0% found this document useful (0 votes)
59 views4 pages

85-0300 v1

The MFT1741+ is a multifunction tester designed for electrical installation testing and verification, suitable for low voltage building wiring and distribution. It features a wide range of test functions, including insulation testing, loop testing, and RCD tests, with safety features such as full input protection and audible warnings for hazardous voltages. The device is robust, with an IP54 rating, rechargeable batteries, and a user-friendly design optimized for various testing scenarios.

Uploaded by

Corneliu Braga
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
59 views4 pages

85-0300 v1

The MFT1741+ is a multifunction tester designed for electrical installation testing and verification, suitable for low voltage building wiring and distribution. It features a wide range of test functions, including insulation testing, loop testing, and RCD tests, with safety features such as full input protection and audible warnings for hazardous voltages. The device is robust, with an IP54 rating, rechargeable batteries, and a user-friendly design optimized for various testing scenarios.

Uploaded by

Corneliu Braga
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

MFT1741+

Multifunction Tester

APPLICATIONS: PRODUCT SELECTION CHART


The MFT1741+ offers a wide range of test functions, designed for all MFT1741+
electrical installation testing and verification of low voltage building
Insulation ranges
wiring and distribution testing scenarios. The MFT1741+ is IEC
100 V n
61010 CAT IV 300 V rated for safe connection anywhere within the
LV network on single and 3 phase systems. 250 V, 500 V n

1000 V n

Test voltage display n


The unique modern styling allows it to be operated while stood on
Adjustable buzzer threshold n
the floor, whilst up a ladder or platform, and optimised for hanging
Continuity and resistance ranges
around the user’s neck. Dual TEST and LOCK buttons - one pair at
each end - makes the testers easy to operate left or right handed. 200 mA test n

15 mA test n

GENERAL FEATURES: Adjustable buzzer threshold n

Loop testing
Quick to pick up and use, the function controls are colour coded to
2 and 3 wire non-tripping L-PE 50 V ~ 280 V n
make range selection easy and fast. They also reduce the chance of
using the wrong function or range. The large crystal clear backlit 2 wire Hi current L-N 50 V ~ 280 V n

display uses the Megger digital/analogue arc, providing indication 2 wire phase to phase L-L 50 V ~ 500 V n
of fluctuating readings while the dual digital readout shows precise PSCC and PFC (20 kA max.) n
values of key measurements simultaneously with the test parameters, Max. Zs display n
such as the output voltage on insulation testing as well as the
R1 + R2 value
resistance value in MΩ.
Touch voltage display on faulty earth n
Visible and audible safety warnings are paramount when testing high- Earth electrode test
energy systems and the MFT1741+ includes full input protection and
2 and 3 pole * n
safety warnings when a hazardous voltage is present. If live voltages
3 pole ART and Stakeless method * n
exist on a circuit during insulation or continuity testing, the voltage is
displayed on the screen. If this voltage exceeds a safe level, further RCD tests
testing is inhibited and a warning beep sounds. The MFT1741+ 1/2, 1, 5 x I and ramp RCD test n
features internally rechargeable batteries and charger with a charge Auto RCD test n
time of less than 4 hrs, so reducing the cost of ownership. Type AC, A and S RCDs n

The new MFT1741+ has been designed for tough environments and Type B (pure DC) RCDs n
ultimate reliability. Features include a rubber over mould for extra Programmable RCD n
protection and grip, IP54 protection against dust and water and an 3-phase RCD (no earth) n
EN61010 CAT IV safety rating. Its class leading input protection
10, 30, 100, 300 and 500 mA RCD n
ensures the MFT can withstand accidental misuse and voltage
Auto sequence for EV charge point RCDs* n
transients when other testers can’t. All this in an intuitive and easy
to use instrument with no hidden menus or complicated screens. Other features
Included with the instrument: standard 3-wire lead-set and a mains Supply measurement n
test lead, a switched probe for fast and easy testing, a full 12-month True RMS n
calibration certificate and warranty upgradeable to 3 years warranty, Leakage current measurement * n
free of charge. The MFT1741+ is supplied in a large soft pouch with
Phase rotation n
plenty of additional space for optional extras like a few tools and the
Calibration certificate n
earth electrode test kit, comprising 2 spikes and 3 long test leads.
Rechargeable batteries (charger included) n

SP5 Switched probe included n

Warranty upgradeable to 3 years FREE n

On board memory with Bluetooth download


®
n

CAT IV 300 V / CATIII 600 V n

Hard moulded case


Soft pouch with additional storage n

Confidence meter noise reduction n

New hardware loop test platform n

* requires optional accessory

2
MFT1741+
Multifunction Tester
SPECFICATIONS (Mode 1 + 2)

Insulation test Ramp test

Output voltage -0% +20% at rated load or less Touch voltage

Voltage display ±3% ±3 digits ±0.5% of rated voltage (0 ~ 253 V) +5% +15% ±0.5 V

Short circuit current 1.5 mA nominal test current Trip time ±1% ±1 ms

Test current on load 1 mA at min pass values of insulation Trip current ±5%

Insulation accuracy Step increments

1000 Volts 10 kΩ ~ 999 MΩ ±3% ±2 digits VAR (variable RCD selection)


500 Volts 10 kΩ ~ 500 MΩ ±3% ±2 digits 10 mA ~ 50 mA 1 mA steps
>500 MΩ ±10% ±4 digits 50 mA ~ 500 mA 5 mA steps
250 Volts 10 kΩ ~ 250 MΩ ±3% ±2 digits
500 mA ~ 1000 mA 10 mA steps
>250 MΩ ±10% ±4 digits
100 Volts 10 kΩ ~ 100 MΩ ±3% ±2 digits
>100 MΩ ±10% ±4 digits Supply measurement
Voltage 10 V ~ 600 V
(15 ~ 400 Hz) True RMS
Resistance and continuity
±3% ± 1 V ±2 digits
0.01 Ω ~ 99.9 Ω ±2% ±2 digits
Phase rotation indication
100 Ω ~ 99.9 kΩ ±5% ±2 digits
L1–L2–L3 and L1–L3–L2
Open circuit voltage 5 V ±1 V
Frequency 15 Hz ~ 99 Hz ±0.5% ±1 digit
Test current (0 Ω ~ 2 Ω)
100 Hz ~ 400 Hz ±2.0% ±2 digits
205 mA ±5 mA
Frequency resolution 0.1 Hz
15 mA ±5 mA
(user selectable)
Power supply

Loop test Batteries IEC LR6 type AA alkaline


(6 cells - supplied)
Live to earth/neutral supply
48 V ~ 280 V (45 Hz ~ 65 Hz) or 1.2 V NiMH
(rechargeable pack of 6 – supplied)
Live to live supply 48 V ~ 500 V (45 Hz ~ 65 Hz)
Mains charger for on-board re-charging (4 hours typical) 12 V car
L-N/L-L tests ±5% ±5 digits
charger (cigar lighter lead - optional)


L-E tests
Earth / ground test
0.1 Ω ~ 39.9 Ω ±5% ±5 digits ± noise margin
Resolution 0.01 Ω
40.0 Ω ~ 1000 Ω ±10% ±5 digits
Current 0.45 mA or 4.5 mA
Noise rejection 20 V pk/pk (7 V rms)
Display range 0.01 Ω ~ 1000 Ω
Max probe resistances Rp and Rc
Live to earth PFC range 20 kA
100 kΩ @ 50 V
Live to live PSCC range 20 kA 5 kΩ @ 25 V
2 and 3 pole method (0.01 Ω ~ 1.999 kΩ)

Reference conditions apply ±2.0% ±5 digits
For test environments see service data ART method (1.00 Ω ~ 1.999 kΩ)
±5.0% ±5 digits*
Stakeless method (1.00 Ω ~ 199 Ω)
RCD tests
±7.0% ±5 digits*
Supply up to 100 mA 48 V ~ 480 V (45 Hz ~ 65 Hz)
Supply up to 1 A 48 V ~ 280 V
Current
RCD type Type AC, A, S
(via optional clamp meter)
Type B (pure dc)
±5.0% ±3 digits.
No trip test (1/2xI) –10% ~ –0%
Range 0.1 mA to 200 A ac
Trip test (1xI, 2xI and 5xI) +0% ~ +10%
Resolution 0.1 mA
EV 30 mA ac, 6 mA dc (Mode 1 + 2)

3
MFT1741+
Multifunction Tester

mV sensor input
Including temperature (third party module)
±1.0% ±2 digits
Range 0.0 mV to ±199.9 mV dc
Resolution 0.1 mV

Data storage
Capacity: 1000 results
Bluetooth® communication

Safety IEC 61010-1:2010


IEC 61010-30:2010
IEC 61010-031:2008
600 V CAT III / 300 V CAT IV
(Max Phase to Phase 600 V)
IEC 61557:2007 parts 1 to 10
EMC IEC61326 edition 2 location class B ORDERING INFORMATION
Operating temperature range and humidity Description Order Code
-10 °C ~ +55 °C MFT1741+-BS 1012-611
90% R.H. at +40 °C max
Storage temperature range and humidity
Included accessories
-25 °C ~ +70 °C
Printed quick start guide
Maximum altitude 2000 m
Full user guide on CD
Weight (instrument and case) Calibration certificate
1 kg (with batteries, excluding case) Switched probe SP5 1002-774
Dimensions (instrument and case) Neck strap - Megger embroidered 2001-509
220 mm H x 390 mm W x 285 mm D 3 Wire lead set with prods and clips 1001-991
IP rating IP54 Mains plug test lead (BS1363) 6220-810
Calibration temperature AC battery charger 1002-736
+20 °C Large soft pouch with extra storage 1007-463
Temperature co-efficient
<0,1% per °CFor test environments Optional accessories
see service data. Fused 10 A test lead set (red/blue/green) with
prods and clips 1001-975
XTL30 Extension Test Lead 30 m 2007-998
The Bluetooth word mark and logo are owned by the Bluetooth
®

XTL50 Extension Test Lead 50 m 2207-997


SIG, Inc. and any use of such marks by Megger is under licence.
Cigar lighter adapter for battery charging. 6280-332
Switched Probe SP5 (silicone) 1001-687
MCC1010 Current measuring clamp 1010-516
MVC1010 Voltage inducing clamp, calibration 1010-518
check pcb (for stakeless test) and lead
Electrode kit 1001-810
Test and carry pouch 1006-408
3 Pole Earth Test Kit 6210-160
ETK30 (3 Pole Earth Test Kit) 1010-176

SALES OFFICE MFT1741+_DS_en_V01


Megger Limited www.megger.com
Archcliffe Road Dover ISO 9001
CT17 9EN England The word ‘Megger’ is a registered trademark
T +44 (0) 1304 502101
E UKsales@megger.com

You might also like