0% found this document useful (0 votes)
101 views40 pages

PVC Catalogue

Saudi Hepco LLC, established in 2002, specializes in manufacturing a wide range of uPVC pipes and fittings that are resistant to corrosion and suitable for various industrial applications. The company emphasizes high-quality standards and provides professional support to its customers in technical matters related to pipeline networks. Saudi Hepco aims to deliver quality products at competitive prices while ensuring compliance with international classification requirements.

Uploaded by

ctansari
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
101 views40 pages

PVC Catalogue

Saudi Hepco LLC, established in 2002, specializes in manufacturing a wide range of uPVC pipes and fittings that are resistant to corrosion and suitable for various industrial applications. The company emphasizes high-quality standards and provides professional support to its customers in technical matters related to pipeline networks. Saudi Hepco aims to deliver quality products at competitive prices while ensuring compliance with international classification requirements.

Uploaded by

ctansari
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 40

Saudi Hepco LLC

Into the New Age with


PVC

Technical &
PVC Pipes Product Guide
Content
Content
02 Introduction
03 About Us
04 Vision - Mission - Values
05 Plant
06 uPVC Duct Pipes
07-08 uPVC Sewer & Drain Pipes
09 uPVC Watermain
10 Dimension Of Saudi Hepco uPVC Pipes
11 -14 PVC Pipes ASTM Standards
15 Perforated uPVC Pipes
16 Customized Fittings (Watermain Assembled Fittings And Specials)
17 PVC Fabricated Products
18-19 PVC Conduit & Duct As Per Nema
20 PVC Utilities & Duct
21-31 Installation- Jointing, Handling And Quality Assurance
32 Associates and Customers
33 Summary of Experience (Major Projects)
34 Customer List
35-36 Certificates
‫‪Introduction‬‬
‫‪Introduction‬‬
‫‪Saudi Hepco LLC was established in 2002 to‬‬
‫اﻟــﻤﻘﺪﻣــﺔ‬
‫ﺗﻢ‬
‫ّ‬
‫اﻟﻤﻘﺪﻣــﺔ‬
‫ﻫﻴﺒــﻜــﻮ اﻟﺴـﻌﻮدﻳﺔ ﺷﺮﻛﺔ ذات ﻣﺴﺌﻮﻟﻴﺔ ﻣﺤﺪودة‬
‫‪manufacture a wide range of plastic pipes and‬‬
‫ﺗﺄﺳﻴﺴﻬــﺎ ﻓﻲ ﻋﺎم ‪ ٢٠٠٢‬م وذﻟﻚ ﻟﺘﺼﻨﻴﻊ ﻣﺠﻤﻮﻋﺔ واﺳﻌﺔ ﻣﻦ‬
‫‪pipe fittings.‬‬
‫اŽﻧﺎﺑﻴﺐ اﻟﺒﻼﺳﺘﻴﻜﻴﺔ واŽﻧﺎﺑﻴﺐ وﺗﺠﻬﻴﺰاﺗﻬــﺎ ‪.‬‬
‫‪Saudi Hepco’s uPVC pipes and fittings are‬‬
‫‪resistant to almost all types of corrosion,‬‬ ‫ّ‬
‫إن ﻣﻨﺘﺠﺎت ﺷﺮﻛﺔ ﻫﻴﺒــﻜــﻮ اﻟﺴـﻌﻮدﻳﺔ ﻣﻦ اŽﻧﺎﺑﻴﺐ وﺗﺠﻬﻴﺰاﺗﻬــﺎ‬
‫‪whether chemical or electro-chemical in nature.‬‬ ‫ﺗﺘﻤﻴﺰ ﺑﺄﻧﻬﺎ ﻣﻘﺎوﻣﺔ ﻟﺠﻤﻴﻊ أﻧـﻮاع اﻟﺘﺂﻛﻞ ﺳﻮاء أﻛﺎن ﻛﻴﻤﻴﺎﺋﻲ أو‬
‫‪Since uPVC is a non-conductor, galvanitic and‬‬ ‫اﻟﺘﻲ ﺑﻄﺒﻴﻌﺘﻬﺎ ﻛﻬﺮ وﻛﻴﻤﻴﺎﺋﻴﺔ ‪ .‬ﺣﻴﺚ أن أﻧﺎﺑﻴﺐ ﻋﺪﻳﺪ ﻛﻠﻮرﻳﺪ‬
‫‪electrochemical effects do not occur in uPVC‬‬
‫اﻟﻔﻴﻨﻴﻞ ﻋﺎزﻟﺔ ﻟﻠﻜﻬﺮﺑﺎء‪ ،‬ﻓﺈن ﺗﺄﺛﻴﺮات اﻟﺠﻠﻔﻨﺔ واﻟﻜﻬﺮوﻛﻴﻤﻴﺎء‬
‫‪pipe systems.‬‬
‫ﻻﺗﺤﺪث ﻓﻲ أﻧﻈﻤﺔ أﻧﺎﺑﻴﺐ ﻋﺪﻳﺪ ﻛﻠﻮرﻳﺪ اﻟﻔﻴﻨﻴﻞ‪.‬‬
‫‪Because it is non-metallic, the material is totally‬‬
‫‪resistant to all forms of metallic corrosion.‬‬ ‫وŽن ﻫﺬه اŽﻧﺎﺑﻴﺐ ﻏﻴﺮ ﻣﻌﺪﻧﻴﺔ ‪ ،‬ﻓﺈن اﻟﻤﻮاد ﻣﻘﺎوﻣﺔ ﺗﻤﺎﻣ‪ª‬‬
‫‪Aggressive waters resulting from both high‬‬ ‫ﻟﺠﻤﻴﻊ أﺷﻜﺎل اﻟﺘﺂﻛﻞ اﻟﻤﻌﺪﻧﻲ ‪ .‬وﻛﺬﻟﻚ اﻟﻤﻴﺎه اﻟﻤﺴﺒﺒﺔ ﻟﻠﺘﺂﻛﻞ‬
‫‪sulphate soils and low hardness waters will not‬‬ ‫اﻟﻨﺎﺗﺠﺔ ﻣﻦ اŽﺗﺮﺑﺔ اﻟﻐﻨﻴﺔ ﺑﺎﻟﻜﺒﺮﻳﺖ واﻟﻤﻴﺎه اﻟﻘﻠﻴﻠﻪ اﻟﻜﺎﻟﺴﻴﻮم‬
‫‪attack uPVC in any way.‬‬ ‫واﻟﺒﻮﺗﺎﺳﻴﻮم ﻟﻦ ﺗﺆﺛﺮ ﻋﻠﻰ ﻫﺬه اŽﻧﺎﺑﻴﺐ ﺑﺄي ﺣﺎل‪.‬‬

‫‪Saudi Hepco’s uPVC pipes and fittings can also‬‬ ‫وﻳﻤﻜﻦ أﻳﻀ‪ ª‬اﻋﺘﺒﺎر اŽﻧﺎﺑﻴﺐ واﻟﺘﺠﻬﻴﺰات اﻟﺘﻲ ﻳﺘﻢ ﺗﺼﻨﻴﻌﻬﺎ‬
‫‪be considered resistant to a wide range of‬‬
‫ﺑﻮاﺳﻄﺔ ﻫﻴﺒــﻜــﻮ اﻟﺴـﻌﻮدﻳﺔ ﻣﻘﺎوﻣﺔ ﻟﻤﺠﻤﻮﻋﺔ ﻛﺒﻴﺮة ﻣﻦ‬
‫‪industrial waters and chemicals and can offer‬‬
‫‪advantages in long term system life and‬‬ ‫اﻟﻤﻴﺎه واﻟﻤﻮاد اﻟﻜﻴﻤﻴﺎﺋﻴﺔ اﻟﺼﻨﺎﻋﻴﺔ ‪ ،‬وﻳﻤﻜﻦ أن ﺗﻮﻓﺮ ﻣﺰاﻳﺎ ﻋﻠﻰ‬
‫‪maintenance costs.‬‬ ‫اﻟﻤﺪى اﻟﻄﻮﻳﻞ ﻟﻨﻈﺎم اﻟﺤﻴﺎة وﺗﻜﺎﻟﻴﻒ اﻟﺼﻴﺎﻧﺔ‪.‬‬

‫‪Saudi Hepco water main Loc-Ring integral‬‬ ‫إن ﻧﻈﺎم ﺗﻮﺻﻴﻞ أﻧﺎﺑﻴﺐ ﻣﻴﺎه اﻟﺸﺮب اﻟﺬي ﺗﻢ ﺗﺼﻨﻴﻌﻪ ﺑﻮاﺳﻄﺔ‬
‫‪socket manufactured to the highest standards‬‬ ‫ﺷﺮﻛﺔ ﻫﻴﺒﻜﻮ اﻟﺴـﻌﻮدﻳﺔ ﻫﻮ ﻧﻈﺎم إﻏﻼق ﻣﺘﻜﺎﻣﻞ ﺗﻢ ﺗﺼﻨﻴﻌﻪ‬
‫‪incorporate a double compression seal which is‬‬
‫ﻟﻤﻄﺎﺑﻘﺔ أﻋﻠﻰ اﻟﻤﻌﺎﻳﻴﺮ وﻳﺤﺘﻮي ﻋﻠﻰ ﺳﺪاد ﻣﺤﻜﻢ ﺑﻀﻐﻂ‬
‫‪resistant to both positive and negative‬‬
‫ﻣﺰدوج ﻟﻤﻘﺎوﻣﺔ اﻟﻀﻐﻮﻃﺎت ا¾ﻳﺠﺎﺑﻴﺔ واﻟﺴﻠﺒﻴﺔ ‪.‬‬
‫‪pressures.‬‬

‫‪02‬‬
‫ﻣــﺎذا ﻋـــﻨﺎ ‪About Us‬‬
‫‪About Us‬‬ ‫ﻣــﺎذا ﻋـــﻨﺎ‬
‫‪SAUDI HEPCO is one of the leadings Company in‬‬ ‫إن ﺷﺮﻛﺔ ﻫﻴﺒﻜﻮ اﻟﺴﻌﻮدﻳﺔ ﻫﻲ ﺷﺮﻛﺔ راﺋﺪة ﻓﻲ ﻣﺠﺎل ﺗﺼﻨﻴﻊ‬
‫‪Kingdom of Saudi Arabia to start manufacturing‬‬ ‫أﻧﺎﺑﻴﺐ ا ﻟﻴﺎف اﻟﺰﺟﺎﺟﻴﺔ اﻟﻤﻘﻮاة ﺑﺎﻟﺒﻮﻟﻴﺴﺘﺮ وﺗﻮﺻﻴﻼﺗﻬﺎ ﻓﻲ‬
‫‪of PVC / uPVC Pipes and Fittings.‬‬ ‫اﻟﻤﻤﻠﻜﺔ اﻟﻌﺮﺑﻴﺔ اﻟﺴﻌﻮدﻳﺔ‪.‬‬

‫‪HEPCO has a professional management team and‬‬ ‫ﻫﻴﺒﻜــﻮ ﻟﺪﻳﻬﺎ ﻓﺮﻳﻖ ﻋﻤــﻞ إداري وﻣﻬﻨﻲ ﻣﻦ ذوي اﻟﺨﺒﺮة‬
‫‪an‬‬ ‫‪experienced‬‬ ‫‪and‬‬ ‫‪competent‬‬ ‫‪workforce.‬‬ ‫اﻟﻜﺒﻴﺮة واﻻﺧﺘﺼﺎص ‪ .‬ﺣﻴﺚ أن اﻟﻤﻨﺎﻓﺴﺔ اﻟﺸﺪﻳﺪة ﻓﻲ ﻣﺠﺎل‬
‫‪Competition is intense in pipe business demanding‬‬ ‫ا ﻋﻤﺎل اﻟﺘﺠﺎرﻳﺔ اﻟﺘﻲ ﺗﺘﻌﻠﻖ ﺑﺎ ﻧﺎﺑﻴﺐ ﺗﺘﻄﻠﺐ ﻣﻌﺎﻳﻴﺮ ﻋﺎﻟﻴﺔ ‪،‬‬
‫‪high standards, thus we apply stringent quality‬‬ ‫وﻧﺘﻴﺠﺔ ﻟﺬﻟﻚ ﻓﻘﺪ ﻗﻤﻨﺎ ﺑﺘﻄﺒﻴﻖ ﺑﺮاﻣﺞ ذات ﺗﻘﻨﻴﺔ ﻋﺎﻟﻴﺔ ﻓﻲ‬
‫‪control programs to ensure that all our pipes meet‬‬ ‫ﻣﺠﺎل ﻣﺮاﻗﺒﺔ وﺿﻤﺎن اﻟﺠﻮدة وﻟﻜﻲ ﻧﺘﺄﻛﺪ ﻣﻦ أن ﺟﻤﻴﻊ ا ﻧﺎﺑﻴﺐ‬
‫‪Saudi and International classification requirements,‬‬ ‫اﻟﺘﻲ ﻧﻘﻮم ﺑﺘﺼﻨﻴﻌﻬﺎ ﺗﻘﺎﺑﻞ ﻣﻌﺎﻳﻴﺮ ﻣﺘﻄﻠﺒﺎت اﻟﺘﺼﻨﻴﻒ اﻟﺪوﻟــﻲ ‪،‬‬
‫‪and are fit for the purpose.‬‬ ‫وﺗﻜﻮن ﻣﻨﺎﺳﺒﺔ ﻟﻬﺬا اﻟﻐـﺮض ‪.‬‬

‫‪HEPCO’s policy is to provide quality pipes and‬‬ ‫ّ‬


‫إن ﺳﻴﺎﺳﺔ ﺷﺮﻛﺘﻨﺎ ﻫﻮ ﺗﺼﻨﻴﻊ وﺗﻘﺪﻳﻢ أﻧﺎﺑﻴﺐ ذات ﺟﻮدة ﻋﺎﻟﻴﺔ‬
‫‪associated pipeline products at time and at‬‬ ‫وﻛﺬﻟﻚ اﻟﻤﻨﺘﺠﺎت اﻟﻤﺮﺗﺒﻄﺔ ﺑﺎ ﻧﺎﺑﻴﺐ ﻓﻲ اﻟﻮﻗﺖ اﻟﻤﻄﻠﻮب‬
‫‪competitive prices. At the same time, the HEPCO‬‬ ‫وﺑﺄﺳﻌــﺎر ﺗﻨﺎﻓﺴﻴــﺔ‪ .‬وﻓﻲ ﻧﻔﺲ اﻟﻮﻗﺖ‪ ،‬ﺗﺘﻌﻬﺪ اﻟﺸﺮﻛﺔ ﺑﺘﻮﻓﻴــﺮ‬
‫‪undertakes to provide professional support to its‬‬ ‫اﻟﺪﻋـﻢ اﻟﻔﻨﻲ ﻟﻌﻤﻼﺋﻬﺎ ﻓﻲ ﺟﻤﻴﻊ اﻟﻤﺴﺎﺋﻞ اﻟﻔﻨﻴﺔ واﻟﺘﻘﻨﻴﺔ‬
‫‪customers on all technical and other matters‬‬ ‫وﻛﺬﻟﻚ اﻟﺪﻋﻢ ا´ﺧـﺮ اﻟﻤﺘﻌﻠﻖ ﺑﺸﺒﻜﺎت ﺧﻄﻮط ا ﻧﺎﺑﻴﺐ‪،‬‬
‫‪relating to pipelines and networks, including‬‬ ‫وﻳﺸﻤﻞ ذﻟﻚ ﻣﻴﺎه اﻟﺸﺮب واﻟﺼﺮف اﻟﺼﺤﻲ واﻟﻐﺎز واﻟﺼﻨﺎﻋﺎت‬
‫‪potable water, sewage, gas, industrial and‬‬ ‫اﻟﺒﺘﺮوﻛﻴﻤﺎوﻳﺔ ‪.‬‬
‫‪petrochemical.‬‬

‫‪03‬‬
Vision
Vision
To manufacture quality products and provide
‫اﻟــــــﺮؤﻳــــﺔ‬
‫اﻟـــﺮؤﻳــﺔ‬
excellent service at all times. We will earn our ّ
‫إن رؤﻳﺘﻨﺎ ﻫﻲ ﺗﺼﻨﻴﻊ ﻣﻨﺘﺠﺎت ذات ﺟﻮدة ﻋﺎﻟﻴﺔ وﺗﻮﻓﻴﺮ ﺧﺪﻣﺔ‬
customer’s loyalty through continuous ‫ وﻧﺤﻦ ﺳﻮف ﻧﻌﻤﻞ ﻋﻠﻰ ﻛﺴﺐ وﻻء‬.‫ﻣﻤﺘﺎزة ﻓﻲ ﺟﻤﻴﻊ اŒوﻗﺎت‬
improvement driven by innovation. ‫اﻟﻌﻤﻼء ﻟﺪﻳﻨﺎ ﻣﻦ ﺧﻼل اﻟﺘﻄﻮﻳﺮ واﻟﺘﺤﺴﻴﻨﺎت اﻟﻤﺴﺘﻤﺮة واﻟﺘﻲ‬

A great place to work where people are inspired .‫ﻳﻘﻮدﻫﺎ اﻻﺑﺘﻜﺎر‬


to be the best.
. ‫إﻧﻪ ﻣﻜﺎن ﻋﻈﻴﻢ ﻟﺘﻘﺪﻳﻢ أﻓﻀﻞ ﻣﺎ ﻳﺮﺿﻲ ﺗﻄﻠﻌﺎت وآﻣﺎل اﻟﻨﺎس‬

Mission
Mission
To be the leading manufacturer in and out of the
‫اﻟــــﻤـﻬﻤــﺔ‬
‫اﻟﻤـﻬﻤﺔ‬
Kingdom while innovating to meet or surpass ‫اﻟﻤﻬﻤﺔ ﻫﻲ أن ﻧﻜﻮن ﺿﻤﻦ اﻟﻤﺼﺎﻧﻊ اﻟﺮاﺋﺪة واﻟﻘﻴﺎدﻳﺔ ﻟﻠﺘﺼﻨﻴﻊ‬
specifications and standards. ‫داﺧﻞ وﺧﺎرج اﻟﻤﻤﻠﻜﺔ اﻟﻌﺮﺑﻴﺔ اﻟﺴﻌﻮدﻳﺔ اﻟﺘﻲ ﺗﻘﻮم ﺑﺘﺼﻨﻴﻊ‬
. ‫ﻣﻨﺘﺠﺎت ﻣﻄﺎﺑﻘﺔ ﻟﻠﻤﻘﺎﻳﻴﺲ واﻟﻤﻮاﺻﻔﺎت اﻟﻌﺎﻟﻤﻴﺔ‬
Our goal is to provide superior value products
while our employees and business partners will
ّ
‫إن ﻫﺪﻓﻨﺎ ﻫﻮ ﺗﻮﻓﻴﺮ ﻣﻨﺘﺠﺎت ذات ﻗﻴﻤﺔ ﻋﺎﻟﻴﺔ ﻓﻲ ﺣﻴﻦ أن‬
share in our success and our shareholders will
receive a sustained better return on their ‫ﻣﻮﻇﻔﻴﻨﺎ وﺷﺮﻛﺎﺋﻨﺎ ﻓﻲ اŒﻋﻤﺎل ﻳﺸﺎرﻛﻮﻧﻨﺎ وﻳﺴﺎﻫﻤﻮن ﻓﻲ‬
investment. . ‫ﻧﺠﺎﺣﻨﺎ وﺑﺎﻟﺘﺎﻟﻲ ﺳﻮف ﺗﺘﻠﻘﻰ ﻋﺎﺋﺪا أﻓﻀﻞ ﻋﻠﻰ اﻻﺳﺘﺜﻤــﺎر‬

Values
Values
Excellent customer service
‫اﻟـــﻘـﻴــــــﻢ‬
‫اﻟﻘﻴﻢ‬
‫ﺧﺪﻣﺔ اﻟﻌﻤﻼء ﺑﺼﻮرة ﻣﻤﺘﺎزة‬
Superiority in performance
‫اﻟﺘﻔﻮق ﻓﻲ اŒداء‬
Harmonious relationship with the team
‫اﻟﻌﻼﻗﺔ ﻣﺘﻨﺎﻏﻤﺔ واﻧﺴﺠﺎم ﻣﻊ ﻓﺮﻳﻖ اﻟﻌﻤﻞ‬
Innovation in products and technology
‫اﻻﺑﺘﻜﺎر ﻓﻲ اﻟﻤﻨﺘﺠﺎت واﻟﺘﻜﻨﻮﻟﻮﺟﻴﺎ‬
Perfection in doing the “right” thing
."‫اﻟﻜﻤﺎل ﻓﻲ اﻟﻘﻴﺎم "اﻟﺸﻲء اﻟﺼﺤﻴﺢ‬
Respect for all people
. ‫اﺣﺘﺮام ﺟﻤﻴﻊ اﻟﻨﺎس‬

04
‫‪Plant‬‬
‫‪Plant‬‬
‫‪Our plant is located in the Western Region of‬‬
‫اﻟﻤﺼﻨـــﻊ‬
‫اﻟﻤﺼﻨـــﻊ‬
‫ﻟﺪﻳﻨﺎ ﻣﺼﻨﻊ ﻳﻘﻊ ﻓﻲ اﻟﻤﻨﻄﻘﺔ اﻟﻐﺮﺑﻴﺔ ﻣﻦ اﻟﻤﻤﻠﻜﺔ اﻟﻌﺮﺑﻴﺔ‬
‫‪Saudi Arabia at Yanbu Light Industrial Park Area,‬‬ ‫اﻟﺴﻌﻮدﻳﺔ ﻓﻲ ﻣﺪﻳﻨﺔ ﻳﻨﺒﻊ ﻣﻨﻄﻘﺔ اﻟﺼﻨﺎﻋﺎت اﻟﺨﻔﻴﻔﺔ ‪ ،‬اﻟﻬﻴﺌﺔ‬
‫‪Royal Commission Yanbu, which was established‬‬ ‫ﺗﻢ ﺗﺄﺳﻴﺴﻪ ﻓﻲ ﻋﺎم ‪ ٢٠٠٢‬م وذﻟﻚ‬‫اﻟﻤﻠﻜﻴﺔ ﻟﻠﺠﺒﻴﻞ وﻳﻨﺒﻊ ‪ ،‬واﻟﺬي ّ‬
‫‪in 2002 to manufacture:‬‬ ‫ﻟﺘﺼﻨﻴﻊ ﻣﺎ ﻳﻠﻲ ‪:‬‬

‫‪• uPVC Pipes and Fittings‬‬ ‫• أﻧﺎﺑﻴﺐ ﻋﺪﻳﺪ ﻛﻠﻮرﻳﺪ اﻟﻔﻴﻨﻴﻞ وﺗﻮﺻﻴﻼﺗﻬﺎ‪.‬‬
‫‪• GRP Pipes and Fittings‬‬ ‫• أﻧﺎﺑﻴﺐ ا€ﻟﻴﺎف اﻟﺰﺟﺎﺟﻴﺔ اﻟﻤﻘﻮاة ﺑﺎﻟﺒﻮﻟﻴﺴﺘﺮ وﺗﻮﺻﻴﻼﺗﻬﺎ‪.‬‬

‫‪• FRP Customized Products‬‬ ‫• ﻣﻨﺘﺠﺎت ﺑﺘﺼﻤﻴﻢ ﺧﺎص ﻣﻦ اﻟﻔﻴﺒﺮﺟﻼس‪.‬‬

‫‪Our plant’s area is 40,000 square meters, and has‬‬ ‫ﻣﺴﺎﺣﺔ اﻟﻤﺼﻨﻊ ‪ ٤٠٫٠٠٠‬ﻣﺘﺮ ﻣﺮﺑﻊ ‪ ،‬وﻣﺰوﱠ د ﺑﺄﻛﺜﺮ اﻟﻤﻜﺎﺋﻦ وا“ﻻت‬
‫‪the most advanced machineries and‬‬ ‫واﻟﺘﻘﻨﻴﺎت اﻟﺤﺪﻳﺜﺔ ﺑﺈﺷﺮاف ﻣﻬﻨﺪﺳﻴﻦ أﻛﻔﺎء ﻓﻲ ﻫﺬا اﻟﻤﺠﺎل ‪،‬‬
‫‪technologies with highly qualified engineers,‬‬ ‫وﻛﺬﻟﻚ ﻓﻨﻴﻲ ﻋﻠﻰ درﺟﺔ ﻋﺎﻟﻴﺔ ﻣﻦ اﻟﻜﻔﺎءة وذﻟﻚ ﻟﻤﻘﺎﺑﻠﺔ‬
‫‪technicians and operators to meet customer’s‬‬
‫ﻣﺘﻄﻠﺒﺎت اﻟﻌﻤﻼء وﺗﻮﻗﻌﺎﺗﻬـــﻢ ‪.‬‬
‫‪demands and expectations.‬‬
‫وﻋﻠﻰ أﺳﺎس ﺳﻨﻮي ‪ ،‬ﻧﻘﻮم ﺑﺘﺼﻨﻴﻊ وﺗﻮرﻳﺪ ﻣﺎ ﻳﺰﻳﺪ ﻋﻦ ‪ ٥٫٠٠٠‬ﻃﻦ‬
‫‪In a yearly basis, we manufacture and supply over‬‬
‫‪5,000 tons of Glass Reinforced Plastic (GRP), 100‬‬ ‫ﻣﻦ ا¶ﻟﻴﺎف اﻟﺰﺟﺎﺟﻴﺔ اﻟﻤﻘﻮاة ﺑﺎﻟﺒﻮﻟﻴﺴﺘﺮ ﺑﺎﻻﺿﺎﻓﺔ إﻟﻰ ‪ ١٠٠‬ﻃﻦ ﻣﻦ‬
‫‪tons of Fiber Reinforced Plastic (FRP), and 5,000‬‬ ‫ﻣﻨﺘﺠﺎت اﻟﻔﻴﺒﺮﺟﻼس و ‪ ٥٫٠٠٠‬ﻃﻦ ﻣﻦ اﻟﺒﻮﻟﻲ ﻓﻴﻨﻴﻞ ﻛﻠﻮراﻳﺪ‬
‫‪tons of Polyvinyl Chloride (PVC) in and out of the‬‬ ‫ﻟﻼﺳﺘﻌﻤﺎل داﺧﻞ وﺧﺎرج اﻟﻤﻤﻠﻜﺔ اﻟﻌﺮﺑﻴﺔ اﻟﺴﻌﻮدﻳﺔ ‪.‬‬
‫‪Kingdom.‬‬

‫‪05‬‬
uPVC DUCT PIPES
Manufactured to Saudi Standard
SAS 254 / 255

Dimensions in Millimeters
Nominal OutsideDiameter d1 Minimum
Sizeof Inside
Conduit Dimension Tolerance % Diameter
20 20 +0.0 / -0.3 14.1
Specifications: 25 25 +0.0 / -0.4 18.4
Standard Lengths : 6m with socket (non-
32 32 +0.0 / -0.4 24.4
standard lengths or
diameters to special 40 40 +0.0 / -0.4 31.2
order)
50 50 +0.0 / -0.5 39.7
Standard Colour : Dark Grey or to 63 63 +0.0 / -0.5 49.6
customer
specification
Properties:
Specific Gravity : 1.42
Bends : Long and short radius
Vicat Softening Point : 82 °C (BS 2782)
22.5°, 45 °, 90 °
Inflammability : Will not support combustion
Specific Heat : 1.00 Kj / Kg / °C
Cluster Bends : To customer
Thermal Conductivity: 1.9 x 10-3 W / (mk)
requirements
Tensile Strength : 46.5 Nmm-2 (6750 PSI) at 20 °C
Impact Strength : 4.75 – 6.10 Joules (3.5 – 4.5 ft lb)
Junctions : Square and swept
Compressive Strength: 65.50 Nmm-2 (9500 PSI)
tees, crosses and
Flexural Strength : 93.08 Nmm-2 (13500 PSI)
fittings, double
sockets, bellmouths,
end caps, clayware Applications:
adapters • Telephone Cables
• High, Medium & Low Voltage Underground Power
Jointing : Spigot and socket– Cables
dry fit or solvent • Street and Housing Power Supplies
cement for situations • Piped T.V. and Radio
demanding sealed • Factory and Industrial Applications
joints • Sheathing of Water and Gas Services

06
uPVC SEWER & DRAIN PIPES
Manufactured to Saudi Standard
SAS 1395 / 1396

Wall Thickness (mm)


Nominal Nominal Outside
Size Diameter (mm) Class 2 Class 3 Class4
(mm)
mm Tolerance Min. Tol. Min. Tol. Min. Tol.
110 110 +0.3 2.2 +0.5 3.2 +0.6 5.3 +0.8
160 160 +0.4 3.2 0.6 4.7 +0.7 7.7 +1.0
200 200 +4.0 4.0 +0.6 5.9 +0.8 9.6 +1.2
250 250 +0.5 4.9 +0.7 7.3 +1.0 11.9 +1.4
315 315 +0.6 6.2 +0.9 9.2 +1.2 15.0 +1.7
400 400 +0.7 7.9 +1.0 11.7 +1.4 19.1 +2.2
500 500 +0.9 9.8 +1.2 14.6 +1.7 23.9 +2.6
630 630 +1.1 12.4 +1.5 18.4 +2.1 30 +3.2
710 710 +1.2 14.0 +1.6 20.7 +2.3 - -

Specifications:
Pipes are normally available and supplied with SpecificGravity : 1.42
integral joints in 6m or 9m lengths, but lengths of Flammability : Will not support
3m can be produced if required. The metric Sewer Combustion
Drain system is terracotta coloured. Imperial pipe to SpecificHeat : 1.00 kJ/kg/°C
BS 3505 / BS 3506 is grey. Thermal Conductivity : 0.180 J/m²/s/°C/m
For the Colebrook White Formula the following Coefficient of Linear : 0.06 mm/m/°C
coefficients of friction shouldbe used: Expansion
Vicat SofteningPoint : 79°C
• 0.003mm when new
(5kg)
• 0.6mm when mature (the normal accepted value
Impact Strength : Complies with BS
for mature sewers)
5481/4660/3505
Note: Whilst it is difficult to claim the use of the Modulus of Elasticity : 3000 MN/m² at
lower value for a mature uPVC sewer, it 20°C
should be noted that because of the long Poisson’s Ratio : 1: 3
lengths and precision joints, it is difficult to Tensile Strength : In excess of
induce roughness by misalignment of joints. 45MN/m² at 20°C
Steppingdoes not occur. Elongationat Break : In excess of 80%

07
uPVC SEWER & DRAIN PIPES
Manufactured to Saudi Standard
SAS 1395 / 1396

Application Effect of Chemicals


To provide an efficient means of drainage of uPVC is resistant to most acids, alkalis and oils
waste water and foul discharge from but liable to attack by concentrated sulphuric,
appliances in single and multi-storey nitric and chromic acids and organic solvents.
buildings. For specialized applications, consult the
Technical Services Departmentfor advice.
Maintenance
Designers should provide adequate access for Effect of Solar Radiation:
periodic cleaning. Access pipes and bosses Prolonged exposure to sunlight will cause the
are available with the range. colour to fade. It may also result in slight loss
of impact strength. We would not expect this
Reactionwith other Materials to seriously affect the performance of the
uPVC has not been found to react adversely system.
with any traditional buildingmaterials.
Thermal Movement
Flammability Coefficient of linear expansion 0.5 x 10-4/°C
uPVC is self-extinguishing a defined by BS temperature rise, i.e. 1mm per 2m length for
2782; method508A. a temperature rise of 10°C. An allowance is
made for expansion of pipes and pipe fittings
in each socket.

08
uPVC WATERMAIN
Pressure Pipes and Fittings

Description Abrasion Resistance and Tuberculation


Manufactured to DIN 8061 / 8062 & SAS 14/15, the Abrasion of uPVC pipes can generally be ignored in
uPVC Watermain System is available in Metric sizes potable water systems. uPVC pipe is not subject to
within the range of 20 to 315 in both Classes 4 and 5. the effects of tuberculation as soluble encrustants
For Ease of identification, Metric size Watermain such as calcium carbonate do not precipitate on to
pipes are colored blue (or as per customer’s request) the walls of uPVC pipes.
and are suppliedin standard 6m lengths..
Chemical Resistance
Flow Characteristics Both uPVC and EPDM have goodresistance to a wide
The flow characteristics of uPVC Watermain can be range of chemicals. However, if the pipeline is to be
assessed using the Colebrook White Formula. The laid through contaminated ground, detailed
recommended value for the roughness coefficient guidance can be obtained from the Technical
(ks) for use with this formula is 0.003mm. AdvisoryService.

Jointing System
uPVC Watermain uses the integral Loc-Ring joint.
This simple and effective push-fit
compression joint assures quality jointing even in
difficult site conditions.

Formed Bends– Available in 90°, 45°, 22.5° and 11.25°

Working Pressure Nominal Diameter(mm)


Description
/ Class 50 75 110 140 160 200 250 315

Loc Ring Socket 6 Bar


10 Bar

16 Bar

Solvent Weld 10 Bar


Socket
16 Bar

Plain End 6 Bar

10 Bar
16 Bar

Legends: Available from stock Available to order

PVC Fittings
Nom. Nom.
Dia. a=R 90° 45° 22.5° 11.25°
Dia. a =R 90° 45° 22.5° 11.25°
mm Z mm Z mm Z mm Z mm mm Z mm Z mm Z mm Z mm
(mm) (mm)

50 229 457 318 257 216 160 686 953 546 406 343

75 343 572 368 292 267 200 914 1219 775 559 521

110 457 586 406 305 279 250 1143 1473 889 648 597

140 572 813 470 381 305 315 1372 1994 1105 913 635 09
DIMENSION OF SAUDI HEPCO uPVC PIPES
According to SAS 14 / 1998
Equivalent to DIN 8062 and 8061
Saudi Hepco offer a range of uPVC water main pipes in
metric sizes designed to meet the requirements of water
construction & industry.

Class 1 Class 2 Class 3 Class 4 Class 5


Nominal 2 Bar 4 Bar 6 Bar 10 Bar 16 Bar
Outside
No. No. No. No. No.
Diameter Nom. Nom. Nom. Nom. Nom.
Thick Thick Thick Thick Thick
(mm) Wt. Wt. Wt. Wt. Wt.
of wall of wall of wall of wall of wall
kg/m kg/m kg/m kg/m kg/m
mm mm mm mm mm

10 0.045 1.0
12 0.056 1.0
16 0.090 1.2
20 0.137 1.5
25 0.174 1.5 0.212 1.9
32 0.264 1.8 0.342 2.4
40 0.334 1.8 0.350 1.9 0.525 3.0
50 0.422 1.8 0.552 2.4 0.809 3.7
63 0.562 1.9 0.854 3.0 1.289 4.7
75 0.642 1.8 0.782 2.2 1.22 3.6 1.82 5.8
90 0.774 1.8 1.13 2.7 1.75 4.3 2.61 6.7
110 0.950 1.8 1.16 2.2 1.64 3.2 2.61 5.3 3.90 8.2
125 1.08 1.8 1.48 2.5 2.13 3.7 3.34 6.0 5.01 9.8
140 1.21 1.8 1.84 2.8 2.65 4.1 4.18 6.7 6.27 10.4
160 1.39 1.8 2.41 3.2 3.44 4.7 5.47 7.7 8.17 11.9
180 1.57 1.8 3.02 3.6 4.37 5.3 6.88 8.7 10.4 13.4
200 1.74 1.8 3.70 4.0 5.37 5.9 8.51 9.6 12.8 14.9
225 1.96 1.8 4.70 4.5 6.76 6.6 10.8 10.8 16.1 16.7
250 2.40 2.0 5.65 4.9 8.31 7.3 13.2 11.9 19.9 18.6
280 3.11 2.3 7.11 5.5 10.4 8.2 16.6 13.4 24.9 20.8
315 3.78 2.5 9.02 6.2 13.8 9.2 20.9 15.0 31.5 23.4
355 4.87 2.9 11.4 7.0 16.7 10.4 26.5 16.9 39.9 26.3
400 6.10 3.2 14.5 7.9 21.1 11.7 33.7 19.1 50.8 29.7
10
PVC PIPES

ASTM STANDARDS

ASTM D 1785 SCH - 40


NOMINAL PRESSURE AT 23°C
OUTSIDE WALL AVERAGE
PIPE (SHORTTERM TESTS)
SR. NO. DIAMETER THICKNESS WEIGHT
DIAMETER
MIN (MM) MIN (MM) (KG)/MTR BAR PSI
INCH
1 ½” 21.24 2.77 0.248 41.38 600
2 ¾” 26.57 2.87 0.329 33.10 480
3 1” 33.27 3.38 0.483 31.03 450
4 1 ¼” 42.03 3.56 0.652 25.52 370
5 1 ½” 48.11 3.68 0.779 22.76 330
6 2” 60.17 3.91 1.040 19.31 280
7 2 ½” 72.84 5.16 1.650 20.69 300
8 3” 88.70 5.49 2.160 17.90 260
9 4” 114.07 6.02 3.070 15.17 220
10 6” 168.00 7.11 5.410 12.41 180
11 8” 218.70 8.17 8.143 11.03 160

Pipes are standardized at 6m length. Other lengths are available on request. Socket type:
standardized as solvent cement jointed (SCJ). Plain end available on request. Color: white, grey,
blue and black (Other colors offered on request).

11
PVC PIPES

ASTM STANDARDS

ASTM D 1785 SCH-80


NOMINAL PRESSURE AT 23°C
OUTSIDE WALL AVERAGE
PIPE (SHORTTERM TESTS)
SR. NO. DIAMETER THICKNESS WEIGHT
DIAMETER
MIN (MM) MIN (MM) (KG)/MTR BAR PSI
INCH
1 ½” 21.24 3.73 0.309 58.62 850
2 ¾” 26.57 3.91 0.418 47.59 690
3 1” 33.27 4.55 0.614 43.45 630
4 1 ¼” 42.03 4.85 0.850 35.86 520
5 1 ½” 48.11 5.08 1.030 32.41 470
6 2” 60.17 5.54 1.430 27.59 400
7 2 ½” 72.84 7.01 2.180 28.97 420
8 3” 88.70 7.62 2.910 25.52 370
9 4” 114.07 8.56 4.360 22.07 320
10 6” 168.00 10.97 8.130 19.31 280
11 8” 218.70 12.70 12.400 17.24 250

Pipes are standardized at 6m length. Other lengths are available on request. Socket type: sizes 2 ½” and above
are available with solvent cement joints (SCJ type). All sizes are available with plain ends. Color: white, grey,
blue and black (Other colors offered on request).

ASTM D 1785 SCH-120


NOMINAL PRESSURE AT 23°C
OUTSIDE WALL AVERAGE
PIPE (SHORTTERM TESTS)
SR. NO. DIAMETER THICKNESS WEIGHT
DIAMETER
MIN (MM) MIN (MM) (KG)/MTR BAR PSI
INCH
1 ½” 21.34 4.32 0.35 69.66 1010
2 ¾” 26.67 4.32 0.46 53.1 770
3 1” 33.40 5.08 0.69 49.66 720
4 1 ¼” 42.16 5.46 0.97 41.38 600
5 1 ½” 48.25 5.72 1.17 37.24 540
6 2” 60.33 6.35 1.66 32.41 470
7 2 ½” 73.03 7.62 2.41 32.41 470
8 3” 88.90 8.89 3.44 30.39 440
9 4” 114.30 11.1 5.53 29.66 430
10 6” 168.28 14.27 10.63 25.52 370
12
11 8” 219.08 18.24 16.8 26.21 380
PVC PIPES

ASTM STANDARDS

ASTM D 2241 SDR


NOMINAL PRESSURE AT 23°C
OUTSIDE WALL AVERAGE
PIPE (SHORTTERM TESTS)
SR. NO. DIAMETER THICKNESS WEIGHT
DIAMETER
MIN (MM) MIN (MM) (KG)/MTR BAR PSI
INCH
1 ½” SDR 13.5 21.24 1.57 0.193 21.7 315
2 ¾” SDR 21.0 26.57 1.52 0.238 13.8 200
3 ¾” SDR 17.0 26.57 1.57 0.245 17.2 250
4 ¾” SDR 13.5 26.57 1.98 0.900 21.7 315
5 1” SDR 26.0 33.27 1.52 0.292 11.0 160
6 1” SDR 21.0 33.27 1.60 0.320 13.8 200
7 1” SDR 17.0 33.27 1.96 0.360 17.2 250
8 1” SDR 13.5 33.27 2.46 0.428 21.7 315
9 1 ¼” SDR 32.5 42.03 1.52 0.357 8.6 125
10 1 ¼” SDR 26.0 42.03 1.63 0.366 11.0 160
11 1 ¼” SDR 21.0 42.03 2.01 0.451 13.8 200
12 1 ¼” SDR 17.0 42.03 2.49 0.543 17.2 250
13 1 ¼” SDR 13.5 42.03 3.12 0.764 21.7 315
14 1 ½” SDR 32.5 48.11 1.52 0.407 8.6 125
15 1 ½” SDR 26.0 48.11 1.85 0.325 1.0 160
16 1 ½” SDR 21.0 48.11 2.29 0.520 13.8 200
17 1 ½” SDR 17.0 48.11 2.84 0.697 17.2 250
18 1 ½” SDR 13.5 48.11 3.58 0.860 21.7 315
19 2” SDR 32.5 60.17 1.85 0.490 8.6 125
20 2” SDR 26.0 60.17 2.31 0.680 11.0 160
21 2” SDR 21.0 60.17 2.87 0.876 13.8 200
22 2” SDR 17.0 60.17 3.56 1.070 17.2 250
23 2” SDR 13.5 60.17 4.47 1.313 21.7 315
24 3” SDR 41.0 88.70 2.16 0.678 6.9 100
25 3” SDR 32.5 88.70 2.74 1.130 8.6 125
26 3” SDR 26.0 88.70 3.43 1.506 11.0 160
27 3” SDR 21.0 88.70 4.24 1.836 13.8 200

13
PVC PIPES

ASTM STANDARDS

ASTM D 2241 SDR


NOMINAL OUTSIDE WALL AVERAGE PRESSURE AT 23°C
SR. NO. PIPESIZE DIAMETER THICKNESS WEIGHT (SHORTTERM TESTS)
INCH MIN (MM) MIN (MM) (KG)/MTR BAR PSI
28 3” SDR 17.0 88.70 5.23 2.233 17.2 250
29 3” SDR 13.5 88.70 6.58 2.780 21.7 315
30 4” SDR 41.0 114.07 2.80 1.250 6.9 100
31 4” SDR 32.5 114.07 3.51 1.850 8.6 125
32 4” SDR 26.0 114.07 4.39 2.430 11.0 160
33 4” SDR 21.0 114.07 5.44 2.790 13.8 200
34 4” SDR 17.0 114.07 6.73 3.790 17.2 250
35 4” SDR 13.5 114.07 8.46 4.678 21.7 315
36 6” SDR 41.0 168.00 4.11 3.355 6.9 100
37 6” SDR 32.5 168.00 5.18 3.990 8.6 125
38 6” SDR 26.0 168.00 6.48 4.970 11.0 160
39 6” SDR 21.0 168.00 8.03 6.550 13.8 200
40 6” SDR 17.0 168.00 9.91 7.855 17.2 250
41 6” SDR 13.5 168.00 12.47 9.418 21.7 315
42 8” SDR 41.0 218.70 5.33 5.505 6.9 100
43 8” SDR 32.5 218.70 6.73 6.895 8.6 125
44 8” SDR 26.0 218.70 8.43 8.705 11.0 160
45 8” SDR 21.0 218.70 10.41 11.000 13.8 200
46 8” SDR 17.0 218.70 12.90 12.800 17.2 250
The maximum pressure rating given above is based on water at 73°F / 23°C and for unthreaded
pipes. SDR-Standard Dimension Ratio = Outside Diameter / Wall Thickness (Note: wall thickness
maintained is minimumor more than required). Pipes are standardizedat 6m length(Other lengths
are available on request). Socket type: Standardized as solvent cement jointed (SCJ). Plain end
available on request. Color: white, grey, blue and black (Other colors offered on request).

14
PERFORATED

uPVC PIPES

Saudi Hepco perforated uPVC pipes are manufactured upon


request depending on the size and class of the pipes, below
figures given a general configuration which may vary for
each client’s requirements.
Straight Rows:

Staggered Rows:

Rangeof sizes : 75mm to 50mm


LongitudePitch of wholes (LP) : 30mm to 200mm
Hole Diameter : 5mm to 13 mm
Numberof Rows : 1 to 6
AngularPitch of Holes : 40, 80 or 120 degrees for 2 rows

SLOTTED PVC PIPES


Saudi Hepco slotted pipes are producedaccordingto RDA requirements and for use in loweringthe
undergroundwater table.

Straight Slots Staggered Slots


Slot Length : Dependto the size
Slot width : 1 / 1.1 / 1.5 / 2mm
Numberof Row : 4, 6 & 8 (but accordingto the size)
AngularPitch : To be recommendedby Saudi Hepco 15
CUSTOMIZED FITTINGS
Watermain Assembled
Fittings and Specials

Flanged Socket: Flanged Spigot:


Maximum
Nominal L2 Working
Maximum Size mm Pressure
Nominal L2 Working Bar
Size mm Pressure 2 305 12
Bar
2.5 305 12
2 305 12
3 305 12
3 305 12
4 305 12
4 305 12
5 305 12
5 305 12
6 305 12
6 305 12
8 458 9
8 458 9

16
PVC FABRICATED PRODUCTS
Saudi Hepco is manufacturing all kinds of long bend and repair coupling
fittings which are required in the project during installation. All these
fittings are combined with Saudi Hepco Pipe under Standards DIN
8062/8061 and it is available with single and double rubber joint at the end.
Also available for all kind of pressure rating 6-10 and 16 bar.

Repair Coupling: Register Coupling:

d mm E mm H mm d mm E mm H mm L mm Z mm
63 86 280 63 86 280 128 30
75 102 280 75 102 280 123 30
90 120 290 90 120 290 133 30
110 144 290 110 144 310 135 35
160 202 350 125 161 330 143 35
200 248 440 140 178 350 158 40
225 277 400 160 202 350 155 40
250 304 440 180 224 380 173 50
280 342 440 200 248 410 185 50
315 382 440 225 277 460 195 55
250 304 460 223 55
280 342 490 220 60
315 382 500 220 60

17
PVC CONDUIT & DUCT
AS PER NEMA TC 2 EPC 80-PVC
(ELECTRICAL USE)

NOMINAL OUTSIDE WALL PRESSURE


SR WEIGHT (SHORT TERM TESTS)
PIPE SIZE DIAMETER THICKNESS
NO (KG)/MTR
INCH MIN (MM) MIN (MM) BAR PSI
1 1/2" 21.24 2.770 0.248 41 600
2 3/4" 26.57 2.870 0.329 33 480
3 1” 33.27 3.380 0.483 31 450
4 11/4” 42.03 3.560 0.652 25 370
5 11/2” 48.11 3.680 0.779 23 330
6 2” 60.17 3.910 1.040 19 280
7 21/2” 72.84 5.160 1.650 18 260
8 3” 88.70 5.490 2.160 15 220
9 4” 114.07 6.020 3.070 12 180
10 6” 168.00 7.110 5.410 11 160
Pipes are standardized at 3, 5.8 & 6 m length. Socket type: standardized as solvent cement jointed (SCJ) for 2”
& above. All sizes available with plain ends. Color: white, grey, blue and black (Other colors offered on
request)

PVC Utilities Duct


As Per Nema TC 6 PVC Type EB-20 & Astm F 512
(Electrical Use)-encased Burial-to Be Encased In Concrete

NOMINAL OUTSIDE WALL PRESSURE


SR WEIGHT (SHORT TERM TESTS)
PIPE SIZE DIAMETER THICKNESS
NO (KG)/MTR
INCH MIN (MM) MIN (MM) BAR PSI
1 1/2" 21.24 1.520 0.155 16 232
2 3/4" 26.57 1.520 0.198 12 1174
3 1” 33.27 1.520 0.251 10 145
4 11/4” 42.03 1.780 0.365 8 116
5 11/2” 48.11 2.030 0.470 8 116
6 2” 60.17 2.540 0.719 8 116
7 21/2” 72.84 2.790 0.952 8 116
8 3” 88.70 3.180 1.310 6 87
9 4” 114.07 3.810 2.000 6 87

Pipes are standardized at 5.8 & 6 m length. Socket type: standardized as solvent cement jointed (scj) for 2” &
above. All sizes available with plain ends. Color: white, grey, blue and black (Other colors offered on request)
18
PVC CONDUIT & DUCT
AS PER NEMA TC 2 EPC 80-PVC
(ELECTRICAL USE)

NOMINAL OUTSIDE PRESSURE


SR THICKNESS (SHORT TERM TESTS) WEIGHT
PIPE SIZE DIAMETER
NO MIN (MM) (KG)/MTR
INCH MIN (MM) BAR PSI
1 1/2" 21.24 3.730 59 850 0.309
2 3/4" 26.57 3.910 48 690 0.418
3 1” 33.27 4.550 43 630 0.614
4 11/4” 42.03 4.850 36 520 0.850
5 11/2” 48.11 5.080 32 470 1.030
6 2” 60.17 5.540 28 400 1.430
7 21/2” 72.84 7.010 25 370 2.180
8 3” 88.70 7.620 22 320 2.910
9 4” 114.07 8.560 19 280 4.260
10 6” 168.00 10.970 17 250 8.130
Pipes are standardized at 3, 5.8 & 6 m length. Socket type: standardized as solvent cement jointed (SCJ) for
2” & above. All sizes available with plain ends. Color: white, grey, blue and black (Other colors offered on request)

PVC Utilities Duct


As Per Nema TC 6 PVC Type EB-20 & Astm F 512
(Electrical Use)-encased Burial-to Be Encased In Concrete
NOMINAL OUTSIDE WALL PRESSURE
SR WEIGHT
PIPE SIZE DIAMETER THICKNESS
NO BAR PSI (KG)/MTR
INCH MIN (MM) MIN (MM)
1 2” 60.17 1.520 4 58 0.465
2 3” 88.70 1.550 4 58 0.703
3 4” 114.07 2.080 4 58 1.170
4 6” 168.00 3.180 4 58 2.530
Pipes are standardized at 3, 5.8 & 6 m length. Socket type: standardized as solvent cement jointed (SCJ).
Plain end available on request. Color: white, grey, blue and black (Other colors offered on request)

19
PVC UTILITIES & DUCT
AS PER NEMA TC 6 PVC TYPE DB-60 &
ASTM F 512 (ELECTRICAL USE)
DIRECT BURIAL- FOR DIRECT BURIAL
UNDERGROUND

NOMINAL OUTSIDE PRESSURE


SR THICKNESS (LONGTERM TESTS) WEIGHT
PIPE SIZE DIAMETER
NO MIN (MM) (KG)/MTR
INCH MIN (MM) BAR PSI
1 2” 60.17 1.52 5 72.5 0.465
2 3” 88.70 2.34 5 72.5 1.000
3 4” 114.07 3.07 5 72.5 1.650
4 6” 168.00 4.62 5 72.5 3.570
Pipes are standardized at 5.8 & 6 m length. Socket type: standardized as solvent cement jointed (SCJ). Plain
end available on request. Color: white, grey, blue and black (Other colors offered on request)

PVC PIPES AS PER NEMA TC 8 PVC TYPE EB - 35 & ASTM F 512


(ELECTRICAL USE)ENCASED
- BURIAL- TO BE ENCASED IN CONCRETE
NOMINAL OUTSIDE WALL PRESSURE
SR WEIGHT
PIPE SIZE DIAMETER THICKNESS
NO BAR PSI (KG)/MTR
INCH MIN (MM) MIN (MM)
1 2” 60.17 1.52 5 72.5 0.465
2 3” 88.70 1.93 4 58.0 0.847
3 4” 114.07 2.54 4 58.0 1.390
4 6” 168.00 3.86 4 58.0 3.020
Pipes are standardized at 5.8 & 6 m length. Socket type: standardized as solvent cement jointed (SCJ). Plain
end available on request. Color: white, grey, blue and black (Other colors offered on request)

PVC PIPES AS PER NEMA TC 8 PVC TYPE DB - 120 & ASTM F 512

NOMINAL OUTSIDE WALL PRESSURE


SR (LONGTERM TESTS) WEIGHT
PIPE SIZE DIAMETER THICKNESS
NO (KG)/MTR
INCH MIN (MM) MIN (MM) BAR PSI
1 1” 33.270 1.520 10 145 0.251
2 11/2” 48.110 1.520 8 116 0.369
3 2” 60.170 1.960 8 116 0.576
4 3” 88.700 3.000 8 116 1.250
5 4” 114.070 3.910 8 116 2.050
6 6” 168.000 5.770 8 116 4.420
Pipes are standardized at 5.8 & 6 m length. Socket type: standardized as solvent cement jointed (scj) for 2”
& above. All sizes available with plain ends. Color: white, grey, blue and black (Other colors offered on
request)
20
INSTALLATION,
JOINTING, HANDLING and
QUALITY ASSURANCE

Introduction We conduct a series of tests to ensure water


Saudi Hepco offer a range of uPVC Watermain quality is not affected by the pipe and that
imperial pressure pipes designed to meet the guidelines from the World Health Organization
requirements of the Water Industry. are adhered to.
Qualities such as lightness, ease of transport,
simplicity of jointing, speed of laying and cost Fracture Toughness Test
effective installation have enabled uPVC pipe The resistance of a plastic pipe to developing
systems to make a dynamic contribution to cracks and bursting is one of the major
water engineering around the world. considerations when selecting pipeline
materials. uPVC is a very strong material, but has
Description been characterized by brittle behavior in certain
Manufactured to ASTM D 1785, the uPVC circumstances. The theory of Fracture Toughness
Watermain System is available in imperial sizes is used to ensure that uPVC pipes are not
within the range 3/8” in both Schedules 40 and 80. susceptible to failure brought about through
brittle behavior. uPVC pipes made by
For ease of identification imperial size manufacturers that have not adopted this theory
Watermain pipes are colored dark grey and are are unlikely to provide adequate service life. Only
supplied in standard 6m lengths. uPVC pipes tested for resistance to crack growth
can be sure to have a measureable resistance to
Pipes can be supplied plain ended but the failure resulting from flaws and defects arising
normal joint for the size range 2” to 12” is the during manufacture, and damage caused during
Loc-Ring joint and pipes in the size range 3/8” to the normal installation operations.
12” can be supplied with solvent weld sockets.
For size range 2” to 24” formed bends are
available at 90°, 45°, 22.5° and 11.25°, with joints
matching pipe joints.

Specification
uPVC Watermain pipes are manufactured in
accordance with ASTM D 1785 specification for
uPVC pressure pipes for cold potable water and
industrial uses.

The Loc-Ring joints include EPDM sealing rings


in accordance with BS 2494: 1991 specification
for elastomeric joint sealing rings for pipework
and pipelines, type W.

Material Testing
Testing required by ASTM D 1785 includes both
burst tests and impact tests. In addition some
tests are also repeated at elevated temperatures.
21
INSTALLATION,
JOINTING, HANDLING and
QUALITY ASSURANCE

The fracture toughness test is based on the the BSI register of firms of assessed capability
application of fracture mechanics to the and hold certificates of registration FM 31040 to
behavior of plastic pipes. It provides a means of BS EN ISO 9002.
initially examining the pipe structure for
consistency and testing the performance of a Changes in Direction
section whilst it is being subjected to a It is recommended that, wherever possible,
combination of stress and defect – such as changes of direction should be accommodated
would be the case in a typical site installation. using purpose made bends.

C Ring Test Pipes up to 6” may be cold bent in situ to


To evaluate performance under long term minimum radius of a curvature of 200 pipe
loading, rings are cut from Watermain pipe and diameters. Further details are available from the
notches are machined on to the surface. These Technical Advisory Service.
rings are then loaded for many hours in
bending. Flow characteristics
The flow characteristics of uPVC Watermain can
It is not usual to encounter pipes which are be assessed using Colebrook White formula. The
subjected to point loading, bending or damage recommended value for the roughness
whilst undergoing pressure or cyclic loading. coefficient (ks) for use with this formula is
0.003mm.
Quality Assurance
Saudi Hepco have an unparalleled commitment Abrasion Resistance and Tuberculation
to quality through the innovation of new Abrasion of uPVC pipes can generally be
products. All products are manufactured under ignored in potable water systems. uPVC pipe is
the approval of BS EN ISO 9002 of the British not subject to the effects of tuberculation as
Standards Institutions. soluble encrustants such as calcium carbonate
do not precipitate on to the walls of uPVC pipes.
The uPVC Watermain range is manufactured at
the Yanbu site in Saudi Arabia which is listed in Chemical Resistance
Both uPVC and EPDM have good resistance to a
wide range of chemicals. However, if the
pipeline is to be laid through contaminated
ground, detailed guidance can be obtained
from the Technical Advisory Service.

External Compressive Loads


Soil and Traffic Loads
Under normal operating conditions it is not
necessary to confirm the performance of a uPVC
pressure pipe for resistance to soil and traffic
loadings.
22
INSTALLATION,
JOINTING, HANDLING and
QUALITY ASSURANCE

In these conditions the stress resulting from the Allowance should be made to accommodate
internal pressure greatly outweighs the soil and the thrust forces developed which would
traffic load stresses. otherwise cause deflection, extension or joint
separation in the pipeline.
However, in certain circumstances where mains It is most important that the thrust forces are
are expected to stand empty for long periods of calculated using the maximum internal pressure
time, engineers may wish to confirm the to which the pipeline is likely to be subjected.
structural capabilities of the pipe system under
soil and traffic load conditions. Please consult Pipe Support
the Technical Advisory Service for further In non-buried situations the need arises to
information. provide pipe supports to ensure that the weight
of the pipe and its contents are adequately
Thrust Restraint supported. Recommended maximum support
A uPVC pipeline operating under internal spacing for the Watermain range at operating
pressure will generate thrust forces at any temperatures 20°C to 60°C are available from
change of direction, reduction in diameter, the Technical Advisory Service.
blank end or closed valve.

23
INSTALLATION,
JOINTING, HANDLING and
QUALITY ASSURANCE

Expansion and Contraction takes place. Single pipes should be offloaded


In common with a number of engineering individually. A 10” pipe can be carried by two
materials uPVC will expand and/or contract men in normal site conditions (subject to HSC
under the influence of variations in pipe and regulations for manual handling of loads).
ambient temperatures. The Coefficient of
Thermal Expansion/Contraction of uPVC pipes Pipes should be free from sharp projections.
which is equal to 6.0 x 10-5 per °C is relatively Stacks of individual pipes should not exceed 7
high compared with other materials. Due layers or 1.5m high and 3.0, wide.
account should be taken of possible contraction
of expansion when installing uPVC pipes which Strong ultraviolet light can discolor the pipes,
will be subject to variations in temperature and for prolonged storage outdoors a
either immediately following installation or in protective opaque cover should be used.
their service lifetime. Discoloration has a minimal effect on the
mechanical performance of uPVC, however if
there is any doubt please contact the Technical
Advisory Service.

Jointing System
uPVC Watermain uses the integral Loc-Ring
joint. This simple and effective push-fit
compression joint assures quality jointing even
in difficult site conditions.

Sitework (Handling)
uPVC Watermain pipes are lightweight and easy
to handle. In order to avoid damage to the pipes
on site, good site practice should be followed.
Pipes should not be dropped onto hard surfaces
or dragged along the ground as this can result
in scoring. Under no circumstances should
metallic slings be used in direct contact with the
pipe wall. Nylon webbing or other similar
material should be used.

Standard bundles of packs of 6m lengths can be


handled using a forklift truck or a crane. The
packs should remain intact until pipe laying

24
INSTALLATION,
JOINTING, HANDLING and
QUALITY ASSURANCE

Jointing
a- The spigot and socket to be joined should be
carefully examined for any damage which
would impair the jointing procedure. Particular
attention should be paid to the spigot chamfer
and the sealing ring. The pipe should be
chamfered to a depth of half the wall thickness
and at an inclination angle of 15° to the pipe
axis. If pipes are cut on site they should be cut
square to the pipe axis with a fine toothed saw
and chamfered to half the pipe wall thickness
with a coarse file or surform tool. The
chamfered spigot should be clean and free
from swarf and burrs. The sealing ring should
be correctly seated in the socket groove,
complete with the insert ring the sealing
portion of the ring must be free from damage
of any sort. Joints containing damaged or
incorrectly fitted rings but not be used.

b- The spigot insertion depth should be


measured as the depth from the mouth to
the shoulder of the socket. Pipes are supplied
with the spigot insertion depth marked on
the spigot end. The spigots of cut pipes
should be marked similarly using an indelible
crayon. In an allowance for expansion is
required (e.g. where changes in operating
temperatures are anticipated), this should be
deducted from the spigot insertion depth.

25
INSTALLATION,
JOINTING, HANDLING and
QUALITY ASSURANCE

c- The spigot and socket should be thoroughly


cleaned. All grease, dirt, swarf and other
foreign matter should be removed from the
sealing areas.

d- The spigot end and triple seal portion of the


sealing ring should be thoroughly lubricated
with the pipe supplied free-of-charge.

The spigot should be lubricated to the full


insertion depth and around its complete
circumference, paying particular attention to
the chamfer area. The triple seal should be
lubricated around its complete
circumference. The guiding principle should
be to apply a liberal quantity of lubricant and
avoid ‘dry’ areas on the sealing surfaces.

e- Immediately after lubrication, the spigot


should be brought into contact with the
socket. The spigot pipe and parent joint
should be accurately aligned so that the axis
of the pipes are precisely in line. The spigot
should be and fed into the socket until
resistance from the inner sealing section is
felt. Correct alignment at this stage is
essential to ensure that the rubber sealing
ring is not pinched or torn.

f- The joint can now be completed by one of


the methods described below.

26
INSTALLATION,
JOINTING, HANDLING and
QUALITY ASSURANCE

i- Leverage Method mark coincides with the mouth of the socket


Sizes up to 8” can normally be jointed by being jointed. No further pulling should take
applying leverage with a crow bar at the place. The camps incorporate protective pads to
following socket end. A stout timber should prevent gouging and scratching of the piTpe
be inserted between the crow bar and the surface. The clamps must not be used without
pipe socket to prevent damage to the latter. the protective pads.
The leverage should be applied in a steady,
continuous manner until the spigot insertion Watermain Solvent Weld Socket
depth mark coincides with the mouth of the 1- The spigot and socket to be jointed should
socket being jointed. No further leverage be carefully examined for any damage which
should be applied. If any undue resistance is ii- would impair the jointing procedure.
felt and the spigot cannot be disassembled Particular attention should be paid to the
and examined to determine possible causes spigot chamfer as for Loc-Ring jointing
(e.g. lack of lubrication and pinched or procedure.
trapped sealing ring). The procedure should
then be repeated as described previously. 2- The spigot insertion depth should be
measure as the depth from the mouth to the
ii- Jointing Clamps shoulder of the socket (see below). The
These are available for sizes above 8” and are insertion depth should then be marked on
specially designed for use with Watermain the spigot using an indelible crayon.
uPVC Pressure Pipes. These are particularly
useful where bends are to be installed in the 3- The mating areas of the spigot and socket
pipeline. The clamps should be positioned so should be thoroughly cleaned using the
that one clamp is adjacent to the socket Watermain Cleaning Fluid provided and a
shoulder and the other close to, but not clean rag or absorbent paper.
overlapping the depth insertion mark. N.B. Man-made fibers must not be used to
clean joints which are to be solvent welded.
Once assembled with the steel tie wires in place,
a simple ratchet action will draw the spigot into 4- Lightly roughen the mating surfaces of the
the socket mouth. The spigot should be spigot and socket, using clean emery cloth or
correctly aligned as described above the drawn medium glass paper.
into the socket until the spigot insertion depth

27
INSTALLATION,
JOINTING, HANDLING and
QUALITY ASSURANCE

5- Thoroughly clean again the mating surfaces 7- Immediately following cement application
using the Watermain Cleaning Fluid ensure that the parent pipe is suitably
provided and a clean rag or absorbent paper. anchored, and push the spigot fully home in
Ensure that all mating surfaces are clean and the socket without turning the pipe. The
completely dry. spigot should be inserted with a steady,
continuous motion and held in place for 20
seconds. Remove the surplus cement from
around the mouth of the socket.

6- Using a brush of the size recommended (see


table) apply an even layer of Watermain
Solvent Cement to the spigot and socket
mating surfaces. The cement should be 8- Leave the joint undisturbed for five minutes,
applied in a lengthways direction and NOT then handle with reasonable care.
with a circular motion. For joints of nominal
diameter 3 and above, the cement should be
applied simultaneously to the spigot and
socket by two people.

28
INSTALLATION,
JOINTING, HANDLING and
QUALITY ASSURANCE

IMPORTANT
SOLVENT WELD NOTES
1- Solvent cement is flammable. Do not work near a naked flame or smoke in the work area.
2- Solvent cement should be used in well ventilated conditions.
3- The instructions on the tin, especially those relating to first aid should be strictly adhered to.
4- On no account must cleaning fluid be mixed with solvent cement.
5- The solvent in the cement evaporates quickly, so the tin should be closed immediately after use.
6- Do not use a brush on solvent cement which has previously hardened.
7- Solvent cement spilled on the pipe surface should be removed immediately.
8- If solvent cement is spilled in the trench on the backfill material, the contaminated material must be
removed from the working area.

Nominal Joints from Type & Size (inches) Number of


Diameter 500ml Tin of Brush Persons
3/8 160 3/16 Round 1
½ 140 3/16 Round 1
¾ 110 3/8 Round 1
1 75 3/8 Round 1
1¼ 55 1 Flat 1
1½ 48 1 Flat 1
2 33 2 Flat 1
2½ 22 2 Flat 1
3 18 2 Flat 2
4 10 2 Flat 2
5 5 2 Flat 2
6 3 2 Flat 2
7 2 2 Flat 2
>7Please consult our Technical Department

29
INSTALLATION,
JOINTING, HANDLING and
QUALITY ASSURANCE

Trench Work soil, with no boulders, bricks or rocks which


The line and level of the pipe and buried depth might cause point-loading on the pipe. When
of the pipeline, will have been predetermined at laying the pipe directly, the trench formation
the design stage. should be trimmed to an even finish which will
provide continuous support to the pipe.
The trench should not be excavated too far in
advance of pipe laying and should be backfilled Additional excavation will be required at the
as soon as possible, however, joints should be position of the pipe sockets to ensure proper
left exposed until testing has been successfully joint assembly and pipe support.
completed.
Pipe Laying on Bedding
The width of the trench at ground level will If the formation is unsuitable for direct laying,
depend on the type of subsoil and buried depth the trench will need to be excavated to a
of the pipeline. The minimum width of the further depth of a minimum of 100mm below
trench at the pipe springing line should be as the underside of the pipe.
narrow as practicable but not less than the pipe
diameter plus 300mm. The maximum width of This should be made up with a suitable
the trench at the crown of the pipe must not bedding material. In extreme conditions such
exceed the pipe diameter plus 600mm. as waterlogged or unstable ground it may be
necessary to increase the thickness of the
Trench Information bedding material.
Direct Laying
If the pipe is to be laid directly onto the trench Pipelines laid through rock should always be
bottom make sure that the trench formation is laid on a minimum of 100mm bed of suitable
composed of : - stable, uniform, fine-grained bedding materials

30
INSTALLATION,
JOINTING, HANDLING and
QUALITY ASSURANCE

The bedding material should be placed


carefully in the trench and properly compacted
by hand to ensure a sound continuous bed for
the pipes.

Particular attention should be paid to the


socket holes to ensure the correct placement
and compaction of bedding material in this
area.

Bricks or other forms of temporary pipe


support should never be left in the trench.

Bedding Material
The bedding material selected may be available
from excavated trench material or may need to
be imported from another source. The material
should be granular in nature, free from large
stones or debris and preferably fine grained.
Materials such as clay or hard chalk which will
break up when wetted should not be used.
Suitable materials are free draining coarse sand
and nominal single size gravel with rounded or
angular particles. Gravels should be nominal
single size 10mm or 5mm to 10mm, which have
good self-compacting properties.

Safety
Starts here

31
ASSOCIATES AND CUSTOMERS

32
Summary of Experience
( Major Projects)

• Project A4 - Area of Bohairat, Zahid & Faiha in Makkah


• Step 1 of development of Industrials City in Sudair
• Amana `Madinah Al-Munawarah Project
• Site Development - Jubail 2, Stage 2
• Sabic Housing Yanbu
• Royal Commission University College Dormitories
• Royal Commission Nurses Housing Project
• Royal Commission - Construction of Primary and Secondary
• Roads and Utilities for Hail Al-Azizia and Hail Al-Jaar
• Royal Commission0 Hail Al - Fahd City Center
• Royal Commission General Utilities for RC Investment and other Sites
• Royal Commission Waterfront Development - MODA
• Royal Commission Construction Infrastructure at Hail Al-Nakheel 2 and 6 Oyoun 2
• Royal Commission Construction of Utilities Network and Development of Al-Bathana Area
• Royal Commission Yanbu Technical Institute
• Royal Commission Construction of 2 Boys School, 1 Girl Primary School and 1 Girls Secondary School
• Royal Commission - Minor Utility work and Conversation of Portable Water Irrigation to TSE to MYAS
• Royal Commission Construction and Site Development for the Waterfront - Phase 3 at Madinat
Yanbu Al-Sinayah
• Marafic STG Unit 5 & 6 Project HVAC & FF 0 In Heavy Industrial Area - Yanbu Al Sinaiyah
• Royal Commission Construction of Roads and Utilities in Expansion (LIPE) Area
• Royal Commission Yanbu Refinery - Tanks Farm Package, Yanby Al-Sinaiyah
• Royal Commission Yanbu University Men’s Housing Phase 1
• Royal Commission - Construction of 380KV Substation 10J & 5KV Satelite S/ST, Contract
• Luberef Saudi Oil Aramco Company, Yanbu
• Natpetk Yanbu
• Ministry of Water - Hassa Water O. & M. Project
• Saudi Electric Corporation Riyadh SCECO vendor no available
33
Customer List

• Al-Harbi Riyadh
• Civil Work Company, Alhasa
• Wanyah Establishment Riyadh
• DEEM Company Riyadh
• Al-Bilad Company Riyadh
• Abdullah-Lazmi Riyadh
• Saudi Oger Ltd Riyadh
• Alfanar Company Riyadh
• Energy Company Limited (TAACA)
• Amec Riyadh
• Al Muhaidib Jeddah
• Al Angari Riyadh
• SBG-KAFD Riyadh
• Mashariq Riyadh
• Bahra Cable Riyadh
• KAU Project both Riyadh/Jeddah
• UCEMS, an electromechanical company associated with Harmain
• Railway project Jeddah
• King Abdullah Financial District (KAFD), 30 parcels - Riyadh - CRP Water Tanks
• Al-Mailabi & Sons Co.
• Bejing Construction Engineering Group Fo. Ltd. KSA
• Peaks Construction & Maintenance Co. Ltd
• Arabtec Saudi Arabia Ltd
• Star Cole Est, Water & Environmental Engineering
• A.R. NAMLA Contracting Co. Ltd.
• JAWDAT Construction
• Sinohydro Corporation
• Project Build Company
• China Harbour Engineering Company Limited
• Qaisar Raza Yousaf construction Co.

34
• Luberef Saudi Oil Aramco Company, Yanbu
• Natped, Yanbu
Certificates

35
Certificates

36
Head Office & Factory »°ù«FôdG Öàµe
Saudi Hepco LLC ájOƒ©°ùdG ƒµÑ«g
P.O.Box 102 -Yanbu ™Ñæj 102 .Ü.¢U
6th Street, Light Industrial Zone áØ«ØÿG äÉYÉæ°üdG á≤£æe - ¢SOɰùdG ´QɰT
á«YÉæ°üdG ™Ñæj - ᫵∏ŸG áÄ«¡dG
Yanbu Al Sinaiyah -K S A
ájOƒ©°ùdG á«Hô©dG áµ∏ªŸG
Tel. +966 14 3211744 / 3211746 +966 14 3211744 / 3211746 ¿ƒØ∏J
3254881 / 3254882 3254882 / 3254881
Fax +966 14 3211742 +966 14 3211742 ¢ùcÉa

Riyadh Branch ¢VÉjôdG ´ôa


Saudi Hepco LLC ájOƒ©°ùdG ƒµÑ«g
P.O.Box 245802 245802 .Ü.¢U
Riyadh 11312 11312 ¢VÉjôdG
Kingdom of Saudi Arabia ájOƒ©°ùdG á«Hô©dG áµ∏ªŸG
Tel. +966 11 4153011 +966 11 2919409 ¿ƒØ∏J
Fax +966 11 4789881 +966 11 4789881 ¢ùcÉa

Jeddah Branch Ió÷G ´ôa


Saudi Hepco LLC ájOƒ©°ùdG ƒµÑ«g
P.O.Box 114918 114918 Ü.¢U
Jeddah 21831 21831 ¢VÉjôdG
Kingdom of Saudi Arabia ájOƒ©°ùdG á«Hô©dG áµ∏ªŸG
Tel. +966 12 6425834 +966 12 6425834 ¿ƒØ∏J
Fax +966 12 6426871 +966 12 6426871 ¢ùcÉa

Website: www.saudihepco.com.sa
E m a i l : info@saudihepco.com.sa