Development Permission - Plan
Development Permission - Plan
N
Inward Date INWARD_DATE Scale 1:100
VERSION NO.: 1.0.63
A AREA STATEMENT
VERSION DATE: 20/11/2024
1. Area of Land/Property/Record 11635.00
2. Deduction for Ext. Soc.
a. Proposed road cutting 94.60
b. Any reservation(Govet) 1135.00
c. Owners plot 0.00
3. Common Plot 1040.96
4. Net area of Building unit for planning 9364.44
44.33 5. Permissible built up unit for planning 50.00 52.60
6. Total permissible F.S.I. 1.80 210.38
7. Existing built up area
(1) Ground floor (3736.50 ) 41.97
(2) First floor
56 C 55 C-54 C-53 52 C 51 (3) Upper floor
TOTAL EXISTING BUILT UP AREA 41.97
8. Proposed Built up area
4.50
(i) Ground floor(Main structure)
Approved ExStructure-10
Approved ExStructure-9
Approved ExStructure-8
Approved ExStructure-7
Approved ExStructure-6
Approved ExStructure-5
5.71 4.50
(ii) Out house/Garrage
7.50
39 C 40 C-41 C-42 43 C 44 TOTAL PROPOSED BUILT UP AREA
9. GRAND TOTAL OF B.AREA AT G.F. 41.97
10. Proposed floor space area
Existing/ Approved Existing/ Approved
6.00 WIDE ROAD Proposed Built up Proposed F.S.I
BUArea F.S.I
12.40
12.40
Ground Floor 45.43 0.00 42.59 0.00
First Floor 45.43 0.00 42.36 0.00
E
Terrace Floor 3.07 0.00 0.00 0.00
Total Area: 93.93 0.00 84.95 0.00
LAY-OUT PLAN Total Proposed Floor Space Area 84.94
S
SCALE :- 1:500 11. Total existing floor space area 0.00
12. GRAND TOTAL OF F.S.I. AREA 84.94
W
13. F.S.I. CONSUMED 0.73
KEY PLAN Color Notes
TREE TREE TREE TREE TREE TREE TREE TREE TREE TREE TREE TREE
1.21
P.PIT COLOR INDEX
PLOT
2.87 PLOT LINES
EXISTING STREET
FUTURE STREET, IF ANY
22.58 16.00 PERMISSIBLE BUILDING LINE
26.30
26.30
OPEN SPACES
EXISTING WORKS
WORK PROPOSED TO BE DEMOLISHED
PROPOSED WORK
DRIANAGE AND SEWERAGE WORK
WATER SUPPLY WORK
WORK WITHOUT PERMISSION IF STARTED ON SITE
Approved ExStructure-1
Approved ExStructure-2
Approved ExStructure-3
Approved ExStructure-4
Approved ExStructure
APPROVED WORK
7.90
C (42)
BLDG HT: 6.90 MT. Layout Approved Perm FSI and Coverage Details
NO OF FLOORS: 2 AREA STATEMENT
FOR PERMISSIBLE B.A.
P/Y X NET AREA X 0.50
41.97/3736.50 X 9364.44 X 0.50
52.60 SQ.MT.
FOR PERMISSIBLE F.S.I.
22.58 16.00 P/Y X NET AREA X 1.80
5.75 41.97/3736.50 X 10405.40 X 1.80
210.38 SQ.MT.
F.S.I CONSUMED
1.80X84.94 / 105.19
0.73
6.00(ROAD)
6.00
6.00 MT.MAINROAD Tree Details (Table 3h)
Area : 265.95 Nos Of Trees
Plot Name
Reqd Prop
PLOT Tree 4 12
44.33(ROAD)
N
SITE PLAN
Note: For Proposal of Tenement from Approved Layout Plan, Proportionate Plot area will be considered for Scrutiny related calculations (e.g. Proportionate plot area, Margin FSI etc. only) which does not define actual Plot/Building Unit.
(Scale - 1:100)
Chandresh Chunara
003ERL31032500416
SUPERVISOR'S NAME & SIGNATURE DATE OF APPROVAL
APP_DATE
DESIGNATION OF APRROVER : DSG_APP
DIG_SIGN
QR CODE
BAR CODE
Grant of the
APP_CONDITION permission is subject to the conditions mentioned in the permission letter. Permission letter and approved Plan PDF can be downloaded by scanning the QR code.
ISO_A1_(841.00_x_594.00_MM) Based on the aforesaid permission the applicant reserves the rights to commence the construction from the day of issuance. Nevertheless; in case, for procuring the aforesaid permission, any document or system configuration for rules or information or parameters or drawings provided or attached is found to be incorrect or inconsistent with respect to prevailing bye-laws, by any authority or otherwise, the permission granted shall be considered as lapsed.Accuracy of Scrutiny Report and Drawing is subject to accuracy of end-user provided data, 3rd party
software/hardware/services, etc. SoftTech Engineers Ltd. is not liable for any damages which may arise from use, or inability to use the Application.Contents highlighted in magenta color are not verified.Texts printed in 'Italics' and 'Blue' color are user inputs, which are not verified and not generated by scrutiny software.
003BDP24253054
Application No. : APP_NO 003BP24252766
Development Permission No. : DP_NO
Project Title : REVI. G.F. PROP. F.F. & SECOND FLOOR PLAN FOR BLOCK NO.C-42 "SWASTIK HOUSING SOC. " R.S.NO.201, O.P.NP......, F.P.NO......, T.P.NO...., AT LLAGE : TARSALI, VADODARA. Inward No ODPS/2025/011658 Sheet 2/2
N
Inward Date INWARD_DATE Scale 1:100
CABIN
2.10
2.10
2.10
2.10
1.15
1.15
TERRACE FLOOR Floor Level +6.90 mt. TERRACE FLOOR Floor Level +6.90 mt.
Slab
Beam
0.11
0.11
0.50
0.50
3.00
3.00
FIRST FLOOR FIRST FLOOR
Beam
0.11
0.11
0.50
0.50
3.00
3.00
GROUND FLOOR GROUND FLOOR
0.90
0.90
G.L. PLINTH Floor Level +0.00 mt. G.L. PLINTH Floor Level +0.00 mt.
ELEVATION
SECTION SECTION
Sectional Diagram
W W 5.75
BATH BATH
V
2.14X1.05 2.14X1.05
0.79
V
D1 D1
SWHS
BED ROOM BED ROOM 2.07
WC V WC V
D1
D1
D
D
3.04X3.04 0.90X0.90 3.04X3.04 0.90X0.90
D
D
1.69 1.92 1.92
1.00
1.00
1.00
DN
DN
7.90
7.90
1.00
1.00
7.90
7.90
TERRACE
D
D
1.00
0.69 0.92 0.92
2.15
2.15
2.15
KITCHEN W KITCHEN W
LIVING
1.15
1.15
1.15
2.14x4.16 2.14x4.16
A UP
1.00 LIVING A' A UP
1.00 2.04X3.29 A' A
1.00
A'
0.11 0.11
2.04X3.29
W1 W1
VERANDAH VERANDAH
D
003ERL31032500416
SUPERVISOR'S NAME & SIGNATURE DATE OF APPROVAL
ISO_A2_(594.00_x_420.00_MM) Based on the aforesaid permission the applicant reserves the rights to commence the construction from the day of issuance. Nevertheless; in case, for procuring the aforesaid permission, any document or system configuration for rules or information or parameters or drawings provided or attached is found to be incorrect or inconsistent with respect to prevailing
bye-laws, by any authority or otherwise, the permission granted shall be considered as lapsed.Accuracy of Scrutiny Report and Drawing is subject to accuracy of end-user provided data, 3rd party software/hardware/services, etc. SoftTech Engineers Ltd. is not liable for any damages which may arise from use, or inability to use the Application.Contents
highlighted in magenta color are not verified.Texts printed in 'Italics' and 'Blue' color are user inputs, which are not verified and not generated by scrutiny software.