UNIVERSAL CABLES LTD.SATNA(M.

P)
PML3-SMO-002368-A TECHNICAL PARTICULARS Annexure-8.1
TECHNICAL PARTICULAR OF DC CABLE
Unit of
SN Description Measureme 1C x 400 Sqmm x 3.3 kV 1C x 400 Sqmm x 1.1 kV
nt
1 Name of the manufacturer Universal Cables Ltd. Satna (M.P.) Universal Cables Ltd. Satna (M.P.)
2 Country of manufacture India India
3 Relevant Specification Generally to IEC-60502-1 IEC-60502-1
4 Manufacturer’s type designation Cu/ XLPE/FRLS Cu/ XLPE/FRLS
5 Size of cable (Nom.) mm2 1C x 400 1C x 400
6 Rated system voltage 750 V DC (Positive) (Voltage grade - 750 V DC (Negative) (Voltage grade -
V DC
1.8/3 kV also suitable for 1.9/3.3 kV ) 0.6 /1 kV also suitable for 1.1 kV )
7 Rated continuous current A 857 Amps at 40 deg.C in Air 857 Amps at 40 deg.C in Air
8 Max permissible current :-

a At 90 °C (Continuous Rating) A 857 Amps at 40 deg.C in Air 857 Amps at 40 deg.C in Air
b At 120 °C (Emergency rating) 1080 Amps (at 40 deg.C in Air & max. 1080 Amps (at 40 deg.C in Air & max.
conductor temp. of 130 deg.C during conductor temp. of 130 deg.C during
emergency) emergency)
c At 250 °C (Short circuit rating) 57.2 kA for 1 sec (short circuit current of 57.2 kA for 1 sec (short circuit current of
conductor) conductor)
9 Permissible current of overload current in case
Hours Please refer S.No.8 (b) Please refer S.No.8 (b)
of emergency overload
10 Short circuit rating for one second 57.2 kA for 1 sec (short circuit current of 57.2 kA for 1 sec (short circuit current of
kA
conductor) conductor)
11 Permissible interval of successive emergency Not more than 100 Hrs. in any 12 Not more than 100 Hrs. in any 12
overloads at 130 °C Min consecutive months and not more than consecutive months and not more than
500 Hrs. during the life time of cable. 500 Hrs. during the life time of cable.
12 Group rating factor Please refer enclosed chart Please refer enclosed chart
13 Minimum permissible bending radius
m 15 x OD 15 x OD
14 Overall diameter of cable mm 35.0 (Approx.) 35.0 (Approx.)
15 Weight
a Weight per meter (Approx.) kg
b Gross weight of drum including cable kg
16 Jointing
a Type of jointing recommended Not in our scope Not in our scope
b Name of manufacturer of jointing kit’ Not in our scope Not in our scope
c Permissible temp rise of joint, if any Not in our scope Not in our scope
d Brief process of jointing Not in our scope Not in our scope
17 Termination (Indoor / outdoor)
Not in our scope Not in our scope

a Type of termination recommended


Not in our scope Not in our scope

b Name of manufacturer of termination Not in our scope Not in our scope


18 Overall dimension of the covering / box of joints

a Length mm Not in our scope Not in our scope


b Width mm Not in our scope Not in our scope
c Height mm Not in our scope Not in our scope
19 No. of voids per cubic inch of insulations Not in our scope Not in our scope
a Voids between 2 and 3 mils Nos. No such voids No such voids
b Voids larger than 3 mils Nos. No such voids No such voids
20 No. of contaminations per cubic inch of
insulation
a Contaminations between 2 & 7 mils No such contaminats No such contaminats
b Contamination larger than 7 mils No such contaminats No such contaminats
21 Physical data (Material used, dimensions in mm/
nos. and source of raw material to be indicated)

a XLPE insulation
XLPE to IEC-60502-1 (Nom. Thickness = XLPE to IEC-60502-1 (Nom. Thickness =
2.0 mm) 2.0 mm)

b Inner sheath (nominal and max thickness)


N/A N/A
c Armour (nominal & minimum)
N/A N/A

1b. GTP Siemens (Pune Metro) Rev1( 220208 DC Cable)/SS 1 of 2


UNIVERSAL CABLES LTD.SATNA(M.P)
PML3-SMO-002368-A TECHNICAL PARTICULARS Annexure-8.1
TECHNICAL PARTICULAR OF DC CABLE
d Outer sheath (nominal and minimum)
FRLS PVC type ST-2 as per IEC-60502- FRLS PVC type ST-2 as per IEC-60502-
1 (Red colour) (Min. thickness= 1.32 1 (Black colour) (Min. thickness= 1.32
mm) (With UV resistant & anti rodent & mm) (With UV resistant & anti rodent &
anti termite)) anti termite))

e Conductor screening
Not Applicable Not Applicable
f Insulation screening
Not Applicable Not Applicable
g Conductor Flexible circular, Plain Copper (Class- Flexible circular, Plain Copper (Class-
5) to IEC-60228 5) to IEC-60228
h Filler Not Applicable Not Applicable
i Copper tape Not Applicable Not Applicable
j Core identification tape Not Applicable Not Applicable
22 Brief process of manufacture indicating the
Dry cured Dry cured
method of cross-linking and type of curing
Additional data
A FRLS Tests on outer sheath
a. Oxygen Index test on FRLS sheath shall be
conducted as per ASTM : D2863 and minimum
We confirm We confirm
oxygen index shall be 29 at room temp .

b. Temperature Index test on FRLS sheath shall be


conducted as per ASTM : D2863 (by
extrapolation method) and minimum temperature We confirm We confirm
index shall be 250 ºC at oxygen index of 21% .

c. Acid Gas Generation test on FRLS sheath shall


be conducted as per IEC : 60754 (I) and max. We confirm We confirm
acid gas generation shall be 20 % by weight .
d. Smoke Generation test on FRLS sheath shall be
conducted as per ASTM : D-2843 and max. We confirm We confirm
smoke density rating shall be 60 %.
e. Flammability test on cable as per IEC-60332-1 IEC-60332-1
B Following details shall be provided by
a) Designation of ownership
Confirmed Confirmed
b) Nature and nom. cross sectional area of Confirmed Confirmed
c) Specified Cable Voltage (i.e 0.6/ 1 (1.2) kV or
Confirmed Confirmed
1.8/ 3 (3.6) kV)
d) Phase numbering by marking on outer sheath
Not Applicable Not Applicable
as 1, 2 & 3 in equal lengths
e) Manufacturer's name & trade name Confirmed Confirmed
f) Year of manufacture Confirmed Confirmed
C Length of cable shall be marked at every 1 m
Confirmed Confirmed
interval by printing.
23 Drum length in Wooden drum 500 mtrs +/-5% tol. 500 mtrs +/-5% tol.
Note :
1 The cables are offered as per IEC 60502-1 and hence all requirements & tests shall be as per IEC-60502-1.
2 FRLSH properties shall be as per S.No. B of Above GTP.

1b. GTP Siemens (Pune Metro) Rev1( 220208 DC Cable)/SS 2 of 2


PML3-SMO-002368-A Annexure-8.1
Universal Cables Limited,
P.O. Birla Vikas, Satna-485005 (M.P.), India
Supply Record for Metro Railways

Sl No Project Purchaser PO Reference Voltage Items Quanity (km)


(kV)
1 Kolkata Metro Perfecto Electricals, PE/17-3/2005-06/986 dt 1.1 CU / LSZH
Kolkata 06.07.05 3C x 2.5 mm2 1.208
5C x 2.5 mm2 0.566
8C x 2.5 mm2 0.520
12C x 2.5 mm2 0.659
15C x 2.5 mm2 1.563
44C x 2.5 mm2 0.491
2 Kolkata Metro Perfecto Electricals, PE/17-3/2005-06/932 dt 1.1 CU / LSZH
Kolkata 08.06.05 3C x 6 mm2 1.966
3C x 16 mm2 0.840
3C x 25 mm2 0.792
3.5C x 120 mm2 0.598
3.5C x 25 mm2 0.350
Universal Cables Ltd.
3 Delhi Metro 53003490 dtd 16.04.2010 66 1C x 1200 mm2- AL/AL 1.000
(Direct Order)
4 Kolkata Metro Perfecto Electricals, PE/14-3/2011-12/312dt
1.1 1C x 2.5 mm2- Cu / LSZH 11.000
Kolkata 04.07.11
5 Chennai Metro Siemens Ltd., New Delhi 4842 dtd 19.10.12
110 1C x 630 mm2 - AL / FRLS 1.875
6 Chennai Metro Siemens Ltd., New Delhi 4504174844 dt 19.10.12 Cu/FRLS
33 1C x 185 mm2 110.740
1.1 1C x 240 mm2 14.314
33 1C x 400 mm2 14.301
25 1C x 240 mm2 10.660
Cu / FRLSOH
25 1C x 240 mm2 8.875
33 1C x 185 mm2 101.004
7 Hyderabad Metro L&T Ltd., Chennai E5267PO2000052 dt
132 1C x 630 mm2 - AL / FRLS 15.000
19.12.12
8 Hyderabad Metro L&T Ltd., Chennai E5267PO2000053 dt AL / FRLS
20.12.12 33 1C x 300 mm2 26.000
33 1C x 400 mm2 2.000
33 1C x 630 mm2 26.000
33 1C x 300 mm2 365.000
33 1C x 400 mm2 92.000
33 1C x 630 mm2 6.000
25 1C x 630 mm2 1.000
25 1C x 400 mm2- Cu / FRLS 1.000
9 Delhi Metro Ircon International, New Ircon/5020/DMRC.ELECT.C 220 1C x 800 mm2 - AL/AL 5.100
Delhi E06/LOT1/EHV CABLE/4
dtd 09.5.13 66 1C x 800 mm2- AL/AL 183.150
10 Delhi Metro Siemens Ltd., Delhi 4504699213 dtd.23.08.13 33 1C x 400 mm2- Cu / FRLSOH 21.000
33 1C x 95 mm2- Cu / FRLSOH 1.500
25 1C x 240 mm2- Cu / FRLSOH 10.000
3.3 1C x 240 mm2- Cu / FRLSOH 2.500
11 Delhi Metro L&T Ltd., Chennai EA318PO3000007 dtd Cu / FRLS
30.12.2013 33 1C x 400 mm2 22.410
33 1C x 95 mm2 0.240
12 Delhi Metro L&T Ltd., Chennai EA318PO3000008 dtd Cu / FRLS
30.12.2013 33 1C x 400 mm2 91.500
33 1C x 300 mm2 45.000
33 1C x 95 mm2 10.050
13 Delhi Metro L&T Ltd., Chennai EA318PO3000009 dtd Cu / FRLS
30.12.2013 33 1C x 400 mm2 88.350
33 1C x 300 mm2 84.000
33 1C x 95 mm2 13.380
14 Delhi Metro L&T Ltd., Chennai E9568PO3000001 dtd Cu / FRLSOH
21.12.2013 33 1C x 400 mm2 158.400
33 1C x 95 mm2 15.000
33 1C x 400 mm2 -Cu / FRLS 25.500
15 Delhi Metro Siemens Ltd., Delhi LOI dt. 19.3.2014 66 1C x 800 mm2 -Al 145.000
3.3 1C x 240 mm2 Cu/FRLS 2.500
33 1C x 150 mm2 -Al/FRLS 0.750
3.3 1C x 240 mm2 -Cu/FRLS 51.100
3.3 1C x 240 mm2 -Cu / FRLSOH 19.000
PML3-SMO-002368-A Annexure-8.1
Universal Cables Limited,
P.O. Birla Vikas, Satna-485005 (M.P.), India
Supply Record for Metro Railways

Sl No Project Purchaser PO Reference Voltage Items Quanity (km)


(kV)
Universal Cables Ltd.
16 Delhi Metro 52008807 dt. 17.4.2014 66 1C x 1200 mm2- AL/AL 1.000
(Direct Order)
17 Delhi Metro L&T Ltd., Chennai E9717PO4000015 25 1C x 240 mm2 -Cu/FRLS 8.000
dt.03.05.14 3.3 1C x 240 mm2 -Cu/FRLS 8.000
18 Delhi Metro L&T Ltd., Chennai E9717PO4000016 25 1C x 240 mm2 -Cu/FRLS 9.500
dt.03.05.14 3.3 1C x 240 mm2 -Cu/FRLS 10.000
19 Bangalore Metro L&T Ltd., Chennai LOA No HQ:PI:BMRCL- 1.1 300x4 Cu / XLPE / LSZH 33.300
PKG:KSP: 053 dtd 28.04.14 240x4 Cu / XLPE / LSZH 9.570
185x4 Cu / XLPE / LSZH 2.910
70x4 Cu / XLPE / LSZH 2.730
50x4 Cu / XLPE / LSZH 0.060
35x4 Cu / XLPE / LSZH 0.630
35x3 Cu / XLPE / LSZH 1.350
25x4 Cu / XLPE / LSZH 2.110
25x3 Cu / XLPE / LSZH 4.620
16x4 Cu / XLPE / LSZH 56.340
16x4 Cu / XLPE / LSZH 2.520
10x4 Cu / XLPE / LSZH 0.400
10x4 Cu / XLPE / LSZH 1.465
6x4 Cu / XLPE / LSZH 0.980
6x3 Cu / XLPE / LSZH 2.640
4x4 Cu / XLPE / LSZH 0.550
4x3 Cu / XLPE / LSZH 0.100
4x2 Cu / XLPE / LSZH 0.600
2.5x4 Cu / XLPE / LSZH 0.300
2.5x3 Cu / XLPE / LSZH 0.300
2.5x4 Cu / XLPE / LSZH 0.300
2.5x5 Cu / XLPE / LSZH 0.300
2.5x7 Cu / XLPE / LSZH 0.300
2.5x9 Cu / XLPE / LSZH 0.300
2.5x12 Cu / XLPE / LSZH 0.300
2.5x16 Cu / XLPE / LSZH 0.300
2.5x19 Cu / XLPE / LSZH 0.300
300x4 Cu / XLPE / LSZH 6.450
185x4 Cu / XLPE / LSZH 0.820
70x4 Cu / XLPE / LSZH 2.150
95x3 Cu / XLPE / LSZH 0.505
16x4 Cu / XLPE / LSZH 0.045
16x3 Cu / XLPE / LSZH 0.285
10x4 Cu / XLPE / LSZH 2.810
6x4 Cu / XLPE / LSZH 0.065
4x2 Cu / XLPE / LSZH 0.300
2.5x2 Cu / XLPE / LSZH 3.635
1.5x2 Cu / XLPE / LSZH 3.500
2.5x2 Cu / XLPE / LSZH 1.400
2.5x2 Cu / XLPE / LSZH 9.000
2.5x3 Cu / XLPE / LSZH 3.000
2.5x4 Cu / XLPE / LSZH 12.990
2.5x5 Cu / XLPE / LSZH 9.000
2.5x7 Cu / XLPE / LSZH 7.200
2.5x9 Cu / XLPE / LSZH 1.500
2.5x12 Cu / XLPE / LSZH 1.200
2.5x16 Cu / XLPE / LSZH 0.600
2.5x19 Cu / XLPE / LSZH 1.800
6x1 Cu / XLPE / LSZH 0.300
10x1 Cu / XLPE / LSZH 0.300
16x1 Cu / XLPE / LSZH 0.300
70x1 Cu / XLPE / LSZH 0.600
150x1 Cu / XLPE / LSZH 0.300
PML3-SMO-002368-A Annexure-8.1
Universal Cables Limited,
P.O. Birla Vikas, Satna-485005 (M.P.), India
Supply Record for Metro Railways

Sl No Project Purchaser PO Reference Voltage Items Quanity (km)


(kV)
20 Delhi Metro L&T Ltd., Chennai LOA No 1.1 1.5x3 Cu / XLPE / LSZH 1.500
L&T/PT&D/IE/DMRC/SA/0 1.5x5 Cu / XLPE / LSZH 0.941
8 dt.04.09.14 1.5x10 Cu / XLPE / LSZH 3.139
1.5x14 Cu / XLPE / LSZH 1.661
2.5x3 Cu / XLPE / LSZH 1.055
2.5x5 Cu / XLPE / LSZH 2.220
2.5x10 Cu / XLPE / LSZH 2.220
2.5x14 Cu / XLPE / LSZH 2.220
2.5x19 Cu / XLPE / LSZH 4.440
2.5x27 Cu / XLPE / LSZH 4.440
4x2 Cu / XLPE / FRLS 1.140
2.5x2 Cu / XLPE / FRLS 1.000
10x2 Cu / XLPE / FRLS 0.554
2.5x3 Cu / XLPE / FRLS 1.000
2.5x4 Cu / XLPE / FRLS 1.310
25x4 Cu / XLPE / FRLS 1.390
0.75x2P Cu / XLPE / FRLS 0.475
2.5x3 Cu / XLPE / LSZH 0.098
1.5x19 Cu / XLPE / LSZH 0.510
1.5x3 Cu / XLPE / LSZH 1.095
1.5x5 Cu / XLPE / LSZH 2.550
1.5x10 Cu / XLPE / LSZH 6.226
1.5x14 Cu / XLPE / LSZH 3.373
2.5x3 Cu / XLPE / LSZH 0.745
2.5x5 Cu / XLPE / LSZH 3.875
2.5x10 Cu / XLPE / LSZH 2.510
2.5x14 Cu / XLPE / LSZH 3.835
2.5x19 Cu / XLPE / LSZH 8.600
2.5x27 Cu / XLPE / LSZH 8.160
4x2 Cu / XLPE / FRLS 2.280
2.5x2 Cu / XLPE / FRLS 1.000
10x2 Cu / XLPE / FRLS 1.610
2.5x3 Cu / XLPE / FRLS 2.180
2.5x4 Cu / XLPE / FRLS 0.980
25x4 Cu / XLPE / FRLS 1.020
0.75x2P Cu / XLPE / FRLS 0.325
2.5x3 Cu / XLPE / LSZH 2.970
1.5x5 Cu / XLPE / LSZH 2.120
1.5x10 Cu / XLPE / LSZH 0.700
1.5x14 Cu / XLPE / LSZH 4.490
1.5x19 Cu / XLPE / LSZH 4.010
1.5x27 Cu / XLPE / LSZH 0.700
1.5x4 Cu / XLPE / LSZH 2.310
4x2 Cu / XLPE / LSZH 4.670
2.5x2 Cu / XLPE / LSZH 2.350
10x2 Cu / XLPE / LSZH 3.900
2.5x3 Cu / XLPE / LSZH 1.570
2.5x4 Cu / XLPE / LSZH 1.750
25x4 Cu / XLPE / LSZH 2.350
2.5x3 Cu / XLPE / LSZH 23.640
2.5x3 Cu / XLPE / LSZH 22.000
1.5x3 Cu / XLPE / LSZH 22.000
0.75x2P Cu / XLPE / LSZH 0.760
21 Bangalore Metro SPML Infra Ltd., LOI No.: SPML-14/14- 1.1 300x4 Cu / XLPE / LSZH 7.175
Gurgaon 15/BMRCL/B063/008 240x4 Cu / XLPE / LSZH 3.450
dated 23.09.2014 185x4 Cu / XLPE / LSZH 1.370
95x4 Cu / XLPE / LSZH 0.100
95x3 Cu / XLPE / LSZH 0.140
70x4 Cu / XLPE / LSZH 0.975
25x4 Cu / XLPE / LSZH 1.685
16x4 Cu / XLPE / LSZH 22.420
16x3 Cu / XLPE / LSZH 1.650
6x3 Cu / XLPE / LSZH 5.267
4x4Cu / XLPE / LSZH 0.350
4x2 Cu / XLPE / LSZH 0.100
PML3-SMO-002368-A Annexure-8.1
Universal Cables Limited,
P.O. Birla Vikas, Satna-485005 (M.P.), India
Supply Record for Metro Railways

Sl No Project Purchaser PO Reference Voltage Items Quanity (km)


(kV)
300x4 Cu / XLPE / LSZH 2.200
185x4 Cu / XLPE / LSZH 0.200
95x4 Cu / XLPE / LSZH 0.100
70x4 Cu / XLPE / LSZH 0.600
10x4 Cu / XLPE / LSZH 1.525
6x3 Cu / XLPE / LSZH 0.070
4x2 Cu / XLPE / LSZH 0.100
2.5x2 Cu / XLPE / LSZH 1.760
2.5x4 Cu / XLPE / LSZH 0.080
2.5x3 Cu / XLPE / LSZH 0.080
2.5x4 Cu / XLPE / LSZH 0.080
2.5x5 Cu / XLPE / LSZH 0.080
2.5x7 Cu / XLPE / LSZH 0.080
2.5x9 Cu / XLPE / LSZH 0.080
2.5x12 Cu / XLPE / LSZH 0.080
2.5x16 Cu / XLPE / LSZH 0.080
2.5x19 Cu / XLPE / LSZH 0.080
2.5x2 Cu / XLPE / LSZH 2.400
2.5x3 Cu / XLPE / LSZH 0.800
2.5x4 Cu / XLPE / LSZH 3.464
2.5x5 Cu / XLPE / LSZH 1.502
2.5x7 Cu / XLPE / LSZH 1.920
2.5x9 Cu / XLPE / LSZH 0.400
2.5x12 Cu / XLPE / LSZH 0.320
2.5x16 Cu / XLPE / LSZH 0.160
2.5x19 Cu / XLPE / LSZH 0.480
6x1 Cu / XLPE / LSZH 0.100
10x1 Cu / XLPE / LSZH 0.100
16x1 Cu / XLPE / LSZH 0.100
70x1 Cu / XLPE / LSZH 0.150
150x1 Cu / XLPE / LSZH 0.050
2.5x1 Cu / XLPE / LSZH 205.860
4x1 Cu / XLPE / LSZH 5.000
2.5x1 Cu / XLPE / LSZH 67.410
4x3 Cu / XLPE / LSZH 3.280
6x3 Cu / XLPE / LSZH 4.640
6x4 Cu / XLPE / LSZH 0.640
4x4 Cu / XLPE / LSZH 1.250
4x2 Cu / XLPE / LSZH 0.250
4x3 Cu / XLPE / LSZH 8.250
22 Kochi Metro Alstom Transport LOI No.: Nil dt.06.04.15 33 240x1 Cu / XLPE / FRLS 165.000
India Ltd., Noida 33 95x1 Cu / XLPE / FRLS 10.640
1.1 185x1 Cu / XLPE / FRLS 55.000
1.1 300x1 Cu / XLPE / FRLS 48.700
1.1 300x1 Cu / XLPE / FRLS 7.735
1.1 400x1 Cu / XLPE / FRLS 4.200
1.1 400x1 Cu / XLPE / FRLS 3.100
1.1 1.5x19 Cu / XLPE / FRLS 0.500
1.1 1.5x12 Cu / XLPE / FRLS 2.282
1.1 2.5x7 Cu / XLPE / FRLS 0.250
1.1 2.5x3 Cu / XLPE / FRLS 1.038
1.1 4x3 Cu / XLPE / FRLS 51.264
1.1 25x1 Cu / XLPE / FRLS 0.123
1.1 10x2 Cu / XLPE / FRLS 0.239
1.1 4x5 Cu / XLPE / FRLS 1.509
1.1 1.5x10 Cu / XLPE / FRLS 0.650
1.1 2.5x12 Cu / XLPE / FRLS 0.550
1.1 2.5x4 Cu / XLPE / FRLS 2.200
1.1 4x2 Cu / XLPE / FRLS 2.000
1.1 4x2 Cu / XLPE / LSZH 29.000
1.1 4x2 Cu / XLPE / LSZH 29.000
1.1 25x5 Cu / XLPE / FRLS 51.000
33 240x1 Cu / XLPE / FRLS 1.271
33 150x1 Al / XLPE / FRLS 0.800
1.1 1.5x19 Cu / XLPE / FRLS 0.275
PML3-SMO-002368-A Annexure-8.1
Universal Cables Limited,
P.O. Birla Vikas, Satna-485005 (M.P.), India
Supply Record for Metro Railways

Sl No Project Purchaser PO Reference Voltage Items Quanity (km)


(kV)
1.1 1.5x12 Cu / XLPE / FRLS 1.255
1.1 2.5x7 Cu / XLPE / FRLS 0.138
1.1 2.5x3 Cu / XLPE / FRLS 0.571
1.1 4x3 Cu / XLPE / FRLS 0.145
1.1 25x1 Cu / XLPE / FRLS 0.068
1.1 10x2 Cu / XLPE / FRLS 0.131
1.1 4x5 Cu / XLPE / FRLS 0.830
1.1 1.5x10 Cu / XLPE / FRLS 0.358
1.1 2.5x12 Cu / XLPE / FRLS 0.303
1.1 2.5x4 Cu / XLPE / FRLS 1.210
1.1 4x2 Cu / XLPE / FRLS 1.100
23 Kochi Metro Alstom Transport LOI No.: Nil dt.06.04.15 110 1C x 630 mm2 - AL / Al.Sheath/ 31.898
India Ltd., Noida HDPE
24 Bangalore Metro L&T Ltd., E9402P05000060 1.1 300x4 Cu / XLPE / LSZH 10.781
Chennai Dt.08.04.15 35x4 Cu / XLPE / LSZH 1.643
25x4 Cu / XLPE / LSZH 33.811
25x3 Cu / XLPE / LSZH 4.737
10x4 Cu / XLPE / LSZH 0.061
6x3 Cu / XLPE / LSZH 7.293
4x4 Cu / XLPE / LSZH 0.504
2.5x3 Cu / XLPE / LSZH 0.103
2.5x19 Cu / XLPE / LSZH 0.107
300x4 Cu / XLPE / LSZH 17.509
185x4 Cu / XLPE / LSZH 0.573
70x4 Cu / XLPE / LSZH 3.391
95x3 Cu / XLPE / LSZH 0.124
10x4 Cu / XLPE / LSZH 1.949
6x3 Cu / XLPE / LSZH 0.329
2.5x9 Cu / XLPE / LSZH 0.511
2.5x12 Cu / XLPE / LSZH 4.850
2.5x16 Cu / XLPE / LSZH 12.444
6x1 Cu / XLPE / LSZH 7.785
70x1 Cu / XLPE / LSZH 1.580
150x1 Cu / XLPE / LSZH 43.755
25 Delhi Metro L&T Ltd., Chennai EA318PO5000064 dtd. 33 Cu /XLPE/FRLS 4.950
14.04.2015 1C x 400 mm2
26 Delhi Metro L&T Ltd., Faridabad E971PO5000071 dtd. 33 Cu /XLPE/FRLS 4.000
6.6.2015 1C x 240 mm2
27 Delhi Metro L&T Ltd., Faridabad E971PO5000070 dtd. 25 Cu /XLPE/FRLS 15.000
6.6.2015 1C x 240 mm2
28 Delhi Metro Isolux Ingenieria S.A. Spain IISA/DMRC-CE-6-LOT-3/PO- Cu /XLPE/FRLS
29 dt. 25.5.2015 25 1C x 240 mm2 1.932
33 1C x 400 mm2 1.985
33 1C x 150 mm2 0.450
3.3 1C x 240 mm2 1.617
29 Hyderabad Metro L&T Ltd., Chennai E5267PO5000052 dtd. 33 Al /XLPE/FRLS
16.6.2015 1C x 630 mm2 55.000
1C x 800 mm2 32.000
30 Bangalore Metro L&T Ltd., Chennai E9402PO5000175 dtd. 1.1 Cu /XLPE/LSZH
5.9.2015 3C x 4 mm2 2.351
3C x 6 mm2 30.000
4C x 6 mm2 1.000
Cu /XLPE/FS
3C x 4 mm2 35.000
31 Lucknow Metro L&T Ltd., Chennai LOA No. LTCD/HQ/ Al /XLPE/FRLS/CAS
SCM/LMRC/04 dtd. 220 1C x 800 mm2 63.600
8.1.2016 132 1C x 630 mm2 38.200
32 Kolkata Metro Siemens Ltd., Delhi 4506943490 dt.30.08.2016 CU/XLPE/FRLS/FRLSOH
33 1C x 240 mm2 19.250
33 1C x 240 mm2 (FRLSOH) 62.283
33 1C x 150 mm2 47.451
33 1C x 150 mm2 (FRLSOH) 42.139
3.3 1C x 400 mm2 25.820
1.0 1C x 400 mm2 6.125
3.3 1C x 400 mm2 (FRLSOH) 22.360
1.0 1C x 400 mm2 (FRLSOH) 4.815
1.1 1C x 120 mm2 1.425
PML3-SMO-002368-A Annexure-8.1
Universal Cables Limited,
P.O. Birla Vikas, Satna-485005 (M.P.), India
Supply Record for Metro Railways

Sl No Project Purchaser PO Reference Voltage Items Quanity (km)


(kV)
33 Mumbai Metro Tata Projects Ltd., SBU-RAILWAYS/Navi Al /XLPE/FRLS/CAS
Hyderabad Mumbai Metro/3491 220 1C x 500 mm2 1.270
dt.17.12.2016 220 1C x 1200 mm2 1.450
Bonding Cable
6.6 1C x 300 mm2 0.030
34 Mumbai Metro Tata Projects Ltd., BU-Transportation/Navi AL /XLPE/PVC
Hyderabad Mumbai Metro/3785 33 1C x 300 mm2 2.400
dt.23.03.2017 33 1C x 630 mm2 4.200
Cu /XLPE/FRLS
25 1C x 240 mm2 9.722
ISolux Ingenieria S.A. IISA/DMRC-CE-6-Lot 3/PO-
35 Delhi Metro 132 630 x 1C - Al/CAS 66.500
02 dt. 29.8.2017
Anant Electricals & AEE/PO/DMRC/18_R1
36 Delhi Metro 3.3 1C x 240 mm2- Cu/FRLS 5.500
Engineers dt.05.12.17
Alstom India Limited 4100000015700
37 Jaipur Metro CU/XLPE/FRLS
Gurgaon dt.13.06.18
33 1C x 95 mm2 0.560
33 1C x 400 mm2 14.217
25 1C x 240 mm2 1.600
Alstom India Limited 4100203663 dt.12.09.18
38 Jaipur Metro CU/XLPE/FRLS
Gurgaon
1.1 4C x 16 mm2 0.560
1.1 3C x 2.5 mm2 1.330
1.1 12C x 1.5 mm2 0.500
1.1 19C x 1.5 mm2 0.560
39 Chennai Metro Siemens Ltd., Delhi 4508603360 dt.27.09.18 25 1C x 240 mm2- Cu/FRLSOH 6.550
Kochi Metro Alstom India Limited 4100217768 dt.26.10.18
40 CU/XLPE/FRLS
Gurgaon
33 1C x 240 mm2 36.495
750V DC Positive Cable
3.3 1C x 300 mm2 11.000
3.3 1C x 400 mm2 0.676
750V DC Negative Cable
1.1 1C x 300 mm2 1.500
CU/XLPE/FRLS
1.1 1C x 185 mm2 12.000
1.1 5C x 25 mm2 14.000
1.1 19C x 1.5 mm2 1.200
41 Chennai Metro Siemens Ltd., Delhi LOI 33 1C x 185 mm2- Cu/FRLSOH 1.200
42 Jaipur Metro Alstom Transport India 4100222411 dtd 14.11.18 1.1kV FS Cable
3C x 2.5 sq.mm 4.600
7C x 2.5 sq.mm 4.600
43 Delhi Metro L&T Ltd., Chennai E9717PO000076 25 Cu/XLPE/FRLS
Dt.30.11.18 1C x 240 mm2 6.000

44 Dhaka Metro L&T Ltd., Chennai EI592PO8000002 132 Cu/CAS


Dt.03.12.18 1C x 300 mm2 34.020

45 Mauritius Metro L&T Ltd., Chennai EH151P09000129 1.1 Cu/FRLS


Dt.14.03.19 1C x 70 mm2 58.485

46 Chennai Metro Siemens Ltd., Gurgaon 4509024410 CU/XLPE/FRLS


Dt.15.04.19 33 1C x 185 mm2 42.000
25 1C x 240 mm2 20.000
CU/XLPE/FRLSOH
33 1C x 185 mm2 23.500
25 1C x 240 mm2 10.500
47 Bangalore Metro L&T Ltd., Chennai EJ372PO9000035 Cu /XLPE/CAS/Al.WA/PE
Dt.27.06.19 220 1C x 800 mm2 33.000
132 1C x 630 mm2 18.000

48 Bangalore Metro Alstom Transport India 4100298374 CU/XLPE/FRLS


(BMRCL) Ltd., Bangalore Dt.11.07.19 33 1C x 240 mm2 511.480
Modification dtd 05.08.19
49 Pune Metro Alstom Transport India Pvt 4100372017 dtd 24-02- 3.3 1C x 240 mm2- Cu / FRLSOH 10.910
Ltd, 2020 3.3 1C x 240 mm2- Cu / FRLS 4.100
25 1C x 240 mm2- Cu / FRLSOH 29.143
PML3-SMO-002368-A Annexure-8.1
Universal Cables Limited,
P.O. Birla Vikas, Satna-485005 (M.P.), India
Supply Record for Metro Railways

Sl No Project Purchaser PO Reference Voltage Items Quanity (km)


(kV)
25 1C x 240 mm2- Cu / FRLS 11.456
50 Delhi Metro Siemens Ltd, Gurgaon 4509592991 18/30kV 1C x 300 mm2 - Al/FRLSOH 22.660
(DMRC) CE-26 Dt.08.01.2020 26/45kV 1C x 240 mm2 -Cu/FRLSOH 2.250
Approved doc.on 28-04-20