Solar Power Plant Equipment Guide
Solar Power Plant Equipment Guide
DATA SHEET
High Efficiency ↑ ↑
10-30% Additional Power Generation
23.03%
Excellent module conversion ↑ ↑
More than 10-30% additional power gain
efficiency of up to 23.03% comparing with the regular modules.
a
# Additional power gain from rear side compared to power of front side at STC
depends on mounting structure (height, tilt angle etc.) and reflectivity of ground.
Bi-Faciality Factor : 80 ± 5 %
Ø9*Ø14 mm
Mounting hole
PERMISSIBLE OPERATING CONDITIONS 8 Nos.
1095±1
1134±2
IV CURVE PV CURVE Back view Side view
Ø7*Ø10mm Ø9*Ø14mm 9
16 600
Incident Irrad. = 1000 W/m2 mounting hole mounting hole
Incident Irrad. = 1000 W/m2
14 Incident Irrad. = 800 W/m2
Incident Irrad. = 800 W/m
2
500 Incident Irrad. = 600 W/m
2
7
12
Incident Irrad. = 400 W/m2
30 30
Incident Irrad. = 200 W/m2
Current (A)
10 400
Incident Irrad. = 600 W/m
2
Cells temp. = 25°C 14
8 10
Power (W)
0
100
“Unspecified dimensions tolerance are according to ISO 2768-1, class m.”
0 10 20 30 40 50 60
Voltage(V) 0
0 10 20 30 40 50 60
Voltage(V) PRODUCT CERTIFICATIONS
IEC 61215: 2021, IEC 61730: 2016, IS 14286:2010/IEC 61215:2005,
LINEAR GRAPH IS/IEC 61730-1 & 2: 2004, IEC 61701, IEC 62716, IEC 60068-2-62,
Standard Module Linear Performance Warranty
99.0% Goldi N-type Bifacial Double Glass Module IEC CD 61215-2:2018, UL 61730-1 &2 , IEC 62804, CEC
97.0% Linear Performance Warranty
TDS-GS10T144GF-V 1.4
89.4% I
87.4 %
87.4% 1.00%
1st-year Degradation
Cable Description : 1c x 6 mm2 Annealed Tinned Flexible Copper Conductor, EBXL XLPO insulated & Sheathed Solar Cable
Part No 8301029004 ÖLFLEX® SOLAR XLS-E 1X6 Sq mm WH/BK
8301029020 ÖLFLEX® SOLAR XLS-E 1x6 Sq mm WH/BK-RD
Sr.N Properties Unit Specification (Based on EN50618 & IEC62930)
1 Cable size (nominal) Sq.mm 6
2 No.of Cores Nos. 1
3 Construction 1 x 6.0
4 I) Voltage Rating ( U。/ U ) -AC 1.0 / 1.0
kV 1.5 / 1.5
5 II) Voltage Rating - ( U。/ U ) -DC DC 1.8 kV max. (conductor/conductor, non earthed system)
5.1 Material Fine wire strands of annealed tinned copper
5.2 Max. conductor temperature °C 120
5.3 Type of Conductor According to IEC 60228, Class 5
5.4 No of Wire (Strands) Nos. 84
5.5 Strand Diameter mm 0.30 (+0.01/-0.02)
5.6 Max. DC Conductor Resistance at 20°C Ohm/km 3.39
6 INSULATION
6.1 Material Electron beam cross-linked polyolefin co-polymer (XLPO)
6.2 Nominal Thickness of Insulation mm 0.7
6.3 Insulation Resistance ( Min) MΩ.km 500 (20℃), 0.5 (90℃)
6.4 Insulation Colour White
6.5 min, thickness of insulation mm 0.53
7 Outer Sheath
7.1 Material Electron beam cross-linked polyolefin co-polymer
7.2 Nom.Thickness of Outer sheath mm 0.8
7.3 Nominal Overall Diameter of cable mm 6
7.4 min, thickness of outer sheath mm 0.58
7.5 Approx cable weight Kg/km 87.57
7.6 Copper Index Kg/km 57.6
U274 LAPP KABEL STUTTGART ÖLFLEX® SOLAR XLS-E 1/1 kV AC /
7.7 Marking on the Cable DC 1500V 1 x 6 SQMM HALOGEN FREE LOW SMOKE ELECTRIC
CABLE <TRACEABILITY> <METER MARKING>
8.1 Current Rating in Air at 60 °C Ambient Amps 70 A (Single cable free in air)
Temp.
8.2 Max.Continuous working Temp °C 120°C
8.3 Max.conductor temp at termination of °C 250°C(5s)
short circuit
8.4 Min, Bending Radius mm occasional flexing: 15 cable diameter fixed installation: 5 cable diameter
Originator: CS / PE
Approved: SNP / PE
850 ±3 300 ±3 769.5 ±3 300 ±3
Venting
4
Element Ø1 s.
4 No
IP-65
Converter
DC to DC
24V
DC Switch
+ve I/P Fuse 50A 3P/400A
4A
I/07
I/08
I/09
I/10
I/11
I/12
GND +5V RX2 TX2
700 ±3
723 ±3
TRICHECK MODULER 12 STRING +V E
6
M1
I/01
I/02
I/03
I/04
I/05
I/06
+ve -ve -ve I/P Direct on ST Card
+ve I/P Fuse 50A O/P O/P
O/P Busbar
50X5 GND +5V TX2 RX2 GND PT1 PT1 GND PT2 PT2 -+- +
- m A + IN P - ve + IN P INP-1 INP-0
With FM
1500V DC
TRIN RF Module
+24V -24V
ET
+- -
+
16
Sqmm SPD
SPD
T1+T2
T2
Spare
+ve I/P Fuse 50A
IP-65
Venting
MC-4 Type Male MC-4 Type Female Element
Panel Connectors Panel Connectors
Antenna
58.5
Antenna With
3 Meter Cable
Antenna Mounting
in Customer Scope
±3 for Hole
3. D:\DATA\Pics\Stickers\Trinity Touch.JPG
Position Dimension Article No. :-
BOM 10 in 1 0ut +1 Spare SMB (RF ) - 1500V Rated GA Dwg 8511
2 CONDUCTOR
Material Aluminium Conductor as per IS 8130
Shape H2 Aluminium Stranded Class 2
Cross Sectional Area sq.mm. 300 400
Approx No of strands Nos. 37 59
3 CONDUCTOR TEMPERATURE
Max. Rated 90 Deg .C.
During short circuit 250 Deg. C.
4 INSULATION
Material Extruded Cross linked polyethylene (XLPE) as per IS : 7098 Part 2
Thickness (Nominal) mm 2.5 2.6
Core Identification Black Black
5 INNER SHEATH
Material NA NA
Thickness (Min.) mm NA NA
6 ARMOUR
Material Galvanized Steel Flat Strip as per IS: 3975
Shape Flat Strip Flat Strip
Size mm 4.0 x 0.8 4.0 x 0.8
7 OUTER SHEATH
Extruded FR-LSH PVC Type ST-2 as per IS- 5831/1984 (with UV resistant, Anti
Material
Termite & Anti Rodent properties)
Thickness (Min.) mm 1.56 1.56
Colour Red for +ve & black for -ve
G ENVIRONMENT LIMIT
1 Ambient Temperature Range (Nominal Rating) -20 ...+50 DegC
2 Maximum Ambient Temperature (Operational) +60 DegC
3 Relative Humidity 4 ... 100%, Non Condensing
4 Nominal Altitude 1000 meter above Sea Level
5 Maximum Altitude (with power derating) 4000 meter above Sea Level
6 Maximum Noise Level *** < 84 dB(A) at one meter
** *At partial power, typically less than 75 dbA
H USER INTERFACE AND COMMUNICATIONS
1 Local User Interface ABB Control Panel ( LCD Display with Keypad)
2 Fieldbus connectivity +K475, Ethernet Adapter (Modbus TCp/IP, Profinet; 2 - port)
3 Emergency stop switch Yes
4 Display of Alarm and Fault Display is available
5 Display of AC and DC Parameter Display is available
5 Display of Energy Generation Display is available
I TERMINATION DETAILS
1 Cable Entry/Exit Bottom Entry
2 Gland Plate Undrilled
3 AC Termination Busbar Details 160mm X 20mm , Cu ; hole size : 14.5 mm(dia.)
4 DC Termination Busbar Details 40mm X 5mm, Tinned Aluminium; hole size : 13 mm(dia.)
5 Recommended AC Cable Termination Bus duct
6 Recommended DC Cable Termination Calculated based on DC inputs
Ground Fault Monitoring, Grid Monitoring, Anti-Islanding, LVRT, DC Reverse Polarity, Reactive Power Compensation, Over voltage Protection, Over
Current Protection, Insulation Monitoring, Over temperature Protection
Rev-No. Revision Description & Date Prepared by Hamsa N Yadav Doc No.
00 31 October 2023 Approved by Prasanna Kumar L F2376020-HAA
Customer Title Dept. Engg.
Ace Renewtech Engineering Private Limited INVERTER DATASHEET Sheet A4
Project Lang. English
SOLAR
Solar Power Plant-ACE-100MW-4MW Page 2 of 2
BUSDUCT ARRANGEMENT PLAN
FFL 1.5M
TOC +0.6m
NGL +0.0m
ELEVATION VIEW
CL
ES2N
1U
HV SIDE
LV SIDE
1V
1W
PLAN VIEW
8 7 6 5 4 3 2 1
32 1
support insulators
33 NITROGEN INJECTION VALVE FOR NIFPS ( 25MM GUNMETAL VALVE ) 4
34 NITROGEN DRAIN VALVE FOR NIFPS ( 50MM GUNMETAL VALVE ) 1 Note: All Dimensions are in mm with subject to tolerance 5%.
35 MOUNTING BRACKETS FOR NIFPS SENSORS AS REQ
PROJECT :
36 MOUNTING BRACKETS FOR SIGNELLING BOX 1 SET 4 MW ac ASJV POWER SOLAR PROJECT.
B B
37* RADIATOR LEG SUPPORTS 6 CUSTOMER :
38 UNDER BASE SKIDS ARRANGEMENT ( Reffer at ''ET-GA-A4-09'' ) - M/s. ACE RENEWTECH ENGINEERING PVT LTD.
39 EXPLOSION VENT WITH EQUALIZER PIPE 1
40 FOUNDATION / ANTI EARTH QUAKE CLAMPS 4 SCALE: 1:50
4400kVA, 33KV/690V, OFF CIRCUIT, 3 PHASE TRANSFORMER.
VER 0 TITLE:
Date 10-09-2024 FITTINGS LIST OF TRANSFORMER
NOTE:-* MARKED ITEMS WILL BE REMOVED AT THE TIME OF TRANSPORT. Drawn Ganesh
DRG NO: ET-GA-A4-01 Sheet 2 of 11
Checked Raju REV
A ALL DIMENSIONS ARE IN MM ESENNAR ESENNAR TRANSFORMERS (P) LTD. A
Approved PR UNIT-II, HYDERABAD. 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
F L=3635 F
CL
1569 2066
10
8
CL
31
19 CL
E E
H=3380
1811 50
Breather H= 1289
1746 50
1 9
D D
30 33 BASE LEVEL 36
970 30 767 30
2500 30 1257 30 970 30
2 40
29 14
FRONT VIEW(HV SIDE) SIDE VIEW 4 FRONT VIEW(LV SIDE)
LV SIDE NOTE:
1.Total Weight of Transformer is 11420 kg (Approx)
2U 2V 2W
C 2.Plinth Dimensions (Minimum) : Length X Width X Height C
( See in ET-GA-A4-08)
3.Overal Dimensions : Length X Width X Height
( L=3635 X W = 3507 X H=3380 )
910 30
=
Copy rights rests with ESENNAR TRANSFORMERS PVT LTD.
CUSTOMER :
M/s. ACE RENEWTECH ENGINEERING PVT LTD.
=
SCALE: 1:50
4400kVA, 33KV/690V, OFF CIRCUIT, 3 PHASE TRANSFORMER.
1U 1V 1W VER 0 TITLE:
Date 10-09-2024 GENERAL ASSEMBLY OF T/F
Drawn Ganesh
HV SIDE DRG NO: ET-GA-A4-02 Sheet 3 of 11
Checked Raju REV
A ALL DIMENSIONS ARE IN MM ESENNAR ESENNAR TRANSFORMERS (P) LTD. A
TOP VIEW Approved PR UNIT-II, HYDERABAD. 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
F F
220
210
3 9-6 34650
7 7 7 3.All Dimensions are in mm
8 8 8
4 6 - 10 33825
9
10
9
10
9
10
4.ESENNAR Logo should be in Red Colour.
11 11 11
5 10 - 5 33000
Copy rights rests with ESENNAR TRANSFORMERS PVT LTD.
690 12 12 12
6 5 - 11 32175
7 11 - 4 31350 ES
8 4 - 12 30525 2N 2U 2V 2W Note: All Dimensions are in mm with subject to tolerance 5%.
9 12 - 3 29700
S1
PROJECT :
S2
B 1U 4 MW ac ASJV POWER SOLAR PROJECT. B
11 WTI CT DETAILS CUSTOMER :
2U RATIO 3700 / 5A M/s. ACE RENEWTECH ENGINEERING PVT LTD.
2V
2W
1W 1V L.V SCALE: 1:2
MADE IN INDIA 4400kVA, 33KV/690V, OFF CIRCUIT, 3 PHASE TRANSFORMER.
VER 0 TITLE:
Date 10-09-2024 RATING AND DIAGRAM PLATE
Drawn Ganesh
DRG NO: ET-GA-A4-07 Sheet 8 of 11
Checked Raju REV
A ALL DIMENSIONS ARE IN MM ESENNAR ESENNAR TRANSFORMERS (P) LTD. A
Approved PR UNIT-II, HYDERABAD. 1
8 7 6 5 4 3 2 1
ESENNAR
TRANSFORMERS (P) LTD.-Unit-II
PAGE 1 OF 3
23.0 Impedance(Z)[Percentage] * SUBJECT TO IS TOLERANCE
HV - LV * 6.50%
24.0 * No Load Current(% of Rated Current) Less than 1.0%
25.0 EFFICIENCY
Efficiency at 75 Deg. C. U.P.F 0.8 P.F
100% full Load 99.10% 98.88%
75% full Load 99.27% 99.09%
50% full Load 99.42% 99.27%
Max. efficiency 99.46%
Load at which max. efficiency occurs KVA 1466.67
Economical to operate between KVA 1466.67 to 4400
RAL 7035
29.0 Painting [Finish]
PAGE 2 OF 3
III) STANDARD FITTINGS AND ACCESSORIES INCLUDED IN THE BASIC PRICE
S.No DESCRIPTION QTY(NO.S)
1) Rating and Terminal Marking Plate One
2) Earthing Terminals Two
3) Lifting Lugs Four
4) Drain Valve with Blanking Plate One
5) Filter Valve with Blanking Plate One
6) Conservator One
7) Conservator Oil Filling Hole With flange One
8) Oil Level Indicator with Min. & Max. Marking One
9) Dehydrating Breather One
10) Conservator Drain valve One
11) Air Release plug One
12) Pressure Relief Valve With Trip Contacts One
13) Thermometer Pocket Three
14) Rollers Bi directional Four
15) Radiators Detachable Six
16) Cable box with Disconnecting Chamber [HV] One
17) Bus Duct flange [LV] One
18) Separate Neutral Terminal One
19) Off circuit tap changer One
OTI with Alarm and Trip Contacts
20) One
(CCU for 4-20mA SCADA O/P & In Built RS-485 Port)
21) Buchholz relay with Alarm and Trip Contacts One
22) Radiator Valves Twelve
23) Marshalling Box One
W.T.I. With Alarm and Trip Contacts
24) One
(CCU for 4-20mA SCADA O/P & In Built RS-485 Port)
25) Inspection Cover One
26) Current Transformer One
27) M.O.G. with LOLA Contacts One
28) Buchholz relay with shut off valve Two
29) Jacking Pads Four
30) Sampling Valves Two
31) Explosion vent with double diaphragm and equalizer pipe One
32) Valve Schedule plate One
33) Foundation / Anti earth quake clamps Four
34) Radiator leg supports Six
SHIELD EARTHING TERMINAL ( ES ) 40X6 CUflat Will be
35) One
brought down till roller level with support insulators.
36) Nitrojen injection valve for NIFPS Four
37) Nitrojen drain valve for NIFPS One
38) Mounting brackests for NIFPS sensors As req
39) Mounting brackests for signalling box 1Set
PAGE 3 OF 3
GENERAL ARRANGEMENT 1
H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11
7SR1003
(50,51,50N,
51N,95) 16W VAA33 VAA33 EH
(49) (49)
MFM DA DV
L/R TPB TS1 EPB
TNC
743
33KV ICOG PANEL
2750
2750
NEW
LOGO
550 4 550
6
5
PLS DO NOT
TOUCH
*
7
AUTHORIZED
8
*
TECHNICIAN
OPERATABLE
9
10
11
*
12
33000 VOLTS
INCOMING
100(TYP.)
75
75
1100 1100
SINGLE LINE DIAGRAM
LEGEND
SYMBOLS
TERMINAL BLOCK
PANEL & INTER PANEL WIRING
FUSE
TB IN CONNECTED POSITION
TB IN DISCONNECTED POSITION
NO CONTACT
NC CONTACT
MCB
INDICATION LAMP
WITHDRAWABLE VCB
CURRENT TRANSFORMER
SPACE HEATER
ANSI CODES
1. 50,51,50N,51N,95 - 3 OVER CURRENT+1 EARTH FAULT
& TRIP CIRCUIT SUPERVISION
2. 86 - MASTER TRIP
3. 94 - ANTIPUMPING
4. 49 - AUX. RELAY FOR TRANSORMER FAULT
& ALARM
5. 80 - DC SUPERVISION
6. 27,59 - UNDER /OVER VOLTAGE
7. 30 - 16W ANNUNCIATOR
1. H1 - R PHASE
2. H2 - Y PHASE ABBREVATIONS
QTY - 1NO 3. H3 - B PHASE 1. VAA11 - DC SUPERVISION RELAY
4. H4 - VCB ON 2. VAA33 - TRANSFORMER AUX RELAY
5. H5 - VCB OFF 3. 7SR1003 - FEEDER PROTECTION RELAY
6. H6 - AUTO TRIP 4. VAJH13 - MASTER TRIP RELAY
7. H7 - TEST POSITION 5. MPVR-03 - UNDER / OVER VOLTAGE RELAY
8. H8 - SERVICE POSITION 6. MFM - MULTIFUNCTION METER
9. H9 - SPRING CHARGED 7. DA - DIGITAL AMMETER
10. H10 - TRIP CIRCUIT HEALTHY 8. DV - DIGITAL VOLTMETR
11. H11 - DC FAIL 9. EH - ELECTRICAL HOOTER
12. TPB - CHECK TRIP CIRCUIT HEALTHY 10. LR - LOCAL REMOTE SELECTOR SWITCH
13. EPB - EMERGENCY TRIP PB 11. TNC - TRIP NEUTRAL CLOSE SELECTOR SWITCH
Typical SCADA System Architecture For
4MW Solar Power Project
STATIC IP WEB
CLIENT
User 3 nos
FL SWITCH
14CU+2FO
RTU
Wireless
Communication Hardwired Signals
SMB-07 SMB-06
Single Mode FO Cable
SI.NO DESCRIPTION PAGE NO
9 HT PANEL DETAILS 21
Smart Pyranometers
The more intelligent way to measure solar irradiance
Introduction
Solar radiation drives almost every dynamic process on the Earth’s surface and above, from ocean current circulation to the weather,
and life itself. Precise long-term measurements of the radiation budget at the surface are fundamental to understanding the Earth’s
climate system and weather forecasting, and are important in agriculture, hydrology and ecology. Accurate solar radiation data has
also become crucial information in solar energy and other industrial applications.
Kipp & Zonen has been manufacturing pyranometers for over signal processing and interfaces optimised for industrial data
80 years. These instruments are designed for measuring the acquisition and control systems. Kipp & Zonen has developed
total (global) irradiance from the sun and sky falling on a a smart interface that features Modbus® data communication
plane surface in the wavelength range from 300 nm (nano- for connection to programmable logic controllers (PLC’s),
meters) to 3000 nm. We produce models at all price and inverters, digital control equipment and the latest generation
performance points, up to the very best available, designed of data loggers. Amplified Voltage or Current outputs are also
for a long operating life in all environments, from deserts to included for devices that have high level analogue inputs or
the Antarctic. current loop interfaces.
Our pyranometers meet, or exceed, the requirements of ISO The smart interface not only provides versatile outputs. An
9060:1990 and IEC 60904 and are fully traceable to the integrated temperature sensor and digital polynomial
World Radiometric Reference (WRR) in Davos, Switzerland, functions provide correction for the temperature sensitivity
where Kipp & Zonen instruments form part of the World of the detector. The response time has been improved and
Standard Group. the output ranges are standardised, making it easy to
interchange instruments for recalibration. Using Modbus® a
Now, Kipp & Zonen makes the link between our class- range of instrument status and configuration information is
leading instruments and industry standard interfaces to available, with user-selectable options.
bring you something completely new, the SMP series of
smart pyranometers. SMP pyranometers have extremely low power consumption so
that internal heating does not affect the detector performance.
Building on the proven CMP Series design and technology that is They operate from a wide range of supply voltages, making
used around the world, the new SMP pyranometers add digital them ideal for power-critical applications.
Interfacing
SMP Series pyranometers are equipped with a smart interface. There are two versions, one has an analogue output of 0 to 1 V,
the other is 4 to 20 mA. Both have a 2-wire RS-485 interface with Modbus® (RTU) protocol. All the outputs are protected against
short-circuits, and reversed polarity.
The analog outputs allow easy connection to virtually any keeps the same analog and digital measurement ranges, so
data logger or without the need for sensitive mV inputs. saving time by eliminating re-scaling of data collection
Modbus® interfaces directly to RTU’s, PLC’s, SCADA systems, equipment.
industrial networks and controllers. Not only measurement
data is available, the user can access the pyranometer type SMP Series pyranometers can operate from a power
and serial number, instrument settings, calibration history, supply in the range from 5 VDC to 30 VDC and have both
status information, and more. A recalibrated instrument reverse polarity and over-voltage protection.
0 to 1 V Voltage meter
Irradiance W/m²
analogue Data logger
SMP-V
Irradiance W/m²
Raw data
Enhanced data
Data aquisition system
Instrument type
5 to 30 VDC RS-485 PLC
Serial number
Power Supply Modbus® RTU
Calibration history
Computer
Internal temperature
Response acceleration
Power supply voltage
Current meter
4 to 20 mA
Data logger Irradiance W/m²
analogue
Industrial control system
SMP-A
Choice of Pyranometer
To achieve the required spectral and directional characteristics SMP3, SMP10 and SMP11 come in two versions; ‘-V’ with a 0 to 1
SMP Series pyranometers use thermopile detectors and glass V analogue output, and ‘-A’ with 4 to 20 mA. Both versions have
domes. SMP3, SMP10 and SMP11 both have built-in bubble the Modbus® interface, very low power requirements and are
levels and adjustable levelling feet. Snap-on sun shields reduce supplied with comprehensive, traceable, calibration certificates.
solar heating of the housings. The waterproof connectors have The most appropriate model for an application largely depends
gold-plated contacts and are fitted with 10 m of high quality on the desired accuracy and performance.
signal cable as standard.
Building a System
The system capabilities of Kipp & Zonen pyranometers can
be extended with our wide range of compatible products
and accessories, including; mountings, ventilation unit,
adjustable tilt mounting kit, shadow ring, sun trackers and
data loggers.
Please refer to our website www.kippzonen.com for more information on the above products and other accessories available.
Ø32 mm Ø50 mm Ø50 mm
68 mm
68 mm
68 mm
HEAD OFFICE
Kipp & Zonen B.V.
Delftechpark 36, 2628 XH Delft
P.O. Box 507, 2600 AM Delft
4414333-V1411
The Netherlands
+31 (0) 15 2755 210
info@kippzonen.com
www.kippzonen.com
Kipp & Zonen B.V. reserve the right to alter specifications of the equipment described in this documentation without prior notice