BITZER Software v7.0.3 rev0          Thursday 10. October 2024 3:39:52 PM / All data subject to change.
1/1
Selection: Semi-hermetic Reciprocating Compressors
Input Values
Cooling capacity               15,00 kW
Mode                           Refrigeration and air
                               conditioning
Refrigerant                    R407C
Reference temperature          Dew point temp.
Evaporating SST                -15,00 °C
Condensing SDT                 15,00 °C
Liq. subc. (in condenser)      0K
Suction gas temperature        10,00 °C
Operating mode                 Auto
Power supply                   400V-3-50Hz
Capacity control               100%
Useful superheat               100%
Result
Compressor                           4DES-5Y-40S                                   4CES-6Y-40S
Capacity steps                       100%                                          100%
Cooling capacity                     13,58 kW                                      17,15 kW
Cooling capacity *                   13,72 kW                                      17,33 kW
Evaporator capacity                  13,58 kW                                      17,15 kW
Power input                          2,99 kW                                       3,76 kW
Current (400V)                       6,34 A                                        8,09 A
Voltage range                        380-420V                                      380-420V
Condenser capacity                   16,57 kW                                      20,9 kW
COP/EER                              4,54                                          4,56
COP/EER *                            4,59                                          4,61
Mass flow                            233 kg/h                                      295 kg/h
Operating mode                       Standard                                      Standard
Discharge gas temp. w/o cooling      69,0 °C                                       68,8 °C
*According to EN12900 (20°C suction gas temp., 0K liquid subcooling) - attention: data based on dew point!
Application Limits 100% 4CES-6, 4DES-5
                                                                                     Legend
                                                                                            additional cooling & suction gas
                                                                                            superheat ≤20K
                                                                                            additional cooling
                                                                                            M1: motor 1