Perkin Elmer HPLC Consumables
Perkin Elmer HPLC Consumables
com/supplies
Chromatography
Consumables and Supplies
Genuine PerkinElmer Products — Genuine Value
on Crimp Top
Headspace Vials!
See page 51 for details.
AU 1800033391 IN912225701101
KR 8228685350 SG 6567799555
ordering information
Order by Mail
Visit us online at www.perkinelmer.com/lasoffices
to obtain the correct address for mailing your
company Purchase Order.
See page 55 for details. NEW Series 225 Autosampler and Accessories. . . . . . 8–9 6
See page 2 for a complete listing of local offices and for ordering information. 3
New Series 275 HRes™ LC System from
Includes:
Series 275 Autosampler with Peltier cooling/heating option, Vacuum Degasser, Series
275 Binary Micro Pumps, Series 200 Column Oven, and Series 200 UV/Vis Detector
with high efficiency 2.4 μL flow cell and dotLink interface. Communication Cables, Static
Mixer and all Low Dead-volume Fittings, Pre-cut Tubing and connections necessary to
configure system included. TotalChrom Software and HRes columns sold separately.
See page 2 for a complete listing of local offices and for ordering information. 5
series 275 LC autosampler and accessories
Expanded
Capabilities with
high throughput
performance
Interferene
Binary Mixing-T
CheckMixers
Standards
Interferene Check Standards
Syringes Description Part No.
150 μL HP Binary High Pressure Mixing-T, SS N2911206
Description Part No. 10 μL Binary Mixing-T, SS N2911170
Sample Needle w/fittings N2936009
Air Guide Needle (62 mm) N2936000
Bio Compatible Sample Needle w/tubing Connector N2936010
High Pressure Stainless Steel
Sample Loops
Solvent and Sample Filtration The high integrity 3/16 stainless steel loops are ideal for both High Pressure
and general LC applications and ferrules come in a full range of sizes.
Syringe filters are important for high pressure applications of effectively
filter samples to prevent premature column performance loss and These loops are required for the Series 275 Autosampler, especially for
possible flow restriction of the narrow tubing that is typically required applications requiring ≥ 6,000 psi back pressure.
for high pressure LC applications.
Interferene
High Pressure
Check
Static
Standards
Mixers
Interferene
Syringe Filters
Check Standards
Description Part No.
Description Pore Size Part No.
2 μL Sample Loop, SS N2936071
PVDR 13 mm Filter (pkg. 100) 0.45 μm 02542783 5 μL Sample Loop, SS N2936056
PTFE 13 mm Filter (pkg. 100) 0.45 μm 02542782 10 μL Sample Loop, SS N2936057
20 μL Sample Loop, SS N2936058
Nylon 17 mm Filter (pkg. 100) 0.45 μm 02542880 50 μL Sample Loop, SS N2936059
Nylon 17 mm Filter (pkg. 100) 0.20 μm 02542881 100 μL Sample Loop, SS N2936060
Nylon 30 mm Filter (pkg. 100) 0.45 μm 02542882 200 μL Sample Loop, SS N2936061
Nylon 30 mm Filter (pkg. 100) 0.20 μm 02542883 500 μL Sample Loop, SS N2936062
PTFE 17 mm Filter (pkg. 100) 0.20 μm 02542884 1 mL Sample Loop, SS N2936063
2 mL Sample Loop, SS N2936064
PTFE 30 mm Filter (pkg. 100) 0.45 μm 02542885 5 mL Sample Loop, SS N2936065
PTFE 30 mm Filter (pkg. 100) 0.20 μm 02542886
See page 2 for a complete listing of local offices and for ordering information. 7
Series 225 LC Autosampler and
Performance beyond
Expectations – always
0.2 mL Micro Vials, Caps, and Septa 2.0 mL Vials, Caps and Septa
Description Part No. PerkinElmer Autosampler Vials are guaranteed for fit and compatibility with the
Series 200 Autosampler. Both vials and caps are totally inert to samples ordinarily
Caps/Septa analyzed by Liquid Chromatography.
Polyethylene Press-on Cross-slit Cap for 8 mm o.d. Vials N9302141
(pkg. 1,000) Crimp-on Caps
Aluminum Crimp-top Cap with Teflon-lined Butyl 03300806 Description Size Part No.
Rubber Septa for 8 mm Vials (pkg. 1,000) Crimp Green (pkg. 100) 11 mm N9302684
Crimp Top Vials Aluminum cap with Teflon®/rubber
Glass MicroVials, Tapered, 0.2 mL, 8 mm o.d. Top N9302136 Crimp Red (pkg. 100) 11 mm N9302685
(pkg. 500) Aluminum cap with Teflon/rubber
Crimp Blue (pkg. 100) 11 mm N9302686
Autosampler Vial Sleeve Aluminum cap with Teflon/rubber
Glass N9307027 Crimp Silver (pkg. 100) 11 mm N9306015
Micro Vial Kit Aluminum cap with Teflon/rubber
Polyethylene N9306080
Includes 300 μL tapered vial, blue Crimp Top Vials
polypropylene cap with bonded Type 1 borosilicate standard glass vials, 2.0 mL, 11 mm o.d. top.
silicone/PTFE septa. (pkg. 500)
Description Size Part No.
Amber Glass Vials (pkg. 100) 11 mm N9302680
Clear Glass Vials (pkg. 100) 11 mm N9301385
6 mL Vials and Caps Screw Top Vials and Caps – Wide Mouth
Description Part No. Type 1 borosilicate standard glass vials, 2.0 mL, 12 x 32 mm.
Caps/Septa Description Size Part No.
Polyethylene Press-on Slit Cap for 20 mm o.d. Vials N2936083 Amber Glass Vials (pkg. 100) 12 mm N9306057
(pkg. 25) Clear Glass Vials (pkg. 100) 12 mm N9306053
Crimp Top Vials Screw-top Vial Caps, black (pkg. 100) 10 mm N9306052
Polypropylene with PTFE/slit
Glass Large-volume Vials, 6.0 mL, 20 mm o.d. Top N9302134
white silicone
(pkg. 125)
See page 2 for a complete listing of local offices and for ordering information. 9
Brownlee Conventional Columns from
Save up to 20%
on your next Brownlee Cartridge
or Conventional Columns order!*
To qualify, use promotion code: LCBLC408
Save 15% when you buy any 2 Brownlee Cartridge or Conventional Columns!
Save 20% when you buy any 3 Brownlee Cartridge or Conventional Columns!
*Use of the LCBLC408 promotion code is required to receive your discount. Discount cannot be combined with volume purchase agreement discounts, university program discounts,
standing order discounts or other contract pricing. Discounts cannot be combined with promotion available at time of instrument purchase. Offer expires 3/31/09.
Brownlee Columns
Choose only genuine PerkinElmer BrownleeTM columns
for the best separation results. Six different column
types to meet all your analytical needs.
Conventional Columns
Column Functionality Pore Diameter Å % Carbon End Cap Applications
Analytical Amino 110 2 No Excellent for carbohydrate analysis
Analytical C18 & C8 110 13 Yes Superior for non-basic analytes
Analytical Cyano 110 4 Yes General purpose for normal or reversed-phase
Analytical Biphenyl 110 – Yes U.S. EPA Method 8330
Analytical Phenyl 110 6 Yes General purpose for neutral analytes
Analytical Silica 110 – – Ideal for polar analytes
Analytical PAH 110 – Yes Maximum resolution of polynuclear aromatic hydrocarbons
Aquapore® AX-300 300 – – Used for ion exchange chromatography
Aquapore Octyl C8 300 – – Used for reversed-phase chromatography
Aquapore ODS C18 300 – – Silica based support used for the separation of large biopolymers
Bio C18 300 6 Yes High molecular weight compounds and proteins
Bio C8 300 – – High molecular weight compounds and proteins
CHOICE™ Basix 60 12 Yes Ideal for LC/MS. Excellent for amine-containing compounds
and basic pharmaceuticals
CHOICE C18 60 27 Yes Excellent for explosives or steroids
CHOICE Biphenyl 60 23 Yes Highly retentive and selective phase for aromatic compounds
CHOICE Organic acids 60 – No Used for challenging organic acids
CHOICE PFP propyl 60 17 Yes Ideal for MS, ELSD, or NPD detection of nucleosides, nucleotides,
purines, pyrimidines or halogenated compounds
Spheri-5® C8, C18, C18 ODS and Silica 80 – – Excellent for separating small molecules both
non-functional and polyfunctional
Validated™ Amino 100 2 No Ideal for carbohydrates
Validated C1 100 5 – Least retentive reversed-phase hydrocarbon packing
Validated C4 100 9 Yes High bonding coverage and base deactivation
Validated Aqueous C18 100 15 No Excellent for highly water-soluble or poorly organic-soluble compounds
Validated C18 100 20 Yes Used for the detection of anilines, barbiturates, carbonyls, fat-soluble
vitamins, fatty acids, glycerides, phthalates
Validated C8 100 12 Yes Less hydrophobic retention than C18
Validated Carbamate 100 – – Fast analysis of carbamates
Validated Cyano 100 8 Yes Basic pharmaceuticals and steroids
Validated IBD 100 12 No Unique separation for acids, bases, zwitterions and other polar compounds
Validated PFP 100 7 Yes Ideal for taxors and precursors or halogenated compounds
Validated Phenyl 100 10 Yes Separation of fatty acids, polynuclear aromatic hydrocarbons,
purines and pyrimidines
Validated Quat 100 – – High purity, base deactivated reversed-phase packing
See page 2 for a complete listing of local offices and for ordering information. 11
Conventional Columns for all HPLC
Brownlee Analytical pH Range: 2.5 to 7.5 Brownlee Bio pH Range: 2.5 to 7.5
Particle Temp. Pore Carb. End Particle Temp. Pore Carb. End
Length i.d. Size Limit Size Load Cap Part No. Length i.d. Size Limit Size Load Cap Part No.
Brownlee Analytical Amino Brownlee Bio C8
Ideal for mono and disaccharide analyses. Most popular amino-based stationary Wide-bore HPLC column. High proportion of pore/surface
phase. Routine analysis of simple sugars, using isocratic elution and a refractive area available for large molecule separations.
index detector or an evaporative light scattering detector. 150 mm 2.1 mm 5 μm 300 Å 6% Yes N9303658
100 mm 4.6 mm 5 μm 80 °C 110 Å 2% No N9303503 150 mm 4.6 mm 5 μm 300 Å 6% Yes N9303659
150 mm 4.6 mm 5 μm 80 °C 110 Å 2% No N9303504
Brownlee Bio C18
Brownlee Analytical C8 Excellent for separating peptides or proteins. Wide-pore HPLC column.
Shorter retention times for hydrophobic compounds. Reliable performance 150 mm 2.1 mm 5 μm 300 Å 5% Yes N9303648
with symmetrical peak shapes for neutral to acidic compounds. 150 mm 4.6 mm 5 μm 300 Å 6% Yes N9303649
100 mm 4.6 mm 5 μm 80 °C 110 Å 7% Yes N9303515
150 mm 4.6 mm 5 μm 80 °C 110 Å 7% Yes N9303517
See page 2 for a complete listing of local offices and for ordering information. 13
Brownlee Cartridge Columns for Quality
Brownlee Sorbents
PerkinElmer Brownlee™ cartridge columns are offered in a wide range of
sorbent material. Choose the right sorbent for the analysis and mode of
separation being used.
Save up to 20%
on your next Brownlee Cartridge
or Conventional Columns order!*
To qualify, use promotion code: LCBLC408
Save 15% when you buy any 2 Brownlee Cartridge or Conventional Columns!
Save 20% when you buy any 3 Brownlee Cartridge or Conventional Columns!
*Use of the LCBLC408 promotion code is required to receive your discount. Discount cannot be combined with volume purchase agreement discounts, university program discounts,
standing order discounts or other contract pricing. Discounts cannot be combined with promotion available at time of instrument purchase. Offer expires 3/31/09.
See page 2 for a complete listing of local offices and for ordering information. 15
Brownlee MPLC Cartridge Columns for
Ion Exchange
30 mm x 4.6 mm i.d.* 30 mm x 2.1 mm i.d.* 100 mm x 4.6 mm i.d.**
2 per package 2 per package 1 per package
Column Description Part No. Part No. Part No.
Polar Phase
30 mm x 4.6 mm i.d.* 30 mm x 2.1 mm i.d.* 100 mm x 4.6 mm i.d.**
2 per package 2 per package 1 per package
Column Description Part No. Part No. Part No.
Amino, Spheri-5 ®
Aminopropyl, 5 μm, 80 Å 07110037 07110039
Cyano, Spheri-5 Cyanopropyl, 5 μm, 80 Å 07110043 07110045
Silica, Spheri-5 5 μm, 80 Å 07110031 07110032 07110033
Silica, Spheri-10 10 μm, 80 Å 07110145
Reversed Phase
30 mm x 4.6 mm i.d.* 30 mm x 2.1 mm i.d.* 100 mm x 4.6 mm i.d.**
2 per package 2 per package 1 per package
Column Description Part No. Part No. Part No.
Scavenger Columns
33 mm x 4.6 mm i.d.*
5 per package
Column Description Part No.
Ion Exchange
100 mm x 2.1 mm i.d.** 220 mm x 4.6 mm i.d.*** 220 mm x 2.1 mm i.d.***
1 per package 1 per package 1 per package
Column Description Part No. Part No. Part No.
Polar Phase
100 mm x 2.1 mm i.d.** 220 mm x 4.6 mm i.d.*** 220 mm x 2.1 mm i.d.***
1 per package 1 per package 1 per package
Column Description Part No. Part No. Part No.
Reversed Phase
100 mm x 2.1 mm i.d.** 220 mm x 4.6 mm i.d.*** 220 mm x 2.1 mm i.d.***
1 per package 1 per package 1 per package
Column Description Part No. Part No. Part No.
* Requires Holder (07150028) ** Requires Holder (07150014) *** Requires Holder (07150015)
See page 2 for a complete listing of local offices and for ordering information. 17
Brownlee NewGuard Cartridge Columns
MPLC/Peco™ Holders
The patented MPLC cartridge system ensures leak-free operation up to 7000 psi, with only finger-tightening. The high-pressure seal in each end assembly actually seals
tighter as pressure increases. No wrenches are required, and there is no need to disconnect any tubing to your LC system when changing a cartridge. Each MPLC cartridge
can be directly coupled to another using a union.
Name Description Part No.
Universal Holder Kit Includes 100 and 220 mm holder bodies, 07150025
2 end assemblies, 1 union, 1 NewGuard end assembly.
NewGuard® Holder Holds a single NewGuard cartridge or a single 20 mm 07150001
CHOICE™ cartridge.
30 mm Holder Holds a single MPLC and CHOICE 30 mm cartridge. 07150013
See page 2 for a complete listing of local offices and for ordering information. 19
sample loops
Tubing Accessories
Description Part No.
Clean-Cut Tubing ED020015
Clean-Cut Tubing Replacement Blade ED020016
PEEK Tubing
PEEK tubing has the strength
required to withstand continuous
use at HPLC pressure without
PEEK Sample Loops swelling or bursting. The
dense polymer structure of
Sample loops are made from PEEK tubing and fittings. PEEK PEEK tubing eliminates the
(poly-ether-ether-ketone) is a mechanically-strong, chemically-inert permeability to organic solvents
polymer, ideal for HPLC applications where metal surfaces may that causes other polymer tubing,
interact with the mobile phase or sample component. Each sample Tubing and Connectors
such as Tefzel ®, to sweat.
loop is supplied with two PEEK hex-head nuts and ferrules. These
fittings grip the tubing in two locations for a more reliable connection. Use PEEK with virtually any organic or inorganic liquid. PEEK tubing is
not affected by halide salts, high-strength buffers or other aggressive
Description Size Part No. mobile phases that degrade stainless steel.
PEEK Sample Loop 20 μL N9306035
PEEK Sample Loop 50 μL N9306036
PEEK Sample Loop
Internal Loop (PEEK and Ceramic)
200 μL
2 μL
N9306038
N9306022
PEEK Tubing
Description Length Part No.
1
⁄16 in o.d. x 0.007 in i.d. 5 ft N9302678
Stainless Steel Sample Loops ⁄16 in o.d. x 0.010 in i.d. 5 ft N9302650
1
Fittings Kits
Biocompatible Column Fittings for LC. Recommended for users of a
PerkinElmer Biocompatible LC system. Contains nuts, ferrules
and unions.
Stainless Steel Fittings
Stainless steel nuts are available in both Parker-Hannifin and Part No.
Rheodyne™ formats. The nuts are used to connect 1⁄16 inch o.d. N9301001
stainless steel tubing and feature a 10-32 thread size. PerkinElmer
also offers select SSI fittings for 1⁄16 inch o.d. tubing in 1⁄4 -28 thread size. Fittings Kit for LC
All-in-one fittings kit. The kit contains Rheodyne™ and SSI nuts
and ferrules as well as Fingertight ® II nuts and ferrules for toolless
Stainless Steel Fittings installation. Zero-dead-volume unions are also included. In addition
you receive varying lengths of stainless steel tubing in 0.007 and
Description Part No. 0.010 inch i.d.s, as well as 0.30 inch i.d Tefzel® tubing.
Parker-Hannifin Ferrule, ⁄16 inch
1
00873032 Part No.
Parker-Hannifin Nut, 1⁄16 inch 09903980
Parker-Hannifin Nut & Ferrule Kit, 1⁄16 inch 00890945 N9301002
Includes: 6 nuts and 6 ferrules
Parker-Hannifin Zero-Dead-Volume Union 09903289
Operation Kit
with nuts and ferrules Recommended for purchasers of their first LC. Includes tubing, union,
Rheodyne™ Ferrule, 1⁄16 inch 09904947 fittings, syringe, basic LC book and test mix.
Rheodyne™ Nut, 1⁄16 inch long body 09904974
Part No.
Rheodyne™ Nut, 1⁄16 inch short body 09904956
Rheodyne™ Nut and Ferrule Kit, 1⁄16 inch 02540274 00890873
Includes: 6 ferrules, 3 short nuts and 3 long nuts
See page 2 for a complete listing of local offices and for ordering information. 21
Enhance the Performance of your HPLC
Check Valves
Inlet/Intermediate Outlet
Check valve Check valve
Type Part No. Part No.
Standard Stainless Steel 02540177 02540197
Micropump 02540177 02540197
Biocompatible Titanium N2600226 N2600192
Part No.
N2910520
Mixing Heads
Size Part No.
75 μL N2910521
Mixing Head
200 μL N2910522
400 μL N2910523
See page 2 for a complete listing of local offices and for ordering information. 23
supplies and accessories
For both the Rheodyne and Flom valves, rotor seals should be periodically Description Part No.
replaced every 6 months to a year and are available in PEEK. For the
8125 Low-Dispersion Stainless Steel Injection Valve N9306021
Rheodyne valve, they are also available in Vespel. PEEK is more inert
towards amines and other basic biomolecules/pharmaceuticals,
exhibiting less sample carryover. However, Vespel is somewhat Rheodyne ™ 7725 Analytical Injection Valve
more resilient than PEEK, providing somewhat better wear life. Inject from 1 μL to 5 mL with high accuracy and precision,
Description Part No. with the Rheodyne™ 7725 and 7725i valves.
Flom Rotor Seal PEEK N9306068 Rheodyne™ 7725 and 7725i valves are versatile injectors and can use
Rheodyne 7725 Vespel Rotor Seal 09904802 both partial-filling and complete-filling methods for loading the sample
Rheodyne 8125 Vespel Rotor Seal 10070900 loop. Wide port angles of the 7725/7725i valve provide improved
Rheodyne 7725/9725 PEEK Rotor Seal N9306044 access to fittings. Sample loop with a 2 μL internal capacity is also
available. In a clean system, the 7725/7725i typically can make more
than 30,000 injections before requiring replacement of the rotor seal.
For a full listing of Rheodyne ™ Description Part No.
injection valves, please visit:
www.perkinelmer.com/lcsupplies 7725 Injection Valve for Series 200 Autosampler N9306019
7725i Injection Valve with Internal Switch N9306017
Series 200
Description Material Size Part No.
Detector Backpressure Regulator Standard Flowcell Assembly Stain. Steel 12 μL, 10 mm N2922028
The detector backpressure regulator is a device that is attached Flowcell Assembly PEEK 12 μL, 10 mm N2922029
to the outlet of the detector to prevent outgassing in the flowcell, Low-volume Flowcell Assembly Stain. Steel 5 μL, 4.5 mm N2922030
eliminating variations to the detector baseline. LC-135C/235
Description Material Part No. Description Material Size Part No.
Backpressure Regulator Stainless Steel 09907126 Flowcell Assembly Titanium 8 μL N2350211
Adjustable from 15 – 59 psi
See page 2 for a complete listing of local offices and for ordering information. 25
autosampler vials
LC-240
For our complete listing of Components Part No.
HPLC detector lamps, please visit:
www.perkinelmer.com/lcsupplies
Xenon Lamp L2251157
Festoon Lamp 04969486
See page 2 for a complete listing of local offices and for ordering information. 27
software
IRIS spectral
processing software
Introduction
With the continued need to increase productivity and enhance the
quality of analytical results, the use of photo diode array (PDA)
detectors continues to grow rapidly. However, in order to truly utilize the
power, performance and wealth of data generated by a PDA detector,
an equally powerful software package is essential.
User Interaction
IRIS features an Outlook™-like graphical user interface that facilitates
a short learning curve and allows an easy navigation into information.
A hierarchical relationship and a tree-like structure of data are available Compliance for FDA-Regulated Industries
on screen for a convenient sample tracking. A single environment for
IRIS software provides a complete range of features and functionality
all software functions is available, as well as specific views for certain
to ensure FDA 21 CFR Part 11 compliance and similar regulatory
functions. User-specific customizable views can be prepared for
agencies’ requirements. IRIS software provides multi-level user
needed tasks.
permissions, password-protected access control and full audit-trailing,
as well as configurable e-signature points.
Confirmation of Peak Identity and Purity
One of the most important benefits a PDA detector delivers is the
IRIS Spectral processing Software
confirmation of the identity and/or purity of a chromatographic peak. IRIS is an optional software program for spectral processing of data
IRIS spectral processing software performs automated mathematical acquired from the PerkinElmer S200 Diode Array Detectors. Requires
processing, determining the similarity of spectra within every peak in IPM for PerkinElmer LC Modules (N5150162) for control of S200.
the run. This is a necessary tool to calculate spectral peak purity, Also requires TotalChrom or TurboChrom 6.3.1 or higher.
providing critical information on the efficiency of the separation. This
Part No.
resulting purity value is then automatically inserted into the final
TotalChrom chromatography report and available for the Review N5150130
& Approve process. Also available in the report is the maximum
absorbance wavelength of each peak. This “Lambda Max” value
is useful in confirming the proper identity of the component.
PerkinElmer LC
Separation Notes CD
Enjoy the convenience of:
■ References to separations conducted on 516 compounds
or class of compounds
■ References point to over 230 LC applications – just one click away
■ Information on the column used in the application
■ Analytical conditions such as flow, gradient and solvents
■ A labeled chromatogram with information on the compounds,
matrix and sample preparation
■ Application by industry
■ Applications presented in a one page template for easy printing
■ CD also contains a full electronic copy of the Consumables and
Supplies reference catalog
See page 2 for a complete listing of local offices and for ordering information. 29
clarus 600 gas chromatograph
Take your GC/MS to the limit with the A model for every lab’s needs:
Clarus ® 600 Gas Chromatograph/
Mass Spectrometers (GC/MS). Clarus 600 C GC/MS:
■ Electron ionization and chemical ionization with 255 L/sec turbomolecular pump
It provides the performance and
throughput you require with the Clarus 600 T GC/MS:
ruggedness you demand. ■ Electron ionization with 255 L/sec turbomolecular pump
See page 2 for a complete listing of local offices and for ordering information. 31
Organic Standards from PerkinElmer GC
Method 524.2 is an analytical method that uses a purge and trap device
for sample preparation and a GC/MS equipped with a capillary column
to perform the separation of volatile organic compounds.
Interferene
Volatile Organics
CheckCombination
Standards Blend
Contains all analytes in Mixes A, C and D.
Method SW-846 is an analytical method which utilizes a Clarus 600 GC to
perform the separation of the volatile organic components found in a variety
PerkinElmer offers a wide selection of GC and GC/MS standards. of solid waste matrices. To detect the GC eluant a Clarus 600 GC/MS is used.
Each solution is supplied with a comprehensive Certificate of
Analysis that documents quality and assurance to the highest level Description Part No.
obtainable by a Calibration Standard. 1.2 mL @ 2,000 μg/mL in P & T Methanol N9331047
To ensure customer satisfaction, our Organic Mixes are prepared Alternate Four-Component Surrogate Standard for Method 8260B
at concentration levels that take into consideration a number of 1.2 mL @ 2,000 μg/mL in P & T Methanol N9331042
factors including: vapor pressure, evaporation, breakdown rates and
dilution schemes. PerkinElmer goes the extra step by analyzing each Internal Standard for Method 8260B
organic standard on the Clarus 600 GC and GC/MS state-of-the-art 1.2 mL @ 2,000 μg/mL in P & T Methanol N9331041
instrumentation, to ensure that the standard conforms to the
customer’s exact needs.
For customer ease, all Organic Standards are prepared with a precision
of +/- 0.5% and accompanied with a comprehensive Certificate of
Analysis (lot specified by part number). Data packs are also available
Interferene
Ketones for Check
MethodStandards
8260B
upon request. These include a chromatogram of the standard and Description Part No.
quantitative report listing the values for each analyte.
1.2 mL @ 2,000 μg/mL in P & T Methanol N9331043
Analyte Mix for Method 8270C Polynuclear Aromatic Hydrocarbons Mix B for Method 8100
1.2 mL @ 2,000 μg/mL in Methanol N9331032 1.2 mL @ 1,000 μg/mL in Methylene Chloride/Benzene N9331045
Balance Mix for Method 8270C Surrogate Standard for Method 8100
1.2 mL @ 2,000 μg/mL in Methylene Chloride N9331033 1.2 mL @ 2,000 μg/mL in Methylene Chloride N9331046
See page 2 for a complete listing of local offices and for ordering information. 33
Inline Gas Purifiers for Clarus GC and
See page 2 for a complete listing of local offices and for ordering information. 35
gc supplies
Essential GC lab
supplies from PerkinElmer
MiniTemp MT4 Non-contact
Temperature Measurement
with Laser Sighting
Features and Benefits
■ Displays thermal measurement readings
in °C or °F
■ Easy point and shot infrared technology
in a pocket size configuration
■ Great for instrument thermal test
confirmation, including GC injector
port and detector measurements,
Portable Gas Leak Detector thermostatted LC vials, and
enzymatic hydrolysis baths
The new PerkinElmer compact handheld electronic gas leak detector is
the ideal solution for detecting gas leaks in your Gas Chromatography
Non-contact Surface Temperature
systems. Leaks in your system waste gas and can cause detector
Measurement with Laser Sighting
noise, baseline instability, and shorter column life. This portable unit
detects minute leaks of any gas with thermal conductivity different from
air. The reference gas inlet draws in ambient air for comparison to air
drawn into the sample probe. A leak is detected by both LED bar graph Specifications
display and audible alarm.
Model MiniTemp MT4
Temperature Range -18 to 400 °C
Detectable Gases (0 to 750 °F)
Distance to Spot Size (D:S) 8:1
Gas Minimum Detectable Indicating LED
Type Leak Rate (atm cc / sec) Light Color Response time 500 m/sec
Emissivity Pre-set at 0.95
Helium 1.0 x 10-5 Red
Hydrogen** 1.0 x 10-5 Red Accuracy ±2%, or ±2°C (±3 °F)
Nitrogen 1.4 x 10-3 Yellow whichever is greater
Argon 1.0 x 10-4 Yellow Typical Distance to Target (Spot) Up to 1.5 m (4 ft)
Carbon Dioxide 1.0 x 10-4 Yellow Laser Sighting Yes
The popular MiniTemp MT4 also includes single dot laser sighting to assist with aiming.
Battery: Rechargeable Ni-MH internal battery pack (6 hours normal 9 volt battery included. Recalibration is not available.
operation)
Universal Power Adapter Set: US, UK, European, Australian plugs
included Description Part No.
Operating Temperature Range: 32-120 °F (0-48 °C) MiniTemp MT4 N9306074
Humidity Range: 0 – 97%
Warranty: 1 Year Basic Tool Kit
Certifications: CE, Japan
Compliance: WEEE, ROHS Description Part No.
Tools come in a tool box for easy storage and use N9301327
Features and Benefits
Kit Includes:
■ Sleek ergonomic, hand-held design with rugged side grips
Open-end Wrench Set (6 pc), Screwdriver Set (6 pc.), Adjustable Wrench (6 in), Chain
■ Automatic shut-off capabilities Nose Pliers (narrow), Wire Cutters, and Wire Strippers
■ Optimized sample flow path
■ LED readout and audible alarm Deluxe Tool Kit
Description Part No.
Description Part No.
Shipped in a plastic tool box for convenient storage N9301328
Portable Electronic Leak Detector N9306089
Soft Carrying Case N9306142 Kit Includes:
Probe (fine tip) N9306063 Open-end Wrench Set (6 pc.), Screwdriver Set (6 pc.), Adjustable Wrench (6 in), Chain
**Caution: The PerkinElmer leak detector is not designed for determining leaks in a combustible Nose Pliers (narrow), Wire Cutters, Wire Strippers, Slip-joint Pliers (6 in), Long Nose
environment. This unit may be used for determining trace amounts of hydrogen in a GC No. 5 Stainless Steel Tweezers (43⁄8 inches), Needle File Set (6 pc.), Allen Key Set (11 pc.
environment only. imperial sizes), and Allen Key Set (9 pc. metric sizes)
material and therefore expand and contract at the same rate, eliminating The Merlin MicroSeal™ septa is a unique replacement
the need to retighten, even after temperature cycling. The base of the septa employing a two-step sealing system and an advanced
SilTite™ ferrule forms a perfect seal with the MS interface, ensuring a elastomer material.
leak-free connection. SilTite™ metal ferrules have a temperature limit well Because the syringe needle does not pierce the septa, there is no
above the temperature capacity of the injector, MS interface or GC oven. debris and ghost peaks are greatly reduced. The MicroSeal™ septa also
reduces the incidence of bent syringe needles and liner contamination.
Description Hole Size Part No. Usable in either manual or autosampler applications, this septa can
improve your productivity and run reliability. Designed to be used with
SilTite Ferrules Starter Kit (pkg. 10)
™
0.4 mm N9306090
23 gauge straight needle syringes. Pressure ranges from 4 to 100 psi
SilTite™ Ferrules Starter Kit (pkg. 10) 0.5 mm N9306091
and injection port temperatures up to 325 °C.
SilTite™ Ferrules Starter Kit (pkg. 10) 0.8 mm N9306092
SilTite™ Ferrules (pkg. 10) 0.4 mm N9306093
SilTite™ Ferrules (pkg. 10) 0.5 mm N9306094 Features and Benefits
SilTite™ Ferrules (pkg. 10) 0.8 mm N9306095
SilTite™ Nuts (pkg. 5) N9306096 ■ Thousands of injections before septa change
■ 2-step sealing system
Capillary Column Ferrules ■ No debris — no ghost peaks
■ Temperatures up to 325 °C
Graphite
■ Pressure ranges 4 to 100 psi
Ferrule of choice for high-temperature applications up to 450 °C.
Graphite seals easily and does not stick to glass columns. ■ Easy installation
®
Graphite/Vespel
15% graphite/85% polyimide ferrule recommended for use with GC/MS Description Pkg. Part No.
systems. Temperature limit 350 °C. Merlin MicroSeal™ Septum Kit N9303344
® Includes: Injector Port Adapter,
Vespel
2 Septa and 1 Nut
Not reusable. Not recommended for fused silica capillary columns. Merlin MicroSeal™ Septum 1 N9303345
Use these ferrules on 1⁄16 inch metal tubing and glass-lined receivers.
Temperature limit 350 °C.
Injector Septa
Capillary Column Ferrules ■ Thermogreen® LB-2 septum, extremely low bleed over a wide range of inlet
temperatures — 100 to 350 °C. Easier needle penetration and high puncture
Nut Graphite Graphite/Vespel® tolerance make this septum ideal for autosamplers. This septum is already
Size Column i.d. / Ferrule i.d. Part No. Part No. conditioned and ready to use
1
⁄16 in 0.18 – 0.25 mm / 0.4 mm 09920104 ■ BTO™ (Bleed Temperature Optimized) injector septa, 11 mm diameter.
1
⁄16 in 0.18 – 0.32 mm / 0.5 mm 09903700 09920105 Maximum recommended operating temperature 300 °C
1
⁄16 in 0.18 – 0.32 mm / 0.5 mm* N9306001 N9306000 ■ PTFE/Silicone injector septa, 11 mm diameter
1
⁄16 in 0.18 – 0.53 mm / 0.8 mm 09920141 09920107
1
⁄8 in 0.18 – 0.53 mm / 1.0 mm 09903394 Description Pkg. Part No.
1
⁄8 in 0.18 – 0.32 mm / 0.5 mm* 09903395 Thermogreen Injector Septa
®
50 N6621028
1
⁄8 in 0.18 – 0.32 mm / 0.5 mm 09903981 Low Bleed Injector Septa 25 N9303343
*2-hole PTFE/Silicone Injector Septa 50 00090652
See page 2 for a complete listing of local offices and for ordering information. 37
syringes
GC injector and
autosampler syringes
Point Style 2
This is a general purpose point style
designed for septum penetration in all
chromatographic techniques. The needle
has a 22° bevel to minimize coring and
needle plugging.
Point Style 3
Needle has a 90° bevel. Point style is
recommended when the syringe is used
for accurate pipetting of liquids. Excellent
Autosampler Syringes for mixing standards of very small volume.
Syringes from PerkinElmer are individually inspected for accuracy
and performance.
Purchase 5 packs of inlet liners on the same order and receive 5% off!
Purchase 10 packs of inlet liners on the same order and receive 10% off!
Offer may not be used in conjunction with other discounts or promotions. Offer expires 3/31/09.
See page 2 for a complete listing of local offices and for ordering information. 39
autosampler vials, caps and septa
1 Pack 10 Packs
Description Pkg. Part No.
Clear Crimp Top Vials and Silver 100 N9300654
Caps with PTFE/Rubber Septa
Clear Screw Top Vials and Black 100 N9301945
Caps with PTFE/Butyl Rubber Septa
Prices shown are per pack price.
Streamlining your laboratory workflow, the entire process from Report templates can perform calculations between different peaks
setting up an analytical method to the final approval of reports in the same sample or even between samples, as well as automate
statistical determination to replicate injections, with full control over
is a streamlined series of operations in TotalChrom.
the output format.
PerkinElmer’s TotalChrom Chromatography Data System (CDS) is
designed to provide laboratories with the total answer to
chromatography data-handling needs. Unsurpassed 21 CFR Part 11 Compliance
for Regulated labs
Introduction The TotalChrom system features Enhanced Security™, a proprietary
protocol for supporting United States FDA 21 CFR Part 11 compliance.
Acquiring, processing, reporting, reviewing and approving data is a
Audit trails and electronic signatures recorded during data acquisition,
streamlined series of operations in PerkinElmer’s TotalChrom CDS, soft-
instrument control and data analysis processes ensure that data
ware designed to fit your laboratory workflow and maximize
integrity is always maintained. System features fully document all
productivity. With its scalable architecture, 21 CFR Part 11 compliance
methods, sequences, and reports, including instrument run logs, and
features and proven algorithms, TotalChrom offers a computing
provide a complete and unambiguous link from the initial experiment to
strategy to manage your chromatography data quickly and securely in
the final results. Multiple TotalChrom “JobTypes” can be created to
both regulated and non-regulated environments.
control who can perform what functions in the system.
When configured with a PerkinElmer Clarus GC or a PerkinElmer Series
200 HPLC system, TotalChrom CDS is the controller and data manager
for the overall system. TotalChrom CDS can also control selected Quickly and Easily Navigate, Review
instruments from other vendors and can acquire data from any chro- and Approve Your Data
matographic system through A/D interface. In the “paper world,” reports need to be reviewed and signed. The
The TotalChrom client/server (TC C/S) data system is the solution in TotalChrom Review & Approve (R&A) feature is a graphical reviewing
multi-user environments. TC C/S systems can easily integrate all environment that allows intuitive navigation into data and reports and
existing chromatographs into a single networked system supporting an provides for the implementation of a data-approval cycle. With TC R&A,
unlimited number of users and an unlimited number of chromatographs. chromatograms, raw data results and reports can be easily viewed and
compared at a glance.
See page 2 for a complete listing of local offices and for ordering information. 41
elite columns
Elite-CLPesticides
Elite-CLPesticides is specially designed to overcome the coelutions
and analyte breakdown typically encountered in chlorinated pesticide For a full listing of
Elite ® capillary columns, please visit:
analyses for U.S. EPA methods 8081, 608 and CLP. Column bleed www.perkinelmer.com/gcsupplies
measured by ECD is extremely low at temperatures greater than
300 °C, which is critical for baking out the column to remove
high-boiling compounds commonly found in pesticide/PCB extracts.
Primary Applications
Chlorinated pesticides and herbicides. U.S. EPA Methods 504, 608,
619, 8081, 8151 and CLP.
■
Low column bleed — ideal for ECD or GC/MS analysis
Exceeds performance criteria for U.S. EPA Methods 8081, 608, CLP
Save on your next
■ Baseline separation in less than 15 minutes Elite Column purchase!*
Description Dimensions Part No. To qualify, use promotion code: GCELC408
Elite-CLPesticides 15 M x 0.25 mm x 0.25 μm N9316661
Elite-CLPesticides 15 M x 0.53 mm x 0.50 μm N9316665
Elite-CLPesticides 15 M x 0.25 mm x 0.20 μm N9316667 Save 15% when you buy any 2 Elite Columns!
Elite-CLPesticides 30 M x 0.32 mm x 0.50 μm N9316664 Save 25% when you buy any 3 Elite Columns!
Elite-CLPesticides 30 M x 0.32 mm x 0.25 μm N9316670
Elite-CLPesticides 30 M x 0.53 mm x 0.42 μm N9316672
*Use of the GCELC408 promotion code is required to receive your discount. Discount cannot be
combined with volume purchase agreement discounts, university program discounts, standing
order discounts or other contract pricing. Discounts cannot be combined with promotion available
at time of instrument purchase. Offer expires 3/31/09.
See page 2 for a complete listing of local offices and for ordering information. 43
elite columns
Universal Connectors
■ Allows for fast, leak-free connections of fused-silica columns
Wafer Scribes
■ The new fused-silica tapered design allows connection of any size column
and is easy to use. (Suitable for 0.1 to 0.53 mm columns) The PerkinElmer ceramic wafer scribe is inexpensive and ideal for
cutting polyimide fused silica capillary columns and guard columns.
Description Part No. The scribe is easy to hold and simple to use. All four sides can be
Universal Connector (pkg. 5) N9302149 used as a cutting tool. (pkg. 10)
Universal Y Splitter (pkg. 1) N9303448
Description Part No.
Polyimide Sealing Resin (5 g) N9301343
Undeactivated Presstight Column Connectors (pkg. 5) N9303962 Wafer Scribes (pkg. 10) N9301376
Biodiesel Application Kit ASTM 6584 20 mm Headspace Crimp Vials 1,000 1 B0104236
19 mm PTFE-Coated/Silicone Caps, Springs & Septa 1,000 1 B4000022
Part No.
20 mm Electronic Crimper, 110 V 1 N9302571
N9300670 20 mm Electronic Crimper 1 N9302594
Application Notes NEW! 1 09936885
Contents: Pkg. Qty. Part No. Polyimide Deactivated 1 N9301357
Autosampler Syringe 5.0 μL (0.47 mm) 1 2 N6101380 Uncoated Tubing / 5 m x 0.32 mm
Elite-5ht Column 15 M x 0.32 mm x .10 μm 1 1 N9316274 Elite-Volatiles / 30 m x 0.25 mm x 1.4 μm 1 N9316388
Elite Guard Column (ht) 5 M x 0.53 mm 1 1 N9316609 Universal Connector 5 1 N9302149
Mini Union Connector Kit – Includes Mini Union and 5 1 N9306128
Nuts, 0.32 mm Ferrules and 0.53 mm Ferrules
11 mm Electronic Crimper 1 1 N9302592 OVI (Organic Volatile Impurities)
Crimp Vials 2 mL 100 5 N9301385
Aluminum Crimp Caps 11 mm Rubber/PTFE 100 5 N9306015
Application Kit for Pharmaceuticals
GC Septa 50 1 N6621028 Part No.
Injector Liner, Hour Glass 1 2 N6101703 Promo Code: GC020801 (see details below) N9300655
See page 2 for a complete listing of local offices and for ordering information. 45
Determination of Residual Solvents-USP
Results
The measure of system suitability for class 1 residual solvents is
determined by the signal-to-noise value for each component.
When analyzing class 1 solvents by procedure A, the criteria of
signal to noise for benzene must be greater than 5:1 and the
signal to noise of the other components must be greater than 3:1.
The experimentally determined signal-to-noise values are
presented in figure 1; the signal to noise achieved ranged from
Introduction 11:1 for carbon tetrachloride, a poorly-responding component
The United States Pharmacopeia (USP) has implemented a when FID detection is used, to 143:1 for 1,1-Dichloroethene, with
revised method for the determination of residual solvents, benzene responding at 89:1.
chapter 467; this revision has brought the methodology of USP
467 into close alignment with European Pharmacopeia (EP) Conclusion
method 2.4.24. The USP and EP determination of class 1 and
Demonstrated here are method and data which operate under
class 2 residual solvents is performed with static headspace
the guidance of and fulfill the performance criteria of both USP
(HS) sample introduction and gas chromatography (GC) with
467 and EP 2.4.24 for the determination of residual solvents in
flame ionization detection (FID); class 3 has flexibility in the
pharmaceutical materials. Recent revisions of these methods
technique, however, it is often included in the HS analysis.
have aligned the analytical techniques to allow for a single
The purpose of this paper is to work under the guidance of the method to meet the criteria of both organizations. Within the
USP and EP to achieve the best method possible for the scope of USP chapter 621 and EP chapter 2.2.28, the injection
analysis of residual solvents, while adhering to USP 467 and volume was reduced to improve peak shape and method
EP 2.4.24 criteria. Discussed will be the analysis of class 1 performance; necessary sensitivity was maintained with the
residual solvents. modified method.
Chromatogram
HEADSPACE CONDITIONS
Headspace Unit: TurboMatrix HS
Needle Temperature: 110 °C
Transfer Line Temperature: 130 °C
Oven Temperature: 80 °C
Thermostat Time: 20 min
Vial Pressurization Time: 1 min
Injection Time: 0.1 min
Column Pressure: 18 psig
Vial Pressure: 18 psig
GC CONDITIONS
Headspace: TurboMatrix HS
Needle Temperature: 110 °C
Transfer Line Temperature: 130 °C
Oven Temperature: 80 °C
Thermostat Time: 20 min
Vial Pressurization Time: 1 min
Injection Time: 0.1 min
Column Pressure: 18 psig
Vial Pressure: 18 psig
Gas Chromatograph: Clarus GC
Analytical Column: Elite - 1301
(30 m x 0.53 mm x 3.0 μm)
Injector temperature (or program): 140 °C
Oven Temp 1: 40 °C
Hold: 20 min
Rate: 10 °C/min
Oven Temp 2: 240 °C
Hold: 20 min
Figure 1: Chromatogram demonstrating the performance of the class 1 system-suitability solution.
Rate: End
Detector Type: FID
Detector Temperature: 250 °C
N9300655
See page 2 for a complete listing of local offices and for ordering information. 47
headspace and headspace trap accessories
Sample Trays
For use on the Mid-Range or High-Capacity headspace sampler.
Transfer Lines
Description Tubing i.d. Length Part No.
Siltek Deactivated Fused-Silica 0.25 mm 5m N9316607
Siltek Deactivated Fused-Silica 0.32 mm 5m N9316608
Miscellaneous Accessories
Description Part No.
Gas Chromatography – Theory and Practice, N1011210
Static Headspace Book by L. Ettre and B. Kolb
TurboMatrix 40
Headspace Trap Cold Trap Options
Headspace Trap instruments only.
Sample Head Assembly Replacement Parts Description Part No.
Description Part No. TurboMatrix HS Trap Cold Trap Tube (Carbopack C) N6200150
1 Platinum/Iridium Needle, Wide-Bore B0144169 TurboMatrix HS Trap Air Monitoring Trap* M0413628
Platinum/Iridium Needle, Small-Bore B0500959 *Trap comes standard with the instrument.
Platinum/Iridium Needle, Jet B0510364
Silcosteel Needle, for Headspace Trap Only N6700130
Stainless Steel Needle, Wide-Bore B0131385
Stainless Steel Needle, Small-Bore B0500987 Headspace Sample Head
Stainless Steel Needle, Jet (ships with instrument) B4000011 Assembly Schematic
2 Needle Seal Assembly (without O-Rings) B0500833
3 O-Ring for Needle Seal Assembly (pkg. 10) B0198110
4 Vespel Ferrule 1/16 in. (pkg. 10) 09920127
5 Male Nut 1/16 in. N9302832
6 GLT Adapter Tube B0503956
GLT Adapter Tube, Silcosteel N6700113
7 Graphite/Vespel Ferrule 1/16 in. x 0.4 mm 09920104
For use with 0.25 mm i.d. Transfer Line, pkg. 10
Graphite/Vespel Ferrule 1/16 in. x 0.5 mm 09903700
For use with 0.32 mm i.d. Transfer Line, pkg. 10
1
8 Nut 1/16 in. Swagelok N9300059
9 Fused-Silica Capillary Transfer Line: 9
0.25 mm i.d. x 5 m length N9301356
8
0.32 mm i.d. x 5 m length N9301357 7
6
5
4
PerkinElmer cap septa are lot tested and certified for impurities to the
level of 1 ppb benzene. Test conditions use the PerkinElmer TurboMatrix
Headspace FID for the analysis, assuring you of the highest quality to
attain reproducible results.
on Headspace Contents:
22 mL Headspace Crimp Vials
Pkg.
100
Qty.
5
Part No.
N9306079
See page 2 for a complete listing of local offices and for ordering information. 49
TurboMatrix Headspace Vials, Caps and
Electronic Crimpers
PerkinElmer’s patented vial and cap design incorporates
pressure-relief features which guarantee safe operation Features and Benefits
with the high pressure typically developed during thermostatting. ■ Universal voltage
Ordinary vials and caps without these safety features may burst. ■ Precision control crimping
■ Ergonomically-designed grip
■ Numerous reproducible crimps from a
single charge
22 mL Headspace Vials ■ Includes standard Black & Decker®
22 mL headspace vials give a maximum liquid sample volume of 15 mL. VersaPak® Gold battery and charger
These vials have a greater wall thickness and round base which enables ■ Fully rechargeable
them to withstand pressure up to 60 psig. Low-volume sampling can be
achieved by using a 6 mL crimp vial and vial adapter. The vial adapter is Description Voltage Part No.
compatible with TurboMatrix HS 16, TurboMatrix HS 40 or Headspace
40 XL instruments; however, it is not compatible with the TurboMatrix 20 mm Electronic Crimper Universal N9302594
HS 110 headspace sampler. All PerkinElmer headspace vials are with global mains plug pack
manufactured to specific tolerances that are guaranteed to fit within 20 mm Electronic Decapper Universal N9302595
PerkinElmer instruments. Other manufacturers’ vials do not meet these with global mains plug pack
exact manufacturing specifications and can damage the instrument. 11 mm Electronic Crimper Universal N9302592
Damage to the instrument under these circumstances will void the with global mains plug pack
PerkinElmer warranty agreement. 11 mm Electronic Decapper Universal N9302593
with global mains plug pack
Electronic Crimper Battery N9302585
Rechargable Battery N9302596
■
PerkinElmer septa designed for the patented pressure release cap
Provided in resealing Mylar® bags for cleanliness and storage
Caps and Septa!
■ Available pre-assembled into caps with starsprings Use promotion code: GCHSV408
■ Batch tested to the level of 1 ppb benzene
■ Tested for VOCs
Savings available on packs of 1,000. Bulk quantity discounts not available on packs of 125 or less.
Offer may not be used in conjunction with other discounts or promotions. **Not compatible with TurboMatrix Headspace 110.
See page 2 for a complete listing of local offices and for ordering information. 51
thermal desorption
Cold Traps
TurboMatrix Thermal Desorption Trap Supplies Cold Traps Fittings and Accessories
Trap supplies from PerkinElmer, the market leader in thermal desorption, will Description Qty. Part No.
provide exceptional analytical performance. Used for U.S. EPA Method TO17, the
PerkinElmer standard trap, packed with Tenax™, on the TurboMatrix™ Thermal Graphite Ferrule 2 L4271187
Desorber, will improve productivity and trapping capacity. The TurboMatrix air SilTite™ Ferrule (GC/MS) 0.4 mm 10 N9306093
monitoring trap is packed with carbonaceous sorbents suitable for ozone SilTite™ Ferrule (GC/MS) 0.5 mm 10 N9306094
precursor and air toxics monitoring. SilTite™ Ferrule (GC/MS) 0.8 mm 10 N9306095
SilTite™ Nuts 5 N9306096
Description Qty. Part No. PTFE Ferrule 10 L4275110
Cold Traps for TurboMatrix Graphite/Vespel® Ferrule for ATD 400 5 L1003027
Air Monitoring Trap 1 M0413628 Valco® Graphite/Vespel® Ferrule for ATD 400 5 L1003028
Empty Trap 1 M0413627 Trap Filter Disk L1003030
Tenax™ TA 60/80 Packed Trap 1 M0413535 Trap Packing Disk 20 L4271290
Carbopack® C Packed Trap 1 N6200150 Trap Packing Retaining Spring 5 N6301054
Quartz Wool (untreated) 5g N6102354
Cold Traps for ATD 400 Cold Trap Packing Tool L4271203
Air Monitoring Trap 1 L4275108 Cold Trap Removal Tool L4271205
Trap Nuts (2 required) 1 L4275009 Regulator 0–60 psig N6101474
Trap Tube Low Flow, Empty 1 L4275107 Backflush Nozzle for ATD 400 L4275072
(Narrow-bore at one end. Allows minimum Internal Standard Injection Accessory for ATD 400 L4270010
gas flow during trap desorption) Liquid Nitrogen Accessory for ATD 400 L4270009
Tenax™ TA 60/80 Packed Trap 1 L4275089 Gauze Loading Rig L4070023
Empty Trap 1 L4271106 Replacement Plastic Plunger for Gauze Loading Rig L4071151
See page 2 for a complete listing of local offices and for ordering information. 53
thermal desorption
Thermal Desorber
kits and accessories
from PerkinElmer
Requires, but does not include, an options board, when added to the
entry-level thermal desorber. Installation by PerkinElmer Service is
required, but not included. For a full listing of thermal desorber
kits and supplies please visit us at:
Part No. www.perkinelmer.com/gcsupplies
M0413555
See page 2 for a complete listing of local offices and for ordering information. 55
Hydrogen and Air Gas Generators
Outlet Hydrocarbon Concentration < 0.1 ppm Outlet Dewpoint < -70 °C < -50 °C < -50 °C < -50 °C
Outlet Carbon Monoxide Concentration < 0.1 ppm Electrical 230/115 VAC 230/115 VAC 230/115 VAC 230/115 VAC
Outlet Particles < 0.5 Microns Removed 99.99% Requirements 270 W max 270 W max 270 W max 500 W max
Outlet Air Temperature Ambient +15 °C
Max Inlet Hydrocarbon Concentration 100 ppm Description Part No.
Maximum Outlet Pressure 6.5 bar
Max Inlet Carbon Monoxide Concentration 50 ppm 1.5 L/min of air (without compressor) N9307081
Max Inlet Temperature 40 °C 3.0 L/min of air (without compressor) N9307082
Inlet Pressure Range (regulated to 7 bar) 4.5–10 bar 6.0 L/min of air (without compressor) N9307083
Inlet Port 1/4" NPT 15.0 L/min of air (without compressor) N9307080
Outlet Port 1/8" NPT All models come WITHOUT a compressor.
Oil Free Compressor Required.
See page 2 for a complete listing of local offices and for ordering information. 57
Introducing EcoAnalytix from PerkinElmer
Why EcoAnalytix?
Because only PerkinElmer can best help our customers make a measurable difference.
Biofuels Development
EcoAnalytix solutions from PerkinElmer can help you achieve your business PerkinElmer knows that the right training, methods, applications,
and operations objectives, from the field through to processing, and from reporting and support are as integral to getting answers as the
fermentation to the final product, while ensuring the quality of biofuels and instrumentation. That’s why PerkinElmer has developed a novel
meeting regulatory requirements. Pre-defined analyzers and platforms support approach to meet the challenges that today’s labs face — that
both ASTM and EN methods. approach is called EcoAnalytixTM.
PerkinElmer’s Latest Biofuels Testing Analyzers include:
■ EcoAnalytix Biodiesel Glycerin and Methanol Analyzer - based on the Clarus
500 GC with an innovative dual-oven design and a TurboMatrix™ Headspace,
offering a unique solution to test for free/total glycerin and residual methanol
according to EN and ASTM standards
Environmental Analysis
EcoAnalytix analyzers and platforms for environmental analysis from PerkinElmer
provide methods, guidebooks and standard operating procedures where
necessary so that you can keep pace with regulatory change. We provide
industry leading environmental monitoring technology as well as renowned
expertise and advocacy that shape regulatory methods.
EcoAnalytix water quality platforms will provide specific analyzers and
methodologies to detect trace metal, organic, pesticide, chemical and radioactive
contaminants in water.
See page 2 for a complete listing of local offices and for ordering information. 59
PerkinElmer products —
proven quality, reliability
and results.
IR Temperature Gun!
Low-cost, non-contact temperature
measurement with laser sighting.
See page 36 for details.