Ashcroft® Miniature Pressure Switches      Page: SW/PI-77
PRODUCT INFORMATION
                             CONVERTING OLD A-SERIES PART NUMBERS TO THE
                                     NEW A-SERIES PART NUMBERS
With the release of the New A-series product family, Ashcroft will be discontinuing the old A-series
product family and part numbers. This guide is intended to easily convert the old part numbers to the
new part numbers. The new A-series has more configurations and ranges available than the old A-
series. There now may be more than one possible conversion or there is a feature that could be added
to make the switch better for its intended application. It is best practice to break down the old part
number to its specifications and then build a new part number based on the application requirements.
        1. Break down the old part number to its function, enclosure, micro switch, electrical
           connection, actuator seal, pressure connection, options and range.
        2. Review the application and electrical requirements.
        3. Review Old A-series to New A-series conversion table and build a new A-series part
           number.
OLD A-SERIES PRODUCT CODING:
           Part Number                    APS NS    D L S        02 X6B 30#
           1. Function:
           2. Enclosure:
           3. Micro Switch:
           4. Electrical Connection:
           4. Actuator Seal:
           5. Pressure Connection:
           6. Options:
           7. Pressure Range:
           1. Function:
              APS – A-series pressure switch, single setpoint, fixed deadband, factory set only, not field
                    adjustable
              APA – A-series pressure switch, single setpoint, fixed deadband, field adjustable
           2. Enclosure:
              RB – Watertight Brass body with polycarbonate switch seal
              RS – Watertight 304 Stainless Steel Body with polycarbonate switch seal
              NS – Watertight 304 Stainless Steel Body with glass to metal switch seal
              N7 – Explosion Proof 304 Stainless Steel Body with glass to metal switch seal
© Ashcroft Inc. 02/2012 SW/PI-77 Page 1
          3. Micro Switch:
             D – General Purpose 5A @ 125/250 VAC, 5A @ 28 VDC resistive, 3A @ 28 VDC inductive
             M – Gold Contacts 1A @125 VAC, 1A @ 28 VDC resistive, 0.5A @ 28 VDC inductive
          4. Electrical Connection:
             L – Wire leads, 3-18 AWG PVC insulated wires 12” length
             S – Screw terminals, 3 - #6 binding head screws
             T – Spade terminals, 3 - 0.187” male spade
             C – ½” NPT male conduit connection with 3-18 AWG PVC insulated wires 12” length
             H – Micro DIN Connector – Watertight DIN 43650 cable socket
          5. Actuator Seal:
             B – Buna Diaphragm and O-ring
             V – Viton Diaphragm and O-ring
             T – Teflon Diaphragm and O-ring
             S – 316 Stainless steel welded Diaphragm
             H – 304 Stainless steel piston with Viton O-ring
          6. Pressure Connection:
             01 – 1⁄8” NPT Male
             02 – ¼” NPT Male
             03 – 1⁄8” NPT Female
             04 – ¼” NPT Female
             05 – 7⁄16-20 SAE Male
             06 – VCR – Fixed
             07 – VCO – Fixed
             09 – 0.75” Tri-clamp connection
          7. Options:
             XC4 – Individual certified calibration chart
             XFS – Factory Set (APA models only)
             XFP – Fungus proofing
             XLE – Long Leads – 6’ standard, other lengths can be called out
             XMD– Metric range on Label
             XMQ– Positive Material Identification
             XNC – 2 wire leads - wired for normally closed operation
             XNO – 2 wire leads - wired for normally open operation
             XNH – Stainless Steel Tag
             XNN – Paper Tag
             X3A – 3A approval for 1.5” or 2.0” Tri-clover connection
             X6B – Cleaned for Oxygen service
          Notes:
          The X character will only appear before the first option, additional options will just be the two
          characters. Example: XFSLENH. If the switch is mounted to a seal the seal fill fluid is also listed
          as an X option.
© Ashcroft Inc. 02/2012 SW/PI-77 Page 2
          8. Pressure Range:
             –30 IMV (Brass body only)
             –30 IMV/15# (Stainless steel body only)
             15# (Brass body only)
             30#
             60#
             100#
             200#
             400#
             600#
             1000#
             2000#
NEW A-SERIES PRODUCT CODING:
-
          Part Number                     APS N4 1H 012L S 02 30# - 15 R –X6B
            1. Function:
            2. Enclosure:
            3. Micro Switch:
            4. Electrical Connection:
            5. Actuator Seal:
            6. Pressure Connection:
            7. Pressure Range:
            8. Setpoint:
            9. Setpoint Direction:
          10. Options:
          1. Function:
             APS – A-series pressure switch, single setpoint, fixed deadband, factory set only, not field
                   adjustable
             APA – A-series pressure switch, single setpoint, fixed deadband, field adjustable
          2. Enclosure:
             N4 – Watertight 316 Stainless Steel Body
             N7 – Explosion Proof 316 Stainless Steel Body, (requires electrical connection C)
© Ashcroft Inc. 02/2012 SW/PI-77 Page 3
          3. Micro Switch:
          First Character:
             1 – Single switch – SPDT
             2 – Dual switch - DPDT
          Second Character:
             G – Gold Contact – 0.1 A @ 125 VAC. 0.1 A @ 30 VDC
             H – Higher Current - 5A @ 125/250 VAC, 5A @ 28 VDC resistive, 3A @ 28 VDC inductive
             L – Higher Current Gold Contacts - 1A @125 VAC, 1A @ 28 VDC resistive, 0.5A @ 28 VDC
                  Inductive
             P – General Purpose – 3A @ 125 VAC, 2A @30 VDC
          4. Electrical Connection:
             012C – ½˝ NPT male conduit connection with 3-18 AWG PVC insulated wires 12” length
             000H – Micro DIN Connector – Watertight DIN 43650 cable socket without mating connector.
             00MH– Micro DIN Connector – Watertight DIN 43650 cable socket with mating connector.
             012L – Wire leads, 3-18 AWG PVC insulated wires 12” length
             000N – Nonstandard, customer specified see # Variation
             000T – Spade terminals, 4 - 0.187˝ male spade
          Note: The three numeric digits represent the length of wire in inches
          5. Actuator Seal:
             B – 316 Stainless Steel piston and Buna O-ring
             V – 316 Stainless Steel piston and Viton O-ring
             S – 316 Stainless steel welded Diaphragm
          6 Pressure Connection:
            01 – 1⁄8” NPT Male
            02 – ¼” NPT Male
            03 – 1⁄8” NPT Female
            25 – ¼” NPT Female
            05 – 7⁄16-20 SAE Male
            06 – VCR – Fixed
            07 – VCO – Fixed
            75 – 0.75” Tri-clamp connection (includes 3A Approval)
            15 – 1.5” Tri-clover connection (includes 3A Approval)
            20 – 2.0” Tri-clover connection (includes 3A Approval)
          7. Pressure Range:
             Actuator              PSI     Bar        kPa        Kg/cm2
                 S             –15/15#    –1/1BR   –100/100KP   –1/1KSC
                 S                30#       2BR       200KP       2KSC
                 S                60#       4BR       400KP       4KSC
                 S               100#       7BR       700KP       7KSC
              B, S, V           200#       14BR      1400KP      14KSC
               B, V              500#      35BR      3500KP      35KSC
               B, V             1000#      70BR      7000KP      70KSC
               B, V             2000#     140BR     14000KP     140KSC
               B, V             5000#     350BR     35000KP     350KSC
               B, V             7500#     500BR     50000KP     500KSC
© Ashcroft Inc. 02/2012 SW/PI-77 Page 4
            8. Setpoint:
               5 characters maximum representing setpoint of the switch in the same units as the range of
               the switch. For setpoints in Vacuum specify as “– “pressure.
            9. Setpoint Direction:
               R – Rising Pressure (Increasing Pressure)
               D – Decreasing Pressure
               Note: If no setpoint is required on an APA switch use either “NSR” or “NSD.” If direction is
               not known use “NSR” as the default.
          10. Options:
              XC4 – Individual certified calibration chart
              XBP – Mounting Bracket
              XFP – Fungus proofing
              XMQ – Positive Material Identification (75, 15 & 20 process connections only)
              XNC – 2 wire leads – wired for normally closed operation
              XNO – 2 wire leads – wired for normally open operation
              XNH – Stainless Steel Tag
              XNN – Paper Tag
              X6B – Cleaned for Oxygen service
                Notes:
                The X character will only appear before the first option, additional options will just be the
                two characters. Example: XFSLENH. If the switch is mounted to a diaphragm seal the seal
                fill fluid is also listed as an X option.
© Ashcroft Inc. 02/2012 SW/PI-77 Page 5
                             OLD A-SERIES TO NEW A-SERIES CONVERSION TABLE
                                  Old A-series   New A-series                 Comments
               Function              APA         APA
                                     APS         APS
               Enclosure              RB          N4
                                      RS          N4
                                      NS          N4
                                      N7          N7
               Switch                  D      1H or 1P          Check electrical requirement
                                       M      1L or 1G          Check electrical requirement
               Electrical              L         012L
               Connection              T         000T
                                       C         012C
                                       H        00MH
                                       S                        No longer available
               Actuator                B           S            Range ≤100#
               Seal                    B           B            Range ≥200#
                                       V           S            Range ≤100#
                                       V           V            Range ≥200#
                                       T           S            Range ≤100#
                                       T        B or V          Range ≥200#, check media compatability
                                       S           S            Range ≤200#
                                       S        B or V          Range ≥200#, check media compatability
                                       H           V
               Process                01          01
               Connection             02          02
                                       03         03
                                       04         25
                                       05         05
                                       06         06
                                       07         07
                                       09         75
               Range                30IMV      –15/15#
                                  30IMV/15#    –15/15#
                                      15#      –15/15#
                                      30#         30#
                                      60#         60#
                                     100#        100#
                                     200#        200#
                                     400#        500#
                                     600#   500# or 1000#       Depending setpoint
                                    1000#       1000#
                                    2000#       2000#
               Options                C4          C4
                                      FS                        Add setpoint to part number
                                      FP          FP
                                      LE                        Add long length to Electrical Connection (Ex. 072L)
                                     MD                         Not required order in Metric Range
                                     MQ          MQ
                                      NC          NC
                                     NO           NO
                                     NH           NH
                                     NN           NN
                                      3A                        Not required order 75, 15, or 20 connection
© Ashcroft Inc. 02/2012 SW/PI-77 Page 6
Examples of Old Part numbers converted to new part numbers
       Old A-series Part Number           New A-series Part Number
       APSRBDLB0215#                      APSN41HLS02-15/15#-5R or APSN41P012LS02-15/15#-5R
       Set at 5 PSI Increasing
       APARBMTT01XFS200#                  APAN41L000TS01200#-80D or APAN41G000TS01200#-80D
       Set at 80 PSI Decreasing
       APSRSDHS04100#                     APAN41H000HS25100#-75R or APAN41P000HS25100#-75R
       Set at 75 PSI Increasing
       APANSMLH05XFS6B1000#               APAN41L012LV051000#-675D-X6B or
       Set at 675 Decreasingr             APAN41G012LV051000#-675D-X6B
       APSN7DCS09XMQ60#                   APSN71H012CS7560#-40R-XMQ or
       Set at 40 PSI Increasing           APSN71P012CS7560#-40R-XMQ
       APAN7MCH021000#                    APAN71L012CV021000#-NSR or APAN71G012CV021000#-NSR
          Notes:
          1. Selection of the Micro switch should be based on the electrical requirements of the
             application. If they are not known use the H micro switch in place of a D micro switch or an
             L micro switch in place of a M micro switch.
          2. Always verify the compatibility of the actuator seal material and the application media.
          3. The electrical connection “S” screw terminal has been discontinued. Choose one of the other
             electrical connection choices. The micro DIN connector does have screw terminals for wire
             termination inside of the connector plug housing.
          4. Make sure the setpoint is called out in the part number if using an APS switch.
© Ashcroft Inc. 02/2012 SW/PI-77 Page 7