0% found this document useful (0 votes)
103 views11 pages

MSDS - Acetone

This Safety Data Sheet provides information on Acetone, including its identification, hazards, and recommended safety measures. Acetone is classified as a highly flammable liquid that can cause serious eye irritation and may lead to drowsiness or dizziness. The document outlines first aid measures, firefighting procedures, and exposure controls necessary for safe handling and storage in laboratory settings.

Uploaded by

TarakJana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
103 views11 pages

MSDS - Acetone

This Safety Data Sheet provides information on Acetone, including its identification, hazards, and recommended safety measures. Acetone is classified as a highly flammable liquid that can cause serious eye irritation and may lead to drowsiness or dizziness. The document outlines first aid measures, firefighting procedures, and exposure controls necessary for safe handling and storage in laboratory settings.

Uploaded by

TarakJana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

SAFETY DATA SHEET

Creation Date Oct-2013 Revision Date Oct-2018 Revision Number 2

SECTION 1: IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE


COMPANY/UNDERTAKING
1.1. Product identification

Product Description: Acetone


Product Grade: ER, SQ, HPLC
Cat No. : Q32007,Q33515,Q33517,Q3351C,Q3351H,Q32005,Q32006,Q3200C,Q33516,
Q41517, Q44106
Synonyms 2-Propanone
CAS-No 67-64-1
EC-No. 200-662-2
Molecular Formula C3 H6 O
Reach Registration Number 01-2119471330-49

1.2. Relevant identified uses of the substance or mixture and uses advised against

Recommended Use Laboratory chemicals.


Uses advised against No Information available

1.3. Details of the supplier of the safety data sheet

Company Thermo Fisher Scientific India Pvt. Ltd


403-404, B-wing, Delphi, Hiranandani Business Park,
Powai, Mumbai 400076, INDIA
E-mail address laboratorysolutions@thermofisher.com

1.4. Emergency telephone number


India Toll Free: 18 00 22 22 30
Chemtrec US: (800) 424-9300
Chemtrec EU: 001 (202) 483-7616

SECTION 2: HAZARDS IDENTIFICATION


2.1. Classification of the substance or mixture

CLP Classification - Regulation (EC) No 1272/2008

Physical hazards

Flammable liquids Category 2 (H225)

Health hazards

Serious Eye Damage/Eye Irritation Category 2 (H319)


Specific target organ toxicity - (single exposure) Category 3 (H336)

Environmental hazards
Based on available data, the classification criteria are not met

2.2. Label elements

FSUA0600
Page 1 / 11
SAFETY DATA SHEET
Acetone Revision Date Oct-2018

Signal Word Danger

Hazard Statements
H225 - Highly flammable liquid and vapor
H319 - Causes serious eye irritation
H336 - May cause drowsiness or dizziness
EUH066 - Repeated exposure may cause skin dryness or cracking

Precautionary Statements
P210 - Keep away from heat/sparks/open flames/hot surfaces. - No smoking
P240 - Ground/Bond container and receiving equipment
P261 - Avoid breathing dust/ fume/ gas/ mist/ vapors/ spray
P280 - Wear protective gloves/ protective clothing/ eye protection/ face protection
P305 + P351 + P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and
easy to do. Continue rinsing

2.3. Other hazards

Substance is not considered persistent, bioaccumulative and toxic (PBT) / very persistent and very bioaccumulative (vPvB)

SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS


3.1. Substances

Component CAS-No EC-No. Weight % CLP Classification - Regulation (EC) No


1272/2008
Acetone 67-64-1 EEC No. 200-662-2 >95 Flam. Liq. 2 (H225)
Eye Irrit. 2 (H319)
STOT SE 3 (H336)
EUH066

Reach Registration Number 01-2119471330-49

Full text of Hazard Statements: see section 16

SECTION 4: FIRST AID MEASURES


4.1. Description of first aid measures

Eye Contact Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes.
Obtain medical attention.

Skin Contact Wash off immediately with plenty of water for at least 15 minutes. Obtain medical attention.

Ingestion Do not induce vomiting. Obtain medical attention.

Inhalation Move to fresh air. If breathing is difficult, give oxygen. Get medical attention immediately if
symptoms occur.

Protection of First-aiders Remove all sources of ignition. Use personal protective equipment.

FSUA0600
Page 2 / 11
SAFETY DATA SHEET
Acetone Revision Date Oct-2018

4.2. Most important symptoms and effects, both acute and delayed

Breathing difficulties. Symptoms of overexposure may be headache, dizziness, tiredness,


nausea and vomiting: May cause pulmonary edema

4.3. Indication of any immediate medical attention and special treatment needed

Notes to Physician Treat symptomatically. Symptoms may be delayed.

SECTION 5: FIREFIGHTING MEASURES


5.1. Extinguishing media

Suitable Extinguishing Media


CO 2, dry chemical, dry sand, alcohol-resistant foam. Water spray. Cool closed containers exposed to fire with water spray.

Extinguishing media which must not be used for safety reasons


Do not use water jet.

5.2. Special hazards arising from the substance or mixture

Flammable. Risk of ignition. Containers may explode when heated. Vapors may form explosive mixtures with air. Vapors may
travel to source of ignition and flash back.

Hazardous Combustion Products


Carbon monoxide (CO), Carbon dioxide (CO2), Formaldehyde, Methanol.

5.3. Advice for firefighters

SECTION 6: ACCIDENTAL RELEASE MEASURES


6.1. Personal precautions, protective equipment and emergency procedures

Use personal protective equipment. Ensure adequate ventilation. Remove all sources of ignition. Take precautionary measures
against static discharges. Keep people away from and upwind of spill/leak. Avoid contact with skin, eyes and inhalation of vapors.

6.2. Environmental precautions

Should not be released into the environment.

6.3. Methods and material for containment and cleaning up

Remove all sources of ignition. Take precautionary measures against static discharges. Soak up with inert absorbent material.
Keep in suitable, closed containers for disposal. Use spark-proof tools and explosion-proof equipment.

6.4. Reference to other sections

Refer to protective measures listed in Sections 8 and 13.

SECTION 7: HANDLING AND STORAGE


7.1. Precautions for safe handling

Do not breathe vapors or spray mist. Do not get in eyes, on skin, or on clothing. Wear personal protective equipment. Ensure
adequate ventilation. Keep away from open flames, hot surfaces and sources of ignition. Take precautionary measures against
static discharges. Use only non-sparking tools. Use explosion-proof equipment. To avoid ignition of vapors by static electricity
discharge, all metal parts of the equipment must be grounded.

FSUA0600
Page 3 / 11
SAFETY DATA SHEET
Acetone Revision Date Oct-2018

Hygiene Measures
Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do
not eat, drink or smoke when using this product. Remove and wash contaminated clothing before re-use. Wash hands before
breaks and at the end of workday.

7.2. Conditions for safe storage, including any incompatibilities

Flammables area. Keep containers tightly closed in a dry, cool and well-ventilated place. Keep away from heat and sources of
ignition.

7.3. Specific end use(s)

Use in laboratories

SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION


8.1. Control parameters

Exposure limits
List source(s): EU - Commission Directive 2006/15/EC of 7 February 2006 establishing a second list of indicative occupational
exposure limit values in implementation of Council Directive 98/24/EC and amending Directives 91/322/EEC and 2000/39/EC on
the protection of the health and safety of workers from the risks related to chemical agents at work. UK - EH40/2005 Containing the
workplace exposure limits (WELs) for use with the Control of Substances Hazardous to Health Regulations (COSHH) 2002 (as
amended). Updated by September 2006 official press release and October 2007 Supplement. IRE - 2010 Code of Practice for the
Safety, Health and Welfare at Work (Chemical Agents) Regulations 2001. Published by the Health and Safety Authority.

Component European Union The United Kingdom France Belgium Spain


Acetone TWA: 500 ppm 8 hr TWA: 500 ppm TWA / VME: 500 ppm (8 TWA: 500 ppm 8 uren TWA / VLA-ED: 500
TWA: 1210 mg/m3 8 hr TWA: 1210 mg/m3 heures). restrictive limit TWA: 1210 mg/m3 8 ppm (8 horas)
STEL: 1500 ppm TWA / VME: 1210 uren TWA / VLA-ED: 1210
STEL: 3620 mg/m3 mg/m3 (8 heures). STEL: 1000 ppm 15 mg/m3 (8 horas)
restrictive limit minuten
STEL / VLCT: 1000 STEL: 2420 mg/m3 15
ppm. restrictive limit minuten
STEL / VLCT: 2420
mg/m3. restrictive limit

Component Italy Germany Portugal The Netherlands Finland


Acetone TWA: 500 ppm 8 ore. TWA: 500 ppm STEL: 750 ppm 15 STEL: 2420 mg/m3 15 TWA: 500 ppm 8
Media Ponderata nel TWA: 1200 mg/m3 minutos minuten tunteina
Tempo TWA: 500 ppm 8 horas TWA: 1210 mg/m3 8 TWA: 1200 mg/m3 8
TWA: 1210 mg/m3 8 TWA: 1210 mg/m3 8 uren tunteina
ore. Media Ponderata horas STEL: 630 ppm 15
nel Tempo minuutteina
STEL: 1500 mg/m3 15
minuutteina

Component Austria Denmark Switzerland Poland Norway


Acetone MAK-KZW: 2000 ppm TWA: 250 ppm 8 timer STEL: 1000 ppm 15 STEL: 1800 mg/m3 15 TWA: 125 ppm 8 timer
15 Minuten TWA: 600 mg/m3 8 timer Minuten minutach TWA: 295 mg/m3 8 timer
MAK-KZW: 4800 mg/m3 STEL: 2400 mg/m3 15 TWA: 600 mg/m3 8 STEL: 125 ppm 15
15 Minuten Minuten godzinach minutter.
MAK-TMW: 500 ppm 8 TWA: 500 ppm 8 STEL: 295 mg/m3 15
Stunden Stunden minutter.
MAK-TMW: 1200 mg/m3 TWA: 1200 mg/m3 8
8 Stunden Stunden

Component Bulgaria Croatia Ireland Cyprus Czech Republic


Acetone TWA: 600 mg/m3 TWA-GVI: 500 ppm 8 TWA: 500 ppm 8 hr. Skin-potential for TWA: 800 mg/m3 8
STEL : 1400 mg/m3 satima. TWA: 1210 mg/m3 8 hr. cutaneous absorption hodinách.
TWA-GVI: 1210 mg/m3 STEL: 1500 ppm 15 min TWA: 500 ppm Ceiling: 1500 mg/m3
8 satima. STEL: 3630 mg/m3 15 TWA: 1210 mg/m3
STEL-KGVI: 1500 ppm min
15 minutama.
STEL-KGVI: 3620

FSUA0600
Page 4 / 11
SAFETY DATA SHEET
Acetone Revision Date Oct-2018

mg/m3 15 minutama.

Component Estonia Gibraltar Greece Hungary Iceland


Acetone TWA: 500 ppm 8 TWA: 500 ppm 8 hr STEL: 3560 mg/m3 STEL: 2420 mg/m3 15 TWA: 250 ppm 8
tundides. TWA: 1210 mg/m3 8 hr TWA: 1780 mg/m3 percekben. CK klukkustundum.
TWA: 1210 mg/m3 8 Substances with TWA: 600 mg/m3 8
tundides. European indicative klukkustundum.
limits (96/94/EC, Ceiling: 500 ppm
2000/39/EC, Ceiling: 1200 mg/m3
2006/15/EC,
2009/161/EU), which
currently has no peak
limit concentration. In
these cases, Annex 3.1.
should be used
exercised
TWA: 1210 mg/m3 8
órában. AK

Component Latvia Lithuania Luxembourg Malta Romania


Acetone TWA: 500 ppm TWA: 500 ppm IPRD TWA: 500 ppm 8 TWA: 500 ppm TWA: 500 ppm 8 ore
TWA: 1210 mg/m3 TWA: 1210 mg/m3 Stunden TWA: 1210 mg/m3 TWA: 1210 mg/m3 8 ore
IPRD STEL: 1000 TWA: 1210 mg/m3 8
ppm STEL: 2420 Stunden
mg/m3

Component Russia Slovak Republic Slovenia Sweden Turkey


Acetone TWA: 200 mg/m3 1723 Ceiling: 2420 mg/m3 TWA: 500 ppm 8 urah Indicative STLV: 500 TWA: 500 ppm 8 saat
STEL: 800 mg/m3 1723 TWA: 500 ppm TWA: 1210 mg/m3 8 ppm 15 minuter TWA: 1210 mg/m3 8
TWA: 1210 mg/m3 urah Indicative STLV: 1200 saat
mg/m3 15 minuter
LLV: 250 ppm 8 timmar.
LLV: 600 mg/m3 8
timmar.

Biological limit values


List source(s):

Component European Union United Kingdom France Spain Germany


Acetone Acetone: 100 mg/L urine Acetone: 50 mg/L urine Acetone: 80 mg/L urine
end of shift end of shift (end of shift )

Component Italy Finland Denmark Bulgaria Romania


Acetone Acetone: 80 mg/L urine Acetone: 50 mg/L urine
at the end of exposure end of shift
or end of shift

Component Gibraltar Latvia Slovak Republic Luxembourg Turkey


Acetone Acetone: 80 mg/L urine
end of exposure or work
shift

Monitoring methods
BS EN 14042:2003 Title Identifier: Workplace atmospheres. Guide for the application and use of procedures for the assessment of
exposure to chemical and biological agents.
MDHS70 General methods for sampling airborne gases and vapours
MDHS 88 Volatile organic compounds in air. Laboratory method using diffusive samplers, solvent desorption and gas
chromatography
MDHS 96 Volatile organic compounds in air - Laboratory method using pumped solid sorbent tubes, solvent desorption and gas
chromatography

Derived No Effect Level (DNEL) See table for values


Route of exposure Acute effects (local) Acute effects Chronic effects Chronic effects
(systemic) (local) (systemic)
Oral
Dermal 186 mg/kg

FSUA0600
Page 5 / 11
SAFETY DATA SHEET
Acetone Revision Date Oct-2018

Inhalation 2420 mg/m3 1210 mg/m3

Predicted No Effect Concentration See values below.


(PNEC)
Fresh water 10.6 mg/l
Fresh water sediment 30.4 mg/kg
Marine water 1.06 mg/l
Marine water sediment 3.04 mg/kg
Water Intermittent 21 mg/l
Microorganisms in sewage 100 mg/l
treatment
Soil (Agriculture) 29.5 mg/kg

8.2. Exposure controls

Engineering Measures
Ensure adequate ventilation, especially in confined areas. Ensure that eyewash stations and safety showers are close to the
workstation location. Use explosion-proof electrical/ventilating/lighting/equipment.
Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or
equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to
control hazardous materials at source
Personal protective equipment
Eye Protection Goggles (European standard - EN 166)
Hand Protection Protective gloves

Glove material Breakthrough time Glove thickness EU standard Glove comments


Butyl rubber > 480 minutes 0.5 mm EN 374 Level 6 As tested under EN374-3 Determination of
Resistance to Permeation by Chemicals
Neoprene gloves < 30 minutes 0.45 mm
Skin and body protection Wear appropriate protective gloves and clothing to prevent skin exposure

Inspect gloves before use.


Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves.
(Refer to manufacturer/supplier for information)
Ensure gloves are suitable for the task: Chemical compatability, Dexterity, Operational conditions, User susceptibility, e.g.
sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger
of cuts, abrasion.
Remove gloves with care avoiding skin contamination.

Respiratory Protection When workers are facing concentrations above the exposure limit they must use
appropriate certified respirators.
To protect the wearer, respiratory protective equipment must be the correct fit and be used
and maintained properly
Large scale/emergency use Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits
are exceeded or if irritation or other symptoms are experienced
Recommended Filter type: low boiling organic solvent Type AX Brown conforming to
EN371
Small scale/Laboratory use Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure
limits are exceeded or if irritation or other symptoms are experienced.
Recommended half mask:- Valve filtering: EN405; or; Half mask: EN140; plus filter, EN
141
When RPE is used a face piece Fit Test should be conducted

Environmental exposure controls Do not allow material to contaminate ground water system.

SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES


9.1. Information on basic physical and chemical properties

Appearance Colorless
Physical State Liquid

FSUA0600
Page 6 / 11
SAFETY DATA SHEET
Acetone Revision Date Oct-2018

Odor sweet
Odor Threshold 19.8 ppm
pH 7
Melting Point/Range -95 °C / -139 °F
Softening Point No data available
Boiling Point/Range 56 °C / 132.8 °F
Flash Point -20 °C / -4 °F Method - Closed cup
Evaporation Rate 5.6 (Butyl Acetate = 1.0)
Flammability (solid,gas) Not applicable Liquid
Explosion Limits Lower 2.1 vol%
Upper 13 vol%
Vapor Pressure 247 mbar @ 20 °C
Vapor Density 2.0 (Air = 1.0)
Specific Gravity / Density 0.790
Bulk Density Not applicable Liquid
Water Solubility soluble
Solubility in other solvents No information available
Partition Coefficient (n-octanol/water)
Component log Pow
Acetone -0.24
Autoignition Temperature 465 °C / 869 °F
Decomposition Temperature > 4°C
Viscosity 0.32 mPa.s @ 20 °C
Explosive Properties Not explosive Vapors may form explosive mixtures with air
Oxidizing Properties Not oxidising

9.2. Other information

Molecular Formula C3 H6 O
Molecular Weight 58.08
Refractive index 1.358 - 1.359

SECTION 10: STABILITY AND REACTIVITY


10.1. Reactivity
None known, based on information available

10.2. Chemical stability


Stable under normal conditions.
10.3. Possibility of hazardous reactions

Hazardous Polymerization Hazardous polymerization does not occur.


Hazardous Reactions None under normal processing.

10.4. Conditions to avoid


Heat, flames and sparks. Incompatible products. Keep away from open flames, hot
surfaces and sources of ignition.
10.5. Incompatible materials
Strong oxidizing agents. Strong reducing agents. Strong bases. Peroxides. Halogenated
compounds. Alkali metals. Amines.

10.6. Hazardous decomposition products


SECTION 11: TOXICOLOGICAL INFORMATION
11.1. Information on toxicological effects

Product Information

FSUA0600
Page 7 / 11
SAFETY DATA SHEET
Acetone Revision Date Oct-2018

(a) acute toxicity;


Oral Based on available data, the classification criteria are not met
Dermal Based on available data, the classification criteria are not met
Inhalation Based on available data, the classification criteria are not met

Component LD50 Oral LD50 Dermal LC50 Inhalation


Acetone 5800 mg/kg ( Rat ) > 15800 mg/kg (rabbit) 76 mg/l, 4 h, (rat)
> 7400 mg/kg (rat)

(b) skin corrosion/irritation; Based on available data, the classification criteria are not met

(c) serious eye damage/irritation; Category 2


Test method OECD Test Guideline 405
Test species rabbit
Observation end point Irritating to eyes

(d) respiratory or skin sensitization;


Respiratory Based on available data, the classification criteria are not met
Skin Based on available data, the classification criteria are not met

(e) germ cell mutagenicity; Based on available data, the classification criteria are not met

Component Test method Test species Study result


Acetone OECD Test Guideline 471 in vivo negative
67-64-1 ( >95 ) AMES test
------------------------------------------- ------------------------------------------- -------------------------------------------
OECD Test Guideline 476 in vitro negative
Mammalian
Gene cell mutation

(f) carcinogenicity; Based on available data, the classification criteria are not met
There are no known carcinogenic chemicals in this product

(g) reproductive toxicity; Based on available data, the classification criteria are not met

(h) STOT-single exposure; Category 3

Results / Target organs Central nervous system (CNS).

(i) STOT-repeated exposure; Based on available data, the classification criteria are not met

Target Organs No information available.

(j) aspiration hazard; Based on available data, the classification criteria are not met
Symptoms / effects,both acute and Symptoms of overexposure may be headache, dizziness, tiredness, nausea and vomiting:
delayed May cause pulmonary edema

SECTION 12: ECOLOGICAL INFORMATION


12.1. Toxicity
Ecotoxicity effects .

Component Freshwater Fish Water Flea Freshwater Algae Microtox


Acetone Oncorhynchus mykiss: EC50 = 8800 mg/L/48h NOEC = 430 mg/l EC50 = 14500 mg/L/15
LC50 = 5540 mg/l 96h EC50 = 12700 mg/L/48h (algae; 96 h) min
Alburnus alburnus: EC50 = 12600 mg/L/48h
LC50 = 11000 mg/l 96h
Leuciscus idus: LC50 =
11300 mg/L/48h
Salmo gairdneri: LC50 =

FSUA0600
Page 8 / 11
SAFETY DATA SHEET
Acetone Revision Date Oct-2018

6100 mg/L/24h

12.2. Persistence and degradability Readily biodegradable


Persistence Persistence is unlikely, based on information available.
Component Degradability
Acetone 91 % (28 d) (OECD 301 B)
67-64-1 ( >95 )

12.3. Bioaccumulative potential Does not bioaccumulate


Component log Pow Bioconcentration factor (BCF)
Acetone -0.24 0.69

12.4. Mobility in soil The product contains volatile organic compounds (VOC) which will evaporate easily from all
surfaces Will likely be mobile in the environment due to its volatility. Disperses rapidly in
air
12.5. Results of PBT and vPvB Substance is not considered persistent, bioaccumulative and toxic (PBT) / very persistent
assessment and very bioaccumulative (vPvB).

12.6. Other adverse effects


Endocrine Disruptor Information This product does not contain any known or suspected endocrine disruptors
Persistent Organic Pollutant This product does not contain any known or suspected substance
Ozone Depletion Potential This product does not contain any known or suspected substance

SECTION 13: DISPOSAL CONSIDERATIONS


13.1. Waste treatment methods
Waste from Residues / Unused Waste is classified as hazardous. Dispose of in accordance with the European Directives
Products on waste and hazardous waste. Dispose of in accordance with local regulations.

Contaminated Packaging Dispose of this container to hazardous or special waste collection point. Empty containers
retain product residue, (liquid and/or vapor), and can be dangerous. Keep product and
empty container away from heat and sources of ignition.

European Waste Catalogue (EWC) According to the European Waste Catalogue, Waste Codes are not product specific, but
application specific.
Other Information Waste codes should be assigned by the user based on the application for which the product
was used. Do not dispose of waste into sewer. Can be incinerated, when in compliance
with local regulations.

SECTION 14: TRANSPORT INFORMATION


IMDG/IMO

14.1. UN number UN1090


14.2. UN proper shipping name ACETONE
14.3. Transport hazard class(es) 3
14.4. Packing group II

ADR

14.1. UN number UN1090


14.2. UN proper shipping name ACETONE
14.3. Transport hazard class(es) 3
14.4. Packing group II

IATA

14.1. UN number UN1090


14.2. UN proper shipping name ACETONE
14.3. Transport hazard class(es) 3

FSUA0600
Page 9 / 11
SAFETY DATA SHEET
Acetone Revision Date Oct-2018

14.4. Packing group II

14.5. Environmental hazards No hazards identified

14.6. Special precautions for user No special precautions required

14.7. Transport in bulk according to Not applicable, packaged goods


Annex II of MARPOL73/78 and the
IBC Code

SECTION 15: REGULATORY INFORMATION


15.1. Safety, health and environmental regulations/legislation specific for the substance or mixture

International Inventories X = listed


Component EINECS ELINCS NLP TSCA DSL NDSL PICCS ENCS IECSC AICS KECL
Acetone 200-662-2 - X X - X X X X X

National Regulations

Component Germany - Water Classification (VwVwS) Germany - TA-Luft Class


Acetone WGK 1

Component France - INRS (Tables of occupational diseases)


Acetone Tableaux des maladies professionnelles (TMP) - RG 84
Take note of Control of Substances Hazardous to Health Regulations (COSHH) 2002 and 2005 Amendment.
Take note of Dir 94/33/EC on the protection of young people at work
Take note of Directive 98/24/EC on the protection of the health and safety of workers from the risks related to chemical agents at
work

15.2. Chemical safety assessment

A Chemical Safety Assessment/Report (CSA/CSR) has been conducted by the manufacturer/importer

SECTION 16: OTHER INFORMATION


Full text of H-Statements referred to under sections 2 and 3
H225 - Highly flammable liquid and vapor
H319 - Causes serious eye irritation
H336 - May cause drowsiness or dizziness
EUH066 - Repeated exposure may cause skin dryness or cracking
Legend
CAS - Chemical Abstracts Service TSCA - United States Toxic Substances Control Act Section 8(b)
Inventory
EINECS/ELINCS - European Inventory of Existing Commercial Chemical DSL/NDSL - Canadian Domestic Substances List/Non-Domestic
Substances/EU List of Notified Chemical Substances Substances List
PICCS - Philippines Inventory of Chemicals and Chemical Substances ENCS - Japanese Existing and New Chemical Substances
IECSC - Chinese Inventory of Existing Chemical Substances AICS - Australian Inventory of Chemical Substances
KECL - Korean Existing and Evaluated Chemical Substances NZIoC - New Zealand Inventory of Chemicals

WEL - Workplace Exposure Limit TWA - Time Weighted Average


ACGIH - American Conference of Governmental Industrial Hygienists IARC - International Agency for Research on Cancer
DNEL - Derived No Effect Level PNEC - Predicted No Effect Concentration
RPE - Respiratory Protective Equipment LD50 - Lethal Dose 50%
LC50 - Lethal Concentration 50% EC50 - Effective Concentration 50%
NOEC - No Observed Effect Concentration POW - Partition coefficient Octanol:Water
PBT - Persistent, Bioaccumulative, Toxic vPvB - very Persistent, very Bioaccumulative

FSUA0600
Page 10 / 11
SAFETY DATA SHEET
Acetone Revision Date Oct-2018

ADR - European Agreement Concerning the International Carriage of ICAO/IATA - International Civil Aviation Organization/International Air
Dangerous Goods by Road Transport Association
IMO/IMDG - International Maritime Organization/International Maritime MARPOL - International Convention for the Prevention of Pollution from
Dangerous Goods Code Ships
OECD - Organisation for Economic Co-operation and Development ATE - Acute Toxicity Estimate
BCF - Bioconcentration factor VOC - Volatile Organic Compounds
Key literature references and sources for data
Suppliers safety data sheet, Chemadvisor - LOLI, Merck index, RTECS

Training Advice
Chemical hazard awareness training, incorporating labelling, Safety Data Sheets (SDS), Personal Protective Equipment (PPE) and
hygiene.
Use of personal protective equipment, covering appropriate selection, compatibility, breakthrough thresholds, care, maintenance, fit
and standards.
First aid for chemical exposure, including the use of eye wash and safety showers.
Fire prevention and fighting, identifying hazards and risks, static electricity, explosive atmospheres posed by vapours and dusts.

Creation Date Oct-2013


Next Revision Date Oct-2023
Revision Summary SDS section 1 updated and update of Format.

This safety data sheet complies with the requirements of Regulation (EC) No. 1907/2006
Disclaimer
The information provided in this Safety Data Sheet is correct to the best of our knowledge, information and belief at the
date of its publication. The information given is designed only as a guidance for safe handling, use, processing, storage,
transportation, disposal and release and is not to be considered a warranty or quality specification. The information
relates only to the specific material designated and may not be valid for such material used in combination with any other
materials or in any process, unless specified in the text