MAS-DX-08-D-XX
Doc. Ref No.m11C/om/101
                                                                                                                           Issue No.:03
INDEX
SPECIFICATION ................................................................................................................................................. 1
CONFIGURATION AND CONNECTION ........................................................................................................ 2
SAFETY AND WARNING ................................................................................................................................. 2
INSTALLATION ................................................................................................................................................... 2
APPLICATION .................................................................................................................................................... 1
ORDERING CODE ............................................................................................................................................. 3
TROUBLE SHOOTING ...................................................................................................................................... 3
                                                MAS-DX-08-D-XX
                                                                                                           Doc. Ref No.: m11C/om/101
                                                                                                           Issue No.:03
                   8-Channel AC Input Module
•    Masibus 8-Channel AC Input Module is designed to interface variety of
     Analog signals from Field Power terminals to automation units like                            8-CHANNEL AC INPUT MODULE
     PLC/DCS/SCADA.
•    The module has wide AC input and DC output ranges, to match various
     customer requirements.
•    It is available in compact footprints in 35mm DIN rail mounting. Its input
     and output connections are labeled for easy installation, operation and
     maintenance.
•    This module provides up to 1.5KVAC galvanic isolation between input,
     output and supply for rugged, stable and reliable operations.
•    It has 18-36VDC auxiliary power supply. These modules are validated to
     be used even in harsh environment up to 50˚C ambient temperature and
     95% relative humidity (Non-condensing)
    APPLICATION
         •   Industrial process control
         •   Factory automation
         •   SCADA
         •   DAS
    SPECIFICATION
    Input
                                                                                                        Multi-channel configurations
    Input Range                   Current: 0-5A AC, 0-1A AC, 0-300mA AC
                                  Voltage: 0-150V AC, 0-300V AC, 0-450V AC                              Wide range of AC inputs and DC
    Input burden                  Current I/P: < 0.1VA                                                   outputs
                                  Voltage I/P: < 0.5 VA for 450VAC I/P                                  Isolates field signal from DCS/PLC
    Overload current              20A max
                                                                                                         DIN rail mounted
    Input connection              Barrier Terminal (3.0 mm2conductor)
    Output                                                                                              Independent zero & span for each
    Output Range                  Current: 4 – 20 mA DC                                                  channel
                                  Voltage: 0 to 5VDC, 1 to 5VDC, 0 to 10VDC                             Compact Size
    Response Time                 To 90%: ≤200ms max,                                                   Easy to calibrate
                                  To 99%: ≤400ms max
                                                                                                        Re-Transmission to Interface
    Accuracy                      For Voltage I/P: 0.25% of rated full scale output from 10% to
                                  110% of rated input range                                              with DAS/SCADA/PLC
                                  For Current I/P: 0.25% of rated full scale output from 5% to 110% of
    Drift
                                  rated input range
                                  0.1% per Year
                                                                                                   1. Dimension
    O/P connection                25 pin D Type connector
    Load                          for Current O/P - ≤ 650 Ohms
                                  for Voltage O/P - ≥ 3.9K
    Power supply
    Power Supply                  18-36VDC
    Supply connection             Screwed, up to 2.5 mm2 conductor
    Power Consumption             < 6 watt
    Fuse Rating                   2Amp (Fast Blown)
    LED Indication                Green LED – Healthy Status
                                  Red LED –Fault Status
    Isolation                     I/P to O/P, supply -1.5KVRms for one minute
                                  O/P to Supply-1.5KVDC for one minute
    Environmental
    Working temperature           0 to 50ºC
    Temp. Co-efficient            ≤ 150 PPM
    Relative humidity             30 to 95% RH (Non-Condensing)
    Protection                    Conformal Coating on PCB
                                                                                                          300mmx126mmx91mm (HxWxD)
    Physical
    Mounting Type                 DIN RAIL (35 mm) Mounting
    Dimensions                    300 mm X 126 mm X 91 mm (H x W x D)
    Weight                        Less than 600 gm
    Terminal Detail
    Terminal Block                UL,CSA standard & CE certified
                                            MAS-DX-08-D-XX
                                                                              Doc. Ref No.: m11C/om/101
                                                                              Issue No.:03
SAFETY AND WARNING
                                                             Connection details:
To ensure that the device can be operated safely
and all functions can be used, please read these             Connection details of MAS-DX-08-D-XX
instructions carefully.
       Caution: Never carry out work when the
       Power is turned on, this is dangerous.
Installation and startup must be carried out by
qualified personnel only. The relevant country-specific
regulations (e.g., VDE, DIN) must also be observed.
Before startup it is particularly important to ensure:
• Terminal wiring:
Check that all cables are correctly connected                Note: Connect DC(+) to (+) terminal and
according to the connection diagram.                         DC(-) to (-)terminal as shown on terminal.
• The mains has been connected correctly and
  protection is provided against electric shock.             Connecting Cable:
• The device can be switched off outside the power            Pin No.   Description
  supply according to EN 60950 regulations (e.g., by          1         Output0+
  the line protection on the primary side)                    2         Output0-
• All supply lines should have sufficient fuse                3         Output1+
  protection and are of correct size.                         4         Output1-
• All output cables are of correct size for the               5         Output2+
                                                                                         Output
                                                              6         Output2-
  maximum device output current or have separate                                         Connection
                                                              7         Output3+
  fuse protection.                                            8         Output3-         Details for
• Sufficient convection is ensured.                           9         Output4+         25 Pin D
  After installation the terminal area must be                10        Output4-         type
  covered to provide sufficient protection against            11        Output5+
  unauthorized access to live parts.                          12        Output5-
  This is ensured by installing the device in the             13        Output6+
  control cabinet or distributor box.                         14        Output6-
CONFIGURATION AND CONNECTION                                  15
                                                              16
                                                                        Output7+
                                                                        Output7-
Control Elements for MAS-DX-08-D-XX
                                                             Only operate connectors when the power is
                                                             switched off.
                                                             INSTALLATION
                                                             Mounting On DIN Rail – MAS-DX-08-DXX
 Item
          Details
 nos.
                                                             Mounting:
          Aux. Supply(18-36VDC) with electronic
   1      grounding                                          The unit can be snapped onto all DIN rails
   2      Fuse Fail LED indication
                                                             according to EN 60715. The device must be
   3      Power ON LED indication                            mounted horizontally (input terminal blocks
   4      Male interface connector to DCS                    facing downwards)
   5      Field input terminals (Barrier type)
   6      Product serial no.                                 Installation Dimensions:
                                                                   To ensure sufficient convection,       a
                                                                   minimum spacing of 1 cm is required
                                        MAS-DX-08-D-XX
                                                                                Doc. Ref No.: m11C/om/101
                                                                                Issue No.:03
Place the module with the DIN rail guide way                   expected value. Kindly make sure that the output is
on the bottom edge of the DIN rail and then                    really incorrect with respect to input signal, before
snap it downwards.                                             attempting any re-calibration.
The housing is mounted on the DIN rail by
                                                               Account for measuring instrument’s inaccuracies,
swiveling it into place.
                                                               lead errors and calibration errors. Care must be taken
As air vents are provided on the top and
                                                               when measuring Output signal.
bottom part of the unit, the (Horizontal)
mounting arrangement allows good vertical air                  Use calibrating instrument of accuracy better than
circulation.                                                   0.1% for purpose of calibration. If the signal is still
   asibus Automation & Instrumentation Pvt. Ltd.
 masibus                                                       found to be out of tolerance, calibration should be
 B/30, GIDC Electronics Estate, Sector- 25,                    required.
 Gandhinagar-382044, Gujarat, India
 Ph: 91-079-23287275 / 76 / 77 / 78 / 79
 Fax: 91-079-23287281/ 82
 Email: support@masibus.com
 Web: www.masibus.com
       Vertical   mounting     arrangement     of
       multiple units must be avoided.
Removal:
Release the snap-on catch using a
screwdriver and then detach the module from
the bottom edge of the DIN Rail.
ORDERING CODE
                        Ordering Code
                     MAS-DX-08-D-XX
 Input Signal      Input Range          Output Range
      X                 X                     X
                 1    0-5A AC     1        4-20mA DC
                 2    0-1A AC     2         0-5V DC
 A     Current
                 3 0-300mA AC     3         0-10V DC
                                  4         1-5V DC
                 1    0-150V AC   1       4-20mA DC
                 2    0-300V AC   2         0-5V DC
 V     Voltage
                 3    0-450V AC   3        0-10V DC
                                  4        1-5V DC
TROUBLE SHOOTING
     Unit Not Turning ON?
The problem can be bad connection / power of
incorrect rating.
First check,power on terminal of the       instrument; if it
is not present, then the fault is in power chord.
       One must take care while dealing with Power
       wirings because it may create electrical shock.
     Unstable/Vague Reading
     Check for loose connections.
     Output not matching with the expected value
 It is a normal tendency to doubt the instrument
 performance, when the Output is not matching the