Industrial AC Drive Solutions

Based on over three decades of experience in various industries, L&T offers reliable AC drive solutions tailored to specific industry needs. They provide extensive after-sales service including rapid response teams, spare parts, and training to maximize customer uptime. L&T drives undergo stringent testing and certification to international standards to ensure high quality and reliability.

Uploaded by

Albert Sekar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views36 pages

Industrial AC Drive Solutions

Based on over three decades of experience in various industries, L&T offers reliable AC drive solutions tailored to specific industry needs. They provide extensive after-sales service including rapid response teams, spare parts, and training to maximize customer uptime. L&T drives undergo stringent testing and certification to international standards to ensure high quality and reliability.

Uploaded by

Albert Sekar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 36

Based on experience

Backed by commitment

Series AC Drive
The new reliability edge

AC Drive Series
Contents Over three decades of application knowledge
Page For over three decades, various industry sectors have been reaping
the benefits of L&T's cost-effective, performance-oriented AC Drive
Flexi Series Fx2000 7 solutions. L&T's grasp of the specific needs of each industry enables
it to offer application-specific solutions for various industries – such
Smart Series Sx2000 17 as processing, textile, plastic, ceramic, pharmaceutical, elevator,
oil & gas, power, cement and material-handling.
Energy Saver HVAC Series Hx2000 27

Compact Series Cx2000 43

Smart Series Sx2000 IP66 51

Accessories 56

Peripheral Devices 59

Other Automation Products 62

1
A knowledge-based company, L&T brings you the benefits A malfunction of the drive can bring an entire assembly line
of over 75 years of engineering experience and expertise, or process to a halt. To ensure maximum uptime for you,
and the richness of its collaborations with technology leaders our Rapid Response service team is available to analyze the
Backed by engineering across the globe.
After-sales service situation and help you set the problem right. We have set
knowledge across seven decades aimed at maximum uptime up strategic service centres across the country to provide
For 50 years, L&T's low-tension switchgear – India's widest temporary replacement drives or ready spares to ensure that
range – has been the preferred option of top industrial your business keeps running smoothly.
houses countrywide.

At our countrywide Switchgear Training Centres, we can


train your operators, electricians and supervisors to increase
L&T is one of the few switchgear manufacturers in India with their effectiveness in the operation and maintenance and
a dedicated, NABL-certified testing facility. Our products are trouble-shooting of your drives. We can also conduct in-
tested for conformity to standards that exceed mandatory plant training and workshops at your premises to improve
requirements, giving you the assurance of high-quality Training your people both power management and equipment maintenance
Tested. Certified. Reliable. performance. Our focus on continuous improvement ensures skills. This gives you total operational excellence, minimising
that our quality is on par with the best in the world. Repeat
to enhance your operations downtime.
orders endorse the value that we deliver.
L&T's engineers and channel partners also upgrade their skills
The reliability of the x2000 series AC Drives is ensured by through seminars, workshops, training sessions and white
international test certification – UL, CE and RoHS. papers on electrical practices.

2 3
AC Drives

Range
Salient Features Advantages Benefits
Built-in 24V Power Source Reduced wiring & no need of external SMPS No extra cost & space for SMPS & its mounting
No need of external potentiometer, possible to add No extra expenditure of external potentiometer, IP66
Built-in potentiometer
reference from keypad and external signal simple panel wiring and no panel cut-out
Complies to IEC 60721-3-3 class 3C3. Improves life
Conformal Coating of electronic circuit in harsh environments, even Increased life of drive
reduces downtime
Maintains desired pressure or flow by operating
Booster Pump Control Saving on cost of external controller
pumps run by conventional starters
It creates a simple sequence from a combination of
User Sequence Saving on cost of external hardware or
different function blocks. No software required to
(PLC Functionality) extra PLC
create logic.
One master keypad can monitor/program 16 slave
Multi Keypad Saving on cost of external display for slave drives
drives
0.1kW 0.75kW 11kW 22kW 90kW 375kW
Peer-to-Peer Allows the drives to share any I/O via inbuilt RS485
Saving on cost of external I/O expansion card
Communication communication
Automatically switches OFF the drive during user-
Energy-saving as well as saving on wear and tear
Sleep & Wake PID Function programmed low-load conditions and then to
of mechanical system
startup again when process demand increases
Provides external brake control function for vertical
Brake Control Improves safety
load such as crane & elevator 1-Phase 230V 0.1 to 2.2kW (HD) 1-Phase 230V 0.75 to 3.7kW (ND)
Performs a general acceleration until the set Cx2000: 3-Phase 230V 0.2 to 11kW (ND) Sx2000: 3-Phase 230V 0.75 to 18.5kW (ND)
Pre PID Smooth PID operation
frequency is reached
3-Phase 415V 0.75 to 11kW (ND) 3-Phase 415V 0.75 to 90kW (ND), 0.4 to 22kW (HD) - IP66
Single AC drive can maintain two motor parameters
Fx2000: 3-Phase 415V 0.75 to 375kW (HD) Hx2000: 3-Phase 415V 0.75 to 90kW (ND)
connected to two different loads, different accel / For isolated operation of motors one VFD can be
2nd Motor Operation
deaccl time, motor current & protection for both used in place of two
the motors
Built-in Chopper Ease of wiring, saves space No external DBU required, hence reduced cost
Model type & Selection:
Built-in DC Reactor Reduced harmonics and improved power factor No external reactor required
If a machine needs to stop in an emergency, circuit
Built-in Safety Circuit Additional human & machine safety
will block the drive output. LTVF x x xxxx x x A
Control card of the existing drive can be replaced to
Removable Terminal Block Reduces downtime for AC drive replacement
new drive without removing control wiring
Component Life Digital output can be triggered when components Pre-alarm for capacitor failure, avoiding
Monitoring eg. capacitor have completed their lifespan breakdown Input Voltage Drive Current Enclosure Keypad Reserved
L&T Variable Series
Suction structure for internal cooling system Frequency Drive Rating
Enhanced Cooling Design enhances their protection and improves the life of Improves operating life of IGBT & AC drive C Cx2000 Single-Phase (ND)* A IP00 A With
1
drive in dusty working environment 200~240[V]
S Sx2000 Three-Phase B IP20 **B Without
RS485 Modbus Ease of communication with 3rd party devices on 2
No extra cost for RS485 Modbus 200~240[V]
Communication MODBUS
F Fx2000 Three-Phase C IP21
Complies to EU Directive 2002/95/EC stands for 4
RoHS-compliant Lead-free products, environment-friendly 380~480[V]
restriction of hazardous substances H Hx2000 X IP66
Useful protection in overhauling applications
No Motor Detection Drive trips when all the 3 phases are disconnected
running with external mechanical brake

*For Cx2000 230Vac Single-Phase and Sx2000 IP66 drive mentioned current is for HD rating.
**Valid for Cx2000 series only.

4 5
Applications
x2000 Series Applications Cx2000 Sx2000 Fx2000 Hx2000

Blowers • • •
ID / FD Fan • • •
Pump • • •
Conveyors • • •
Compressors • •
Crane Hoisting • •
Crane Traverse • • •
HVAC •
Damper Control • • •
Agitator • •
Lifts Door Control •
DIGITAL OPERATOR
Lifts & Escalators • • DOP-200

AHU • • •
Winders • •
Wire Drawing • •
Ball Mill • •
Textile Machinery • •* •
Centrifuge • •
Extruder • •
Spinning Machine •* •
Rotary Klins •
Printing • • •
Crushers • •
Hydraulic Press • •
Plastic Machinery • • •
Food Packaging • •* •
Solar Pump •
Mixers • •
Tank Rotator • •
Pulper • •
Tea Making • • •
Rubber Machinery • •
Machine Tools • • •
Material Handling • • •
Note: Above chart is only a general guideline. Please contact us with exact details of your application. *Sx2000 IP66 is best suaitable for this application.

6
The Fx2000 generates powerful performance and meets your precise needs through several
features: superior V/F control, V/F PG, slip compensation and sensorless vector control as well as Features
closed-loop vector control.

The Fx2000 is perfectly suited for the toughest, most complex applications – cranes, plastic winders,
high-speed elevators, cement kilns, crushers… and more. It handles loads up to 375 kW - HD /
450 kW - ND, and is engineered to keep your machine operating at optimum efficiency, even in the Automatic Torque Balance droop control
hot, humid and dusty conditions that characterize India's industrial environment. Droop control algorithm adjusts changeable torque driven by
speed. This algorithm is easily applicable to open-loop linking
driving and load sharing driving.

DIGITAL OPERATOR
DOP-200

Ride-through (LV trip delay)


for sudden power loss

Kinetic Energy Buffering (KEB)


for a stable system stop in case
of power loss or failure

Main Features
n Range: 0.75kW to 375kW (HD)
n V/F control, V/F with PG, Applications Closed Loop Vector realizing precise
Slip compensation, Sensorless speed/torque control
Vector Control, Close Loop Vector In the entire speed range including zero speed, powerful torque
n Crane Hoist
Control (up to 250%) performance is materialized through receiving
n Crane Control LT / CT Max. 200kHz frequency pulse via an encoder-dedicated board.
n Built-in Macro for Crane • Speed control range 1000:1
n Winders • Instant Max. torque control capability 250%
n Starting Torque: 250% at 0Hz for • 50Hz speed control response
n Wire Drawing
Closed Loop
n Plastic & Textile Machines
n Optional Smart PLC
n Optional n Conveyors
Synchronization card
n Compressors
n Droop Control Powerful current sensorless vector control
n Extruders
n Conformal Coating complying to Our Fx2000 technology includes a competitive and strong
low-speed torque control and a speed-precision-driven vector
IEC 60721-3-3 class 3C2 (max) n Fan
algorithm.
and class 3C3 (avg) n Pump • Speed control range 100:1
• Extremely low torque control capability: 0.1Hz/150%
n Built-in RS485 Modbus RTU real torque
Communication • Max. torque control capability within the restoration range

8 9
Features Features

Built-in Crane Algorithm


DC reactor built-in* for harmonic
Enhance-Torque Control
reduction and power factor • 250% starting torque in closed loop control
improvement • Overload capacity of 200% for 3 seconds

* From 22kW to 280kW (ND) Built-in Brake Control


• Brake opening command by drive under the following
conditions:
• Inverter Output Frequency > Brake Release Frequency
• Inverter Output Current > Brake Release Current
• Brake release with delay
• Ensures Slip prevention
• Brake Close frequency different settings possible for
Hoisting & Lowering Motion
Multi-function key
It can be programmed for different
functions like Remote / Local,
User / Macro Selection & JOG

Position Control Option


Efficient architecture of
5-mode 15-parameter groups • Suitable for applications like cut to length
• Pulse train reference upto 200khz
Each mode has its own function items suitable • No need of external controller
for desired properties • Reduces cycle time
• Reduces wastage of material
eg. Monitor: Displays information on the operating
status of the inverter

User & Macro group support


• User can define parameters together they use
often in User Macro
• Maximum 64 number of parameters can be
saved
• Same parameter can be saved several times

Synchronisation Control
• Suitable for applications like roving frame,
ring frame
Wide viewing-angle graphic • Maximum frequency upto 100kHz
• Position/Speed synchronization possible
LCD keypad
• 3 LED
• 11 Keys
• 4 Lines for monitoring
• Built-in memory to store parameters on keypad

10 11
Specifications Specifications

Rated Input and Output: Input Voltage Three-Phase 415V (0.75 to 22kW - HD) Three-Phase 415V, 0.75 to 375kW (HD)
Range

Type : LTVF-F4oooo oAA 0004 0006 0008 0012 0016 0024 0030 0039 0045 0061 Enclosure Type IP21 below 75kW (HD) & IP00 above 90kW till 375kW (HD)
HD 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 Overload Capacity HD: 150%/ 1min; ND: 110%/ 1min, 200% instantaneous for 3 seconds
1)
Applicable Motor (kW)

Standard Specifications
ND 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 Max Output Voltage Proportional to input voltage
HD 2.5 4 6 8 12 16 24 30 39 45 Max Output Frequency 0 to 400Hz (1000Hz optional)
2)
Rated Capacity [A]
ND 4 6 8 12 16 24 30 39 45 61 (Sensorless-1: 0 to 300Hz, Sensorless-2, Vector: 0.0~120Hz)
Rated Rated Capacity [kVA]-HD 1.9 3 4.5 6.1 9.1 12.2 18.3 22.9 29.7 34.3 Rated Voltage 380 to 480V Three-phase (-15%/+10%)
Output
Output Frequency
0 ~ 400 [Hz] 3)
Rated Frequency 50/60Hz (-5/+5%)
(Sensorless-1: 0~300Hz, Sensorless-2, Vector: 0.1~120Hz)
Keypad LCD Detachable
Output Voltage [V] 4)
3-phase 380 ~ 480V
Available Voltage [V] 3-phase 380 ~ 480 VAC (-15%, +10%)
DC Reactor Built-in from 22kW (HD) to 280kW (ND)
Input Frequency 50 ~ 60 [Hz] (±5%) Braking Chopper Built-in till 22kW (HD)
Rated
Input HD 2.2 3.6 5.5 7.5 11 14.4 22 26.6 35.6 41.6 Control Method V/F, V/F with PG, Closed Loop Vector Control, Sensorless Vector Control,
Rated Current [A]
ND 3.7 5.7 7.7 11.1 14.7 21.9 26.4 35.5 41.1 55.7 Slip Compensation
DC Reactor External [option] Built-in Starting Torque 150% for 60 Sec, 200% / 0.3Hz (Sensorless), 250% / 0RPM (Vector)
Braking Unit Built-in Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector
Frequency Precision Setting Digital command operation : 0.01% of the maximum frequency
Analog command operation : 0.1% of the maximum frequency

Control Details
Frequency Setting Analog: 0 ~ 10[V], -10 ~ 10[V], 0 ~ 20[mA]
Digital: keypad
Rated Input and Output: Input Voltage Three-Phase 415V (30 to 375kW - HD)
Output Frequency Resolution 0.01Hz

0075 0091 0110 0152 0183 0223 0264 0325 0370 0432 0547 0613 0731 0877
V/F pattern Linear, double reduction, user V/F
Type : LTVF-F4oooo oAA
HD 30 37 45 55 75 90 110 132 160 185 220 280 315 375 Accel/Decel Time 0.0 to 6000 Sec
1)
Applicable Motor (kW)
ND 37 45 55 75 90 110 132 160 185 220 280 315 375 450 Braking Torque Continuous Regeneration Torque 20% (150% with DBR)
Rated Capacity [kVA]-HD 46 57 69 84 116 139 170 201 248 286 329 416 467 557 Features PID control, up-down, 2nd motor operation, 3-wire operation, DC break, frequency limit,
HD 61 75 91 110 152 183 223 264 325 370 432 547 613 731 frequency jump, second source function, slip compensation, reverse rotation prevention,
2)
Rated Capacity [A] auto restarting, auto tuning flying start, energy buffering, power breaking, flux breaking,
Rated ND 75 91 110 152 183 223 264 325 370 432 547 613 731 877
leakage current reduction, MMC, easy start
Output 3)
0 ~ 400 [Hz]
Output Frequency Over voltage, low voltage, over current, earth current detection, inverter overheat,
(Sensorless-1: 0~300Hz, Sensorless-2, Vector: 0.1~120Hz)
motor overheating, output imaging, overload protection, communication error,
Output Voltage [V] 4)
3-phase 380 ~ 480V Faults
frequency command loss, hardware failure, cooling fan failure, pre-PID failure,

Protection
Available Voltage [V] 3-phase 380 ~ 480 VAC (-15%, +10%) no motor trip, external break trip
Rated Input Frequency 50 ~ 60 [Hz] (±5%) Alarm Stall prevention, overload, light load, encoder error, fan failure, keypad command loss,
Input HD 55.5 67.9 82.4 102.6 143.4 174.7 213.5 255.6 316.3 404 466 605 674 798 speed command loss
Rated Current [A]
ND 67.5 81.7 101.8 143.6 173.4 212.9 254.2 315.3 359.3 463 590 673 796 948 Momentary Power Loss Ride Through Continuous Operation: Heavy Loads below 15 msec & normal loads below 8msec
DC Reactor Built-in External [option] Auto Restarts: Heavy Loads above 15 msec & normal loads above 8msec
Braking Unit External [option] DI 8 (Programmable NPN/PNP)
DO 2 Programmable (1 NO/NC & 1 NO) + 1 TR

Interface
AI 1Nos, 4-20mA & 1Nos, 0 to 10Vdc
AO 1Nos, 4-20mA & 1Nos, 0 to 10Vdc
Communication Built-in RS485 Modbus RTU
Area of Use Indoors, There shall not be corrosive air, combustible gas, oil mist, dust and other
pollutants
Ambient Temperature -10oC to 50oC for HD, -10oC to 40oC for ND
Storage Temperature -20oC to 65oC
Environment

PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C2 (max) and class 3C3 (avg)
Application Humidity Below relative humidity 95% RH (no condensation)
Altitude Below 1000m
Vibration 5.9m/sec2 (0.6G)
1) Motor Applied indicates the maximum capacity applied to use of a standard 4 pole standard motor.
2) The output of rated current is limited according to setting of the carrier frequency (CON-04). Global Compliance CE, UL, RoHS
3) In case of Sensorless-1, you can set the frequency at up to 300Hz by selecting 3, 4 as the control mode (DRV-09 Control Mode).
In case of Sensorless-2, you can set the frequency at up to 120Hz by selecting 3, 4 as the control mode (DRV-09 Control Mode).
4) The maximum output voltage does not go up over the supplied power voltage. You can select the output voltage as you want below the supplied power voltage.

12 13
Optional Cards Optional Cards

Ethernet Card (LTCI-ETH-F)


PLC Card (LTAD-PLC-F) • Modbus TCP, Ethernet IP Protocol support
• 10Mbps, 100Mbps communication speed
• Normal input 6 points (Sink/Source selectable),
• Half duplex, full duplex support
Max. input 14 points when expanded
• Auto negotiation
• Normal output 4 points (N.O. Relay), Max. output
• Max. 100m(328 ft.) transmission distance
7 points when expanded
• CSMA/CD communication access method
• RTC (Real Time Clock)
Analog voltage (-10~10V) I/O 2 points
Analog current (0~20mA) I/O 2 pointst

Encoder Card (LTEN-INC-F)


• Closed loop control
DeviceNet (LTCI-DEN-F)
• Pulse train reference • Communication speed:125kbps, 250kbps, 500kbps
• Line driver or open collector type of encoders • Tree/Bus topology
• 200kHz max. input frequency • Max. 64 node connection points
• Signal loss detection • Max. 500m (1640 ft.) transmission distance (125kbps)
• 5/12/15 V insulated power supply

Profibus-DP Card (LTCI-PDP-F)


CANopen Card (LTCI-CAN-F)
• Profibus dedicated connector
• Max. 12Mbps communication speed • 1Mbps communication speed
• Max. 32 stations per segment • Bus Topology
• Bus topology • Max. 64 node connection points (include master)
• Enhanced on-line diagnosis

Synchronization Option Card


I/O Expansion Card 1 (LTIO-EX1-F) (LTCN-SYN-F)
• Digital input - 3 (PNP / NPN) • Closed-loop control
• Digital output - 3 (NO) AC 250V - 5A / DC 30V - 5A • 100kHz max. input frequency
• Analog input - 2, 1 Voltage (-10 to +10V) • For parallel connection 15 slaves per master (5 parallel max)
1 Current (0 to 20mA) • For serial connection 5 slaves per master
• Analog output - 2, 1 Voltage (-10 to +10V) • Position/Speed synchronization
1 Current (0 to 20mA) • Synchronization hold (only slave)
• Open collector output: 26V/100mA (2 points)

Position Control Option Card


I/O Expansion Card 2 (LTIO-EX2-F) (LTCN-PCN-F)
• Digital output - 2 (TR) Max 26V, 100mA • Closed-loop control
• Analog input - 4, Voltage (-10 to +10V) / • Pulse train reference
Current (0 to 20mA) • Line driver or open collector type of encoders
• Analog output - 4, 2 Voltage (-10 to +10V) • 200kHz max. input frequency
2 Current (0 to 20mA) • Signal loss detection
• External brake control
• 5/12/15V insulated power supply

14 15
Dimensions & Weights

Drive Cat No W (mm) H (mm) D (mm) Weight (kg)

LTVF-F40004CAA 150.0 284.0 200.0 4.8

LTVF-F40006CAA 150.0 284.0 200.0 4.8

LTVF-F40008CAA 150.0 284.0 200.0 4.8

LTVF-F40012CAA 150.0 284.0 200.0 4.8

LTVF-F40016CAA 200.0 355.0 225.0 8.0

LTVF-F40024CAA 200.0 355.0 225.0 8.0

LTVF-F40030CAA 250.0 385.0 284.0 14.3

LTVF-F40039CAA 250.0 385.0 284.0 14.3

LTVF-F40045CAA 280.0 461.0 298.0 20.0

LTVF-F40061CAA 280.0 461.0 298.0 30.3

LTVF-F40075CAA 300.1 594.1 303.2 41.3

LTVF-F40091CAA 300.1 594.1 303.2 41.3

LTVF-F40110CAA 300.1 594.1 303.2 41.3

LTVF-F40152CAA 370.1 663.5 373.3 63.3

LTVF-F40183CAA 370.1 663.5 373.3 63.3

LTVF-F40223AAA 510.0 783.5 422.6 101.3

LTVF-F40264AAA 510.0 783.5 422.6 101.0

LTVF-F40325AAA 510.0 861.0 422.6 114.0

LTVF-F40370AAA 510.0 861.0 422.6 114.0

LTVF-F40432AAA 690.0 1,078.0 450.0 200.0

LTVF-F40547AAA 690.0 1,078.0 450.0 200.0

LTVF-F40613AAA 771.0 1,138.0 440.0 252.0

LTVF-F40731AAA 922.0 1,302.5 495.0 352.0

LTVF-F40877AAA 922.0 1,302.5 495.0 352.0

Note: The above drawings are solely for reference purposes. Please refer to the technical manual.

16 17
The Sx2000 adds a new dimension to L&T's AC drive solutions. Built to L&T's stringent quality
standards, the Sx2000 is tested and certified to meet global benchmarks, giving you the assurance Features
of total reliability. The Sx2000 is built to deliver powerful performance. It produces a starting torque
of 200% at 0.5 Hz, which provides better control at low-speed. Its compact size enables panel-size
reduction, hence helps in space-efficient design. Multi-keypad function
Parameter change with a single keypad.

Single LCD keypad can be used to set up the parameters of


RS485 connected drives.

• LCD (LTOP-DOP-200) keypad (same as Fx2000 model)


enables handy parameter set-up.
• Multi-language support available

User sequence function (PLC Logic)


• Simple PLC sequences can be operated with various
function block combinations with direct access to Drive
parameters.
• Function blocks: AND, NOR, ADD, SUB, XOR, MIN, MAX,
COMPARE, TIMER, SWITCH, UP/DWN COUNT..etc
• No Software required to create logic

Peer-to-Peer function embedded


RS485 MODBUS
Communication I/O's can be shared among master and slave drives.
(RS485 wiring required).
Main Features

n Range: 0.75kW to 90kW


n V/F, Sensorless Vector Control, Applications
Slip Compensation Built-in Brake Control
n Starting Torque of 200% n OEM Machines • Brake opening command by drive under the following
at 0.5Hz for Sensorless Control n Elevators conditions:
• Inverter Output Frequency > Brake Release Frequency
n Component Life Monitor n Plastic & Textile Machines • Inverter Output Current > Brake Release Current
n Peer to Peer Communication to n Conveyors
• Brake release with delay
• Ensures Slip prevention
share I/Os • Brake Close frequency different settings possible for
n Compressors Hoisting & Lowering Motion
n Built-in PLC Logic
n Wire Drawing
n Built-in Brake Control
n Extruders
n Multi Keypad
n Stores last 5 faults
n AHU Control Safety Function
n Conformal Coating complying to
n Fan & Pump Sx2000 has in-built safety functions conforming to modern
safety standards.
n Crane Hoist
IEC 60721-3-3 class 3C2 (max)
The safety input function meets EN ISO 13849-1 PLd and EN
and class 3C3 (avg) n Crane Control LT / CT 61508 SIL2 (EN60204-1, stop category 0).
n Built-in RS485 Modbus RTU n Solar Pump This feature is standard and enables compliance with current
safety standards.
Communication • Safety relay needs to be purchased separately.

18 19
Features Features

Optional Accessories - easy to install & use


Profibus-DP (LTCI-PDP-S.)
Powerful sensorless *Optional fieldbus
1
2 Modbus TCP / Ethernet IP (LTCI-ETH-S.)
control networks: 3 CANopen (LTCI-CAN-S)
Starting torque of 200%/0.5Hz *I/O Expansion Card (LTIO-EXP-S.):
is produced and provides robust
• Digital input - 3 (PNP / NPN)
power in the low speed region. • Digital output - 2 (R) AC 250V - 1A / DC 30V - 1A
The motor auto-tuning function • Analog input - 2, 1 Voltage (-10 to +10V)
is optimised to maximise motor 1 Current (0 to 20mA) / 1 Voltage (0 to +10V)
performance. • Analog output - 1, 1 Voltage (0 to +10V) / 1 Current (0 to 20mA)
*Only one option card can be used at a time.

Simple cooling fan replacement


Tool-less replacement of cooling fan without dismantling
the drive
Flying-start function
Drive capable of reliable and
smooth re-starts even for
bi-directional rotating loads.

Flange type
To reduce heat losses inside the panel
The heat sink can be mounted outside of the panel in case the
space is limited.

Main capacitor *Please contact L&T representative for details.

lifecycle estimation
Estimated through monitoring the
change in the capacitance value. Built-in DC reactor Dual rating operation
Effective in improving power factor and decreasing THD. Designed to be used for heavy and normal duty applications.
• 3-phase 400V 37~90kW (ND)
Overload capacity:
– Heavy duty operation 150% of rated current, 60 seconds
– Normal duty operation 120% of rated current, 60 seconds

DriveConnect software allows drive/system


monitoring on a PC and easy maintenance
of drive and motor parameters
Fan lifecycle • Windows-based graphic user interface (GUI)
estimation • Modbus-RTU
• Connecting up to 31 drives
Warning signal is displayed • Integrated control console
when fan is operated over a • Offline editing function
certain amount of hours. • Data upload/download
• 4-channel oscilloscope
• Trigger function

20 21
Specifications Specifications

Input and output specification: Input Voltage Single-Phase 230V (0.75 to 3.7kW - ND) Input and output specification: Input Voltage Three-Phase 415V (0.75 to 30kW - ND)
LTVF-S1 oooo BAA 0003 0006 0010 0012 LTVF-S4 oooo BAA 0002 0003 0005 0007 0010 0016 0023 0030 0038 0044 0058

Heavy HP 0.5 1.0 2.0 3.0 Heavy HP 0.5 1.0 2.0 3.0 5.4 7.5 10.0 15.0 20.0 25.0 30.0
Duty [HD] kW 0.4 0.75 1.5 2.2 Duty [HD] kW 0.4 0.75 1.5 2.2 4.0 5.5 7.5 11.0 15.0 18.5 22.0
Applicable Applicable
Motor HP 1.0 2.0 3.0 5.0 Motor HP 1.0 2.0 3.0 5.0 7.5 10.0 15.0 20.0 25.0 30.0 40.0
Normal Normal
Duty [ND] kW 0.75 1.5 2.2 3.7 Duty [ND] kW 0.75 1.5 2.2 3.7 5.5 7.5 11.0 15.0 18.5 22.0 30.0

Capacity Heavy Duty [HD] 1.0 1.9 3.0 4.2 Capacity Heavy Duty [HD] 1.0 1.9 3.0 4.2 6.5 9.1 12.2 18.3 22.9 29.7 34.3
[kVA] Normal Duty [ND] 1.2 2.3 3.8 4.6 [kVA] Normal Duty [ND] 1.5 2.4 3.9 5.3 7.6 12.2 17.5 22,9 29.0 33.5 44.2

Output Rated Heavy Duty [HD] 2.5 5.0 8.0 11.0 Output Rated Heavy Duty [HD] 1.3 2.5 4.0 5.5 9.0 12.0 16.0 24.0 30.0 39.0 45.0
Rating Current [A] Normal Duty [ND] 3.1 6.0 9.6 12.0 Rating Current [A] Normal Duty [ND] 2.0 3.1 5.1 6.9 10.0 16.0 23.0 30.0 38.0 44.0 58.0
Frequency [Hz] 0~400Hz (IM Sensorless : 0~120[Hz]) Frequency [Hz] 0~400Hz (IM Sensorless : 0~120[Hz])
Voltage [V] 3-phase 200~240V Voltage [V] 3-phase 380~480V
Voltage [V] 1-phase 200~240VAC (-15% ~ +10%) Voltage [V] 3-phase 380~480VAC (-15% ~ +10%)

Input Frequency [Hz] 50~60Hz (±5%) Input Frequency [Hz] 50~60Hz (±5%)
Rating Heavy Duty [HD] 4.8 9.3 15.6 21.7 Rating Heavy Duty [HD] 1.1 2.4 4.2 5.9 9.8 12.9 17.5 26.5 33.4 43.6 50.7
Rated Rated
Current [A] Normal Duty [ND] 5.8 11.7 19.7 24.0 Current [A] Normal Duty [ND] 2.0 3.3 5.5 7.5 10.8 17.5 25.4 33.4 42.5 49.5 65.7
Display LED [LCD optional] DC Reactor External [option]
Braking Unit Built-in Display LED [LCD optional]
Braking Unit Built-in

Input and output specification: Input Voltage Three-Phase 230V (0.75 to 18.5kW - ND) Input and output specification: Input Voltage Three-Phase 415V (37 to 90kW - ND)
LTVF-S2 oooo BAA 0003 0006 0010 0012 0018 0030 0040 0056 0069 LTVF-S4 oooo BAA 0075 0091 0107 0142 0169

Heavy HP 0.5 1.0 2.0 3.0 5.4 7.5 10.0 15.0 20.0 Heavy HP 40.0 50.0 60.0 75.0 100.0
Duty [HD] kW 0.4 0.75 1.5 2.2 4.0 5.5 7.5 11.0 15.0 Duty [HD] kW 30.0 37.0 45.0 55.0 75.0
Applicable Applicable
Motor HP 1.0 2.0 3.0 5.0 7.5 10.0 15.0 20.0 25.0 Motor HP 50.0 60.0 75.0 100.0 120.0
Normal Normal
Duty [ND] kW 0.75 1.5 2.2 3.7 5.5 7.5 11.0 15.0 18.5 Duty [ND] kW 37.0 45.0 55.0 75.0 90.0

Capacity Heavy Duty [HD] 1.0 1.9 3.0 4.2 6.5 9.1 12.2 17.5 22.9 Capacity Heavy Duty [HD] 46.5 57.2 69.4 83.8 115.8
[kVA] Normal Duty [ND] 1.2 2.3 3.8 4.6 6.9 11.4 15.2 21.3 26.3 [kVA] Normal Duty [ND] 57.2 69.4 81.5 108.2 128.8

Output Rated Heavy Duty [HD] 2.5 5.0 8.0 11.0 17.0 24.0 32.0 46.0 60.0 Output Rated Heavy Duty [HD] 61.0 75.0 91.0 110.0 152.0
Rating Current [A] Normal Duty [ND] 3.1 6.0 9.6 12.0 18.0 30.0 40.0 56.0 69.0 Rating Current [A] Normal Duty [ND] 75.0 91.0 107.0 142.0 169.0
Frequency [Hz] 0~400Hz (IM Sensorless : 0~120[Hz]) Frequency [Hz] 0~400Hz (IM Sensorless : 0~120[Hz])
Voltage [V] 3-phase 200~240V Voltage [V] 3-phase 380~480V
Voltage [V] 3-phase 200~240VAC (-15% ~ +10%) Voltage [V] 3-phase 380~480VAC (-15% ~ +10%)

Input Frequency [Hz] 50~60Hz (±5%) Input Frequency [Hz] 50~60Hz (±5%)
Rating Heavy Duty [HD] 2.2 4.9 8.4 11.8 18.5 25.8 34.9 50.8 66.7 Rating Heavy Duty [HD] 56.0 69.0 85.0 103.0 143.0
Rated Rated
Current [A] Normal Duty [ND] 3.0 6.3 10.8 13.1 19.4 32.7 44.2 62.3 77.2 Current [A] Normal Duty [ND] 69.0 85.0 100.0 134.0 160.0
Display LED [LCD optional] DC Reactor Built-in
Braking Unit Built-in Display LCD
Braking Unit External [option]

22 23
Specifications Dimensions & Weights

Single-Phase 230V Three-Phase 230V Three-Phase 415V


Range
0.75 to 3.7kW (ND) 0.75 to 18.5kW (ND) 0.75 to 90kW (ND)
Enclosure Type IP20
Overload Capacity HD: 150% for 1min; ND: 120% for 1min
Max Output Voltage Proportional to Input Voltage
Standard Specifications

Max Output Frequency 0 to 400Hz (Sensorless: 0 to 120Hz)


Rated Voltage 380 to 480V Three-phase (-15%/+10%)
Rated Frequency 50/60Hz (-5/+5%)
Keypad Built-in LED till 30kW (ND) & Above 30kW standard Detachable LCD
Braking Chopper Built-in up to 30kW (ND)
DC Reactor Built-in from 37kW to 90kW
Control Method V/F, Sensorless Vector Control, Slip Compensation
Starting Torque 200% at 0.5Hz for Sensorless Control & 150% at 3Hz for V/F Input Voltage Drive Cat. No. W (mm) H (mm) D (mm) Weight (kg)
Single-Phase 230 V LTVF-S10003BAA 68 128 128 0.88
Frequency Control Range 0.01 to 400Hz for V/F , 0 to 120Hz for Sensorless Vector Control
LTVF-S20003BAA 68 128 123 0.86
Frequency Precision Setting Digital command: 0.01Hz Three-Phase 230 V
Analog command: 0.03Hz (Max. frequency: 60Hz) LTVF-S20006BAA 68 128 128 0.86
LTVF-S40002BAA 68 128 123 0.86
Frequency Setting Analog type: - 10 to 10V, +0 to 10[V], 4 to 20[mA], Three-Phase 415 V
Control Details

Digital type: Keypad, panel potentiometer, pulse train input LTVF-S40003BAA 68 128 128 0.88

Output Frequency Resolution 0.01Hz


V/F pattern Linear, squared, user V/F
Accel/Decel Time 0.0 to 6000 Sec
Braking Torque Continuous Regeneration Torque 20% (150% with DBR)
Features Multi keypad, peer-to-peer communication to share I/Os, user sequence, inbuilt PID, component life
monitor, no motor detection, auto tuning, KEB, DI/DO ON-OFF delay, torque boost,
DC braking, fire mode, flux braking, 2nd motor, frequency jump, slip compensation
Under load trip, low voltage trip, phase loss trip, no motor trip, external brake trip, safety input error,
Faults IO board trip inverter overload warning, lost command warning, overheat Trip, encoder trip,
DBR %ED warning
Protection

Alarm Command Loss trip, overload, inverter overload, fan operation, resistance braking
Momentary Power Loss Ride Continuous Operation: Heavy Loads less then 15msec, normal load less then 8msec,
Through Auto Restart Operation: Heavy Loads more then 15msec, normal load more then 8msec
DI 7 (Programmable NPN/PNP)
DO 1 (Programmable NO/NC) + 1 TR till 30kW,
2 (Programmable NO/NC) + 1 TR above 30kW
AI 1 (-10 + 10Vdc) & 1 (4-20mA / - 10 to + 10Vdc)
AO 1 (4-20mA / 0 to 10Vdc) till 30kW, Input Voltage Drive Cat. No. W (mm) H (mm) D (mm) Weight (kg)
Interface

1 (4-20mA / 0-10Vdc) + 1 (0 to 10Vdc) above 30kW LTVF-S10006BAA 100 128 130 1.3
Pulse Train 1 I/P & 1 O/P ( 0 to 32Khz) Single-Phase 230 V LTVF-S10010BAA 100 128 145 1.5
Communication Built-in RS485 Modbus RTU LTVF-S10012BAA 140 128 145 2.2

Safety I/P 2, complying with EN ISO 13849-1 Pld and EN61508SIL2 [EN60204-1, stop category 0] LTVF-S20010BAA 100 128 130 1.5

Area of Use Indoors. There shall not be corrosive air, combustible gas, oil mist, dust and Three-Phase 230 V LTVF-S20012BAA 100 128 145 1.5
other pollutants LTVF-S20018BAA 140 128 145 2.3

Ambient Temperature -10oC to 50oC for HD, -10oC to 40oC for ND LTVF-S40005BAA 100 128 130 1.5
Environment

Storage Temperature -20 C to 65 C


o o Three-Phase 415 V LTVF-S40007BAA 100 128 145 1.5
LTVF-S40010BAA 140 128 145 2.7
PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C2 (max) and class 3C3 (avg)
Application Humidity Below relative humidity 95% RH (no condensation)
Altitude Below 1000m
Vibration 9.8m/sec2 (1G)
Global Compliance CE, UL, RoHS
Note: The above drawings are solely for reference purposes. Please refer to the technical manual.

24 25
Dimensions & Weights

Input Voltage Drive Cat. No. W (mm) H (mm) D (mm) Weight (kg)
LTVF-S20030BAA 160 232 140 3.3
LTVF-S20040BAA 160 232 140 3.3
Three-Phase 230 V
LTVF-S20056BAA 180 290 163 4.6
LTVF-S20069BAA 220 350 187 4.6
LTVF-S40016BAA 160 232 140 3.3
LTVF-S40023BAA 160 232 140 3.4
LTVF-S40030BAA 180 290 163 4.6
Three-Phase 415 V
LTVF-S40038BAA 180 290 163 4.8
LTVF-S40044BAA 220 350 187 7.5
LTVF-S40058BAA 220 350 187 7.5

Input Voltage Drive Cat. No. W (mm) H (mm) D (mm) Weight (kg)
LTVF-S40075BAA 275 450 284 26
LTVF-S40091BAA 325 510 284 35
Three-Phase 415 V LTVF-S40107BAA 325 510 284 35
LTVF-S40142BAA 325 550 309 43
LTVF-S40169BAA 325 550 309 43

Note: The above drawings are solely for reference purposes. Please refer to the technical manual.

26 27
The Hx2000 adds a new dimension to L&T's AC drive solutions. It sets the standard for the
industry by introducing an innovative energy reduction, environmental-friendly system that delivers Features
outstanding energy savings for fan, pump and compressor applications in an HVAC system.

Built to L&T's stringent quality standards, the Hx2000 is tested and certified to meet global Multi Motor Control (MMC)
benchmarks, thus giving you the assurance of total reliability. It handles loads from 0.75kW to RLY1
MMC is used when a single drive is used to control multiple
90kW, and is engineered to keep your process operating at optimum efficiency, even in the hot, motors in pump systems. It controls 1 main motor and 5
RLY2

humid and dusty conditions that characterise India's industrial environment. auxiliary motors. RLY3

RLY4

The main motor is connected to the drive output and is RLY5


controlled by the built-in PID controller. Auxiliary motors are
connected with the supply power and are turned ON/OFF by
a relay within the drive.
4-20mA Pressure Feedback

Time Event Scheduling:


Real Time Clock (RTC)
RTC is used so that selected functions are operable during
Pre-Heat the set time. The user needs to configure the following:
Fx
Speed - L
• 4 Time Period Modules (Weekly)
Speed - H • 8 Time Events
• 8 Exception Dates (Day)
(Possible to set 29 functions including FWD (Fx), REV (Rx),
multiple acceleration/deceleration times, multiple frequencies,
Main Features PID related functions and pre-heat)
Summer time available (Start/End date setting)

n V/F, Slip Compensation


n Built-in RTC for Scheduling
n Password Protection
4 Process PID Control
n Built-in EMC filter class C3
Applications Main PID uses inputs from sensors to measure variables
0-10V / 0-20mA

n Fire Mode like pressure, temperature/humidity and flow, to change


Feedback Signal

Drive AO controls
n Multi-Motor Control the motor speed by varying the output frequency to Feedback Signal
Feedback Signal the chilled water
n Compressor achieve the desired process output.
modulating valve

n Built-in Payback Counter 0-10V / 0-20mA


n Supply Fan
Three external PIDs control the external equipments of
n Lubrication Control Drive Output Drive AO controls the
n Exhaust Fan outside air damper
the HVAC system such as dampers, valves based on the position based on outside
Drive controls the speed of the supply
n Pump Clean Control feedback from CO2, Rh, temperature, pressure & other fan to maintain system pressure
air temperature
n Cooling Tower
sensors.
n Dry Pump Detection
n Circulation Pump
n Built-in 4 PID
n Vaccume Pump
n Flow Compensation n Positive Displacement Pumps
n Built-in RS-485 Communication -

BACnet, Modbus-RTU, Metasys N2
Dry Pump (Under Load Protection)
n Global Specifications Compliant-
It prevents pump damage when there is insufficient
CE, UL (Plenum Rated) water in the tank. If the actual load is below the
n Conformal Coating complying to Under Load (UL) Detect curve, the drive will trigger a
IEC 60721-3-3 class 3C2 (max) and warning or trip signal to protect the pump.

class 3C3 (avg)

28 29
User Convenience Features

Soft Fill Operation


Energy Saving Prevents pump damage caused by excessive
pressure building-up in the pipe system at the
The energy saving information is displayed as kWh, saved energy cost time of initial operation of pumps or inside
and CO2 emission level on the drive keypad. the pumps.

Soft Fill

Keypad Exclusive for HVAC


Output
Used to issue commands, configure drive parameters, Frequency

and for monitoring drive status


• HAND Mode (Local Control Mode) or AUTO Mode Start Ramp & End Ramp
(Remote Control Mode) can be selected
Prevents pump damage by changing ramp using
- HAND Mode: Used when selecting frequency
acceleration/deceleration time setting upon
or run/stop commands
initial pump operation and stopping.
- AUTO Mode: Drive operated using the keypad,
multifunctional terminal block and
communications
• Fault Status Monitoring

Built-in EMC Filter


A built-in EMC filter meets the specifications for noise reduction
• 400V 0.75~90kW Built-in as default (Class C3)
Deceleration Valve Ramp
Built-in DC Reactor Prevents pump and pipe damage caused by
sudden pressure changes when pumps are
A built-in DC Reactor effectively improves the power factor and reduces the THD
stopped or a pump valve is closed, based on
• Built-in as standard for 400V 37~90kW
specific requirements, deceleration time
can be set.
Global Specifications Compliant
UL (Plenum Rated)
(American standards for conditioner fire safety)
• Suitable for installation in a compartment handling conditioned air

30 31
Features Features

Easy-to-Change Cooling Fan


It is easy to change a cooling fan without
opening the cover of the drive.

DT - Delay Time

Pump Clean Operation


Scraps and deposits that get built up in impellers inside pumps, decrease the efficiency of a motor's
performance. Through consecutive FWD/REV or ACC/DEC operations, the scraps get eliminated.
This results in extension of the pump's lifespan, prevents pre-mature pump failure and ensures
energy savings. The Pump Clean mode is initiated by a remote signal, current profile or power profile.

Flange-Type Mounting
If the space is too small, a heat sink can be
installed outside the panel. This helps reduce
heat losses inside the panel.
Payback Counter (Energy Saving Display) Load Tuning
It displays energy saving information by comparing Establishes load (current and power) curves based
the average energy efficiency for operation with and on the drive frequency, so as to make the load
without the drive. The energy saving information characteristics curve required for ‘Under Load’ and
is displayed as kWh, saved energy cost and CO2 ‘Pump Clean’ modes.
emission level.

Fire Mode Detection of Broken Pipe


When an emergency such as a fire occurs at the This function detects pipe breaks when the PID
(584mm) suction/exhaust fans, without any hardware failure operation is ON. The fault trip or a warning signal
or a critical defect, the drive continuously operates will occur if the feedback does not reach the level set
to protect other systems under the set frequency and by the user during the operation with the maximum
Side-by-Side Installation direction. output (PID maximum output or the maximum
speed set).
The size of the control board is significantly
reduced when multiple drives are installed by
(50mm) (50mm)
minimising the distance between them.
(Side-by-side installation is unavailable for 37~90kW)
Aux Motor PID Compensation Power-on Resume
In-pipe flow increases and conduit pressure decreases When the drive restarts after it was stopped due to
as the number of auxiliary motors increases. To power interruption, the drive memorises the status
2mm 2mm counter this, Aux Motor PID Compensation is used to command, frequency reference and ACC/DEC time
compensate for the pressure loss. settings upon loss of communication control. As soon as
power is resumed, 'Power-on Resume' is used to follow
the previous control command.

32 33
Features Optional

Communication Module
Built-in RS485 communication: • BACnet • Modbus-RTU • Metasys N2
Optional: LonWorks

Software Exclusive for L&T Drives


DriveConnect can be connected using USB Port or RJ45 terminal.

Remote Cable

Flow Compensation 1 2 3 3

In a system with longer pipes and a higher flow rate, a drop in pressure is often experienced. This
feature helps to compensate for the pressure drop by increasing the PID reference.
Cable 1: Optional; available for separate purchase
Cable 2: General-purpose cable
[RJ45-- 9 Pin Cable] [9 Pin-- USB Converter] [USB Cable]
Cable 3: Optional; available for separate purchase
Convert from RS485 to RS232

Optional I/O Expansion Card


Lubrication Control Level Detection
During a lubrication operation, the drive outputs When the drive is operated above or below the user
the lubrication signal through one of the output defined values i.e., beyond the set frequency and
relays when the drive receives a RUN command. The source (voltage, current) values the drive generates a
drive does not start operating until the time set at trip or activates a relay for protective operation.
‘Lubrication OP Time’ has elapsed and the Lubrication
signal is turned OFF.
Expansion I/O 1 (LTIO-EXP-H) card
This can be installed as an option with the
Damper Control Macro Setting following specifications:
If a fan and a damper are used together in a system, The Macro selection function is used to put • Digital Inputs: 2 (NPN/PNP)
the drive may be configured to operate according various application functions together in a group. • Digital Outputs: 3 (Relay)
to the damper’s operation status. During damper For applications with the Hx2000 drive, 7 Macro • Analog Input: 1 (V/I)*
operation, one of the relay outputs (Relay 1–5) may configurations are available i.e. Basic, Compressor, • Analog Output: 1 (V/I)*
be set to ‘Damper Control’ to output a signal based Supply Fan, Exhaust Fan, Cooling Tower, Circulation
on the damper’s operation status. One of the multi- Pump, Vacuum Pump and Constant Torque.
function terminal inputs may also be set ‘Damper
Open’ to receive the damper status input. The drive
Expansion I/O 2 (LTIO-EXP2-H) card
• Analog Input: 3 (V/I)*
starts operating when both the RUN command and
• Analog Output: 2 (1V & 1I)*
the 'Damper Open' signal are turned ON.

Pre-Heat Function PID Sleep and Wake-up function


Pre-heats motors by outputting direct current when It is used to put the drive on standby and restart
the motors or pumps are not in operation, in order to it using PID as per the load requirments in order to *V = 0-10 V, I = 0-20mA
prevent condensation of the motors or pumps. reduce motor losses as much as possible.

34 35
Specifications Specifications

Hx2000 with I/O Expansion card 1


Rated Input Voltage 3-phase 380 ~ 480 VAC (-15%, +10%)
I/O type Standard IO Expansion Card Total Rated Frequency 50 ~ 60 [Hz] (±5%)
DI 7 2 9
Max Output Voltage Proportional to Input Voltage

Standard Specifications
DO 5R+1T 3 9
Max Output Frequency 0 to 400Hz
AI 1V+1V/I 1V/I 3
Keypad LCD Detachable
AO 1V+1V/I 1V/I 3
DC Reactor Built-in from 37kW to 90kW
PTI 1 0 1
EMC Filter Built-in as default (C3)
PTO 1 0 1
Multi Motor Control, Built-in RTC, USB Port, HVAC Macros, Built-in PID, Lubrication Control, Motor
Pre Heat, KEB, Auto Restart, Sleep & Wake-up Function, Damper Control, Belt Broken Detection,
Features Pump Clean Mode, Flow Compensation Mode, Dry Pump Detection, Password Protection, Payback
Counter (Energy Saving on Display),
Fire Mode
Control Method V/F control, slip compensation
Hx2000 with I/O Expansion card 2 Digital command: 0.01 Hz
Frequency Setting Resolution
Analog command: 0.06 Hz (60 Hz standard)
I/O type Standard IO Expansion Card Total
Analog type: -10–10 V, 0–10 V, 0–20 mA
DI 7 0 7 Frequency Settings
Digital type: key pad, pulse train input

Control Details
DO 5R+1T 0 6 V/F Pattern Liner, squared reduction and user V/F
AI 1V+1V/I 3V/I 5
Overload Capacity Rated current of 120% for 1 minute
AO 1V+1V/I 1V + 1I 4
Torque Boost Manual torque boost, automatic torque boost 1, automatic torque boost 2
PTI 1 0 1
Output Frequency Resolution 0.01Hz
PTO 1 0 1
Accel/Decel Time 0.0 to 600.0 (sec)
Frequency Accuracy 1% of maximum output frequency
Operating Method Selectable among keypad/terminal block/communication operation
PID control, 3-wire operation, Frequency limit, Second motor function, Anti-forward and reverse,
direction rotation, Commercial transition, Speed search, Power braking, Leakage reduction, Up-
Operating Functions
Input and Output Specifications: Input Voltage Three-Phase 415V (0.75 to 90kW - ND) down operation, DC braking, Frequency jump, Slip compensation, Automatic restart, Automatic
tuning, Energy buffering, Flux braking, Energy Saving
LTVF-H4ooooBAA 0002 0004 0006 0008 0012 0016 0024 0030 0038 0045 0061 0075 0091 0107 0142 0169 7No. Programmable NPN (Sink) / PNP (Source)
Applied Motor kW 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 Function: Forward direction operation, Reset, Emergency stop, Multi step speed, frequency-high/
(kW) HP 1.5 2.2 3.7 5.5 7.5 10 15 20 25 30 40 50 60 75 100 120
Multi-function terminal med/low, Reverse direction operation, External trip, Jog operation, Multi step acc/dec, Second
P1-P7 motor selection, DC braking during stop, Frequency increase, 3-wire, Select acc/dec/stop, MMC
Rated Input Interlock, Frequency reduction, Fix analog command frequency, Transition from PID to general

Operation
Current ND 2 4 6 8 12 16 24 30 38 45 61 75 91 107 142 169
[A] operation Pre Heat, Pump Cleaning, RTC (Time Event)
Rated Capacity Analog input 2 No., -10 ~ 10 Vdc : 1 No. 0 ~ 20 mA / -10 ~ 10Vdc : 1 No.
Output 1.9 3 4.5 6.1 9.1 12.2 18.3 23 29 34.3 46.5 57.1 69.4 82 108.2 128.8
[kVA]
Ratings Pulse Train input 0 to 32 kHz
Output
0 ~ 400 [Hz]
Frequency Multi-function open
1 No., Less than DC 26 V, 50 mA
Output Voltage collector terminal
3-phase 380 ~ 480V
[V]
Fault output and drive operation N.O.: Less than AC 250 V 2A, DC 30 V, 3A
Available Fault Signal relay 1 No.
Voltage [V]
3-phase 380 ~ 480 VAC (-15%, +10%) status output N.C.: Less than AC 250 V 1A, DC 30 V 1A
Output
Input 4 No., Less than AC 250 V, 5 A
Input
Frequency
50 ~ 60 [Hz] (±5%) Multi-function relay
Ratings Less than DC 30 V, 5 A
Rated
Current ND 2.2 3.6 5.5 7.5 12.2 17.5 26.5 33.4 42.5 50.7 69.1 69.3 84.6 100.1 133.6 160
Analog output 2 No., 0 ~ 10 Vdc / 0 ~ 20 mA : 1 No. 0 ~ 10 Vdc : 1 No.
[A] Pulse Train output 0 to 32 kHz
RS-485 Communication Built-in BACnet, Modbus-RTU, Metasys N2 as standard

36 37
Specifications Connection Diagram

Rated Input Voltage 3-phase 380 ~ 480 VAC (-15%, +10%)


0.75 to 90kW
Over-current trip, Trip caused by external signals, ARM short-circuit current trip, Overheat trip, Pipe
broken trip, Input open-phase trip-Ground trip, Motor overheat trip, IO board connection trip, No
motor trip, Parameter write trip, Emergency stop trip, Command loss trip, External memory error,
Protective Functions

Trip CPU watchdog trip, Motor under-load trip, Overvoltage trip, Temperature sensor trip, Drive overheat,
Option trip, Output open-phase trip, Drive overload trip, Fan trip, Low voltage trip during operation,
Low voltage trip, Analog input error, Motor overload trip, Keypad command loss trip, Damper trip,
Level detect trip, All auxiliary motor failure trip, Pump clean failure (fault)
Command loss trip alarm, overload alarm, normal load alarm, drive overload alarm, fan operation
Alarm alarm, resistance braking rate alarm, Capacitor life alarm, Pump Clean alarm, Fire Mode Alarm, LDT
Alarm.
Momentary Power Loss Ride Less than 8 ms: Continue Operation (must be within the rated input voltage and rated output range)
through More than 8 ms: Auto restart operation
Indoors. Prevent contact with corrosive gases, inflammable gases, oil stains, dust, and other
Area of Use
pollutants (Pollution Degree 2 Environment)
Type of Cooling Forced fan cooling structure
Structure & Environment

Enclosure Type IP20 / UL Open(default), UL Enclosed Type 1(option)


Ambient Temperature -10oC to 40oC
Storage Temperature -20C ~ 65°C
Application Humidity Below 95% RH of relative humidity (with no dew formation)
Conformal Coating complying to IEC 60721-3-3
PCB Protection
class 3C2 (max) and class 3C3 (avg)
Altitude 1,000m or below
Vibration 9.8m/sec2 (1.0G) or below
Global Compliance CE, RoHS, UL (Plenum Rated)

38 39
Control Circuit Terminal Power Circuit Terminal

0.75~30kW(3-Phase)

Classification Symbol Name Description


It can be used by setting multifunctional input. Default values from the factory are as
follows:
• P1: Fx
• P2: Rx
Multifunctional Input
P1~P7 • P3: BX
Selection of 1~7 Terminal
• P4: RST
contact points • P5: Speed-L
• P6: Speed-M
• P7: Speed-H

CM Sequence Common Terminal Common terminal of contact point input and analog I/O terminal
Input Terminal Details

Power for analog frequency setting:


Power Terminal • Max. output voltage: 12V
VR
for Frequency Setting • Max. output current: 12mA
• Volume resistivity: 1~10kΩ
Frequency is set depending on the voltage supplied to V1 terminal.
Frequency Setting(Voltage)
V1 • Unipolar: 0~10V(Max. 12V)
Terminal Terminal Mark Name Description
• Bipolar: -10~10V(Max. ±12V)
Analog Input
Frequency is set depending on the current capacity supplied to I2 R(L1)/S(L2)/T(L3) AC Power Input Terminal It connects to commercial AC power
terminal. V2 can be used by selecting analog voltage/current input + DC voltage terminal:
terminal setting switch (SW4). P1+ +DC Link Terminal
Frequency Setting This terminal is used to connect an exterior DC reactor
I2 • Input current: 0~20mA
(Current/Voltage) Terminal
• Max. input current: 24mA P2+ +DC Input Terminal DC(+) is connected when DC is input via drive power
• Input resistance 249Ω
DC voltage terminal:
• Input voltage: 0~10V N- -DC Link Terminal
DC(-) is connected when DC is input via drive power
Frequency is set as 0~32kHz.
Pulse Train TI Frequency Setting Terminal B2 Braking resistance connection terminal It connects to Braking resistanceNote 2
Low Level : 0~0.8V, High Level : 3.5~12V
U/V/W Motor output terminal It connects to 3-phase induction motor
As a multifunctional output signal or pulse output, one of the following is
chosen: Output frequency, output current, output voltage and DC voltage.
Multifunctional
DC 26V, 50mA or below If you want to run the drive using DC input, connect DC input to P2(+) and N(-) terminal
Q1 (Open Collector) Output/
Pulse output terminal Note 1: Short Bar should be removed when wiring DC Reactor
Pulse Output Terminal
• Output frequency: 0~32kHz Note 2: In case of using with an external DC reactor, only P2(+) terminal connection is allowed
In case of not using with an external DC reactor, P1(+) or P2(+) terminal connection is allowed
• Output voltage: 0~12V

EG Common Terminal • Common ground terminal for external power of open collector

• Max. output current: 100mA


Selection of 24 24V Power Terminal *
contact points
• Do not use external 24V except for PNP-mode terminal block 37~90kW(3-Phase)
When power is cut-off to protect the product, signals or multifunctional
Output/Communication Terminal Details

signals are output.


Abnormal Signal (N.O. : AC250V 2A or below, DC 30V 3A or below
A1/C1/B1 Output/Multifunctional N.C. : AC250V 1A or below and DC 30V 1A or below)
Output Terminal • At abnormal state: A1-C1 connected (B1-C1 disconnected)
• At normal state: B1-C1 connected (A1-C1 disconnected)
• Factory default value: Frequency

Multifunctional Relay Output A Multifunctional output terminal such as signals at operation is defined
A2/C2 ~ A5/C5
Contact Point and used.(AC 250V 5A or below and DC 30V 5A or below)

One of the following is chosen and output: Output frequency, output


current, output voltage and DC voltage. The following voltage/current
output can be chosen by selecting analog voltage/current
output terminal setting switch (SW5).
Voltage/Current Output
AO1 • Output voltage: 0~10V
Terminal
Analog Output • Max. output voltage/current: 12V, 10mA
• Output current: 0~20mA
• Max. output current: 20mA
• Factory default value: Frequency

AO2 Voltage Output Terminal 0 ~ 10 Vdc Terminal Mark Name Description

Frequency is set as 0~32kHz. R(L1)/S(L2)/T(L3) AC Power Input Terminal It connects to commercial AC power
Pulse Train T0 Frequency Setting Terminal
Low Level : 0~0.8V, High Level : 3.5~12V + DC voltage terminal:
P2+ +DC Link Terminal
DC(+) is connected when DC is input via drive power
Communication
S+/S-/SG RS485 Signal Input Terminal RS485 signal line
Terminal +DC voltage terminal
P3+ +DC Input Terminal
This terminal is used to connect DBU
DC voltage terminal:
N- -DC Link Terminal
DC(-) is connected when DC is input via drive power
U/V/W Motor output terminal It connects to 3-phase induction motor

Note: * Available only when used in PNP mode If you wish to start the drive using DC input, connect it to the P2(+), N(-) terminal

40 41
Dimensions & Weight

Input Voltage Drive Model W (mm) H (mm) D (mm) Weight (kg)

LTVF-H40002BAA 160 232 181 3.3

LTVF-H40004BAA 160 232 181 3.3

LTVF-H40006BAA 160 232 181 3.3

LTVF-H40008BAA 160 232 181 3.3

LTVF-H40012BAA 160 232 181 3.3

LTVF-H40016BAA 160 232 181 3.3

LTVF-H40024BAA 160 232 181 3.4

LTVF-H40030BAA 180 290 205.3 4.6

Three-Phase 415 V LTVF-H40038BAA 180 290 205.3 4.8

LTVF-H40045BAA 220 350 223.2 7.5

LTVF-H40061BAA 220 350 223.2 7.5

LTVF-H40075BAA 275 450 284 26

LTVF-H40091BAA 325 510 284 35

LTVF-H40107BAA 325 510 284 35

LTVF-H40142BAA 325 550 309 43

LTVF-H40169BAA 325 550 309 43

Note: The above drawings are solely for reference. Please refer to the technical manual for more details.

42 43
Compact, lightweight, easy to install, operate and service, the Cx2000 is perfectly suited for
conveyors, pumps, fans and textile machinery. It is engineered to keep your machine operating at Features
optimum efficiency, even in the hot, humid and dusty conditions that characterise India's industrial
environment. Ideal for replacement of conventional motor starters, where Cx2000 will provide
better motor protection features with communication compatibility. User Convenience
through Simple Operation
Integrated Potentiometer
• Possible to add reference from keypad and external signal
• Provides external potentiometer for easier frequency control
• Additional 0~5V analog input for frequency control
• Useful in DRAW Mode
• Useful as auxiliary reference

Easy Fan Maintenance


You can easily replace a fan without opening the drive cover.

Main Features Side-by-Side Installation


The panel size can be significantly reduced thanks to the
n Range: 0.1kW to 11kW Cx2000's side-by-side installation.

n V/F, slip compensation


n Integrated potentiometer Applications
n Built-in PID
n Built-in braking chopper n OEM Machines
n Plastic & Textile Machines
n Torque boost for forward and KEB for Safe Operating Stop
reverse direction n Food & Packaging Machines in the Event of Power Failure
n Hardware base block n Conveyors By using the regenerated power from the decelerating
load, the KEB function automatically protects the
n Built-in 24V power source n AHU Control machine by providing safe (controlled) braking in case
of a power outage.
n RPM display on keypad n Fan

n KEB for safety stop n Pump

n Auto tuning of motor n Crane Control LT / CT


n Conformal Coating complying to n Machine Tool
IEC 60721-3-3 class 3C2 (max) Compliance with Safety Requirements
n Treadmill
and class 3C3 (avg) • If a machine needs safe standstill functionality in case of
n Insense Stick Machine emergency, the connection of SA, SB, and SC terminals that
n Built-in RS485 Modbus RTU n
is shorted normally will be opened to block the drive output.
Textile Machine
Communication
• Easy to comply with safety requirements at the system level
by adding safe input functions complying with EN ISO
13849-1 Pld and EN61508SIL2 [EN60204-1, stop category 0]

44 45
Features Features

DIGITAL KEYPAD DOP-50

Delta Frequency:
Frequency 30Hz Acceleration & Deceleration control
• Useful in standalone as well as process applications
10Hz • Acc-Dec time based on Delta frequency is normally used
in process lines where gear ratio between one station to
External Keypad: another station is different.
5 7 12 Time • In applications where there are multiple drives running
Cx2000 has a model without built-in keypad for which at different frequencies and application demands all the
external LED keypad (LTOP-DOP-50) is used which comes RUN cmd drives reach the prescribed frequency at the same
with default 3m cable. time, delta frequency is used.
5 sec 5 sec • Settable from 0.00 sec to 6000 sec

Note:
1) For selection of Cx2000 model without keypad please refer page no. 5 "Model type and Selection"
2) For 7.5kW (ND) & 11kW (ND) ratings, there is a facility to connect the external keypad directly to
the standard drive.

V2 V1

Draw Mode
Built-in PID • It is a kind of open loop tension control that uses the
AC Drive Output
speed difference of motor running under main frequency
• Useful in Pump, AHU applications to maintain command to keep material’s tension steady in between
process variables (Flow, Pressure & Temperature) • Very useful for precise control of tension, linear velocity, etc.
as per required set-point. Process
Water IN • Settable manually through keypad potentiometer or
Feedback M
• Available with sleep & wake-up functions Signal analog inputs
• No need for external PID Controller
Cooling Tower • Applications like: wire drawing, pipe plants, etc.

Water OUT
Transducer Draw Line Speed
Setting Setting

2nd Motor Operation PLC

Built-in RS485 Modbus RTU


• Useful when drive operates 2 motors connected to
two different types of loads • Easy Integration with 3rd party devices
• Single AC Drive can maintain 2 motor parameters • No extra cost of communication card
1 2 3 16
with different Accel / Deccl parameter setting. It • Maximum number of slaves: 16
does not drive 2 motors at the same time. • Grouped parameters to read & write
• For isolated operation of motors one VFD can be with a single command
used in place of 2

RS485 MODBUS RTU

46 47
Specifications Specifications

Input and Output Specifications: Input Voltage Single-Phase 230V (0.1 to 2.2kW - HD)
LTVF-C1 oooo BAA 0001 0002 0003 0005 0008 0011
Single-Phase 230V Three-Phase 230V Three-Phase 415V
Applicable HP 0.12 0.25 0.5 1 2 3
Range
Motor1) kW (HD) 0.1 0.2 0.4 0.75 1.5 2.2
0.1 to 2.2 kW (HD) 0.2 to 11 kW (ND) 0.75 to 11 kW (ND)
Rated Capacity [kVA] (HD) 0.3 0.5 1.0 1.9 3.0 4.2
Rated Current [A]2) (HD) 0.8 1.4 2.5 5.0 8.0 11 Enclosure Type IP20
Output Ratings
Max. Output Frequency 400 [Hz]3) Overload Capacity HD: 150% for 1min; ND: 110% for 1min

Standard Specifications
Max. Output Voltage [V] Three-Phase 200 ~ 240V4)
Max Output Voltage Proportional to Input Voltage
Rated Voltage [V] Single-Phase 200 ~ 240 VAC (-15% ~ +10%)
Max Output Frequency 0 to 400Hz
Input Ratings Rated Current2) [A] 1.4 2.8 5.5 11 14.1 24
Rated Voltage 200 to 240V 1/3-phase (-15%/+10%)
Rated Frequency 50 ~ 60 [Hz] (+5%)
380 to 480V 3-phase (-15%/+10%)
Cooling Type Natural Cooling Forced Cooling
Rated Frequency 50/60Hz (-5/+5%)
Keypad Built-in, Without keypad option available
Input and Output Specifications: Input Voltage Three-Phase 230V (0.2 to 11kW - ND) Braking Chopper Built-in for entire range
LTVF-C2 oooo BAA 0001 0002 0003 0006 0010 0012 0018 0030 0040 Control Method V/F, Slip Compensation
[HP] 0.12 0.25 0.5 1 2 3 5 7.5 10 Starting Torque 150% at 3 Hz in V/F
HD
Applicable [kW] 0.1 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 Frequency Control Range 0.01 to 400Hz for V/F
Motor1) [HP] 0.25 0.5 1 1.5 3 4 5.4 10 15 Frequency Precision Setting Digital command: 0.01Hz
ND
Analog command: 0.03Hz (Max. frequency: 60Hz)

Control Details
[kW] 0.2 0.4 0.75 1.1 2.2 3.0 4.0 7.5 11.0

Rated Capacity HD 0.3 0.5 1.1 1.9 3.0 4.2 6.1 9.1 12.2 Frequency Setting Analog type: 0 ~ 10[V], 0 ~ 20[mA]
[kVA] ND 0.4 0.7 1.3 2.4 3.8 5.2 7.6 12.1 16.3 Digital type: Keypad, Panel potentiometer
HD 0.8 1.4 2.5 5.0 8.0 11.0 16.0 24.0 32.0 Output Frequency Resolution 0.01Hz
Output Ratings Rated Current [A]2)
ND 1.1 1.8 3.1 6.3 10.0 12.0 18.0 30.0 40.0 V/F pattern Linear, squared, user V/F
Max. Output Frequency 400 [Hz]3) Accel/Decel Time 0.0 to 6000 Sec
Max. Output Voltage [V] Three-Phase 200 ~ 240V4)
Braking Torque Continuous Regeneration Torque 20% (150% with DBR)
Rated Voltage [V] Three-Phase 200 ~ 240 VAC (-15% ~ +10%)
Features Built in PID, RPM display, 2nd motor operation, easy maintenance of fan, built-in safety
Rated Current [A]2) HD 0.7 1.5 2.0 5.8 7.5 11.0 18.9 22.1 28.6
Input Ratings circuit, draw mode, inbuilt 24V power source, brake control, auto tuning, KEB
ND 1.1 1.9 3.9 7.3 10.8 13.9 24 28.6 41.2
Over voltage, low voltage, over current, short circuit, ground current detection, inverter
Rated Frequency 50 ~ 60 [Hz] (+5%)
Faults overheat, motor overheat, input and output phase loss, overload protection, loss of
Cooling Type Natural Cooling Forced Cooling frequency command, hardware fault, cooling fan trip, brake error.

Protection
Alarm Stall prevention, overload
Input and Output Specifications: Input Voltage Three-Phase 415V (0.75 to 11kW - ND) Momentary Power Loss Ride Through Below 16 msec: Continuous operation
Above 16 msec: Auto restarting
LTVF-C4 oooo BAA 0002 0003 0005 0007 0010 0016 0023 DI 5 (Programmable NPN/PNP)
[HP] 0.5 1.0 2.0 3.0 5.0 7.5 10.0
HD DO 1 (Programmable NO/NC)
Applicable [kW] 0.4 0.75 1.5 2.2 3.7 5.5 7.5
AI 1 (4-20mA / 0 to 10Vdc)
Motor1) [HP] 1 1.5 3 4 5.4 10 15
ND AO 1 (0 to 10Vdc)

Interface
[kW] 0.75 1.1 2.2 3.0 4.0 7.5 11.0
HD 1.0 1.9 3.0 4.2 6.1 9.1 12.2
Safety I/P 2, complying with EN ISO 13849-1 Pld and EN61508SIL2 [EN60204-1, stop category 0]
Rated Capacity
[kVA] ND 1.2 2.4 3.8 5.2 7.6 12.1 16.3 Communication RS485 Modbus RTU
HD 1.25 2.5 4.0 5.5 8.0 12.0 16.0 Potentiometer Integrated
Output Ratings Rated Current [A]2)
ND 2.0 3.1 5.1 6.9 10.0 16.0 23.0 Area of Use Indoors. There shall not be corrosive air, combustible gas, oil mist, dust
Max. Output Frequency 400 [Hz]3) Ambient Temperature -10oC to 50oC for HD, -10oC to 40oC for ND
Max. Output Voltage [V] Three-Phase 380 ~ 480V4) Storage Temperature -20oC to 65oC
Environment

Rated Voltage [V] Three-Phase 380 ~ 480 VAC (-15% ~ +10%)


PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C2 (max) and class 3C3 (avg)
Rated Current [A]2) HD 1.8 3.2 4.4 6 10.4 11.0 14.4
Input Ratings Application Humidity Below relative humidity 95% RH (no condensation)
ND 2.1 4.3 5.9 8.1 14 14.7 21.9
Altitude Below 1000m
Rated Frequency 50 ~ 60 [Hz] (+5%)
Cooling Type Natural Cooling Forced Cooling
Vibration 5.9m/sec2 (0.6G)
Global Compliance CE, UL, RoHS
Note 1) - Indicates the maximum applicable motor capacity when using a 4-pole standard motor. Note 2) - When carrier frequency setting (H39) is 6kHz or less.
Note 3) - The max. frequency setting range can be 120Hz when H40 is set to 3 (Sensorless vector control). Note 4) - The maximum output voltage cannot be higher than the input voltage and it can be programmable below input voltage.

48 49
Dimensions & Weights

Input Voltage Drive Model W (mm) H (mm) D (mm) Weight (kg)


LTVF-C10001BAA 68 128 93 0.55
Single-Phase 230 V LTVF-C10002BAA 68 128 93 0.55
LTVF-C10003BAA 68 128 128 0.8
LTVF-C20002BAA 68 128 93 0.55
LTVF-C20001BAA 68 128 93 0.55
Three-Phase 230 V
LTVF-C20003BAA 68 128 128 0.8
LTVF-C20006BAA 68 128 128 0.8
LTVF-C40002BAA 68 128 128 0.8
Three-Phase 415 V
LTVF-C40003BAA 68 128 128 0.8

IP66
Input Voltage Drive Model W (mm) H (mm) D (mm) Weight (kg)
LTVF-C10005BAA 100 128 130 1.22
Single-Phase 230 V LTVF-C10008BAA 100 128 145 1.42
LTVF-C10011BAA 140 128 145 1.97
LTVF-C20010BAA 100 128 130 1.22
Three-Phase 230 V LTVF-C20012BAA 100 128 145 1.42
LTVF-C20018BAA 140 128 145 1.97
LTVF-C40005BAA 100 128 130 1.22
Three-Phase 415 V LTVF-C40007BAA 100 128 145 1.42
LTVF-C40010BAA 140 128 145 1.97

Input Voltage Drive Model W (mm) H (mm) D (mm) Weight (kg)


LTVF-C20030BAA 160 232 141 3.3
Three-Phase 230 V
LTVF-C20040BAA 160 232 141 3.3
LTVF-C40016BAA 160 232 141 3.3
Three-Phase 415 V
LTVF-C40023BAA 160 232 141 3.3

Note: The above drawings are solely for reference purposes. Please refer to the technical manual.

50
50
Sx2000 IP66 Drive provides protection against harsh environmental conditions by restricting entry
IP66 Specifications
of foreign substances such as fine dust and high – pressure water spray.
Satisfies NEMA standard type 4X for indoor use.
What is IP-XX?
IP-xx denotes the degree of dust and water resistance, it is abbreviation of the IEC standard 60529 for Ingress Protection to the
enclosures.

IP - 6 6

First Digit - SOLIDS Second Digit - LIQUIDS


Protected against access to hazardous parts with a wire of 1mm Ø
Protected against powerful water jets from any direction
No ingress of dust - dust tight

Front Cover Removed

Power Disconnector Switch

ON Keypad & Display

OFF

Control Terminal Block


Main Features

n Range: 0.75kW to 22kW (HD) Input/Output Power


Terminal Block
n V/f, Sensorless vector control,
Slip Compensation Applications Ground Terminals

n Starting Torque of 150% at 3Hz Cable Glands


for V/f, 200% at 0.5 Hz for
n Textile
vector control n Pharma
n Built-in Brake Control n Food and Beverages
User Sequence – PLC functionality Input and output specification: Input Voltage Three-Phase 415V (0.75 to 22kW)
n n Ceramic
n Component life monitor n Waste Water Treatment LTVF-S4 oooo XAA 0001 0003 0004 0006 0009 0012 0016 0024 0030 0039 0045

n Inbuilt PID HP 0.5 1.0 2.0 3.0 5.5 7.5 10.0 15.0 20.0 25.0 30.0
n Bottling plant Applicable
Motor
Heavy
Duty [HD] kW 0.4 0.75 1.5 2.2 4.0 5.5 7.5 11.0 15.0 18.5 22.0
n No motor detection n Machine tool Capacity
Heavy Duty [HD] 1.0 1.9 3.0 4.2 6.5 9.1 12.2 18.3 22.9 29.7 34.3
[kVA]
n Conformal coating complying
Output Rated
Heavy Duty [HD] 1.3 2.5 4.0 5.5 9.0 12.0 16.0 24.0 30.0 39.0 45.0
to IEC 60721-3-3 class 3C2 (max) Rating Current [A]

and class 3C3 (avg) Frequency [Hz] 0~400Hz (IM Sensorless : 0~120[Hz])
Voltage [V] 3-phase 380~480V
n Built-in RS 485 Modbus RTU Voltage [V] 3-phase 380~480VAC (-15% ~ +10%)

communication Input
Frequency
50~60Hz (±5%)
[Hz]
Rating
n Built-in braking chopper Rated
Heavy Duty [HD] 1.1 2.4 4.2 5.9 9.8 12.9 17.5 26.5 33.4 43.6 50.7
Current [A]

52 53
IP66 Specifications IP66 Dimensions & Weights

Overload Capacity HD: 150% for 1min


Standard Specifications

Max Output Voltage Proportional to Input Voltage


Max Output Frequency 0 to 400Hz (Sensorless: 0 to 120Hz)
Rated Voltage 380 to 480V Three-phase (-15%/+10%)
Rated Frequency 50/60Hz (-5/+5%)
Keypad Built-in LED
Braking Chopper Built-in
Control Method V/F, Sensorless Vector Control, Slip Compensation
Starting Torque 200% at 0.5Hz for Sensorless Control & 150% at 3Hz for V/F
Torque Boost Manual torque boost, Automatic torque boost
Frequqncy Accuracy 1% of maximum output frequency
Frequency Control Range 0.01 to 400Hz for V/F , 0 to 120Hz for Sensorless Vector Control
Control Details

Frequency Setting Analog type: - 10 to 10V, +0 to 10[V], 4 to 20[mA],


Digital type: Keypad, pulse train input
Output Frequency Resolution 0.01Hz
V/F pattern Linear, squared, user V/F
Accel/Decel Time 0.0 to 6000 Sec
Braking Torque Continuous Regeneration Torque 20% (150% with DBR)
Features Multi keypad, peer-to-peer communication to share I/Os, user sequence, inbuilt PID, component life
monitor, no motor detection, auto tuning, Brake Control, KEB, Flying start, Safety Function
Over current trip, External signal trip, ARM short circuit current trip, Over heat trip, Ground trip,
Motor over heat trip, I/O board link trip, No motor trip, Parameter writing trip, Emergency stop trip,
Command loss trip, External memory error, CPU watchdog trip, Motor normal load trip, Input Voltage Drive Cat. No. W1 (mm) W2 (mm) H1 (mm) H2 (mm) D1 (mm) D2 (mm) Weight (kg)
Faults
Over voltage trip, Temperature sensor trip, Inverter over heat, Option trip, Output imaging trip, LTVF-S40001XAA 180 170 256.6 245 174.2 188.2 3.7
Protection

Inverter overload trip, Fan trip, Pre-PID operation failure, External break trip, Low voltage trip during LTVF-S40003XAA 180 170 256.6 245 174.2 188.2 3.7
operation, Low voltage trip, Safety A (B) trip, Analog input error, Motor overload trip
LTVF-S40004XAA 220 204 258.8 241 201 215 5.3
Alarm Command Loss trip alarm, overload alarm, normal load alarm, inverter overload alarm, fan operation
LTVF-S40006XAA 220 204 258.8 241 201 215 5.5
alarm, resistance braking alarm, number of corrections on rotor tuning error
LTVF-S40009XAA 220 204 258.8 241 201 215 5.6
Instantaneous Interruption Heavy load less then 15ms: continue operation (must be within the rated input voltage and rated
Three-Phase 415 V LTVF-S40012XAA 250 232 328 308 227.2 241.2 8.8
output range) Heavy load more then 15ms: auto restart operation
LTVF-S40016XAA 250 232 328 308 227.2 241.2 8.9
DI 5 (Programmable NPN/PNP)
LTVF-S40024XAA 260 229 399.6 377 245.5 259.6 9.6
DO 1 (Programmable NO/NC) + 1 TR LTVF-S40030XAA 260 229 399.6 377 245.5 259.6 9.8
AI 1Nos: 0 to 10V & 1 Nos: 0 to 10V / 4 to 20mA LTVF-S40039XAA 300 270.8 460 436.5 250 264 12.4
Interface

AO 1 (4-20mA / 0 to 10Vdc) LTVF-S40045XAA 300 270.8 460 436.5 250 264 12.4

Pulse Train 1 I/P & 1 O/P ( 0 to 32Khz)


Built-in PID 1
Communication Built-in RS485 Modbus RTU
Safety I/P 2, complying with EN ISO 13849-1 Pld and EN61508SIL2 [EN60204-1, stop category 0]
Option

Expansion Card 3DI (PNP / NPN), 2DO (R), 2AI (-10 to 10V), (0 to 10V / 0 to 20mA), 1AO (0 to 10V / 0 to 20mA)
Communication Card CANopen, Profibus DP, Modbus TCP / Ethernet IP
Cooling Type Forced fan cooling structure
Area of Use Prevent contact with corrosive gases, inflammable gases, oil stains, and other pollutants (Pollution
Degree 3 Environment)
Enclosure Type IP66 (NEMA 4X Indoor Only)
Environment

Ambient Temperature -10 to 40oC for HD


Storage Temperature -20oC to 65oC
PCB Protection Conformal coating complying to IEC 60721-3-3 class 3C2(max) and 3C3(avg)
Altitude Below 1000m
Vibration 9.8m/sec2 (<1G)
Global Compliance CE, UL, RoHS
Note: The above drawings are solely for reference purposes. Please refer to the technical manual.

54 55
Accessories for AC Drives Accessories for AC Drives
Flange Options
Suitable for Drive Description CAT No.
Drive
Cx2000 LED Digital Operator with 3m cable LTOP-DOP-50 Drive CAT No Frame Size Flange CAT Nos Description
Model
LCD Digital Operator LTOP-DOP-200
LTVF-S10003BAA
LED Digital Operator with 3m cable for Sx2000 LTOP-DOP-150
LTVF-S20003BAA
I/O Expansion Card for Sx2000 (3DI, 2DO, 2AI, 1AO) LTIO-EXP-S.
Sx2000 Sx2000 LTVF-S20006BAA FR1 LTFM-FR1-S FLANGE FOR S1:3A / S2:3~6A / S4:2~3A
CANOpen Communication card LTCI-CAN-S
LTVF-S40002BAA
Profibus-DP Communication card LTCI-PDP-S.
LTVF-S40003BAA
Ethernet IP - Modbus TCP Communication card LTCI-ETH-S
LTVF-S10006BAA
LCD Digital Operator LTOP-DOP-200
LTVF-S10010BAA
I/O Expansion Card 1 for Fx2000 LTIO-EX1-F
LTVF-S20010BAA
I/O Expansion Card 2 for Fx2000 LTIO-EX2-F Sx2000 FR2 LTFM-FR2-S FLANGE FOR S1:6~10A / S2:10~12A / S4:5~7A
LTVF-S20012BAA
Synchronization Option Card LTCN-SYN-F
LTVF-S40005BAA
Position control option card for Fx2000 LTCN-PCN-F
LTVF-S40007BAA
Fx2000 Incremental card for Open collector and Line Driver Encoder LTEN-INC-F
LTVF-S10012BAA
Profibus-DP Communication Interface card LTCI-PDP-F
Sx2000 LTVF-S20018BAA FR3 LTFM-FR3-S FLANGE FOR LTVF-S10012/S20018/S40010BAA
Application Development PLC Option card LTAD-PLC-F LTVF-S40010BAA

CANOpen Communication Interface card LTCI-CAN-F LTVF-S20030BAA

DeviceNet Communication Interface card LTCI-DEN-F LTVF-S20040BAA


Sx2000 FR4 LTFM-FR4-S FLANGE FOR LTVF-S20030~40/S40016~0023BAA
Ethernet IP/Modbus TCP Communication Interface card LTCI-ETH-F LTVF-S40016BAA

PLL option card for Fx2000 LTCN-PLL-F LTVF-S40023BAA

I/O Expansion Card 1 for Hx2000 LTIO-EXP-H LTVF-S20056BAA


Hx2000
Sx2000 LTVF-S40030BAA FR5 LTFM-FR5-S FLANGE FOR LTVF-S20056/S40030~0038BAA
I/O Expansion Card 2 for Hx2000 LTIO-EXP2-H
LTVF-S40038BAA
Dynamic Braking Unit for 11 - 15kW LTDBU-0150-4
LTVF-S20069BAA
Dynamic Braking Unit for 18.5 - 22kW LTDBU-0220-4

DBU for Sx2000 LTVF-S40044BAA FR6 LTFM-FR6-S FLANGE FOR LTVF-S20069/S40044~0058BAA


Dynamic Braking Unit for 30 - 37kW LTDBU-0370-4
Sx2000, Fx2000
LTVF-S40058BAA
Dynamic Braking Unit for 45 - 55kW LTDBU-0550-4
Sx2000 LTVF-S40075BAA FR7 LTFM-FR7-S FLANGE FOR LTVF-S40075BAA
Dynamic Braking Unit for 75kW LTDBU-0750-4
LTVF-S40091BAA
Dynamic Braking Unit for 220 - 375kW LTDBU-2200-4
Sx2000 FR8 LTFM-FR8-S FLANGE FOR LTVF-S40091~0107BAA
LTVF-S40107BAA

LTVF-S40142BAA
Sx2000 FR9 LTFM-FR9-S FLANGE FOR LTVF-S40142~0169BAA
LTVF-S40169BAA

LTVF-F40004CAA

LTVF-F40006CAA
Fx2000 FR1 LTFM-FR1-F FLANGE FOR LTVF-F40004~0012CAA
LTVF-F40008CAA

LTVF-F40012CAA

LTVF-F40016CAA
Fx2000 FR2 LTFM-FR2-F FLANGE FOR LTVF-F40016~0024CAA
LTVF-F40024CAA

56 57
Accessories for AC Drives Peripheral Devices
Flange Options DBU & DBR Selection Chart for Cx2000, Sx2000 & Fx2000
Motor Specifications of the Breaking Specifications for
Inverter Capacity (1) Dynamic Braking Unit
LTVF-F40030CAA (HD) Resistor when ED is 5% Crane / Hoist *(2)
Fx2000 FR3 LTFM-FR3-F FLANGE FOR LTVF-F40030~0039CAA kW
LTVF-F40039CAA DBU Cat. No. Qty Resistor [Ω] Qty Resistor [Ω] Qty
LTVF-C40002BAA 1200 Ω - 100 W 1 - -
LTVF-F40045CAA 0.4
Fx2000 FR5 LTFM-FR5-F FLANGE FOR LTVF-F40045~0061CAA LTVF-S40002BAA 1200 Ω - 100 W 1 - -
LTVF-F40061CAA LTVF-C40003BAA 600 Ω - 150 W 1 - -
LTVF-S40003BAA 0.75 600 Ω - 150 W 1 600 Ω - 450 W 1
LTVF-F40075CAA
LTVF-F40004CAA 600 Ω - 150 W 1 600 Ω - 450 W 1
Fx2000 LTVF-F40091CAA FR6 LTFM-FR6-F FLANGE FOR LTVF-F40075~0110CAA LTVF-C40005BAA 300 Ω - 300 W 1 - -
LTVF-S40005BAA 1.5 300 Ω - 300 W 1 300 Ω - 900 W 1
LTVF-F40110CAA
LTVF-F40006CAA 300 Ω - 300 W 1 300 Ω - 900 W 1
LTVF-F40152CAA LTVF-C40007BAA 200 Ω - 400 W 1 - -
Fx2000 FR7 LTFM-FR7-F FLANGE FOR LTVF-F40152~0183CAA
LTVF-F40183CAA LTVF-S40007BAA 2.2 200 Ω - 400 W 1 200 Ω - 1200 W 1
LTVF-F40008CAA 200 Ω - 400 W 1 200 Ω - 1200 W 1
LTVF-F40223AAA
LTVF-F40012CAA 3.7 130 Ω - 600 W 1 130 Ω - 2000 W 1
LTVF-F40264AAA LTVF-C40010BAA 130 Ω - 600 W 1 - -
4
Fx2000 FR8 LTFM-FR8-F FLANGE FOR LTVF-F40223~0370AAA LTVF-S40010BAA 130 Ω - 600 W 1 130 Ω - 2000 W 1
LTVF-F40325AAA Built-in
LTVF-C40016BAA 85 Ω - 1000 W 1 - -
LTVF-F40370AAA LTVF-S40016BAA 5.5 85 Ω - 1000 W 1 85 Ω - 3000 W 1
LTVF-F40016CAA 85 Ω - 1000 W 1 85 Ω - 3000 W 1
LTVF-F40432AAA
Fx2000 FR9 LTFM-FR9-F FLANGE FOR LTVF-F40432~0547AAA LTVF-C40023BAA 60 Ω - 1200 W 1 - -
LTVF-F40547AAA LTVF-S40023BAA 7.5 60 Ω - 1200 W 1 60 Ω - 4000 W 1
LTVF-F40024CAA 60 Ω - 1200 W 1 60 Ω - 4000 W 1
LTVF-H40002BAA
LTVF-S40030BAA 40 Ω - 2000 W 1 40 Ω - 6000 W 1
11
LTVF-H40004BAA LTVF-F40030CAA 40 Ω - 2000 W 1 40 Ω - 6000 W 1
LTVF-S40038BAA 30 Ω - 2400 W 1 30 Ω - 8000 W 1
LTVF-H40006BAA 15
LTVF-F40039CAA 30 Ω - 2400 W 1 30 Ω - 8000 W 1
Hx2000 LTVF-H40008BAA FR4 LTFM-FR4-H FLANGE FOR LTVF-H40002~0024BAA LTVF-S40044BAA 20 Ω - 3600 W 1 20 Ω - 10000 W 1
18.5
LTVF-F40045CAA 20 Ω - 3600 W 1 20 Ω - 10000 W 1
LTVF-H40012BAA
LTVF-S40058BAA 20 Ω - 3600 W 1 20 Ω - 12000 W 1
LTVF-H40016BAA 22
LTVF-F40061CAA 20 Ω - 3600 W 1 20 Ω - 12000 W 1

LTVF-H40024BAA LTVF-S40075BAA LTDBU-0370-4 1 16.9 Ω - 5000 W 1 16.9 Ω - 17000 W 1


30
LTVF-F40075CAA LTDBU-0370-4 1 16.9 Ω - 5000 W 1 16.9 Ω - 17000 W 1
LTVF-H40030BAA
LTVF-S40091BAA LTDBU-0370-4 1 16.9 Ω - 5000 W 1 16.9 Ω - 20000 W 1
Hx2000 FR5 LTFM-FR5-H FLANGE FOR LTVF-H40030~0038BAA 37
LTVF-H40038BAA LTVF-F40091CAA LTDBU-0370-4 1 16.9 Ω - 5000 W 1 16.9 Ω - 20000 W 1
LTVF-S40107BAA LTDBU-0550-4 1 11.4 Ω - 10000 W 1 11.4 Ω - 25000 W 1
LTVF-H40045BAA 45
LTVF-F40110CAA LTDBU-0550-4 1 11.4 Ω - 10000 W 1 11.4 Ω - 25000 W 1
Hx2000 FR6 LTFM-FR6-H FLANGE FOR LTVF-H40045~0061BAA
LTVF-H40061BAA LTVF-S40142BAA LTDBU-0550-4 1 11.4 Ω - 10000 W 1 11.4 Ω - 30000 W 1
55
LTVF-F40152CAA LTDBU-0550-4 1 11.4 Ω - 10000 W 1 11.4 Ω - 30000 W 1
Hx2000 LTVF-H40075BAA FR7 LTFM-FR7-H FLANGE FOR LTVF-H40075BAA
LTVF-S40169BAA LTDBU-0550-4 1 8.4 Ω - 10000 W 1 8.4 Ω - 41000 W 1
75
LTVF-H40091BAA LTVF-F40183CAA LTDBU-0750-4 1 8.4 Ω - 10000 W 1 8.4 Ω - 41000 W 1
Hx2000 FR8 LTFM-FR8-H FLANGE FOR LTVF-H40091~0107BAA LTVF-F40223AAA 90 LTDBU-0550-4 2 11.4 Ω - 15000 W 2 11.4 Ω - 25000 W 2
LTVF-H40107BAA
LTVF-F40264AAA 110 LTDBU-0750-4 2 8.4 Ω - 17000 W 2 8.4 Ω - 30000 W 2
LTVF-H40142BAA LTVF-F40325AAA 132 LTDBU-0750-4 2 8.4 Ω - 20000 W 2 8.4 Ω - 36000 W 2
Hx2000 FR9 LTFM-FR9-H FLANGE FOR LTVF-H40142~0169BAA
LTVF-F40370AAA 160 LTDBU-2200-4 1 2 Ω - 25000 W 1 2 Ω - 96000 W 1
LTVF-H40169BAA
LTVF-F40432AAA 185 LTDBU-2200-4 1 2 Ω - 30000 W 1 2 Ω - 111000 W 1
LTVF-F40547AAA 220 LTDBU-2200-4 1 2 Ω - 30000 W 1 2 Ω - 132000 W 1
LTVF-F40613AAA 280 LTDBU-2200-4 2 2 Ω - 40000 W 2 2 Ω - 84000 W 2
LTVF-F40731AAA 315 LTDBU-2200-4 2 2 Ω - 60000 W 2 2 Ω - 95000 W 2
LTVF-F40877AAA 375 LTDBU-2200-4 2 2 Ω - 60000 W 2 2 Ω - 113000 W 2
Note: 1) DBR rating for Single-Phase 230Vac drive & Three-Phase 230V drive, contact nearest branch office. *(2) Above DBR chart is for Crane/ Hoist Applications
3) DBU shall be purchased from L&T however DBR of given values must be purchased from local vendors. 4) For Elevator please contact nearest branch office.

58 59
Peripheral Devices Peripheral Devices
Incomer (MPCB / MCCB) & Magnetic Contactor (MC) Selection Chart for Input and Output Choke

Motor Specification of Breaker (MPCB / MCCB) Magnetic Contactor (MC) Drive Current (A) Chokes
Motor
(HD) Heavy Duty Normal Duty Heavy Duty Normal Duty (ND) Normal Heavy I/P AC Choke DC Choke O/P Choke
kW Type A Type A Type A Type A kW Duty Duty mH/A mH/A mH/A
0.75 MOG-S1/MOG-H1 2.5 - 4 MOG-S1/MOG-H1 4 - 6.3 MNX 9 MNX 9 0.75 2 1.3 4.81 /4.8 16/4.27 8.1/3
1.5 MOG-S1/MOG-H1 4 - 6.3 MOG-S1/MOG-H1 6.3 - 10 MNX 9 MNX 9 1.1 3.1 2.5 4.81 /4.8 16/4.27 6.54/4.2
2.2 MOG-S1/MOG-H1 6.3 - 10 MOG-S1/MOG-H1 6.3 - 10 MNX 9 MNX 9 1.5 4 2.5 4.81 /4.8 16/4.27 6.54/5
3.7 MOG-S1/MOG-H1 6.3 - 10 MOG-H1 11.0 - 16.0 MNX 9 MNX 18 2.2 6 4 3.23/7.5 12/6.41 3.71/7
5.5 MOG-H1 11.0 - 16.0 MOG-H1 14 - 20 MNX 18 MNX 18 3 6.9 5.5 3.23/7.5 12/6.41 2.45/8
7.5 MOG-H1 14 - 20 MOG-H1 24 - 32 MNX 18 MNX 25 3.7 8 6 2.34/10 8/8.9 2.45/9
11 MOG-H1 24-32 MOG-H2 28 - 40 MNX 25 MNX 40 4 10 8 1.22/15 5.4/13.2 1.9/12
15 MOG-H2 28 - 40 MOG-H2 35 - 50 MNX 40 MNX 45 5.5 12 8 1.22/15 5.34/14 1.9/12
18.5 MOG-H2 35 - 50 MOG-H2 45 - 63 MNX 45 MNX 50 7.5 16 12 1.22/18 3.2/17 1.1/18
22 MOG-H2 45 - 63 DN0 - 100M 80 MNX 50 MNX 70 11 24 16 0.78/27 2.5/25 0.81/25
30 DN0 - 100M 80 DN0 - 100M 100 MNX 70 MNX 80 15 30 24 0.59/35 1.9/32 0.54/35
37 DN0 - 100M 100 DN1 - 160M 125 MNX 80 MNX 110 18.5 39 30 0.46/44 1.4/41 0.45/40
45 DN1 - 160M 125 DN1 - 160M 160 MNX 110 MNX 140 22 45 39 0.4/52 1.0/49 0.36/46
55 DN1 - 160M 160 DN2 - 250M 200 MNX 140 MNX 185 30 61 45 0.3/68 0.7/64 0.29/62
75 DN2 - 250M 200 DN2 - 250M 250 MNX 185 MNX 225 37 75 61 0.232/98 0.23/78
90 DN2 - 250M 250 DN3 - 400M 320 MNX 225 MNX 265 45 91 75 0.195/118 0.2/95
110 DN3 - 400M 320 DN3 - 400M 400 MNX 265 MNX 325 55 110 91 0.157/142 0.16/115
132 DN3 - 400M 400 DN3 - 630M 500 MNX 325 MNX 400 75 152 110 0.122/196 0.12/160
160 DN3 - 630M 500 DN3 - 630M 500 MNX 400 MNX 550 90 183 152 0.096/237 0.12/190
185 DN3 - 630M 500 DN3 - 630M 630 MNX 550 MNX 550 110 223 183 0.081/289 Built-in 0.077/230
220 DN3 - 630M 630 DN4 - 1250N 320-800 MNX 550 MNX 650 132 264 223 0.069/341 0.067/270
280 DN4 - 1250N 320-800 DN4 - 1250N 400-1000 MNX 650 MNX* 400* 160 325 264 0.057/420 0.050/330
315 DN4 - 1250N 400-1000 DN4 - 1250N 500-1250 MNX* 400* MNX* 550* 185 370 325 0.042/558 0.045/380
375 DN4 - 1250N 500-1250 DN4 - 1250N 500-1250 MNX* 550* MNX* 550* 220 432 370 0.042/558 0.034/475
280 547 432 0.029/799 0.033/600
315 613 547 0.029/799 0.09/836 0.031/630
Note:
1) MC (Magnetic Contactor) current is 1.3 ~ 1.5 times of Drives rated current
2) MCCB should be used to protect against overload and damage of drive installation from the fault current.
375 731 613 0.024/952 0.076/996 0.031/800
3) From 22kW to 220kW MCCB dsine with frame size DN0 to DN3 with thermal-magnetic realease
& for above 220 kW MCCB dsine with frame DN4 - 1250N is used with MTX1.0 release.
450 877 731 0.024/952 0.064/1195 0.028/930
4) *2 contactors are used in parallel

Device Purpose Details


To protect Always install the MCCB or MPCB on the power supply side to
MCCB or MPCB
inverter wiring protect the inverter from Short Circuit & Overload protection
Used at Input side to provide complete isolation when drive
Magnetic is switched off thus protecting the internal components.
For Isolation
Contactor Also used for preventing burning of braking resistor with
thermal feedback
To improve
Input AC or DC Use for further improving the power factor of the inverter
Inverter Power
Reactor by suppressing the harmonics from the power supply
Factor
To avoid nuisance tripping of inverter due to leakage current
To avoid nuisance
Output Reactor caused because of the capacitive effect in longer cables
tripping of inverter
between inverter & motor
Shortens the deceleration time by consuming the regenerative
Braking Resistor To stop the energy of the motor by the resistor
machine within
the preset time Used in combination with the braking resistor to reduce the
Braking Unit
deceleration time of the motor

60 61
Other Automation Products Standard Specifications
Model
LTRBU - oooo - 4 0075 0150 0220 0370 0450 0550 0750 0900 1100 1320 1600 2200 2800
Number
Nominal applied
7.5 15 22 37 45 55 75 90 110 132 160 220 280
VFD [kW]
Rated DC input
12.3 25.5 36 60.2 72.7 88.6 121 147 188.6 214.8 259.7 352 415.2
current (AVG)[A]
Rating Rated AC output
13.5 27.5 39.2 64.6 77.9 94.7 125.5 151 187.5 208.8 250 328 401.4
current (RMS)[A]
Regenerative Braking Unit Braking torque 150% for 1s, 100% for 100s, 35% Continuous operation
Braking duty cycle
RBu [%ED]
25%ED(Enable Duty)

DC input voltage 400 - 800Vdc


Braking torque: 150% for 1s, 100% for 100s, 35% AC output voltage 380 - 480Vac, 50Hz/60Hz
Continuous operation
Allowable voltage
Power -10% ~ +10%
fluctuation Note 1)
Range: 7.5kW to 280kW
Allowable
frequency ±3Hz/300ms (Free phase rotation)
fluctuation

Note 1: The allowable voltage fluctuation doesn’t mean a continuous operation but instantaneous variation. Contact one of the official distributors or representatives if you need a continuous operation.

Common Specifications

Item Specification

Control method 120-degree phase current conduction


Input signals RUNF, RUNS , EST and RST

Terminals Alarm relay output signal


250Vac 1A or less, 30Vdc 1A or less, N.O. / N.C.
Multi-function open collector
24Vdc 50mA or less
output signal
Overcurrent Protects at approximately 200% of rated current or more
Protects at approximately 150% of rated current or more
Overcurrent suppression
(in case that the current flows over a certain period of time)
Overvoltage Protects at approximately 850VDC or more
Undervoltage Protects at approximately 400Vdc or more
Protective Overload Protect at 100% for 100s, 150% for 1s or more
function
Overheating Protects when detected by internal thermister
Internal system error Protects when detecting a internal system error
AC Line open-phase Protects at AC power supply open-phase detection
External emergency stop signal Protects by external input signal
Fan trip Protects when cooling fan has a problem

Cooling method Forced cooling

Installation area Indoor (without corrosive gas, flammable gas, oil mist and dust, etc.)
Ambient temperature -10 ~ +40oC (free of ice or frost)
Note:
note1) Make sure to use the specified AC reactor or DC reactor which L&T recommends.
Environment Storage temperature -20 ~ +65 oC (free of ice or frost)
note2) The wire length between DC-Link(+),(-) of the drive and P(+), (-) of RBu should not exceed 5m.
note3) The wire length between AC reactor and drive should not exceed 10m. Ambient humidity 90% RH or less and free of condensation
note4) Keep wiring between DC Reactor and drive as short as possible. Its wire length should not exceed
5m. (*The phase difference of three-phase power may be recognized automatically.) Altitude Up to 1,000m above sea level
Vibration 5.9m/s2 (=0.6G) or less

62 63
Dimension & Weights Other Automation Products

Soft Starter: Standard Applications


CSX & CSXi
Feature:
• Built-in bypass contactor
• Soft start / soft stop / adjustable current limit
• Essential motor protections against:
• Overload & single phasing
• Instantaneous overcurrent
• Phase sequence reversal
• Abnormality in supply
• Unbalanced current
• Thermistor protection through PTC
• Excess start time setting
• Communication and PC Interface options available

Range: 7.5 to 110kW

Soft Starter
EMX3
Features:
• 3-Phase operation control
• Built-in bypass contactor till 1000A
• XLR-8 adaptive acceleration & deceleration control for
pumps
• Conformal coated PCB
• Electronic motor overload protection
• 99 event logs with time stamping, Last 8 trip logs
• Operating Temp 500C
Mounting hole
External dimension (mm) Mounting dimension (mm) Weight (kg) • 5DI, 4DO, 1AO
size
Cat. No. Capacity • Communication options available
W H D W1 H1 • Control voltage from 94VAC to 484VAC
LTRBU-0075-4 7.5 12 • Forward / reverse Jog
• Comprehensive motor protection
LTRBU-0150-4 15 200 390 200.7 160 372
15 • Large LCD detachable keypad
LTRBU-0220-4 22 • 2 motor data sets
LTRBU-0370-4 37 • Fully programmable overload trip
LTRBU-0450-4 45 200 430 264.7 160 412 17 • Built-in RTD & thermistor inputs
• Auto detection of inline or inside delta power connection
LTRBU-0550-4 55
• Programmable auto start/stop
LTRBU-0750-4 75 M6 • Power through operation allows to run soft starter even with
LTRBU-0900-4 90 200 560 284.7 160 540 22 one SCR shorted
LTRBU-1100-4 110 • I/O expansion card (optional)
LTRBU-1320-4 132
300 700 295.7 240 680 26 Applications:
LTRBU-1600-4 160 Centrifugal pump, compressors, conveyor, crusher, fan, etc.
LTRBU-2200-4 220
360 740 309.7 319.5 720 31
LTRBU-2800-4 280 Range: 23A to 1600A

64 65
Other Automation Products Other Automation Products

HMI
Features:
Soft Starter • Large Memory: Upto 128MB display and 1MB back-up
• Various Communication Interface:
EMX4e Ethernet / RS-232C / 485
• USB host and device, SD memory card interface
Features: • Web server / Data Monitoring, Remote controlling
• Built in bypass contactor and monitoring
• Compact & Flexible Design • Presence sensor (within 1m), Sound Output
• Screw-less design for easy and fast servicing
• USB port for easy and fast commissioning
and data extraction
• Full graphical display with multi-languages
Range: Text Display & 4” to 15” TFT color LCD
support
• Built-in Simulation Mode
• 384 event logs
• Communication options available
• Fire Mode function available
• Starts per hour counter

Applications: PLC
Centrifugal pumps, fans, conveyors, crusher, etc.
Features:
• Processing speed: 0.06 µs/step
Range: 24A to 580A • Built-in Function: RTC, HSC, PTO, PID, Interrupt, Analog I/O
• Various communication Interface: Built-in USB / RS-232C /
485 / Ethernet, optional other communication modules
• Built-in Web-server, Email
• EtherCAT based motion control modules with Virtual Axis
• Built-in SD Card interface & Smart Remote I/O

Soft Starter
EMX4i Range: Upto 352 local I/O, Upto 5728 remote I/O points

Features:
• Built in bypass contactor
• Compact & Flexible Design
• Screw-less design for easy and fast servicing
• USB port for easy and fast commissioning and
data extraction
• Full graphical display with multi-languages SERVO
support
• Real time graphs of motor operating Features:
performance • Absolute encoder (standard)
• 384 event logs • 1.6 kHz Frequency response
• Advanced protection system • Serial communication (RS-422 / 485, Modbus)
• Communication options available • Supports various operation modes (CSP, CSV, CST, PP,
• Smart card for level controlled pump activation PV, PT, HM, IP, etc)
and pump protection • Safe-torque off function, 4-step notch filter
• Under voltage/ Over voltage protection • 2-step vibration suppression filter at the load position
• Starts per hour counter • Voltage: 200Vac / 400Vac
• Fire Mode function available • Speed: 1500rpm / 3000rpm
• Power through function available • Control: Pulse / Analog or Network

Applications:
Centrifugal pumps, fans, conveyors, crusher, etc.

Range: 24A to 580A Range: 0.1kW to 15kW

66 67
Electrical Standard Products (ESP) Offices:

HEAD OFFICE Khairasol, Degaul Avenue L&T Business Park,


L&T Business Park, Durgapur 713 212 Tower 'B' / 5th Floor
Tower 'B' / 3rd Floor Tel: 0343-2540448 / 2540449 / 2540443 Saki Vihar Road, Powai
Saki Vihar Road, Powai Fax: 0343-2540442 Mumbai 400 072
Mumbai 400 072 e-mail: esp-dgp@LNTEBG.com Tel: 022-67052874 / 2737 / 1156
Tel: 022-67053229 Fax: 022-67051112
Fax: 022-67051112 5, Milanpur Road, Bamuni Maidan e-mail: esp-bom@LNTEBG.com
e-mail: cic@LNTEBG.com Guwahati 781 021
Tel: +91 8876554410 / 8876554417 12, Shivaji Nagar
BRANCH OFFICES Fax: 361-2551308 North Ambajhari Road
501, Sakar Complex I e-mail: esp-ghy@LNTEBG.com Nagpur 440 010
Opp. Gandhigram Rly. Station
Ashram Road Tel: 0712-2260012 / 6606421
II Floor, Vasantha Chambers Fax: 2260030 / 6606434
Ahmedabad 380 009 5-10-173, Fateh Maidan Road
Tel: 079-66304006-11 e-mail: esp-nag@LNTEBG.com
Hyderabad 500 004
Fax: 079-66304025
Tel: 040-67015052 32, Shivaji Marg
e-mail: esp-ahm@LNTEBG.com
Fax: 040-23296468 P. O. Box 6223
38, Cubbon Road, P. O. Box 5098 e-mail: esp-hyd@LNTEBG.com New Delhi 110 015
Bengaluru 560 001 Tel: 011-41419514 / 5 / 6
Tel: 080-25020100 / 25020324 Monarch Building, 1st Floor Fax: 011-41419600
Fax: 080-25580525 D-236 & 237, Amrapali Marg e-mail: esp-del@LNTEBG.com
e-mail: esp-blr@LNTEBG.com Vaishali Nagar
Jaipur 302 021 L&T House
131/1, Zone II Tel: 0141-4385914 to 18 P. O. Box 119
Maharana Pratap Nagar Fax: 0141-4385925 191/1, Dhole Patil Road
Bhopal 462 011 e-mail: esp-jai@LNTEBG.com Pune 411 001
Tel: 0755-3080511 / 05 / 08 / 13 / 17 / 19 Tel: 020-66033395 / 66033279
Fax: 0755-3080502 Akashdeep Plaza, 2nd Floor
Fax: 020-26164048 / 26164910
e-mail: esp-bho@LNTEBG.com P. O. Golmuri
e-mail: esp-pnq@LNTEBG.com
Jamshedpur 831 003
Plot No. 559, Annapurna Complex Jharkhand
Lewis Road Crystal Tower,
Tel: 0657-2312205 / 38
Bhubaneswar 751 014 4th Floor, G. E. Road
Fax: 0657-2341250
Tel: 0674-6451342 / 2436690 / 2436696 Telibandha
e-mail: esp-jam@LNTEBG.com
Fax: 0674-2537309 Raipur 492 006
e-mail: esp-bsr@LNTEBG.com Skybright Bldg; M. G. Road Tel: 0771-4283214
Ravipuram Junction, Ernakulam e-mail: esp-raipur@LNTEBG.com
Aspire Towers, 4th Floor Kochi 682 016
Plot No. 55, Phase-I Tel: 0484-4409420 / 4 / 5 / 7 3rd Floor
Industrial & Business Park Fax: 0484-4409426 Vishwakarma Chambers
Chandigarh 160 002 e-mail: esp-cok@LNTEBG.com Majura Gate, Ring Road
Tel: 0172-4646840 / 41 / 42 / 46 / 53 Surat 395 002
Fax: 0172-4646802 Tel: 0261-2473726
3-B, Shakespeare Sarani
e-mail: esp-chd@LNTEBG.com Fax: 0261-2477078
Kolkata 700 071
Tel: 033-42005982 e-mail: esp-sur@LNTEBG.com
L&T Construction Campus
TC-1 Building, II Floor Fax: 033-22821025 / 7587
e-mail: esp-ccu@LNTEBG.com Radhadaya Complex
Mount-Poonamallee Road Old Padra Road
Manapakkam
A28, Indira Nagar, Faizabad Road Near Charotar Society
Chennai 600 089
Tel: 044-2270 6800 Lucknow 226 016 Vadodara 390 007
Fax: 044-22706940 Tel: 0522-4929905 / 04 Tel: 0265-6613610 / 1 / 2
e-mail: esp-maa1@LNTEBG.com Fax: 0522-2311671 Fax: 0265-2336184
e-mail: esp-Lko@LNTEBG.com e-mail: esp-bar@LNTEBG.com
67, Appuswamy Road
Post Bag 7156 No: 73, Karpaga Nagar, 8th Street Door No. 49-38-14/3/2, 1st floor,
Opp. Nirmala College K. Pudur NGGO's Colony, Akkayyapalem,
CBMC/PRD/012019
Coimbatore 641 045 Madurai 625 007 Visakhapatnam 530 016
Tel: 0422-2588120 / 1 / 5 Tel: 0452-2567405 / 2561068 / 2561657 Tel: 0891-2791126 / 2711125
Fax: 0422-2588148 Fax: 0452-2567552 Fax: 0891-2791100
e-mail: esp-cbe@LNTEBG.com e-mail: esp-mdu@LNTEBG.com e-mail: esp-viz@LNTEBG.com

Product improvement is a continuous process. For the latest information and special applications, please contact any of our offices listed here.

LARSEN & TOUBRO LIMITED, ELECTRICAL STANDARD PRODUCTS


Powai Campus, Mumbai 400 072

Customer Interaction Center (CIC)


BSNL / MTNL (toll free): 1800 233 5858 Reliance (toll free): 1800 200 5858
Tel: 022 6774 5858 Fax: 022 6774 5859 Email: cic@Lntebg.com
Web: www.Lntebg.com

Regd. Office: L&T House, N. M. Marg, Ballard Estate, Mumbai - 400 001, INDIA. CIN: L99999MH1946PLC004768

You might also like