0% found this document useful (0 votes)
26 views3 pages

Aoms 4u

The document provides specifications for the AOMS-4U and AOMS-8U Analog Output Modules, which feature 4 or 8 independently programmable analog output channels for DC current and voltage. It highlights key features such as 14-bit resolution, MODBUS communication, and three-way isolation to prevent ground loops. The modules are designed for DIN-Rail mounting and operate within a wide voltage range, making them suitable for various industrial applications.

Uploaded by

Matthew Kuttikad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
26 views3 pages

Aoms 4u

The document provides specifications for the AOMS-4U and AOMS-8U Analog Output Modules, which feature 4 or 8 independently programmable analog output channels for DC current and voltage. It highlights key features such as 14-bit resolution, MODBUS communication, and three-way isolation to prevent ground loops. The modules are designed for DIN-Rail mounting and operate within a wide voltage range, making them suitable for various industrial applications.

Uploaded by

Matthew Kuttikad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Analog Output Module

Process Precision Instruments


AOMS-4U / AOMS-8U
Vasai Road (E), Dist. Palghar - 401210,
4 / 8 Channels
Maharashtra, India
DIN-Rail Mount
MODBUS over Serial www.ppiindia.net

AOMS-8U AOMS-4U Configuration Tool

CPU STS
CPU STS
COMM

COMM

OP STS
OP STS

AOMS AOMS

ISOLATION HI-SPEED 14 BIT COMPACT MODBUS SETUP PC TOOL DIN RAIL

Salient Features General Information

4 / 8 Channel DIN-Rail Analog Output Module


Ÿ 4 (AOMS-4U) or 8 (AOMS-8U) Analog Output Channels Product Type
MODBUS over RS485 Serial Interface
Ÿ Each Channel Independently Programmable for DC Current
AOMS-4U, 4 Channel Module
(0-20 mA, 4-20 mA & 0-10 mA) or Voltage (0-5 V, 1-5 V & 0- Ordering Code
AOMS-8U, 8 Channel Module
10 V) Output
Quantity 1 Unit
Ÿ 14 Bit Output Signal Resolution
Ÿ Programmable Min / Max Counts Corresponding to Signal Accessories (Optional) USB to RS485 Convertor
Low & Signal High Outputs Similar Modules AIMS-4X, AIMS-8X
Ÿ Programmable Fail-Safe Output Signal Level Against DIMS-8, DIMS-16
Communication Link Failure DOMS-12

Ÿ Three-way Isolation Eliminates Potential Ground Loops


between Power, Outputs and RS485 Serial Port
Ÿ Supports Coils (Bits) & Bit-Mapped Registers MODBUS Data
Type for Most Parameters
Ÿ 2-wire, Half-Duplex, Start-Stop Synchronized RS485 Serial
Port
Ÿ Industry Standard MODBUS RTU Protocol with Programmable
ID, Baud Rate & Parity
Ÿ Compact DIN-Rail Mount Enclosure : 22.5(W) X 101(H) X
119(D), mm
Ÿ Wide Supply Voltage Range : 18 ~ 32 VDC (24 VDC Nominal)
Ÿ Free PC Tool for Easy Configuration and Parameter Settings

PPI \ E Catalog 1
Analog Output Module
Channel Specifications

Number of Channels 4/8


Output Types DC mA : 0-20 mA, 4-20 mA, 0-10 mA
(Programmable) DC Volts : 0 to 5V, 1 to 5V, 0 to 10V

Accuracy Better than ± 0.1% of Span


Resolution Better than 14 Bit
Response Time 150 mS typical for output signal to reach 98% of final value
(Step Change) (Actual response time will change with load type / value)

Output Burden Current : 0-600 Ω typical Voltage : 1 KΩ Minimum


Isolation Three-way Isolation Eliminates Potential Ground Loops between Power, Outputs & RS485 Serial Port
1500VAC for 1 second or 250VAC continuous
Scaling Programmable Minimum & Maximum Counts (-30,000 to +30,000) Corresponding to Signal
(User Programmable) Low & Signal High Outputs

Fail-Safe Mode The Outputs hold programmed Signal Level upon Communication link failure for more than
programmed time period (1 to 300 Sec.)

Serial Communication

Port RS485, 2-wire, Half Duplex, Start-Stop Synchronized


Protocol MODBUS RTU
Baud Rate Settable : 2400, 4800, 9600, 19200, 38400
Parity Settable : None, Even, Odd
Max. Units per Loop 31
Max. Distance 1200 Meters

Power Supply

Type Switch Mode (SMPS)


Power Requirement 18 ~ 32 VDC, nominal 24 VDC @ 300mA Max.
Note : In case of looping multiple modules on one power source, make sure that the power
source is capable of supplying minimum 300mA current per module.

Consumption 7 VA Max @ 24 VDC

Physical

Mounting DIN-Rail
Overall Dimensions 22.5(W) X 101(H) X 119(D), mm
Terminals Screw Type, Pluggable
Weight 400 gm, Appx.

Environmental

Operating Ambient 0 to 55°C & 5 to 90%RH Non-condensing


Storage Temperature -10 to +70°C
Not Suitable for use in Corrosive or Explosive Atmospheres. The Panel in which the Instrument
Atmospheres
is Mounted must be free of Electrically Conductive Pollution.

PPI \ E Catalog 2
Analog Output Module
Terminations

4 Channel Module

34 35 36 37 30 31 32 33 26 27 28 29 22 23 24 25
- + - + - + - + - + - + - + - +
V mA V mA V mA V mA
AO-8 AO-7 AO-6 AO-5

Signal Connections
4 Channels

8 Channels

T1 T2 T3 T4

T1 T2 T3 T4
-
Analog Output

V
AO-X

- +
mA
+
Supply
AO-1 AO-2 AO-3 AO-4 RS485 18 ~ 32 VDC
mA V mA V mA V mA V
+ - + - + - + - + - + - + - + -
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

8 Channel Module

34 35 36 37 30 31 32 33 26 27 28 29 22 23 24 25
- + - + - + - + - + - + - + - +
V mA V mA V mA V mA
AO-8 AO-7 AO-6 AO-5
Signal Connections
4 Channels

8 Channels

T1 T2 T3 T4

T1 T2 T3 T4
-
Analog Output

V
AO-X

- +
mA
+

Supply
AO-1 AO-2 AO-3 AO-4 RS485 18 ~ 32 VDC
mA V mA V mA V mA V
+ - + - + - + - + - + - + - + -
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

ProcessPrecisionInstruments(AnISO9001:2008Company)
101,DiamondIndustrialEstate,Navghar,VasaiRoad(E),Dist.Palghar-401210,Maharashtra,India
Sales:8208199048/8208141446Support:07498799226/08767395333
sales@ppiindia.net www.ppiindia.net

Jul 2023

PPI \ E Catalog 3

You might also like