BHC SERIES(1P/2P 20-40 FLA)
z   1 Pole NO or 2 Pole NO
                                               z   Silver Cadmium Oxide Contacts
                                               z   Selectable Current:20A ,25A ,30A ,40A
                                               z   Selectable Coil Voltage: 24VAC, 120VAC,
                                                   208-240VAC, 277VAC
Partial Listing of Available 1 & 2 Pole Contactors
   FLA        Number            24V             120V                  208/240V                 277V
  Rating      of Pole           Coil            Coil                    Coil                   Coil
                 1         BHC-1A-20-24     BHC-1A-20-120           BHC-1A-20-240       BHC-1A-20-277
  20 FLA
                 2         BHC-2A-20-24     BHC-2A-20-120           BHC-2A-20-240       BHC-2A-20-277
                 1         BHC-1A-25-24     BHC-1A-25-120           BHC-1A-25-240       BHC-1A-25-277
  25 FLA
                 2         BHC-2A-25-24     BHC-2A-25-120           BHC-2A-25-240       BHC-2A-25-277
                 1         BHC-1A-30-24     BHC-1A-30-120           BHC-1A-30-240       BHC-1A-30-277
  30 FLA
                 2         BHC-2A-30-24     BHC-2A-30-120           BHC-2A-30-240       BHC-2A-30-277
                 1        BHC-1A-40-24D     BHC-1A-40-120D      BHC-1A-40-240D         BHC-1A-40-277D
  40 FLA
                 2        BHC-2A-40-24D     BHC-2A-40-120D      BHC-2A-40-240D         BHC-2A-40-277D
 INITIAL DIELECTRIC STRENGTH                       POWER POLE TERMINATIONS
 Between Contacts & Coils: 2200VAC                 Screw or Box Lug
 Between Poles: 2200VAC(includes shunt)            WIRE SIZE
 Between Open Contacts: 2200VAC(no shunt)          Screw                  16-8
 ARC COVER                                         Box Lug                14-4
 Optional on 20-30 FLA                             RECOMMENDED TIGHTENING TORQUE
 Standard on 40 FLA                                Screw                  25 in.lbs
 INSULATION SYSTEM                                 Box Lug                40 in.lbs
 130℃ Class B                                      QUICK CONNECTS
 TEMPERATURE RANGE                                 Coil terminals      Dual: .250”QC
 -40℃ to +65℃                                      Power terminals     1 Pole: Quad . 250”QC
 -40°F to +150°F                                                      2 Pole: Qual or Quad . 250”QC
 UNIT WEIGHT
 1 Pole         0.23Kg
 2 Pole         0.27Kg
                                                        BHC SERIES(1P/2P 20-40 FLA)
Coil Rating                           1 Pole Contactors                                 2 Pole Contactors
Nominal Coil Voitage            24         120       208/240        277          24       120        208/240       277
Nominal Coil Resistance Ohms    18         420        1800        2500           11       237         1000     1600
Maximum Pick Up Voltage         18          88         177          221          18        88         177          221
Minimum Drop Out Voltage       6-15        20-70     40-140       50-165         6-15    20-70       40-140    50-165
Nominal Inrush VA @ 50Hz        31          31         31           31           33        33          33          33
Nominal Inrush VA @ 60Hz        28          28         28           28           30        30          30          30
Nominal Sealed VA @ 50Hz        6           6           6           6             8        8           8           8
Nominal Sealed VA @ 60Hz        5           5           5           5            6.5      6.5          6.5         6.5
Maximum Coil Voltage            30         132         264          300          30       132         264          300
Electrical Rating
    Full          Resistive    Locked Rotor        Locked Rotor      Locked Rotor          Maximum Horsepower
   Load           Amps @         Amps @              Amps @            Amps @              Voltage      Single
   Amps           600 VAC      240/277 VAC           480 VAC           600 VAC                          Phase
                                                1 Pole Contactors
                                                                                               120             1
     20                30            120               100                 80                                  2
                                                                                               140
     25                35            150               125                 100                 120             1
                                                                                               140             2
     30                40            150               125                 100                 120             1
                                                                                               140             2
     40                50            200               180                 120                 120             1
                                                                                               140             2
                                                2 Pole Contactors
     20                30            120               100                 80                  120             2
                                                                                               140             3
     25                35            150               125                 100                 120             2
                                                                                               140             3
     30                40            150               125                 100                 120             2
                                                                                               140             3
     40                50            200               160                 120                 120             2
                                                                                               140             3
                                           BHC SERIES(1P/2P 20-40 FLA)
Ordering Information
BHC    - 1A -     20   -     024   D   M
                                                                                            OPTIONAL COVER:
                                           M   Indicates the addition of a cover for 1 & 2 Pole contactors up to 30
                                                                                                              FLA
                                                                                                TERMINATION:
                                                          D #10-32 combo screw with quad QC (20-30 FLA)
                                                                      Blank #14-4 lug with quad QC (40 FLA)
                                                                                               COIL VOLTAGE:
                                           024-24VAC;120-120VAC;208-208VAC;240-240VAC;277-277VAC
                                                                                            CONTACT RATING:
                                                                     20-20FLA;25-25FLA;30-30FLA;40-40FLA
                                                                                                    POLE FORM:
                                                                  1A-1P NO;2A-2P NO;3A-3P NO;4A-4P NO
                                                                                                         SERIES:
                                                                                                             BHC
1 Pole Dimensions (Inches)
2 Pole Dimensions (Inches)