LHY Product Catalogue EN
LHY Product Catalogue EN
Product Catalogue.
Linde Hydraulics Media. INFORMATION
Information.
PRODUCT
CATALOGUE DATASHEETS BROCHURES FACT SHEETS CAD DOWNLOADS
General technical data. General technical data. General technical data. General technical data. 3D models in *.stp file.
Design characteristics & Design characteristics & Design characteristics & Design characteristics &
Product advantages. Product advantages. Product advantages. Product advantages.
Functional descriptions.
LEARN MORE
MEDIA & DOWNLOADS
www.lhy.com
CONTENT
Linde Hydraulics Product Catalogue.
Content.
Variable displacement.
PUMPS
Self-regulating.
Variable displacement.
HIGH
PRESSURE MOTORS
HYDRAULICS
Fixed displacement.
Compact
Pump/Motor - Compact unit. unit
SYSTEMS
Shift in
Shift in Motion. Motion
LEARN MORE
MEDIA & DOWNLOADS
OUR SERVICES
Our Services.
Linde Hydraulics Lifecycle.
Even when our products are finally ready for series production, we do not lean For repair and remanufacturing services you can find a service partner
back or rest on the fact that we have a very competent and experienced team. close to you on our website at www.linde-hydraulics.com/network
With a holistic quality concept, we ensure consistently high quality and reliability -
completely independent of variance or quantity.
LEARN MORE
ONLINE SHOP
Electronics. ELECTRONICS
Controllers. iCon®.
Product advantages
Fields of application
iCon®
CB 16-02 CD 88-02 CD 97-02
Simple controls
Underspeed control
Compact
unit
Dual path drive
On-road drive
Shift in
Motion
Complex controls
General technical data
Controller Connector Outputs Inputs Comm.
Inductive sensors
Digital PullDown
Analog In, 0-5 V
24V at 1000 mA
LowSide current
10V at 250 mA
5 V at 150 mA
Digital PullUp
Ethernet 100
Frequency In
LowSide Out
HighSide Out
(frequency)
Safety level
60+94 pin
controller
Function
PWM In
Ignition
Family
Safety
Tyco
CAN
3A
TE
CB 16-02 PLb 0 2 0 4 2 1 8 2 0 0 0 1 1
CD 88-02 PLd 6 10 2 22 2 1 19 7 1 10 12 1 3
LEARN MORE
®
CD 97-02 PLd 19 8 8 8 2 2 24 14 4 4 12 1 4
ICON
ELECTRONICS
Electronics.
Diagnostics. iDiag®.
Design characteristics
Product advantages
Compact
unit
Shift in
HPV-02
Nominal size 55 75 105 135 165 210 280
Displacement Max. displacement cc/rev 54.7 75.9 105 135.7 165.6 210.1 281.9
Max. operating speed rpm 3900 3400 3200 3000 2750 2300 2400
Speed
Max. speed* rpm 4150 3600 3400 3200 2950 2500 2550
Nominal pressure bar 450 450 450 450 450 450 450
Pressure Max. pressure** bar 500 500 500 500 500 500 500
Compact
Max. housing pressure bar 2.5 2.5 2.5 2.5 2.5 2.5 2.5
unit Torque Torque ( p=430 bar; charge press.=20 bar) Nm 374 519 719 929 1133 1438 1929
Corner power (theor.) (Vmax x nmax x p 430 bar) kW 153 185 241 292 326 346 485
Shift in
Weight (approx.)*** (with H1-control, without oil) kg 46 49 66 72 113 132 164
Motion
Customer interfaces
Control options**** Sensors Flanges Shafts**** PTO Ports
Pressure cut-off
Enable function
Power take-off
Torque Control
holes (d=17,5mm)
Swash angle
Proportional
Radial twin
ISO 6149-1
ISO 6162-2
3-Position
Compagnion flange
threads M12
threads M16
4 additional
4 additional
Pressure
additional
2 hole,
2 hole,
2 hole
4 hole
ports
ISO 3019-1
(SAEJ 744)
DIN 5480
SAE-B
Work ports
Electro-hydraulic SAE-C
Hydraulic SAE-D
Threaded ports
LEARN MORE
Mechanic SAE-E
HPV-02
* highest transient speed, that can temporarily occur | ** highest transient pressure, that can temporarily occur | *** inclusive internal gear pump (size 55-135) or external gear pump (size 165-280) | **** Availability depends on nominal size
PUMPS
Open Circuit.
Self-Regulating Pump. HPR-02.
Legal emission regulations force manufacturers of mobile Design characteristics
machinery to optimize the noise emission of their products.
Since secondary measures tend to be expensive and less — Axial piston pump in swashplate design
efficient Linde Hydraulics prefers to fight the noise where — Exact controllers with and without position feedback
it is generated: by optimally connecting an additional — Adaptive noise optimization SPU
volume directly next to the commutation of the HPR-02 — Hydrostatic plain bearing of the swashplate
pump, Linde Hydraulics invented the SPU silencer. The
Product advantages
adaptive SPU reduces pressure pulsations in the regulating
pump over the entire range of operation – without loss of — Excellent suction up to rated speed
power. — High power density
— Energy saving operation by ‘flow on demand’-control
HPR-02
Nominal size 55 75 95 105 135 165 210 249 280 105 D 125 D 165 D 210 D 249 D
Displacement Max. displacement cc/rev 55 75.9 94.7 105 135.7 163.6 210.1 249.9 281.9 210 2x125 2x165 2x210 2x249
Speed Max. operating speed rpm 2700 2500 2500 2500 2350 2400 2100 23002 2000 2450 2400 2100 2100 2000
(without tank pressurization)
Volume flow Max. volume flow* l/min 148.5 189.8 237.5 246.8 312.1 392.6 441.2 574.82 563.8 514.5 600.0 695.5 882 1000
Nominal pressure bar 420 420 350 420 420 350 420 350 420 420 350 420 350 350
Pressure Max. pressure** bar 500 500 420 500 500 420 500 420 500 500 420 500 420 420 Compact
Max. housing pressure bar 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 unit
Torque Torque Nm 368 507 528 702 907 911 1404 1392 1884 1245 1392 1964 2339 2785
2
Corner power (theoretical) kW 104 132.8 138 172.7 218.5 229 308.8 335.3 394.7 319.4 337 431.8 514 583 Shift in
Weight (approx.) (without oil) kg 39 39 44.5 50 65 74 116 125 165 96 113 177 180 340 Motion
Customer interfaces
∆pLS – override
∆pLS – override
Speed sensor
power limiter
power limiter
stroke limiter
and pressure
and pressure
Swash angle
Compagnion
ANSI B92.1-
ISO 3019-1
SAE J 1946
(SAEJ 744)
hyperbolic
hyperbolic
DIN 5480
electrical
hydraulic
electric
cut-off
cut-off
flange
Typ A
1970
Load sensing
Electro-proportional LEARN MORE
2 HPR-02
* theoretical data of a single unit without efficiency effects | ** highest transient pressure, that can temporarily occur | **** Availability depends on nominal size | Consultation with Linde Hydraulics required
Open Circuit. CONTROL VALVES
LEARN MORE
MONOBLOCK
CONTROL VALVES
Open Circuit.
Modular Control Valves.
Manifold valve plates of series VT modular are made up of Design characteristics
individual components of a modular building block system.
This is why manifold valve plates can be configured to — Directional control valves available as sub plate
optimally match any application with one up to eight mounted valves
actuators. — Designed for the Linde Synchron Control (LSC) –
Load Sensing System
The directional control valves are at the core of every — Nominal sizes 25 and 30
manifold plate in LSC technology. Compared to other load — Flows up to 600 l/min (size30)
sensing directional control valves, LSC directional control — Modular design for the configuration of
valves stand apart, in particular, thanks to the integrated valve plates for 1-8 actuators
downstream pressure compensators and pressure copiers. — Optionally with hydraulic, electric or
This arrangement prevents the actuator from lowering combined piloting
when the function starts.
Product advantages
As a result of the compact design, the oil flow only needs
to pass through the valve once and not several times. — All advantages of the LSC valve technology
This ensures optimized flow passages in the directional — Easy to configure building block system
control valve. Due to the high-precision production of the — Adjustable to the target application
directional control valves, there is only minimal leakage — Quick availability
even at high load, which is beneficial to the load holding — Ideal for machines with low production volume
function of the valves.
Compact
unit
Shift in
Motion
LEARN MORE
VT MODULAR
Open & Closed Circuit. MOTORS
CMV
Nominal size 60 85 115 140 170 215
Displacement Max. displacement cc/rev 62 87.7 115.3 144.1 170 217.9
Max. operating speed at Vmax rpm 4450 3900 3550 3250 3100 2900
Max. speed at Vmax* rpm on request
Speed
Max. operating speed at Vmin rpm 7200 6800 6150 5600 4900 4600
Max. speed at Vmin* rpm on request
Compact
Nominal pressure bar 450 450 450 450 450 450
unit Pressure Max. pressure** bar 500 500 500 500 500 500
Max. housing pressure bar 2.5 2.5 2.5 2.5 2.5 2.5
Shift in
Torque Output torque ( p=430 bar and Vmax) Nm 411 582 787 958 1163 1471
Motion Corner power (theor.) (Vmax x nmax at Vmin x p 430 bar) kW 320 427 508 578 597 718
Weight approx. (without oil) kg 27.7 36.3 44.8 59.2 62.1 76.4
Customer interfaces
Compagnion flange
(negative control)
Pressure override
(positive control)
ISO 3019 – 2
ISO 3019 – 2
ISO 6149 – 1
Proportional
ISO 3019-1
ISO 3019-1
ISO 6162-2
ISO 6162-2
(SAEJ 744)
(SAEJ 744)
2-Position
Side ports
DIN 5480
(metric)
Plug-in
Speed
Max. housing pressure bar 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Torque Output torque ( p=430 bar and Vmax) Nm 374 519 719 928 1133 1438 1929 1437 2267 Shift in
Corner power (theor.) (Vmax x nmax at Vmin x p 430 bar) kW 184 239 309 360 415 482 586 677 878 Motion
Customer interfaces
Control options Sensors Flanges Shafts**** Through drive Ports****
ISO 6149 – 1
Proportional
105D, 165D
2 hole
4 hole
ISO 3019-1
ISO 6162-2
ISO 6162-2
(SAEJ 744)
2-Position
DIN 5480
Speed
Radial
Axial
SAE C
Electro-hydraulic SAE D Work ports
Hydraulic SAE E Threaded ports LEARN MORE
HMV-02
* highest transient speed, that can temporarily occur | ** highest transient pressure, that can temporarily occur | **** Availability depends on nominal size
Open & Closed Circuit. MOTORS
HMV-02 D
Nominal size 105 D 165 D
Displacement Max. displacement cc/rev 210 331.2
Max. operating speed at Vmax rpm 3300 2900
Max. speed at Vmax* rpm 3400 3100
Speed
Max. operating speed at Vmin rpm 4100 3500
Max. speed at Vmin* rpm 4400 3700
Customer interfaces
Control options Sensors Flanges**** Shafts**** Through drive Ports****
Pressure side selection
Compagnion flange
Pressure override
Through drive
ISO 6149 – 1
Proportional
2 hole
4 hole
ISO 3019-1
ISO 6162-2
ISO 6162-2
(SAEJ 744)
2-Position
DIN 5480
Speed
Radial
Axial
SAE C
100
90 Vent port
Air from tank Air to vent port
80 (upper side)
Idle Losses PLV [%]
70
60
50
Compact
40
Oil / air mixture unit
30
from
20
suction port
10
0 Shift in
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Motion
Speed [rpm]
Idle losses are composed of flow losses in canals The feed flow generates a vacuum via the venturi The oil/air mixture is returned to tank via diffuser/
and kidneys, friction losses in gaps and bearings nozzle. Oil is sucked up on motor bottom side. filter. Oil/air mixture is calmed - air is separated out.
and windage losses. The diagram above shows the Air to fill the vacuum is filled in on motor upper side. The air for filling the motor housing is drawn from
comparison between the losses of two motor the tank above the liquid level.
concepts and the great effects of “dry case”
under identical conditions.
Open & Closed Circuit. MOTORS
CMF
Nominal size 80
Displacement cc/rev 80
Max. operating speed rpm 4500
Speed
Max. speed* rpm 5000
Nominal pressure bar 450
Pressure Max. pressure** bar 500
Compact
Max. housing pressure bar 2.5
unit Torque ( p=430 bar; charge press.=20 bar) Nm 547
Corner power (theor.) (Vmax x nmax x p 430 bar) kW 258
Shift in
Weight (approx.)*** (without oil) kg 23.0
Motion
Customer interfaces
Compagnion flange
SAE C 4-bolt: 127-4
Plug-in, similar to
ISO 6149 – 1
ISO 3019-1
ISO 6162-2
ISO 6162-2
(SAEJ 744)
Side ports
DIN 5480
Speed
2-bolt
Work ports
LEARN MORE Threaded ports
CMF
* highest transient speed, that can temporarily occur | ** highest transient pressure, that can temporarily occur | **** Availability depends on nominal size
MOTORS
Open & Closed Circuit.
Fixed Displacement Motor. HMF-02/HMA-02.
Design characteristics
Product advantages
HMF-02/HMA-02
Nominal size 35 55 63 75 85 105 135 165 210 280
Displacement cc/rev 35,6 54,7 63 75,9 85,6 105 135,6 165,6 210 281,9
Max. operating speed rpm 4500 4100 3900 3800 3600 3500 3200 3100 2700 2400
Speed
Max. speed* rpm 4800 4400 4200 4100 3850 3800 3500 3400 3000 2700
Nominal pressure bar 450 450 450 450 450 450 450 450 450 450
Pressure Max. pressure** bar 500 500 500 500 500 500 500 500 500 500
Max. housing pressure bar 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 Compact
Torque ( p=430 bar; charge press.=20 bar) Nm 244 374 431 519 586 719 928 1133 1438 1929 unit
Corner power (theor.) (Vmax x nmax x p 430 bar) kW 115 161 176 207 221 263 311 368 407 485
Weight (approx.)*** (without oil) kg 16 19 24 26 33 33 39 76 101 146 Shift in
Motion
Customer interfaces
4 hole
ISO 6149 – 1
ISO 3019-1
ISO 6162-2
(SAEJ 744)
DIN 5480
210, 280
SAE B
Speed
Radial
SAE C
SAE D Work ports
SAE E Threaded ports LEARN MORE
HMF-02 / HMA-02
* highest transient speed, that can temporarily occur | ** highest transient pressure, that can temporarily occur | **** Availability depends on nominal size
Closed Circuit. ACTUATORS
Actuator
Customer interfaces
position sensor
AMP Connector
Proportional
ISO 6149-1,
M14 x 1.5
M 16
12 V
24 V
K-02
Nominal size 55/55 75/75 105/105
Displacement Max. displacement cc/rev 55/55 75/75 105/105
Max. operating speed rpm 3900 3400 3200
Speed
Max. speed* rpm 4150 3600 3400 Compact
unit
Nominal pressure bar 450 450 450
Pressure Max. pressure** bar 500 500 500
Max. housing pressure bar 2.5 2.5 2.5 Shift in
Motion
Torque Torque ( p=430 bar; charge press.=20 bar) Nm 374 519 719
Corner power (theor.) (Vmax x nmax x p 430 bar) kW 153 185 241
Customer interfaces
Enable function
holes (d=17,5mm)
Speed sensor
Swash angle
Compagnion
Proportional
ISO 3019-1
ISO 6149-1
ISO 6162-2
ISO 6162-2
(SAEJ 744)
Twin ports
3-Position
Side ports
threads M12
threads M16
4 additional
4 additional
additional
2 hole,
2 hole,
2 hole,
flange
2 hole
4 hole
SAE-B
Work ports
Electro-hydraulic SAE-C
SAE-D
SAE-E
Threaded ports
LEARN MORE
K-02
* highest transient speed, that can temporarily occur | ** highest transient pressure, that can temporarily occur | **** Availability depends on nominal size
Closed Circuit. SYSTEMS
Concept
Compact
unit
Shift in
Motion
Implementation
Linde Hydraulics components Customer interface System requirements
Electronic control unit iCon Shift rod with clevis or spherical head Stop to shift gearbox with two or more
Variable displacement pump HPV-02 gears and defined neutral position
Multiple positions of rest and
Variable displacement motor HMV-02 analog position signal
Admissible tractive effort
Shift actuator Actuator Defined default behavior interruption of <0.7 sec
LEARN MORE
SHIFT IN MOTION
SYSTEMS
Closed Circuit.
Hydrostatic Drive. Shift in Motion.
Application examples
D A
C
B
A D
Compact
unit
Shift in
Motion
Category Category
45 kW 70 kW 250 kW 35 kW 90 kW 250 kW
Equipment Equipment
A 1 x HPV 75-02 E2 A 1 x HPV 105-02 E2
B 1 x HMV 105-02 E6 B 1 x HMV 135-02 E6
C 1 x iCon® C 1 x iCon®
D 1 x Actuator D 1 x Actuator LEARN MORE
SHIFT IN MOTION
Linde Hydraulics Worldwide. LINDE HYDRAULICS WORLDWIDE
Sales Partners.
— Development projects
— Application engineering
— Commissioning
— Series production
Compact
unit
Coverage of sales & service partners
Shift in
Motion
at www.lhy.com/network
Shift in
Motion
LEARN MORE
ONLINE SHOP
How to reach us. Linde Hydraulics Worldwide.
LHY.PC.05/24.e
Post Linde Hydraulics GmbH & Co. KG (BR) Linde Hydraulics South America
Wailandtstrasse 13 Av. Leôncio de Magalhães, 1004 cj. 33, 02042-001 São Paulo
63741 Aschaffenburg Phone +55 11 2281 7879, info.br@linde-hydraulics.co
Germany
(ES) Linde Hydraulics Ibérica, S.L.U.
Avda. Prat de la Riba, 181, 08780 Palleja (Barcelona)
Phone +49.60 21.150-00 switchboard
Phone +34 93 663 32 58, info@linde-hydraulics.com.es
Fax +49.60 21.150-115 70
(FR) Linde Hydraulics France SARL
E-Mail info@lhy.com 1, rue du Maréchal de Lattre de Tassigny, 78854 Elancourt
Internet www.lhy.com Phone +33 130 684 675, info@linde-hydraulics.com
Visit
www.lhy.com/network
to find a sales or service partner
close to you.