MAS-DX-08-D-XX

Doc. Ref No.m11C/om/101


Issue No.:03

INDEX

SPECIFICATION ................................................................................................................................................. 1
CONFIGURATION AND CONNECTION ........................................................................................................ 2
SAFETY AND WARNING ................................................................................................................................. 2
INSTALLATION ................................................................................................................................................... 2
APPLICATION .................................................................................................................................................... 1
ORDERING CODE ............................................................................................................................................. 3
TROUBLE SHOOTING ...................................................................................................................................... 3
MAS-DX-08-D-XX
Doc. Ref No.: m11C/om/101
Issue No.:03

8-Channel AC Input Module


• Masibus 8-Channel AC Input Module is designed to interface variety of
Analog signals from Field Power terminals to automation units like 8-CHANNEL AC INPUT MODULE
PLC/DCS/SCADA.
• The module has wide AC input and DC output ranges, to match various
customer requirements.
• It is available in compact footprints in 35mm DIN rail mounting. Its input
and output connections are labeled for easy installation, operation and
maintenance.
• This module provides up to 1.5KVAC galvanic isolation between input,
output and supply for rugged, stable and reliable operations.
• It has 18-36VDC auxiliary power supply. These modules are validated to
be used even in harsh environment up to 50˚C ambient temperature and
95% relative humidity (Non-condensing)

APPLICATION
• Industrial process control
• Factory automation
• SCADA
• DAS
SPECIFICATION
Input
 Multi-channel configurations
Input Range Current: 0-5A AC, 0-1A AC, 0-300mA AC
Voltage: 0-150V AC, 0-300V AC, 0-450V AC  Wide range of AC inputs and DC
Input burden Current I/P: < 0.1VA outputs
Voltage I/P: < 0.5 VA for 450VAC I/P  Isolates field signal from DCS/PLC
Overload current 20A max
 DIN rail mounted
Input connection Barrier Terminal (3.0 mm2conductor)
Output  Independent zero & span for each
Output Range Current: 4 – 20 mA DC channel
Voltage: 0 to 5VDC, 1 to 5VDC, 0 to 10VDC  Compact Size
Response Time To 90%: ≤200ms max,  Easy to calibrate
To 99%: ≤400ms max
 Re-Transmission to Interface
Accuracy For Voltage I/P: 0.25% of rated full scale output from 10% to
110% of rated input range with DAS/SCADA/PLC
For Current I/P: 0.25% of rated full scale output from 5% to 110% of

Drift
rated input range
0.1% per Year
1. Dimension
O/P connection 25 pin D Type connector
Load for Current O/P - ≤ 650 Ohms
for Voltage O/P - ≥ 3.9K
Power supply
Power Supply 18-36VDC
Supply connection Screwed, up to 2.5 mm2 conductor
Power Consumption < 6 watt
Fuse Rating 2Amp (Fast Blown)
LED Indication Green LED – Healthy Status
Red LED –Fault Status
Isolation I/P to O/P, supply -1.5KVRms for one minute
O/P to Supply-1.5KVDC for one minute
Environmental
Working temperature 0 to 50ºC
Temp. Co-efficient ≤ 150 PPM
Relative humidity 30 to 95% RH (Non-Condensing)
Protection Conformal Coating on PCB
300mmx126mmx91mm (HxWxD)
Physical
Mounting Type DIN RAIL (35 mm) Mounting
Dimensions 300 mm X 126 mm X 91 mm (H x W x D)
Weight Less than 600 gm
Terminal Detail
Terminal Block UL,CSA standard & CE certified
MAS-DX-08-D-XX
Doc. Ref No.: m11C/om/101
Issue No.:03

SAFETY AND WARNING


Connection details:
To ensure that the device can be operated safely
and all functions can be used, please read these Connection details of MAS-DX-08-D-XX
instructions carefully.
Caution: Never carry out work when the
Power is turned on, this is dangerous.

Installation and startup must be carried out by


qualified personnel only. The relevant country-specific
regulations (e.g., VDE, DIN) must also be observed.
Before startup it is particularly important to ensure:
• Terminal wiring:
Check that all cables are correctly connected Note: Connect DC(+) to (+) terminal and
according to the connection diagram. DC(-) to (-)terminal as shown on terminal.
• The mains has been connected correctly and
protection is provided against electric shock. Connecting Cable:
• The device can be switched off outside the power Pin No. Description
supply according to EN 60950 regulations (e.g., by 1 Output0+
the line protection on the primary side) 2 Output0-
• All supply lines should have sufficient fuse 3 Output1+

protection and are of correct size. 4 Output1-

• All output cables are of correct size for the 5 Output2+


Output
6 Output2-
maximum device output current or have separate Connection
7 Output3+
fuse protection. 8 Output3- Details for
• Sufficient convection is ensured. 9 Output4+ 25 Pin D
After installation the terminal area must be 10 Output4- type
covered to provide sufficient protection against 11 Output5+
unauthorized access to live parts. 12 Output5-
This is ensured by installing the device in the 13 Output6+
control cabinet or distributor box. 14 Output6-

CONFIGURATION AND CONNECTION 15


16
Output7+
Output7-

Control Elements for MAS-DX-08-D-XX


Only operate connectors when the power is
switched off.

INSTALLATION
Mounting On DIN Rail – MAS-DX-08-DXX

Item
Details
nos.
Mounting:
Aux. Supply(18-36VDC) with electronic
1 grounding The unit can be snapped onto all DIN rails
2 Fuse Fail LED indication
according to EN 60715. The device must be
3 Power ON LED indication mounted horizontally (input terminal blocks
4 Male interface connector to DCS facing downwards)
5 Field input terminals (Barrier type)
6 Product serial no. Installation Dimensions:

To ensure sufficient convection, a


minimum spacing of 1 cm is required
MAS-DX-08-D-XX
Doc. Ref No.: m11C/om/101
Issue No.:03
Place the module with the DIN rail guide way expected value. Kindly make sure that the output is
on the bottom edge of the DIN rail and then really incorrect with respect to input signal, before
snap it downwards. attempting any re-calibration.
The housing is mounted on the DIN rail by
Account for measuring instrument’s inaccuracies,
swiveling it into place.
lead errors and calibration errors. Care must be taken
As air vents are provided on the top and
when measuring Output signal.
bottom part of the unit, the (Horizontal)
mounting arrangement allows good vertical air Use calibrating instrument of accuracy better than
circulation. 0.1% for purpose of calibration. If the signal is still
asibus Automation & Instrumentation Pvt. Ltd.
masibus found to be out of tolerance, calibration should be
B/30, GIDC Electronics Estate, Sector- 25, required.
Gandhinagar-382044, Gujarat, India
Ph: 91-079-23287275 / 76 / 77 / 78 / 79
Fax: 91-079-23287281/ 82
Email: support@masibus.com
Web: www.masibus.com

Vertical mounting arrangement of


multiple units must be avoided.

Removal:
Release the snap-on catch using a
screwdriver and then detach the module from
the bottom edge of the DIN Rail.

ORDERING CODE
Ordering Code
MAS-DX-08-D-XX

Input Signal Input Range Output Range


X X X
1 0-5A AC 1 4-20mA DC
2 0-1A AC 2 0-5V DC
A Current
3 0-300mA AC 3 0-10V DC
4 1-5V DC

1 0-150V AC 1 4-20mA DC
2 0-300V AC 2 0-5V DC
V Voltage
3 0-450V AC 3 0-10V DC
4 1-5V DC

TROUBLE SHOOTING
Unit Not Turning ON?
The problem can be bad connection / power of
incorrect rating.
First check,power on terminal of the instrument; if it
is not present, then the fault is in power chord.
One must take care while dealing with Power
wirings because it may create electrical shock.

Unstable/Vague Reading
Check for loose connections.
Output not matching with the expected value
It is a normal tendency to doubt the instrument
performance, when the Output is not matching the

You might also like