Component - Plastics                                                                                                                                                        E41938
Guide Information                                                               View Certificate of Compliance
CELANESE INTERNATIONAL CORP
8040 DIXIE HWY, FLORENCE KY 41042-2904
FR50(+)(f1)
Polyamide 66 (PA66), flame retardant, glass reinforced "Zytel", furnished as pellets
                        Min. Thk                   Flame                                                    RTI Elec                   RTI Imp                   RTI Str
Color                   (mm)                       Class                        HWI            HAI          (°C)                       (°C)                      (°C)
ALL                     0.35                       V-0                          -              -            -                          -                         -
                        0.75                       V-0                          0              0            130                        105                       105
NC, BK                  1.5                        V-0, 5VA                     0              0            130                        115                       115
                        3.0                        V-0, 5VA                     0              0            130                        115                       120
            Comparative Tracking Index (CTI): 2                                              Inclined Plane Tracking (IPT) kV: -
                    Dielectric Strength (kV/mm): 25                                        Volume Resistivity (10x ohm-cm): 11
                                                                                                                  Surface Resistivity
   High-Voltage Arc Tracking Rate (HVTR): 1                                                                                           -
                                                                                                                 (10x ohms/square):
                         Dimensional Change (%): -                                           High Volt, Low Current Arc Resis 6
                                                                                                                     (D495):
           (+) - Virgin and regrind up to 50% by weight inclusive, have the same basic material characteristics.
           (f1) - Suitable for outdoor use with respect to exposure to Ultraviolet Light, Water Exposure and Immersion in accordance with UL 746C.
         NOTE - (1) Material designations that are color pigmented may be followed by suffix letters and numbers. (2) Material designations may be prefixed by
                 "ZYT" for Zytel or "MIN" for Minlon or "CRA" for Crastin or "RYN" for Rynite.
  ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the
      flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL.
Report
Date:          1996-08-20
Last           2022-07-04
Revised:
                                © 2024 UL Solutions
IEC and ISO Test Methods
Test Name                                  Test Method                        Units           Thk (mm)   Value
Flammability                               IEC 60695-11-10, IEC 60695-11-20   Class (color)   0.35       V-0 (ALL)
                                                                                              0.75       V-0 (ALL)
                                                                                              1.5        V-0, 5VA (NC, BK)
                                                                                              3.0        V-0, 5VA (NC, BK)
Glow-Wire Flammability (GWFI)              IEC 60695-2-12                     °C              0.75       960
                                                                                              1.5        960
                                                                                              3.0        960
Glow-Wire Ignition (GWIT)                  IEC 60695-2-13                     °C              0.75       900
                                                                                              1.5        900
                                                                                              3.0        930
IEC Comparative Tracking Index       IEC 60112        Volts (Max)   -   -
IEC AC Dielectric Strength (AC DS)   IEC 60243-1      kV/mm         -   -
IEC DC Dielectric Strength (DC DS)   IEC 60243-2      kV/mm         -   -
IEC Volume Resistivity (VR)          IEC 62631-3-1    10x ohm-m     -   -
IEC Surface Resistivity (SR)         IEC 62631-3-2    10x ohms      -   -
IEC Inclined Plane Tracking (IPT)    IEC 60587        kV            -   -
IEC Ball Pressure                    IEC 60695-10-2   °C            -   240
ISO Heat Deflection (1.80 MPa)       ISO 75-2         °C            -   -
ISO Tensile Strength                 ISO 527-2        MPa           -   -
ISO Flexural Strength                ISO 178          MPa           -   -
ISO Tensile Impact                   ISO 8256         kJ/m2         -   -
ISO Izod Impact                      ISO 180          kJ/m2         -   -
ISO Charpy Impact                    ISO 179-1        kJ/m2         -   -