BITZER Software v7.0.3 rev0          Thursday 10. October 2024 3:35:43 PM / All data subject to change.
1/1
Selection: Semi-hermetic Reciprocating Compressors
Input Values
Cooling capacity               15,00 kW
Mode                           Refrigeration and air
                               conditioning
Refrigerant                    R407C
Reference temperature          Dew point temp.
Evaporating SST                -10,00 °C
Condensing SDT                 20,00 °C
Liq. subc. (in condenser)      15,00 K
Suction gas temperature        10,00 °C
Operating mode                 Auto
Power supply                   400V-3-50Hz
Capacity control               100%
Useful superheat               100%
Result
Compressor                           4FES-3Y-40S                                   4EES-4Y-40S
Capacity steps                       100%                                          100%
Cooling capacity                     12,31 kW                                      15,49 kW
Cooling capacity *                   11,24 kW                                      14,14 kW
Evaporator capacity                  12,31 kW                                      15,49 kW
Power input                          2,43 kW                                       3,02 kW
Current (400V)                       5,17 A                                        5,63 A
Voltage range                        380-420V                                      380-420V
Condenser capacity                   14,74 kW                                      18,51 kW
COP/EER                              5,07                                          5,14
COP/EER *                            4,63                                          4,69
Mass flow                            199,2 kg/h                                    251 kg/h
Operating mode                       Standard                                      Standard
Discharge gas temp. w/o cooling      67,1 °C                                       66,5 °C
*According to EN12900 (20°C suction gas temp., 0K liquid subcooling) - attention: data based on dew point!
Application Limits 100% 4EES-4, 4FES-3
                                                                                     Legend
                                                                                            additional cooling & suction gas
                                                                                            superheat ≤20K
                                                                                            additional cooling
                                                                                            M1: motor 1