/GP2301/GLC2300
                    series units because of the connector cover size. In this case, use Digital’s
                    CA1-EXCBL/D25-01 extension cable between the connector and the GP/GLC.
                 Visual KV Series (CPU Direct Connection)
                         CPU                       Cables              Connector          Target Machine
                                                      Modular
                                                       Socket
                                        Modular
                                        Socket
                KV-10A,KV-10D
                                   *1   Keyence Co.              Keyence Co.
                                        OP-26487                                          GP/GLC Series
                KV-16A,KV-16D                                  OP-26485 *2
                KV-24A,KV-24D                                  Keyence Co.
                KV-40A,KV-40D                                  OP-26486                    ST401
                 *1 The value of  depends on the PLC specifications.
                 *2 The above CPU cannot be directly connected to GP2300/GP2301/GLC2300
                   series units because of the connector cover size. In this case, use Digital’s
                   CA1-EXCBL/D25-01 extension cable between the connector and the GP/GLC.
                 KV-700 Series (using Link I/F)
                          CPU                      Link I/F          Cable Diagram        Target Machine
                                        PC Link Unit
                KV-700                  KV-L20                   RS-232C                  GP/GLC Series
                                                                 (Communication Port 1)
                                                                 <Cable Diagram 5>            ST401
                                                                 RS-232C                  GP/GLC Series
                                                                 (Communication Port 2)
                                                                 <Cable Diagram 6>            ST401
                                                                 RS-422                   GP/GLC Series
                                                                 (Communication Port 2)
                                                                 <Cable Diagram 7>            ST400
2                               GP-PRO/PBIII for Windows Device/PLC Connection Manual
                                                                                 Keyence Corporation PLC
                KV-700/KV-1000 Series (CPU Direct Connection)
                          CPU                Cables                  Connector          Target Machine
                                                 Modular
                                   Modular
               KV-700              Keyence Co.                 Keyence Co.                             *2
               KV-1000             OP-26487                               *1           GP/GLC Series
                                                               OP-26485
                                                               Keyence Co.
                                                                                           ST401
                                                               OP-26486
                *1 The above CPU cannot be directly connected to GP2300/GP2301/GLC2300
                   series units because of the connector cover size. In this case, use Digital’s
                   CA1-EXCBL/D25-01 extension cable between the connector and the GP/GLC.
                *2 In the GP70 series units, only GP377 series units can be used.
                KV Series (CPU Direct Connection)
                          CPU                Cables                  Connector         Target Machine
                                               Modular
                                                Socket
                                  Modular
                                  Socket
               KV-10RW,KV-10T2W    Keyence Co.                 Keyence Co.
               KV-16RW,KV-16T2W    OP-26487                    OP-26485 *1             GP/GLC Series *2
               KV-24RW,KV-24T2W
               KV-40RW,KV-40T2W                                Keyence Co.
               KV-80RW,KV-80T2W                                OP-26486                    ST401
                *1 The above CPU cannot be directly connected to GP2300/GP2301/GLC2300
                   series units because of the connector cover size. In this case, use Digital’s
                   CA1-EXCBL/D25-01 extension cable between the connector and the GP/GLC.
                *2 GP70 Series (except for GP377 Series units) and GLC100 Series units can-
                   not be used.
                KV 1000 Series (Link I/F Connection)
                         CPU        Link I/F                      Cable                 Target Machine
                                  PC Link Unit
                KV-1000           KV-L20R             RS-232C Port 1 Connection         GP/GLC Series
                                                          (Cable Diagram 5)                 ST401
                                                      RS-232C Port 2 Connection         GP/GLC Series
                                                          (Cable Diagram 6)                 ST401
                                                         RS-422 Port 2 Connection       GP/GLC Series
                                                            (Cable Diagram 8)               ST400
GP-PRO/PBIII for Windows Device/PLC Connection Manual                                                       3
Keyence Coporation PLC
              2.18.2         Cable Diagrams
                  The cable diagrams illustrated below and the cable diagrams recommended by
                  Keyence may differ, however, using these cables for your PLC operations will not
                  cause any problems.
                   • Connect the FG line of the Shield cable to the GP.
                   • For the RS-232C connection, use a cable length less than 15m.
                   • If a communications cable is used, it must be connected to the SG
                     (signal ground).
                   • For the RS-422 connection, refer to Keyence's PLC manual for the
                     cable length.
                  Cable Diagram 1 (RS-232C)
                  GP/GLC Series Units
                                                     Shield
              GP Unit     1        FG                                         2     SD    PLC
              (25P)       2        SD                                         3     RD    (25P)
                          3        RD                                         4     RS
                          4        RS                                         5     CS
                          5        CS                                         7     SG
                          6        DR
                          7        SG
                          8        CD
                          20       ER
                  ST401 Unit
                                                     Shield
             ST Unit     Connector Shell                                     2     SD     PLC
             (9P)        3       SD                                          3     RD     (25P)
                         2       RD                                          4     RS
                         7       RS                                          5     CS
                         8       CS                                          7     SG
                         6       DR
                         5       SG
                         1       CD
                         4       ER
4                              GP-PRO/PBIII for Windows Device/PLC Connection Manual
                                                        Keyence Corporation PLC
                    Cable Diagram 2 (RS-232C)
                    GP/GLC Series Units
                                          Shield
          GP Unit     1        FG                          3    SD       PLC
          (25P)       2        SD                          5    RD       (25P)
                      3        RD                          1    SG
                      4        RS
                      5        CS
                      6        DR
                      7        SG
                      8        CD
                      20       ER
                    ST401 Unit
                                           Shield
            ST Unit
                                                                         PLC
            (9P)      Connector Shell                       3    SD      (25P)
                      3       SD                            5    RD
                      2       RD                            1    SG
                      7       RS
                      8       CS
                      6       DR
                      5       SG
                      1       CD
                      4       ER
GP-PRO/PBIII for Windows Device/PLC Connection Manual                            5
Keyence Coporation PLC
                 Cable Diagram 3 (RS-422)
                    Turn the PLC's Termination Resistor switch ON.
                    The reading of the A and B signals is reversed on the GP and PLC.
                 GP/GLC Series Units
                 • When using Digital's RS-422 connector terminal adapter, GP070-CN10-0
                 • When using Digital's RS-422 Cable, GP230-IS11-0
                 • When making your own cable connections
              Termination
              Resistance
              470Ω 1/2W
                 • Hirakawa Densen's H-9293A (C0-HC-ESV-3P*7/0.2) is the recommended
                   cable.
                 • When connecting the #9 and #10 pins in the GP Serial I/F, a termination
                                    Ω is added between RDA and RDB.
                   resistance of 100Ω
                 • When using RS-422 connection, please check the cable length with
                   Keyence PLC User manual.
6                           GP-PRO/PBIII for Windows Device/PLC Connection Manual
                                                                   Keyence Corporation PLC
                  ST400 Unit
                  • When using Digital's RS-422 cable CA3-CBL422/5M-01
                                                RDA                  1         SG        PLC
                                                RDB                  2         SDB
                                                SDA                  3         SDA
                                                SDB                  4         RDB
                   CA3-CBL422/5M-01             SG                   5         RDA
                                                FG
                                                                    Terminal Block No.
                                                          Ground
                  Be sure to connect the FG terminal to the ground. For information about
                  FG connections, refer to page 1-5 note *1, in the "Connecting a Device/PLC
                  to the ST unit."
                  • When making your own cable connections
                           ST Unit                                       PLC
                         (9P Female)       *1    Shield
                         Connector Shell
                             5 SG                                     1 SG
           Termination
           Resistance       1 RDA                                    2 SDB
           100Ω             2 RDB                                    3 SDA
           Termination      3 SDA                                    4 RDB
           Resistance       7 SDB                                    5 RDA
           470Ω 1/2W
                            6 CSB
                            9 ERB                                   Terminal Block No.
                            8 CSA
                            4 ERA
           *1 Be sure to connect the shield to the Connector Shell. For information about FG
              connections, refer to page 1-2 "RS422 I/F (ST400)" section's Note, in the "Con-
              necting a Device/PLC to the ST unit."
                  • Hirakawa Densen's H-9293A (C0-HC-ESV-3P*7/0.2) is the recommended
                    cable.
                  • When using RS-422 connection, please check the cable length with
                    Keyence PLC User manual.
GP-PRO/PBIII for Windows Device/PLC Connection Manual                                          7
Keyence Coporation PLC
                 Cable Diagram 4 (RS-232C) Port 1
                 GP/GLC Series Units
                 • When using an RS-232C cable, the cable must be no longer than 15meters.
                 • When using an RS-422 cable, the cable must be no longer than 500meters.
                         GP Unit                                           PLC
                         (25P)              Shield                         (25P)
                     1          FG                                     2           SD
                     2          SD                                     3           RD
                     3          RD                                     4           RS
                     4          RS                                     5           CS
                     5          CS                                     7           SG
                     7          SG
                 ST401 Unit
                         ST Unit                             PLC
                         (9P Female)         Shield          (25P)
                         Connector Shell
                         3 SD                                3 RD
                         2 RD                                2 SD
                         7 RS                                5 CS
                         8 CS                                4 RS
                         6 DR                                7 SG
                         5 SG
                         1 CD
                         4 ER
                 Cable Diagram 5 (RS-232C) Port 1
                 GP/GLC Series Units
                   GP Unit                                           PLC
                   (D-sub 25P Male)              Shield              (D-sub 9P Female)
                         1      FG                                    2            RD
                         2      SD                                    3            SD
                         3      RD                                    7            RS
                         4      RS                                    8            CS
                         5      CS                                    5            SG
                         6      NC
                         7      SG
                         8      CD
                         20     ER
8                               GP-PRO/PBIII for Windows Device/PLC Connection Manual
                                                         Keyence Corporation PLC
                ST401 Unit
                    ST Unit                           PLC
                  (D-sub 9P Female)   Shield        (D-sub 9P Female)
                    Connector Shell
                    3 SD                              2 RD
                    2 RD                              3 SD
                    7 RS                              8 CS
                    8 CS                              7 RS
                    6 DR                              5 SG
                    5 SG
                    1 CD
                    4 ER
                Cable Diagram 6 (RS-232C) Port 2
                GP/GLC Series Units
                 GP Unit                                     PLC Communication
                 (D-sub 25P Male)        Shield              Terminal Block
                    1        FG                                 1       SG
                    2        SD                                 3       SD
                    3        RD                                 5       RD
                    4        RS
                    5        CS
                    6        NC
                    7        SG
                    8        CD
                    20       ER
                ST401 Unit
                       ST Unit                     PLC Communication
                  (D-sub 9P Female)   Shield         Terminal Block
                    Connector Shell
                    3 SD                             3 SD
                    2 RD                             5 RD
                    7 RS                             1 SG
                    8 CS
                    6 DR
                    5 SG
                    1 CD
                    4 ER
GP-PRO/PBIII for Windows Device/PLC Connection Manual                            9
Keyence Coporation PLC
                  Cable Diagram 7 (RS-422) 4-wire type
                  • The termination resistance on the PLC side becomes active when
                    the Terminator Select switch on the unit is turned ON.
                  • The names of poles A and B are inverted between the GP and the
                    PLC.
                  • The cable length should be within 500 meters.
                  GP/GLC Series Units
                  • When using Digital's RS-422 connector terminal adapter, GP070-CN10-0
                                                                                               Terminal for
                       Termination resistance
                                                       GP Unit        Shield                  communication
                                  1/2W, 470Ω
                                                       RDA                                        1   SG
                                                       REB                                        2   REA
                           GP070-CN10-0
                                                       SDA                                        3   SDA
                                                       SDB                                        4   RDB
                                                       TERM                                       5   SDB
                         Termination resistance        SG
                                      1/2W, 470Ω       FG
                  • When using Digital's RS-422 Cable, GP230-IS11-0
                                                                                                Terminal for
                                                            GP Unit                           communication
                                                            RDA                                   1   SG
                                                            REB                                   2   RDA
                                                            SDA                                   3   SDA
                                                            SDB                                   4   RDB
                            GP230-IS11-0                    SG                                    5   SDB
                                                            FG
                                                                         Ground
                  • When making your own cable connections
                                                                                   Terminal for
                                             GP Unit         Shield               communication
                                         1    FG                                    1   SG
                                         7    SG                                    2   RDA
                                         9    TRMX                                  3   SDA
             Termination resistance
                                         10 RDA                                     4   RDB
                       470Ω, 1/2W        16 RDB                                     5   SDB
             Termination resistance      11 SDA
                       470Ω, 1/2W        15 SDB
                                         18 CSB
                                         19 ERB
                                         21 CSA
                                         22 ERA
10                           GP-PRO/PBIII for Windows Device/PLC Connection Manual
                                                                         Keyence Corporation PLC
                  ST400 Unit
                  • When using Digital's RS-422 cable CA3-CBL422/5M-01
                                                                                       PLC Communication
                                                GP Unit                                Terminal Block
                                                 RDA                                       1 SG
                                                 RDB                                       2 RDA
                                                 SDA                                       3 SDA
                                                 SDB                                       4 RDB
                                                 SG                                        5 SDB
                  CA3-CBL422/5M-01               FG
                                                                Ground
                  Be sure to connect the FG line to the FG terminal. For information about FG
                  connections, refer to page 1-5 note *1, in the "Connecting a Device/PLC to
                  the ST unit."
                  • When making your own cable connections
                         ST Unit                                         PLC Communciation
                         (9P)              *1          Shield            Terminal Block
                         Connector Shell
                         5 SG                                            1 SG
           Termination
           Resistance    1 RDA                                           5 SDB
           470Ω 1/2W     2 RDB                                           3 SDA
           Termination
                         3 SDA                                           4 RDB
           Resistance    7 SDB                                           2 RDA
           470Ω 1/2W     6 CSB
                         9 ERB
                         8 CSA
                         4 ERA
           *1 Be sure to connect the shield to the Connector Shell. For information about FG
              connections, refer to page 1-2 "RS422 I/F (ST400)" section's Note, in the "Con-
              necting a Device/PLC to the ST unit."
GP-PRO/PBIII for Windows Device/PLC Connection Manual                                                11
Keyence Coporation PLC
                  Cable Diagram 8 (RS-422) Port 2
                  • The Link Unit is equipped with termination resistance. When the ter-
                    minator selector switch is turned ON, termination resistance is inserted.
                    (Inserts 220Ω between SDA - SDB and RDA - RDB)
                  GP/GLC Series Units
                  • When using Digital's RS-422 connector terminal adapter, GP070-CN10-0
                                                                                                   PLC
                                                GP Unit
                     Termination                                      Shield                   Communication
                     Resistance 220 Ω
                                                     FG                                          Terminal
                                                     SG                                            1 SG
                                                    RDA                                           5 SDB
                                                    RDB                                           3 SDA
                                                    SDA                                           4 RDB
                         GP070-CN10-0
                                                    SDB                                           2 RDA
                     Termination
                     Resistance 220 Ω
                  • When making your own cable connections
                                  GP                                               PLC
                              (25P Male)                  Shield               Communication
                                 1 FG                                            Terminal
                                 7 SG                                              1 SG
         Termination            10 RDA                                            5 SDB
         Resistance 220Ω        16 RDB                                            3 SDA
         Termination            11 SDA                                            4 RDB
         Resistance 220Ω        15 SDB                                            2 RDA
                                18 CSB
                                19 ERB
                                21 CSA
                                22 ERA
                  ST400 Unit
                  • When making your own cable connections
                                  ST                                               PLC
                              (9P Female)      *1            Shield            Communication
                             Connector Shell                                     Terminal
                                 5 SG                                              1 SG
                                1 RDA                                             5 SDB
                                2 RDB                                             3 SDA
                                3 SDA                                             4 RDB
                                7 SDB                                             2 RDA
                                6 CSB
                                9 ERB
                                8 CSA
                                4 ERA
            *1 Be sure to connect the shield to the Connector Shell. For information about FG
               connections, refer to page 1-2 "RS422 I/F (ST400)" section's Note, in the "Con-
               necting a Device/PLC to the ST unit."
12                          GP-PRO/PBIII for Windows Device/PLC Connection Manual
                                                                                  Keyence Corporation PLC
             2.18.3              Supported Devices
                  The following describes the range of devices supported by the GP.
                  KZ-300/KZ-350 Series                                              Set up System Area here.
                         Device               Bit Address            Word Address            Particulars
               Input Relay                    00000 ~ 0009              00 ~ 00
                                                                                                           *1
                                              7000 ~ 17415             70 ~ 174
               Output Relay                   0500 ~ 0503               05 ~ 05
                                                                                                           *2
                                              7500 ~ 17915             75 ~ 179
               Help Relay                     0504 ~ 0915                   ---
               Internal Help Relay            1000 ~ 6915               10 ~ 69
               Special Help Relay             2000 ~ 2915               20 ~ 29                                 L/H
               Timer (contact)                T000 ~ T249                   ---
               Counter (contact)              C000 ~ C249                   ---
               Timer (current value)               ---                T000 ~ T249
               Counter (current value)             ---               C000 ~ C249
               Data Memory                         ---             DM0000 ~ DM9999
               Temporary Data Memory               ---               TM00 ~ TM31
               * 1 Address numbers *000~*400 are available for the bit device addresses,and
                   *0~*4 are available for the word addresses displayed.
                              Bit Address                    Word Address
                      addr 7000                                   70
                      addr 7001 to addr 7400                   71 to 74
                      addr 8000                                   80
                      addr 8100 to addr 8400                   81 to 84
                      addr 17000 to addr 17400                170 to 174
               * 2 Address numbers *500~*900 are available for the bit device addresses, and
                   *5~*9 are available for the word addresses displayed.
                               Bit Address                   Word Address
                       addr 7500                                  75
                       addr 7600 to addr 7900                  76 to 79
                       addr 8500                                  85
                       addr 8600 to addr 8900                  86 to 89
                       addr 17500 to addr 17900               175 to 179
GP-PRO/PBIII for Windows Device/PLC Connection Manual                                                                 13
Keyence Coporation PLC
                 KZ-A500 (CPU Direct Connection)
                                                                               Set up System Area here.
                             Device           Bit Address      Word Address            Particulars
                Input Relay                  X0000 ~ X07FF     X0000 ~ X07F0
                Output Relay                Y0000 ~ Y07FF      Y0000 ~ Y07F0
                Internal Relay              M0000 ~ M8191      M000 ~ M8176
                Latch Relay                  L0000 ~ L8191          ---
                Special Relay               M9000 ~ M9255      M9000 ~ M9240
                Annunciator                  F0000 ~ F2047     F0000 ~ F2032
                Link Relay                  B0000 ~ B0FFF           ---
                Timer (contact)             TS0000 ~ TS2047         ---
                Timer (coil)                TC0000 ~ TC2047         ---                              L/H
                Counter (contact)          CS0000 ~ CS1023          ---
                Counter (coil)             CC0000 ~ CC1023          ---
                Timer (current value)             ---         TN0000 ~ TN2047
                Counter (current value)           ---         CN0000 ~ CN1023
                Data Register                     ---          D0000 ~ D6143
                Special Register                  ---          D9000 ~ D9255
                Link Register                     ---         W0000 ~ W0FFF
                File Register                     ---          R0000 ~ R8191
14                                 GP-PRO/PBIII for Windows Device/PLC Connection Manual
                                                                         Keyence Corporation PLC
                          KZ-A500 (using Link I/F)
                                                                          Set up System Area here.
                       Device          Bit Address      Word Address              Particulars
        Input Relay                   X0000 ~ X07FF     X0000 ~ X07F0
        Output Relay                  Y0000 ~ Y07FF     Y0000 ~ Y07F0
        Internal Relay                M0000 ~ M8191     M0000 ~ M8176
        Latch Relay                   L0000 ~ L8191     L0000 ~ L8176
        Link Relay                    B0000 ~ B0FFF
        Annunciator Relay             F0000 ~ F2047     F0000 ~ F2032
        Special Relay                 M9000 ~ M9255     M9000 ~ M9240
        Timer (connect)              TS0000 ~ TS2047
        Timer (coil)                 TC0000 ~ TC2047                                            L/H
        Counter (connect)            CS0000 ~ CS1023
        Counter (coil)               CC0000 ~ CC1023
        Timer (current value)                          TN0000 ~ TN2047
        Counter (current value)                        CN0000 ~ CN1023
        Data Register                                   D0000 ~ D6143
        Link Register                                   W0000 ~ W0FFF
        File Register                                   R0000 ~ R8191
        Special Register                                D9000 ~ D9255
GP-PRO/PBIII for Windows Device/PLC Connection Manual                                                 15
Keyence Coporation PLC
                  Visual KV Series (KV-10A/KV-10D/KV-16A/KV-16D//KV-24A/
                 KV-24D/KV-40A/KV-40D)
                                                                             Set up System Area here.
                        Device                Bit Address      Word Address              Particulars
                                              00000 ~ 00915      000 ~ 009
            Input/Output Relay
                                              07000 ~ 17915      070 ~ 179
                                              01000 ~ 01915      010 ~ 019
            Internal AUX Relay
                                              03000 ~ 06915      030 ~ 069
            Special AUX Relay                 02000 ~ 02915      020 ~ 029                      *1
            Timer (contact)                    T000 ~ T249
            Counter (contact)                 C000 ~ C249
            High-Speed Counter                                                                  *2
                                              CTC0 ~ CTC3
            Comparator (contact)
            Timer (set value)                                  TS000 ~ TS249                           L/H
            Counter (set value)                                CS000 ~ CS249
            Timer (current value)                              TC000 ~ TC249
            Counter (current value)                            CC000 ~ CC249
            Data Memory                                       DM0000 ~ DM1999
            Temporary Data Memory                               TM00 ~ TM31
            Digital Trimmer                                      AT0 ~ AT1                      *2
            High-Speed Counter
                                                               CTH0 ~ CTH1
            (current value)
            High-Speed Counter
                                                               CTC0 ~ CTC3
            Comparator (set value)
                      *1 Some addresses are not available for writes.
                      *2 Not available for writes
16                                    GP-PRO/PBIII for Windows Device/PLC Connection Manual
                                                                          Keyence Corporation PLC
                     KV-700 Series (using the KZ-300 series protocol)
                                                                               Set up System Area here.
                         Device           Bit Address           Word Address              Particulars
           Input Relay                   00000 ~ 00009            000 ~ 000                      *1
           Output Relay                  00500 ~ 00503            005 ~ 005
           Internal AUX Relay            00504 ~ 00915            005 ~ 009
           Extended Input/Output Relay
                                         01000 ~ 59915            010 ~ 599
           Internal AUX Relay
           Control Relay                 60000 ~ 63915            600 ~ 639                      *2
           Timer (contact)                T000 ~ T511                                            *3
                                                                                                        L/H
           Counter (contact)             C000 ~ C511                                             *3
           Timer (current value)                                 T000 ~ T511                     *3
           Counter (current value)                               C000 ~ C511                     *3
           Data Memory                                      DM0000 ~ DM9999                      *4
           Temporary Data Memory                               TM000 ~ TM511
           Control Memory                                      TM0520 ~ TM4519                   *5
                     *1 PLC or GP data writing is not possible.
                     *2 GP cannot write data to any address.
                     *3 Only available when the timer command and the counter command exist in
                        the ladder program.
                     *4 The device range for the PLC is between DM0000 and DM19999, but ad-
                        dresses up to DM9999 are only accessible to the GP.
                     *5 Some addresses are not available for writes.
GP-PRO/PBIII for Windows Device/PLC Connection Manual                                                     17
Keyence Coporation PLC
                      KV-700 Series (using the KZ-A500 (link) protocol)
                                                                             Set up System Area here.
                         Device               Bit Address          Word Address            Remarks
           Input Relay                       X0000 ~ X0000         X0000 ~ X0000              *1*2
           Output Relay                      X0050 ~ X0053         X0050 ~ X0050                *2
           Internal AUX Relay                X0054 ~ X009F         X0050 ~ X0090                *2
           Control Relay                    M0000 ~ M3915          M0000 ~ M3904              *3*4
           Timer (contact)                   TS000 ~ TS511                                      *5
           Counter (contact)                CS000 ~ CS511                                       *5
           High-Speed Counter                                                                 *5*6   L/H
                                            CS512 ~ CS515
           Comparator (contact)
           Timer (current value)                                   TN000 ~ TN511                *5
           Counter (current value)                                CN000 ~ CN511                 *5
           High-Speed Counter                                                                   *5
                                                                  CN512 ~ CN513
           (current value)
           Data Memory                                            D00000 ~ D19999             *7*8
           Control Memory                                         D50000 ~ D53999             *7*3
                         *1 Data cannot be written to the PLC or to the GP unit.
                         *2 Addresses must be specified using hexadecimal numbers.
                         *3 Some addresses are not available for writes.
                         *4 For addresses, only multiples of 16 may be specified.
                         *5 Only available when the timer command, the counter command, and the high-
                            speed timer command exist in the ladder program.
                         *6 GP cannot write data to any address.
                         *7 Even if the file registers are registered as R50000 to R539999, similar device
                            addresses can be used, e.g., R51111 = D51111.
18                                   GP-PRO/PBIII for Windows Device/PLC Connection Manual
                                                                              Keyence Corporation PLC
           The following table describes device names displayed when selecting GP-PRO/PBIII
           for Windows screen editor's KZ-A500 (Link) Protocol, and their corresponding KV-
           700 Series device names.
                   KZ-A500 (LINK) Protocol                               KV-700
                            Input Relay                                Input Relay
                          (X000 ~ X009)                             (00000 ~ 00009)
                            Output Relay                              Output Relay
                          (X050 ~ X053)                             (00500 ~ 00503)
                           Internal Relay                       Internal Auxiliary Relay
                          (X054 ~ X09F)                             (00504 ~ 00915)
                           Special Relay                              Control Relay
                        (M0000 ~ M3915)                             (60000 ~ 63915)
                         Timer (Contact)                             Timer (Contact)
                        (TS000 ~ TS511)                              (T000 ~ T511)
                        Counter (Contact)                          Counter (Contact)
                        (CS000 ~ CS511)                              (C000 ~ C511)
            High-speed Counter Comparator (Contact)   High-speed Counter Comparator (Contact)
                        (CS512 ~ CS515)                             (CTC0 ~ CTC3)
                      Timer (Current Value)                      Timer (Current Value)
                        (TN000 ~ TN511)                              (T000 ~ T511)
                     Counter (Current Value)                   Counter (Current Value)
                        (CN000 ~ CN511)                              (C000 ~ C511)
               High-speed Counter (Current Value)        High-speed Counter (Current Value)
                        (CN512 ~ CN513)                             (CTH0 ~ CTH1)
                           Data Register                              Data Memory
                       (D00000 ~ D19999)                       (DM00000 ~ DM19999)
                         Special Register                           Control Memory
                       (D50000 ~ D53999)                         (CM0000 ~ CM3999)
GP-PRO/PBIII for Windows Device/PLC Connection Manual                                             19
Keyence Coporation PLC
                   KV-700 Series (CPU Direct Connection)
                                                                     Set up System Area here.
                         Device               Bit Address     Word Address        Particulars
             Input/Output Relay
                                              00000~59915        000~599
             Internal AUX Relay
             Control Relay                   CR0000~CR3915     CR00~CR39
             Timer (contact)                   T000~T511
             Counter (contact)                 C000~C511
             High-Speed Counter
                                              CTC0~CTC3                                   *1
             Comparator (contact)
             Timer (set value)                                 TS000~TS511                *2
             Counter (set value)                               CS000~CS511                *2
                                                                                                L/H
             Timer (current value)                             TC000~TC511                *2
             Counter (current value)                          CC000~CC511                 *2
             Data Memory                                     DM00000~DM39999
             Temporary Data Memory                            TM000~TM511
             Control Memory                                  CM0000~CM3999
             Digital Trimmer                                   TRM0~TRM7                  *2
             High-Speed Counter
                                                               CTH0~CTH1                  *2
             (current value)
             High-Speed Counter
                                                               CTC0~CTC3                  *2
             Comparator (set value)
                   *1 Not available for writes.
                   *2 32-bit device
20                                 GP-PRO/PBIII for Windows Device/PLC Connection Manual
                                                                     Keyence Corporation PLC
                 KV Series (KV-10RW/KV-10T2W/KV-16RW/KV-16T2W/KV-
               24RW/KV-24T2W/KV-40RW/KV-40T2W/KV-80RW/KV-80TW)
                                                                         Set up System Area here.
                     Device             Bit Address         Word Address            Particulars
           Input/Output Relay          00000 ~ 00915
                                                                                           *1
                                       01000 ~ 01915
           Internal AUX Relay
                                       03000 ~ 06915
                                                                                           *1
           Special AUX Relay           02000 ~ 02915
           Timer (contact)              T000 ~ T119
           Counter (contact)           C000 ~ C119
           High-Speed Counter                                                              *2
                                       CTC0 ~ CTC3
           Comparator (contact)
           Timer (set value)                               TS000 ~ TS119
                                                                                                  L/H
           Counter (set value)                             CS000 ~ CS119
           Timer (current value)                           TC000 ~ TC119
           Counter (current value)                         CC000 ~ CC119
           Data Memory                                    DM0000 ~ DM1999
           Temporary Data Memory                            TM00 ~ TM31
                                                                                           *2
           Analog Timer                                      AT0 ~ AT1
           High-Speed Counter
                                                            CTH0 ~ CTH1
           (current value)
           High-Speed Counter
                                                            CTC0 ~ CTC3
           Comparator (set value)
                   *1 Some addresses are not available for writes.
                   *2 Not available for writes
                       The device ranges available will depend on the PLC model used. Be
                       sure to check your PLC's manual prior to connecting it to the GP.
GP-PRO/PBIII for Windows Device/PLC Connection Manual                                               21
Keyence Coporation PLC
                    KV-1000 Series (Using KZ-A500 [LINK] Protocol)
                                                                               Set up System Area here.
                     Device                    Bit Address          Word Address           Remarks
                   Input Relay            X(Y)0000 to X(Y)000F   X(Y)0000 to X(Y)0000           *1*2
                  Output Relay            X(Y)0050 to X(Y)0057   X(Y)0050 to X(Y)0050             *2
                                          X(Y)0100 to X(Y)257F   X(Y)0100 to X(Y)2570             *2
                Internal AUX Relay
                                            M0000 to M8991         M0000 to M8976
                   Latch Relay               L0000 to L8991         L0000 to L8976
                  Control Relay            B00000 to B0027F                                       *3
                 Timer (Contact)           TS0000 to TS3999                                       *4
                Counter (Contact)          CS0000 to CS3999                                       *4
                                                                                                       L/H
          High-speed Counter Comparator
                                           CS4000 to CS4003                                     *4*5
                    (Contact)
              Timer (Current Value)                               TN0000 to TN3999                *4
             Counter (Current Value)                              CN0000 to CN3999                *4
               High-speed Counter
                                                                  CN4000 to CN4001                *4
                 (Current Value)
                  Data Memory                                     D00000 to D65534
                                                                   W0000 to W7FFE                 *2
              Extended Data Memory
                                                                  R00000 to R65534
                    *1 Data cannot be written to a device by either the PLC or the GP unit.
                    *2 Addresses must be specified using hexadecimal numbers.
                    *3 Some addresses are not available for writes. For details, please refer to your
                       Keyence manual.
                    *4 Only available when the timer command, the counter command, and the high-
                       speed timer command exist in the ladder program.
                    *5 Writing data from the GP will cause a Host Communication Error (02:06).
22                                 GP-PRO/PBIII for Windows Device/PLC Connection Manual
                                                                       Keyence Corporation PLC
                The following table shows the device display format used by GP-PRO/PBIII for
                Windows (KZ-A500[LINK]) and the equivalent format used for the KV-1000.
               KZ-A500[LINK] protocol device ranges and KV-1000 device ranges.
                         Device               KZ-A500(LINK) Protocol              KV-1000
                       Input Relay            X(Y)0000 to X(Y)000F            R00000 to R00015
                      Output Relay            X(Y)0050 to X(Y)0057            R00500 to R00507
                    Internal AUX Relay        X(Y)0100 to X(Y)257F            R01000 to R59915
                    Internal AUX Relay           M0000 to M8991              MR00000 to MR56115
                   Internal AUX Relay*1         M08992 to M15999             MR56200 to MR99915
                       Latch Relay               L0000 to L8991              LR00000 to LR56115
                      Latch Relay *1            L08992 to L15999             LR56200 to LR99915
                      Control Relay               B000 to B27F                CR0000 to CR3915
                     Timer (Contact)            TS0000 to TS3999               T0000 to T3999
                    Counter (Contact)           CS0000 to CS3999               C0000 to C3999
              High-speed Counter Comparator
                                                CS4000 to CS4003                CTC0 to CTC3
                        (Contact)
                  Timer (Current Value)         TN0000 to TN3999               T0000 to T3999
                 Counter (Current Value)        CN0000 to CN3999               C0000 to C3999
                   High-speed Counter
                                                CN4000 to CN4001                CTH0 to CTH1
                     (Current Value)
                      Data Memory               D00000 to D65534             DM00000 to DM65534
                                                 W0000 to W7FFE              FM00000 to FM32766
                 Extended Data Memory
                                                R00000 to R65534             EM00000 to EM65534
              High-speed Counter Comparator
                                                R84000 to R84003                CTC0 to CTC3
                     (Current Value) *1
                Temporary Data Memory *1        D70000 to D70511               TM000 to TM511
                    Index Register *1           D70601 to D70612                 Z01 to Z12
                    Digital Trimmer *1          D70800 to D70807                 AT0 to AT7
                    Control Memory *1           D80000 to D91998             CM00000 to CM11998
                *1 Device that cannot be set (entered) or accessed by the GP.
GP-PRO/PBIII for Windows Device/PLC Connection Manual                                             23
Keyence Coporation PLC
                    KV-1000 Series (Direct CPU connection)
                                                                              Set up System Area here.
                        Device                  Bit Address         Word Address         Remarks
                     Input Relay
                                              00000 to 59915        0000 to 0599
                 Internal Retain Relay
                    Control Relay            CR0000 to CR3915       CR00 to CR39
                  Internal AUX Relay        MR00000 to MR99915    MR000 to MR999
                     Latch Relay            LR00000 to LR99915     LR000 to LR999
                   Timer (Contact)            T0000 to T3999
                  Counter (Contact)           C0000 to C3999
            High-speed Counter Comparator
                                               CTC0 to CTC3                                    *1
                      (Contact)
                 Timer (Setting Value)                            TS0000 to TS3999             *2
                Counter (Setting Value)                           CS0000 to CS3999             *2
                Timer (Current Value)                             TC0000 to TC3999             *2 L/H
               Counter (Current Value)                            CC0000 to CC3999             *2
                    Data Memory                                  DM00000 to DM65534
              Extended Data Memory EM                            EM00000 to EM65534
              Extended Data Memory FM                            FM00000 to FM32766
               Temporary Data Memory                               TM000 to TM511
                   Control Memory                                CM00000 to CM11998
                    Index Register                                   Z01 to Z12                *3
                    Digital Trimmer                                TRM0 to TRM7                *2
                  High-speed Counter
                                                                    CTH0 to CTH1               *2
                    (Current Value)
            High-speed Counter Comparator
                                                                    CTC0 to CTC3               *2
                     (Setting Value)
                  *1 Data write is not possible.If data write is attempted, a Host communication
                     error (02:02) will appear.
                  *2 32-bit device
                  *3 Do not write to Z11, Z12. These are reserved for PLC system use.
24                               GP-PRO/PBIII for Windows Device/PLC Connection Manual
                                                                                         Keyence Corporation PLC
             2.18.4          Environment Setup
                 The following lists Digital's recommended PLC and GP communication setups.
                 KZ-300/KZ-350 Series
                                   GP Setup                                         PC Link Unit Setup
               Baud Rate                    19200 bps        Baud Rate                            19200 bps
               Data Length                  7 bits           Data Bit                             7 bits
               Stop Bit                     2 bits           Stop Bit                             2 bits
               Parity Bit                   Even             Parity Bit                           Even
               Data Flow Control            ER Control                                      ---
               Communication Format                          Port 2 Toggle Switch
                                            RS-232C                            *1
                                                                                                  RS-232C
               (RS-232C)                                     (RS-232C)
               Communication Format                          Port 2 Toggle Switch
                                            4-wire type                   *1
                                                                                                  RS-422A
               (RS-422)                                      (RS-422)
                                      ---                    RUN Mode                             Link Mode
               Unit No.                     0                Station Number                       0
                 *1 Setup not necessary when using Port1.
                 KZ-A500 (CPU Direct Connection)
                                   GP Setup                                             PLC Setup
               Baud Rate                    9600 bps                                        ---
               Data Length                  8 bits (fixed)                                  ---
               Stop Bit                     1 bit (fixed)                                   ---
               Parity Bit                   Odd (fixed)                                     ---
               Data Flow Control            ER Control                                      ---
               Communication Format
                                            RS-232C                                         ---
               (RS-232C)
               Unit No.                     0 (fixed)                                       ---
                      Effect of PLC program on cycle time
                      If the KZ-A500 is connected directly to the CPU, the
                      cycle time of the PLC program is delayed by about
                      8% after communication with the GP begins.
GP-PRO/PBIII for Windows Device/PLC Connection Manual                                                         25
Keyence Coporation PLC
                       KZ-A500 (using Link I/F)
                               GP Setup                                           PLC Setup
        Baud Rate                              *1    Baud Rate                         19200bps
                                   19200bps
        Data Length                7 bits            Data Length                       7 bits
        Stop Bit                   1 bit             Stop Bit                          1 bit
        Parity Bit                 None              Parity Bit                        None
        Data Flow Control          ER
        Communication Format                                                                              *2
                                   RS-232C           RS-232C Communication Port        Port 1 or Port 2
        (RS-232C)
        Communication Format                                                                    *3
                                   4-Wire Type       RS-422 Communication Port         Port 2
        (RS-422)
                                                     Communication Type                Normal
                                                     Changing device data during RUN   Possible
                                                     Checksum                          Yes
                                                     Operation Mode                    Protocol Mode 4
        Unit No.                   0                 STATION No.                       0
                       *1 The maximum baud rate is 38400bps.
                       *2 When using an RS-232C cable on port 2, be sure to set the INTERFACE
                         switch to “232C”(right side setting.) Also, set the TERMINATOR switch to
                         OFF, since it will not be used.
                       *3 When using an RS-422 cable, set the INTERFACE switch to “422”( left side
                         setting,) and the TERMINATOR switch to ON.
                       Visual KV/KV-700/KV1000 Series (CPU Direct Connection)
                               GP Setup                                          PLC Setup
        Baud Rate                  19200bps
        Data Length                8 bits (fixed)
        Stop Bit                   1 bit (fixed)
        Parity Bit                 Even (fixed)
        Data Flow Control          ER Control
        Communication Format       RS-232C
        Unit No.                   0
                       • The KV/KV700 baud rates can be from 9600 to 57600 bps. The KV1000
                         baud rate can be from 9600 to 115200bps.
                       • The PLC requires no setup due to its automatic recognition of settings.
26                                     GP-PRO/PBIII for Windows Device/PLC Connection Manual
                                                                         Keyence Corporation PLC
                      KV-700 Series (using the KZ-300 series protocol)
                              GP Setup                                   PLC Setup
       Baud Rate                             *1   Baud Rate                   19200bps
                                  19200bps
       Data Length                7 bits          Data Length                 7 bits
       Stop Bit                   2 bits          Stop Bit                    2 bits
       Parity Bit                 Even            Parity Bit                  Even
       Data Flow Control          ER Control      RS, CS Flow Control         No
                                                  Communication Port 1        Fixed to 232C
       Communication Format
                                  RS-232C         Communication Port 2
       (RS-232C)                                                              232C
                                                  Selector Switch
       Communication Format                       Communication Port 2
                                  4-Wire Type                                 422A
       (RS-422)                                   Selector Switch
                                                  Operation Mode              Link Mode
       Unit No.                   0               Station No.                 0
                      *1 The maximum baud rate is 115,200 bps.
                      KV-700 Series (using the KZ-A500 series protocol)
                              GP Setup                                   PLC Setup
       Baud Rate                             *1   Baud Rate                   19200bps
                                  19200bps
       Data Length                7 bits          Data Length                 7 bits
       Stop Bit                   1 bits          Stop Bit                    1 bits
       Parity Bit                 None            Parity Bit                  None
       Data Flow Control          ER Control
                                                  Communication Port 1        Fixed to 232C
       Communication Format
                                  RS-232C         Communication Port 2
       (RS-232C)                                                              232C
                                                  Selector Switch
       Communication Format                       Communication Port 2
                                  4-Wire Type                                 422A
       (RS-422)                                   Selector Switch
                                                  Operation Mode              Protocol Mode 4
                                                  Checksum                    Yes
       Unit No.                   0               Station No.                 0
                      *1 The maximum baud rate is 115,200 bps.
GP-PRO/PBIII for Windows Device/PLC Connection Manual                                           27
Keyence Coporation PLC
                            KV Series (CPU Direct Connection)
                               GP Setup                                       PLC Setup
        Baud Rate                  19200bps
        Data Length                8 bits (fixed)
        Stop Bit                   1 bit (fixed)
        Parity Bit                 Even (fixed)
        Data Flow Control          ER Control
        Communication Format       RS-232C
        Unit No.                   0 (fixed)
                       • The baud rate can be from 9600 to 38400 bps.
                       • The PLC requires no setup due to its automatic recognition of settings.
                       • If your ladder program is currently stopped and you attempt data transfer
                         at 38400 bps, a communication error can occur. If it does, either change to
                         RUN mode, or use a different communication speed.
                       KV-1000 Series (Using KZ-A500 [LINK] Protocol)
                              GP Settings                                    PLC Settings
        Baud Rate                              *1    Baud Rate                      19200bps
                                   19200bps
        Data Length                7 bits            Data Length                    7 bits
        Stop Bit                   1 bit             Stop Bit                       1 bit
        Parity Bit                 None              Parity Bit                     None
        Data Flow Control          ER Control
                                                     Communication Port 1           Fixed to RS-232C
        Communication Format
                                   RS-232C           Communication Port 2
        (RS-232C)                                                                   RS-232C
                                                     Selector Switch
        Communication Format                         Communication Port 2
                                   4-Wire Type                                      RS-422A/485
        (RS-422)                                     Selector Switch
                                                     Operation Mode                 Protocol Mode 4
                                                     Checksum                       Yes
                                                     Transfer Timeout Time          3
        Unit No.                   0                 Station No.                    0
                       *1 Baud rate can be set as high as 115,200bps.
                       • Data transfer port 1 is fixed at RS-232C.
                            Communication Port 2 can be set to either RS-232C or RS-422A/485. Use
                            the selector switch on the side of the unit to set the communication for-
                            mat.
28                                     GP-PRO/PBIII for Windows Device/PLC Connection Manual
                                                                               Keyence Corporation PLC
             2.18.5        Error Codes
               PLC Error Codes
                Controller error codes are indicated by the "Host communication error (02:**)",
                and appear in the left lower corner of the GP screen. (** stands for an error code.)
                           Host Communication Error (02:**)
                                                                              PLC Error Code
              Visual KV/KV-700 Series/KV1000 (CPU Direct Connection)
                <PLC Error Code>
                 Error Code                                Description
                                Occurs when you write to a device that cannot be written to.
                      02
                                (High Speed Counter Comparator (contact))
                      04        Occurs when the PLC uses an unsupported baud rate to send data.
                                                                                *1
                      31        Occurs when an undefined device is accessed.
                *1 When writing to a Timer (contact/current value/set value), Counter (contact/
                   current value/set value), High Speed Counter, High Speed Counter Compara-
                   tor (set value), these values must be set in advance using a Ladder Program.
               KV Series (CPU Direct Connection)
                  <PLC Error Code>
                 Error Code                                Description
                      02        A ladder program has not yet been set up in the PLC.
                      04        A Device was accessed that has not yet been defined.
                                Setting values were attempted to be changed for a write-protected
                      13
                                program's Counters, Timers, and High-speed Counter Comparator.
GP-PRO/PBIII for Windows Device/PLC Connection Manual                                               29