0% found this document useful (0 votes)
39 views2 pages

FC Iso C

The FC-ISO-C is a high-speed optical isolator module designed to interface incremental encoder signals with PLCs and other devices, supporting input voltages of 4.5-7.5VDC and 12-26VDC. It features optical isolation rated at 1800VAC, three complementary open collector outputs, and a maximum frequency response of 1 MHz. The module is UL508 listed, CE marked, and includes DIP switch settings for simplified wiring and troubleshooting.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
39 views2 pages

FC Iso C

The FC-ISO-C is a high-speed optical isolator module designed to interface incremental encoder signals with PLCs and other devices, supporting input voltages of 4.5-7.5VDC and 12-26VDC. It features optical isolation rated at 1800VAC, three complementary open collector outputs, and a maximum frequency response of 1 MHz. The module is UL508 listed, CE marked, and includes DIP switch settings for simplified wiring and troubleshooting.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

FC-ISO-C Encoder Signal Conditioner and Specifications (continued) Dimensions inch [mm]

Optical Isolator - Open Collector Output General Specifications

External DC Power Required


Product Guide 7.8-24VDC ± 10% @ 125mA, 3.5W*

Power Dissipation Within Module 10W (maximum power with all outputs at max current and max voltage)
3505 HUTCHINSON ROAD
Description: CUMMING, GA 30040-5860 Thermal Dissipation 34.13 BTU/hr (1W = 3.413 BTU/hr)

The FC-ISO-C high speed optical isolator module has the versatility to solve various interface
problems between an incremental encoder signal and a PLC, servo drive, or other input device. Ideal 1800VAC input-output
for use with single ended (open collector, NPN, pull-up, push-pull, totem pole) or differential line
Isolation
applied for 1 second
driver encoder signals, the three complementary inputs (A, B, Z, A-not, B-not, Z-not) are rated for
4.5-7.5 and 12-26VDC and frequency response up to 1 MHz. Input terminals A, B, and Z can be
internally connected together and complementary input terminals A-not, B-not, and Z-not can be
Mounting 35mm DIN Rail or panel mount (with no restrictions)

internally connected to common through DIP switches for simplified wiring. The FC-ISO-C has three
complementary open collector outputs (A, B, Z, A-not, B-not, Z-not) rated for 5-36VDC that can be
used in single ended configurations. The open collector output terminals can be connected to internal
0 to 60°C (32 to 140°F)
Operating Temperature
pull-up resistors through DIP switches for quick troubleshooting. Optical isolation rated at 1800V
IEC 60068-2-14 (Test Nb, Thermal Shock)

separates the input signals from the outputs. The slim-line plastic housing includes an integral 35mm
DIN rail mounting adapter, LED indication, and removable screw terminal blocks for easy installation
and wiring. The FC-ISO-C module is UL508 listed and CE marked.
-20 to 70°C (-4 to 158°F)
IEC 60068-2-1 (Test Ab, Cold)
Storage Temperature
IEC 60068-2-2 (Test Bb, Dry Heat)
IEC 60068-2-14 (Test Na, Thermal Shock)

Specifications
Input Specifications 5 to 95% (non-condensing)
Humidity
Input Voltage (DIP selectable) 4.5-7.5 VDC 12-26 VDC IEC 60068-2-30 (Test Db, Damp Heat)
Input Current 9mA typical, 18mA maximum
Protection Type, Component Surge, Suppressor Diode; Over current/temperature, Microprocessor Environmental Air No corrosive gases permitted (EN61131-2 pollution degree 1) Wiring Connections Input Terminal Block
Switching Threshold “0” Signal < 2.2 VDC < 3.9 VDC Faceplate Label Description
MIL STD 810C 514.2
Vibration +Ai A Input Non-Inverted
IEC 60068-2-6 (Test Fc)
Switching Threshold “1” Signal > 2.6 VDC > 4.8 VDC -Ai A Input Inverted
MIL STD 810C 516.2 FC-ISO-C +Bi B Input Non-Inverted
Output Specifications Shock +Ai
IEC 60068-2-27 (Test Ea) +Ai
Output Circuit Open collector: 2-wire - floating or pull-up (DIP switch selectable); Sinking -Ai -Ai -Bi B Input Inverted

>10M Ω @ 500 VDC


+Bi +Bi
Output Rating 5-36VDC Input -Bi -Bi 8 +Zi Z Input Non-Inverted
Insulation Resistance
Continuous Output Current 65mA maximum Terminal +Zi +Zi
-Zi Z Input Inverted
Block -Zi -Zi

Overcurrent Trip Level 76mA minimum COM COM COM Input Common
COM COM

Quiescent Current 25µA maximum COM Input Common


NEMA ICS3-304 V+ V+ + POWER

Output Voltage Protection Polarity reversal, surge voltage protection Power 7.8-24VDC±10%
125mA
IEC 61000-4-2 (ESD)
Terminal 0V 0V
External Power Terminal Block
Output Current Protection Short circuit/Over Current/Over Current Limiting/Thermal Shutdown on FC-ISO-C Noise Immunity
Impulse 1000V @ 1µS pulse Block Ao Ao
IEC 61000-4-4 (FTB) Ao Ao
Timing Specifications Bo
Faceplate Label Description
RFI, (145MHz, 440MHz 5W @ 15cm) Bo
ON(1) =
Bo
Input to Output Response Time 1.3µs (max w/ 4.7k ohm internal pull-up resistor) Bo 1 2 3 V+ 7.8VDC to 24VDC ±10%
IEC 61000-4-3 (RFI) Output Zo Zo
Ao Ao
Rise Time (ton w/ 1k ohm Load) 250ns Terminal Zo Zo 0V 0V Connection
Fall Time (toff w/ 1k ohm Load) 38ns
Block 0V 0V

0V 0V
Output Terminal Block
Max Frequency Response w/ 1k ohm Load 1 MHz
Weight 0.3 lbs
Rise Time (ton w/ 2.2k ohm Load) 512ns Faceplate Label Description
Fall Time (toff w/ 2.2k ohm Load) 56ns Agency Approvals UL*, cUL (File # E157382), CE
Ao A Output Non-Inverted

Max Frequency Response w/ 2.2k ohm Load 750kHz __ A Output Inverted


* in order to comply with UL508 the supplied power must be less than 26VDC and fused at a maximum of 3 amps. Ao
Rise Time (ton w/ 4.7k Internal Pull-Up) 1.2µs
Bo B Output Non-Inverted
Fall Time (toff w/ 4.7k Internal Pull-Up) 25ns __ B Output Inverted
Max Frequency Response w/ 4.7k Internal Bo
200kHz
Pull-Up Zo Z Output Non-Inverted
Terminal Block Specifications __ Z Output Inverted
Zo
Number of Positions 2 pole (Dinkle: EC350V-02P), 8 pole (Dinkle: EC350V-08P)
0V Output 0V Reference
Wire Range 28-16AWG Solid or Stranded Conductor; Wire strip length 9/32” (6-7mm)
0V Output 0V Reference
Screw Size (Slotted) M 2.5 size, 0.4 T x 2.5 W mm (Screwdriver part number DN-SS1)
Screw Torque 1.7 inch-pounds (0.19 Nm)
P.1
DIP Switch Settings Output Equivalent Circuit V+ Terminal
(24VDC External Power)
Typical Wiring Diagrams
Open Collector Connections
Remove Cover Cable shield is not connected to the encoder body;
DIP Switch to connect pull-up Internal 4.7K Pull-Up DIP Switch 1

enclosure is grounded through the 0V wire


resistor (1 for each output)
for DIP Switch 1 Use pull-up resistor for quick
Resistor
Input DIP 1 2 3 4 5 6 7 8
trouble shooting of outputs. Setup 0 0 0 1 1 0 0 0

PLC, Servo Controller,


VFD or other digital
Output Terminal 12345678 input device requiring
+Ai
DIP Switches
ches isolation
FC-ISO-C

-
24VDC
-Ai
+Bi SIGNAL CONDITIONER Each Intput Point FC-ISO-C Internal

+
8 7 6 5 4 3 2 1 OC / DD INPUT (Logic Side)
-Bi +Ai
OC OUTPUT
+Zi INPUT SWITCH
5-36VDC / 65mA -Ai SW4
0V Terminal Blue: 0 V +Bi
-Zi

4.5 - 7.5VDC / 9 mA
+Ai,+Bi,+Zi SNK-IN
SW5

12 - 26VDC / 9 mA
-Bi

-Ai,-Bi,-Zi SRC-IN
COM
COM ENCODER Brown: Power source* +Zi
-Zi
COM

V+ + POWER 1 0 1 +Ai Black: OUT A COM

7.8-24VDC±10%
0V 125mA 2 0 1 +Bi
White: OUT B

INPUT SETTINGS
Ao
3
4 1
0 1 +Zi
Status Indicators V+
Fuse
24 VDC
Ao 0V

Bo
5 1
Orange: OUT Z
ON(1) = PULL UP OFF(0) = OC 6 1 -Ai
Bo 7 1 -Bi Status Indicators A
Zo
1 2 3 4 5 6 7 8
8 1 -Zi
Shield: Ground Ao

Zo
Ao Ao N.C. Bo Bo N.C. Zo Zo Indicator Status Description FC-ISO-C
Ao
Bo
A/
0 +Ai
0V
On Input A is receiving signal -Ai
* Use separate power supply to maintain isolation Bo
Zo
B
0V 1 Zo B/
Input A LED +Bi
0V Z
-Bi
Off No signal receiving on input channel A 0V Z/
+Zi
-Zi GND
COM

Line Driver Connections


On Input B is receiving signal COM
Remove Cover Input B LED
Cable shield is not connected to the encoder body;
DIP Switch 1
for DIP Switch 2 Off No signal receiving on input channel B
V+

enclosure is grounded through the 0V wire


0V Input DIP 1 2 3 4 5 6 7 8
Ao
Setup 1 1 1 0 0 0 0 0
DIP Switch 1 - Switches 1, 2, 3 On Input Z is receiving signal INPUT A LED Ao
Bo
Input Voltage Level Selection 1 2 3 Input Z LED
Bo 12345678
4.5V - 7.5VDC Ai 1 - - Off No signal receiving on input channel Z INPUT B LED Zo
Zo
DIP Switches
12V - 26VDC Ai 0 - - INPUT C LED 0V
FC-ISO-C
4.5V - 7.5VDC Bi - 1 - 0V Brown: Power source*
+Ai
-Ai
12V - 26VDC Bi - 0 -
ENCODER Blue: 0 V +Bi
-Bi PLC, Servo Controller,
4.5V - 7.5VDC Zi - - 1 +Zi VFD or other digital
12V - 26VDC Zi - - 0 Black: OUT A -Zi
input device requiring
COM
COM
isolation
Purple: OUT A
DIP Switch 1 - Switches 4, 5
Input Connection Options 4 5 White: OUT B V+
Fuse

0V
24 VDC
Internally Connect Ai+ to Bi+ 1 - Gray: OUT B
Internally Connect Bi+ to Zi+ - 1 A

Internally Connect Ai+, Bi+, and Zi+ 1 1


Typical Application Orange: OUT Z
Ao
Ao A/

Convert a 5VDC differential line driver


Bo
ISOLATION
No internal connection between Ai+, Bi+, Zi+ 0 0 Yellow: OUT Z Bo

encoder signal to a 24VDC open collector


B
BARRIER Zo
B/
Zo

single ended signal that is compatible with a


DIP Switch 1 - Switches 6, 7, 8 Shield: Ground 0V Z
Z/

PLC high speed counter interface module.


0V
ERR
OK
Input Connection Options 6 7 8 GND
A
Y0 * Use separate power supply to maintain isolation
Internally Connect Ai- to COM 1 - - Y1

Single-Ended Line Driver Connections


B
Internally Connect Bi- to COM - 1 - CTR/TMR IN 9-30V 5-12mA
DC/Pulse OUT 5-36V 1A DIP Switch 1

Cable shield is not connected to the encoder body;


OUT
Internally Connect Zi- to COM - - 1 A Input DIP 1 2 3 4 5 6 7 8

enclosure is grounded through the 0V wire


Internally Connect Ai-, Bi-, Zi- to COM 1 1 1 FC-ISO-C B Setup 1 1 1 0 0 1 1 1
Brown: Power source* C
+Ai
No internal connection from Ai+, Bi+, Zi+ to COM 0 0 0 D PLC, Servo Controller,
ENCODER Blue: 0 V -Ai
M 12345678
VFD or other digital
+Bi
Black: OUT A YC input device requiring
DIP Switch 2 - Switches 1 to 8 (see output equivalent circuit diagram) -Bi
Y0 DIP
P Switches isolation
Purple: OUT A +Zi
Y1 FC-ISO-C SW6
Output Settings 1 2 3 4 5 6 7 8 White: OUT B
-Zi OUT
Brown: Power source* Internal
COM H0-CTRIO +Ai
-Ai
SW7
Differential Line COM
Ao 4.7kΩ Pull-Up 1 - - - - - - - Driver Encoder
Gray: OUT B ENCODER Blue: 0 V +Bi
SW8
-Bi

Ao Open Collector 0 - - - - - - - Orange: OUT Z +Zi


V+
PLC High Speed Counter
Black: OUT A -Zi
0V
Ao NOT 4.7kΩ Pull-Up - 1 - - - - - - Yellow: OUT Z Interface Module
COM
COM

Ao NOT Open Collector - 0 - - - - - - Shield: Ground Ao


Ao
+

-24VDC
Bo 4.7kΩ Pull-Up - - - 1 - - - - Bo
White: OUT B V+
Fuse
24 VDC
* Use separate power supply to maintain isolation Bo 0V
Bo Open Collector - - - 0 - - - - Zo
A
Bo NOT 4.7kΩ Pull-Up - - - - 1 - - - Zo
Ao
0V Orange: OUT Z Ao A/
Bo NOT Open Collector - - - - 0 - - - 0V Bo
Bo
Zo 4.7kΩ Pull-Up - - - - - - 1 - Zo B
Zo B/
Zo Open Collector - - - - - - 0 - Shield: Ground 0V Z
Z/
0V
Zo NOT 4.7kΩ Pull-Up - - - - - - - 1
GND P.2
Zo NOT Open Collector - - - - - - - 0 * Use separate power supply to maintain isolation