Component - Plastics E41938

Guide Information View Certificate of Compliance

CELANESE INTERNATIONAL CORP


8040 DIXIE HWY, FLORENCE KY 41042-2904

FR50(+)(f1)
Polyamide 66 (PA66), flame retardant, glass reinforced "Zytel", furnished as pellets
Min. Thk Flame RTI Elec RTI Imp RTI Str
Color (mm) Class HWI HAI (°C) (°C) (°C)
ALL 0.35 V-0 - - - - -
0.75 V-0 0 0 130 105 105
NC, BK 1.5 V-0, 5VA 0 0 130 115 115
3.0 V-0, 5VA 0 0 130 115 120
Comparative Tracking Index (CTI): 2 Inclined Plane Tracking (IPT) kV: -
Dielectric Strength (kV/mm): 25 Volume Resistivity (10x ohm-cm): 11
Surface Resistivity
High-Voltage Arc Tracking Rate (HVTR): 1 -
(10x ohms/square):
Dimensional Change (%): - High Volt, Low Current Arc Resis 6
(D495):
(+) - Virgin and regrind up to 50% by weight inclusive, have the same basic material characteristics.

(f1) - Suitable for outdoor use with respect to exposure to Ultraviolet Light, Water Exposure and Immersion in accordance with UL 746C.

NOTE - (1) Material designations that are color pigmented may be followed by suffix letters and numbers. (2) Material designations may be prefixed by

"ZYT" for Zytel or "MIN" for Minlon or "CRA" for Crastin or "RYN" for Rynite.

ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the

flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL.
Report

Date: 1996-08-20

Last 2022-07-04

Revised:

© 2024 UL Solutions

IEC and ISO Test Methods


Test Name Test Method Units Thk (mm) Value
Flammability IEC 60695-11-10, IEC 60695-11-20 Class (color) 0.35 V-0 (ALL)
0.75 V-0 (ALL)
1.5 V-0, 5VA (NC, BK)
3.0 V-0, 5VA (NC, BK)
Glow-Wire Flammability (GWFI) IEC 60695-2-12 °C 0.75 960
1.5 960
3.0 960
Glow-Wire Ignition (GWIT) IEC 60695-2-13 °C 0.75 900
1.5 900
3.0 930
IEC Comparative Tracking Index IEC 60112 Volts (Max) - -
IEC AC Dielectric Strength (AC DS) IEC 60243-1 kV/mm - -
IEC DC Dielectric Strength (DC DS) IEC 60243-2 kV/mm - -
IEC Volume Resistivity (VR) IEC 62631-3-1 10x ohm-m - -
IEC Surface Resistivity (SR) IEC 62631-3-2 10x ohms - -
IEC Inclined Plane Tracking (IPT) IEC 60587 kV - -
IEC Ball Pressure IEC 60695-10-2 °C - 240
ISO Heat Deflection (1.80 MPa) ISO 75-2 °C - -
ISO Tensile Strength ISO 527-2 MPa - -
ISO Flexural Strength ISO 178 MPa - -
ISO Tensile Impact ISO 8256 kJ/m2 - -
ISO Izod Impact ISO 180 kJ/m2 - -
ISO Charpy Impact ISO 179-1 kJ/m2 - -