Orion Instruments Catalogues
Orion Instruments Catalogues
MT High Range
Pressure Switches
CATALOGUE
No. Description
1. Pressure housing (SS 316)
2. Diaphragm (Teflon)
3. Plunger
4. Steel ring (SS 316)
5. 'O' ring (Teflon)
6. Disc
6
5
4
3
2
Note : wetted parts are mentioned in italics. 1 *Presure ports are brazed with flange
INSTALLATION DRAWING
MOUNTING HOLES, Ø7
2 NOS 130.0
98.0 (5.11)
(3.85)
(3.42)
87
(4.64)
(2.0)
(2.0)
118
51
51
(4.84)
(1.22)
31
31
Range Code Range bar (psi) †Differential bar (psi) Maximum Working
Approximate Pressure bar (psi)
Maximum
for "A1"
microswitch
0.067 - 0.213 0.02 5
LP (0.97 - 3.09) (0.29) (72.52)
*Minimum differential increases with setpoint, values with neoprene diaphragm (Graphs available on request)
* Differentials of miroswitches A2 through A9 will vary. Differentials for A7 are typically twice that for A1 microswitch.
Please indicate specifically the differential value in enquiry/order, when it is critical in your application.
Group 1
Non standard
Group 2
Model
Group 3
Cable Entry Size
Group 4
Switch Type
Group 5
Range Code
Group 6
Microswitch
Group 7
Pressure Port
Group 8
Diaphragm
MT
allocation (values in bar) Type Material / Size
4
PA3 = ratings
H07 =
pressure switch, A7 = 2SPDT
(0.5 - 7.0)
adjustable switching elements
differential with H10 =
scale in psi (0.5 - 10.0) A9 = General
purpose microswitch
H15 = rated at 5 A; 250
(1.0 - 15.0) VAC
H30 =
(5.0 - 25.0)
eg. Industrial switch with ½" NPT cable entry in aluminium housing as 1SPDT pressure switch, fix differential with scale having 0.1 bar to 1 bar pressure
range, with 15 Amp. microswitch, SS316 pressure housing with ¼” BSP port size & neoprene diaphragm shall be specified by
Group 1 Group 2 Group 3 Group 4 Group 5 Group 6 Group 7 Group 8
MT 1 PF2 H01 A1 S1 0
Please specify full model number to avoid ambiguity.
5
7
MD HIGH RANGE DP
Locking screws
for drift proof Separate
settings terminal block
for wiring
Incast pin
Bell crank as a robust
lever for fulcrum
movement
transmission
1
Bulletin No. KA121024
5
7 144
HIGH RANGE DP MD
No. Description
1. Pressure Housing
2. Diaphragm
3. Plunger
3 1 4. O-Ring
5. Disc
2 4
INSTALLATION DRAWING
147.0
(5.78)
130.0
SET SCREW CAP (5.11)
112.5 62
(4.43) (2.44)
(0.78)
20
(2.79)
71
MOUNTING HOLES
(6.33)
2 Nos. Ø6.5
161
0.25
CABLE ENTRY
PRESSURE PORT
LOW PRESSURE PORT 1/4" BSP (F)
HIGH PRESSURE PORT
37
(1.45) 30
mm
(1.18) APPROX. DIMENSIONS IN
inches
* Note :
Microswitches A2 through A9 can be supplied in some ranges and differentials will vary with microswitch used.
Please contact sales office for details. Please check availability of adjustable differential with sales office.
147
adjustable differential D15 = *A4 = DPDT
without scale (1.0 - 15.0) configuration
*DA2 = pressure D30 = *A5 = for high
difference switch, (5.0 - 25.0) DC ratings
adjustable differential
*A7 = 2SPDT
with scale in bar
switching
*DA3 = pressure elements
difference switch, For additional
adjustable differential Please refer page no. 230
wetted parts
with scale in psi for more microswitch please refer
*Available with A9 options
Please refer page no.
Pressure Capsule
(in group 6) only * Please refer note under 226 & 227 for more Details on
Range Selection Table pressure port options Page 145
eg. A high range pressure difference weatherproof switch, with ½" NPT cable entry in aluminium housing as 1SPDT pressure switch, fixed differential without scale, having 0.1 bar to 1 bar
pressure range, with 15 Amp. microswitch, SS316 pressure housing with ¼” BSP port size & neoprene diaphragm shall be specified by
HIGH RANGE DP
IP66 enclosure
for excellent
ingress protection
Sealing facility
Cable gland as a to avoid
standard accessory tampering of
working switch
Non corroding
exteriors for a
long life
of the switch
Brass bulb
for sensing
temperature
INSTALLATION DRAWING
95.0
3.74
115.0 85.0
4.53 3.35
Cover Locking
Screw
4 Nos.
125.0
4.92
40.0
1.58
5.5
Cable Entry
(0.37)
50.0
1/2" NPT(M)
1.97
Options Available 51.0
S.S. Capillary Tube 2.0 Mtr. Lg. 100.0 2.01
3.94
mm
APPROX. DIMENSIONS IN
inches
70 - 150 20 200
T2H (158 - 302) (68) (392)
225
connection
E.g. A Process Temperature switch, with M20x1.5 cable entry as 1 SPDT, fixed differential with scale, having 25°C to 90°C temperature range, with
15 Amp. microswitch, with Brass 9.5 mm diameter bulb, having length 123 mm with 3/8”BSP(M),with 2.0 meter SS316 capillary length shall be
specified by
TEMPERATURE SWITCHES
Large spring
for ease of
Separate setpoint
terminal block
for wiring
IP66 enclosure
for excellent
ingress protection
Sealing facility
to avoid
tampering of
working switch
Cable gland as a
standard accessory
No. Description
6 1. Pressure Housing (SS316)
5 2. Diaphragm (Teflon®)
4 3. Plunger
3 4. Steel Ring (SS316)
2 5. O-Ring (Teflon®)
6. Disc
1
Note : wetted parts are mentioned in italics.
INSTALLATION DRAWING 93
(3.66)
114
85
(4.48)
(3.34)
4 Nos.
83
(4.88)
124
(0.98)
5.5
25
Mounting Bracket 41
(1.61)
Pressure Port 50
50
1/4" BSPF Std. (1.97)
(1.97) mm
(Options Avail.) APPROX. DIMENSIONS IN
inches
Range Code Range bar (psi) Differential* bar (psi) Maximum Working
Approximate Pressure bar (psi)
Maximum
for "A8"
microswitch
0.067 - 0.213 0.05 5
LP† (0.97 - 3.09) (0.72) (72.52)
*Minimum differential increases with setpoint (Graphs available on request), results for neoprene diaphragm.
†Range not available in SS316 L diaphragm.
189
H07 =
pressure switch,
(0.5 - 7.0)
adjustable
differential with H10 =
scale in psi (0.5 - 10.0)
*Available only with H15 =
option A9 in Group 6
(1.0 - 15.0)
H30 =
(5.0 - 25.0)
eg. A process pressure switch with fixed differential having 0.1 bar to 1 bar pressure range, with 5 Amp. microswitch, SS316 pressure housing with ¼” BSP
port size & neoprene diaphragm shall be specified by
HIGH RANGE PRESSURE SWITCHES
Robust
microswitch
Unique scale for reliable
enhancement switching
mechanism for
fine setting Bearing
resolution surface of
lever for
smooth motion
Bell crank
lever for Incast pin
movement as a robust
transmission fulcrum
External
mounting holes
for easy
mounting/
dismantling
Choice of
conduit entries
for various
cable sizes
5
4 No. Description
1. Pressure Housing
3
2. Plunger
2 3. Diaphragm (Teflon®)
1 4. Steel Ring (SS316 as per pr. hsg. material)
5. O-Ring (Teflon®)
Note : wetted parts are mentioned in italics.
INSTALLATION DRAWING
147
(5.78)
Set Screw Cap 112.5 62
(4.43) (2.44)
(3.07)
78
(4.18)
106.2
(0.78)
20
(2.79)
71
(4.48)
114
Mounting Holes
2nos, Ø6.5
(0.25)
Cable Entry
Pressure Port
30
37 1/4" BSP(F)
(1.18)
(1.45)
mm
APPROX. DIMENSIONS IN
inches
Range Code Range bar (psi) Differential* bar (psi) Maximum Working
Approximate Pressure bar (psi)
Maximum
for "A1"
microswitch
0.067 - 0.213 0.04 70
PP (0.97 - 3.09) (0.58) (1015.27)
*Minimum differential increases with setpoint, values with neoprene diaphragm (Graphs available on request)
* Note :
Microswitches A2 through A9 can be supplied in some ranges and differentials will vary with microswitch used.
Please contact sales office for details. Please check availability of adjustable differential with sales office.
103
differential without P07 =
scale (0.5 - 7.0) *A7 = 2SPDT
switching elements
*PA2 = pressure P10 =
switch, adjustable (0.5 - 10.0) *A9 = General
differential with scale purpose microswitch
P15 = rated at 5 A; 250
in bar
(1.0 - 15.0) VAC
*PA3 = pressure
switch, adjustable P30 =
differential with scale (5.0 - 25.0)
Please refer page no. 230
in psi for more microswitch
*Available with A9 options
Please refer page no.
(in group 6) only * Please refer note under 226 & 227 for more
Range Selection Table pressure port options
eg. A high proof high range weatherproof switch with ½" NPT cable entry in aluminium housing as 1SPDT pressure switch, fixed differential without scale, having 0.1 bar to 1 bar pressure
HIGH PROOF HIGH RANGE PRESSURE SWITCHES
range, with 15 Amp. microswitch, SS316 pressure housing with ¼” BSP port size & neoprene diaphragm shall be specified by
Group 1 Group 2 Group 3 Group 4 Group 5 Group 6 Group 7 Group 8
MD 1 PF1 P01 A1 S1 0
Please specify full model number to avoid ambiguity.
MT Low Range
Pressure Switches
CATALOGUE
No. Description
11 1. Pressure port (S.S.)
9 2. Support spring (S.S.)
10
3. Bottom flange (S.S.)
8 4. Support plate (Aluminium)
5. Diaphragm (Neoprene)
7
6. Gasket (Teflon)
7. Top plate (Aluminium)
8. Top flange (S.S.)
6
9. Plunger
10. Top flange screw (S.S.)
5
2 11. Sealing 'O' ring (Nitrile)
4
3
1
Note : wetted parts are mentioned in italics. *Presure ports are brazed with flange
(2.0)
51
(2.0)
(1.22)
51
(1.22)
31
31
(4.64)
118
65 1/4" BSP(M)
(2.55) Mounting Nut
Ø130
(5.11)
Pressure port
mm
1/4" BSP(F) APPROX. DIMENSIONS IN
inches
5.0 - 25.0 5 2
L03 (2.007 - 10.037) (2.007) (29.00)
10.0 - 50.0 5 2
L05 (4.015 - 20.073) (2.007) (29.00)
10.0 - 100.0 10 2
L10 (4.015 - 40.146) (4.015) (29.00)
10.0 - 150.0 10 2
L15 (4.015 - 60.22) (4.015) (29.00)
20.0 - 250.0 15 2
L25 (8.029 - 100.36) (6.021) (29.00)
50.0 - 350.0 25 2
L35 (20.073 - 140.52) (10.036) (29.00)
*Minimum differential increases with setpoint, values with neoprene diaphragm (Graphs available on request)
* Differentials of miroswitches A2 through A9 will vary. Differentials for A7 are typically twice that for A1 microswitch.
Please indicate specifically the differential value in enquiry/order, when it is critical in your application.
Group 1
Non standard
Group 2
Model
Group 3
Cable Entry Size
Group 4
Switch Type
Group 5
Range Code
Group 6
Microswitch
Group 7
Pressure Port
Group 8
Diaphragm
MT
allocation (values in mbar) Type Material / Size
4
switch, adjustable
L35 = ratings
differential without
scale (50 - 350) *A7 = 2SPDT
*PA2 = pressure switching elements
switch, adjustable *A9 = General
LOW RANGE PRESSURE SWITCHES
eg. A low range weatherproof switch, with ½" NPT cable entry in aluminium housing as 1SPDT pressure switch, fixed differential without scale, having 5
mbar to 25 mbar pressure range, with 15 Amp. microswitch, SS316 pressure housing with ¼” BSP port size & neoprene diaphragm shall be specified by
Group 1 Group 2 Group 3 Group 4 Group 5 Group 6 Group 7 Group 8
MT 1 PF1 L03 A1 S1 0
Please specify full model number to avoid ambiguity.
5
7