The document is an operation manual for a weighing indicator, detailing its symbols, keyboard functions, and operational procedures. It covers power on/off, zeroing, tare functions, unit selection, and alarming functions, along with instructions for calibration and user settings. Additionally, it includes specifications and safety precautions for using the device.

Uploaded by

Reyna Escobar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
47 views6 pages

Indicador Bernalo X2 INOX

The document is an operation manual for a weighing indicator, detailing its symbols, keyboard functions, and operational procedures. It covers power on/off, zeroing, tare functions, unit selection, and alarming functions, along with instructions for calibration and user settings. Additionally, it includes specifications and safety precautions for using the device.

Uploaded by

Reyna Escobar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

WEIGHING TNDTCATOR

f7z,rrlole
Operation Manual

ALhS§¿CD §*ries
';;,],,t

,..,'t,l..trl.

i,, ,,

', '.:.§r.
1. Indicated Symbols and Keyboard operation mode, and for setting alarm number. At setting status, this key can be used for setting
mode key.
[UNITS/SHIFT] is used for changing units in ihe weighing -o¿". At setting status, this key can be
used as shift key.
2. Operation
l). Power on :

Turn on the power switch at the bottom. The display will show 0-F sequentially for several
seconds. Then the value of weighing will be zero, and enter weighing status.

2). Zeroing:
If the scale is not in zero mode before of weighing or if there is a minor (less than 4Yo of max

1). Indicated Symbols


capacity)weight displayed without anything on the pan, press IZERO/TARE - ] key to clear the
display.
¡E-3 1: Chargingbattery.
back the value ofweighing to zero (the indicator symbol appears) for accurate weighing operation.
[ZERO]: Scale is in ZERO mode,indicator appears .
3). Tare Function:
[TARE]: Scale is in TARE mode, indicator appears.
Put the basket onto the scale platform and press the IZERO/TARE - ]key, then the tare light will
[Stable]: when scale to be stablely.indicator appears.
After entering into counting mode,indicator appears. indicating, which means that the weight ofthe basket has been deducted. put on the goods begin
[PCS]:
weight.or if there have weight (over than 4%o of max capacity)displayed without anything on the
[HOLD]: After entering into hold mode,indicator appears.
pan,press[ZERO/TARE * ]key to clear the display.
[Kg,t;lb]: Scale is in which one mit,the indicator appears.
4). Units Selection:
2). Keyboard Select the current unit in üe weighing mode by press IINITS] key. There are four units (kg, lb,
[HOLD/*] In weighing modqpress IHOLDI key,the scale will keep the weight(4 times the and t) to be selected.
average )value dost not move for l0 seconds; 5). Weigh Check Setting:
If within lOseconds press the (HOLDI key again,the scale will return to weight state. Press [CHECKf abott 2 seconds.The display will show upper limit value and " HI " Symbol, press
ISHIFTI. [HOLD/- ] or [TARE/ZERO*] key to enter upper limit value. Press [MODE]again,
[TARE/ZERO-] OPress this key to retum the display to zero in case rhere is any zero drifting The display will show lower limit value and "L" Symbol, press [SH|FT]. I HOLD-] or
while unloaded or the weight'less thatt 4Yo of maximum capacity and ZERO indicator symbols ITARE/ZERO*] to enter upper limit value as well. Now Press IMODE] again to confirm and
appears. return weighing status. After such setting, if weigh check alarm has been turned on, the weigh
@When üe weight over than 4Yo of maximum capacity,press this key will be available and TARE check function will work. when total weigh is under lower limit value. beep sound slowly. [f over
indicator syrnbols appears. upper limit value, beep sound quickly. If between lower limit value and upper limit value, beep
doesn't sound.
[MR]is used for remember data .press it could save weight or total weight . 6).Alarming Function:
([MC) press [TARE]+[MR] key,when display already save weightBress it could delete it the a. Over load alarming: When the load on the platform is over 0.3% of maxim capaciry, the beep
annal. will sound and the display. will show '1:---OVR", and you müst remove the load from platform
[M+] is used for save current weight annal,and add current to total weight. immediately.
([PRINT]) is used for print function.press this key about 2secpnd into print function. b. Lovq battery alarming: When turn on the power voltage will check it.and display voltage
ICHECKA,fODE] is used for the altemation between normal counting mode and quantity check grade,when the Battery voltage not enough,on the window battery sign display one space,and
Battery sign flicker.when tum on the power have beep,must stop using the scale and recharge it
e).IPRTNT]
immediately.
A.print current weight.
During the recharge ,red sign light display,if finished after will display green light and switch off.
a.on the weight mode,press[PRlNT]key about 2seconds,windows will display
7).[Counting Mode]
" 666666"psefSHIFTl, IIIOLD / * lor[TARE/ZERO+]key input print password,press[MODE]
a.press[MoDE]key into counting mode,the window will display"sAp KG is the sample key make sure the passwordjf password right,will display"GOoD",then press[MODE]key d
number).
isplay"PRINT" begin print,finished print retum back to weight stage.
b.press[SHlFT]key to select samples number from 10, 2Q, 50, 100, 200, 500, 1000, 50
b.when the value is negative number that coculdn't print and press[PRINT] key useless.
00, and 10000 pieces.press[M+]key make sure.
c.select sample number after,windows will display "LoAD-c",put enough number of samp
I B.print weight record.
a.on the weight mode,press[MR]key display total weight,into display add stage.
les then press[M+]key to finish sample.
d.when finished sample number after
t When your press [MR]key about 2seconds display recorde and into display weight recorde
stage.
if select sample number right,windows will display "cxxxxxx"(X is current countin b.on the display record ,press[PRlNT]key,windows will display"666666",using[SHlFT], IHOL
g number) p/*l6r[TARE77g¡Q+]key input print password,press
[MoDE]key make sure the passwor
if windows display"-Q§¡-"it means the unit weight of sample not enough,(unit weight is d,if password right,will disptay"GOOD",press[MODE]key display"pRlNT', to begin prinr,pri
too small,less than scale division.)this time please press[M+] key select sample number a nt all weight record number after return back to weight stage.
gain.
c.on the display add weight,press [PR[NT]key,windows will display "66i,6666",ase tSHlFTl,
e.For assuring the scale precision,the unit weight don't less than division.
[gófO/:-]or[TARE/ZERO+Jkey input print password, press [MODE]keymake sure the p
f.During the Counting mode.press[MODE]key retum back to Weight stage.
assword,if password right,will display"GOOD", press[MODE]key display',pRlNT- to begin
8).[save/read weight record]
print the add total value,finished the print after retum back to weight stage.
a.on the Weight stage,press[M+]key to save current weight and add weight at the same ti
C.Remark.
me,windows will display ADD XXX(XXX means add weight)about2.5second after display
a:when make sure the password,tum off the.power before valid,during this time not need i
add after total weight,then back to weight stage. (when weight number is negative value
nput password again.
will don't save it).
b.During input password,if have 5seconds not press any key,that scale will auto retum bac
On the weight,stage,press [MR]key,display ADD XXX,XXX nreiur for weight
k to weight stage.
Time ,,then display weight number again.till on the last item.when the last
c.lf input the password is wrong,display"ERROR",press[MODE]key retum back on input p
weight display complete,display ADD UP ,that mean are will display the total weight.then
assword stage and try input it again.
back to weight stage.
d.lf input the password is right,display"GoOD",press[MODE]key begin print,press[SHlFT]k
b.on the weight stage,press[MR] key about 2second will display weight record,
ey to the window will display"666666",in1o amend password stage,
press [MR] key again,could display and read weight circulation.(on t¡is stage please don't
use[SHIFT],[H9¡]/-lor[TARE/ZERO+]key input new password,press[MODE]key gave it.
press .it for long time.)when your want back to weight mode,press
e.During input could press [MR]or[M+]key retum back to weight stage.
ISHIFT]key. J
c.on the display weight record or display add weight,press[MC]key(press [TARE]+[MR]key)
f.lnitialize password is 666666
1 3. Description Of Server Selection
the windows will display"ClR" and delete record. add weight
l).Connect loadéell,press the(TAREZEROland(MODElkey,switch on the scale,then loosen this
return back to weight mode.
two keys.
d'record the highest save value more than 4O,when record is full press[M+]key,the new we
The üsplay shows:
ight will cover with before record.
EE---=IX (X means zero fack range)
e.When display add,on the window will have one ¿rrrow indication to Mr,when display sin
press (UNITI keychoosen, \
gle record,on the window will have one a¡row indicator to M+ with flicker.
press (MODEI key to confirm and enter into next st€p
2).Choose capacity Into User selection mode,press IMODE] key select backlight on/off setting item.when
The display shows: display"LTXXX", ¿'xvx"'s current stage.press [SHIFT]key select it.
xx.xxx Press [MODE] key into nexr select item.
Press (UMTI key move the number position 2). Selection Of Weigh Check Alarming(..XXXXXX LIM")
press I-I and (-I keytoselectthecapacity There are two alarming modes ("oFF" and "oN") selectable. ..oN,, means weigh check alarmiñg
press IMRI key Choosing dot position is available, "OFF" means weigh check alarming isn,t available.
press ( MODE I key to confirm and enter into next step Press [MoDE] key to select the weigh check alarming statue, and select..on, or..off'by
[sHIFT]
3).Choosen accuracy value key.
The display shows:
-l 3jSetting after,switch on the scale again,this sefting will useful.
E--- xro«x
4)How to set the measurihg "unit":
Press (UNITI key to change the value
Press (MODEI key to confirm and enter into next step In normal,the user can choose the following combinations:
4).Choosen calibration weight value:. l. "kg"unit only. "kg"unit is the fundamental unit cbuldn't be closed.
The display shows: 2."kg"& "g"unit only
E- )oo«x I 3. "kg"& "lb"unit
press (UNITI key move the number position The setting steps as below:
press (*I and (-I keytoselectthenumber a' Enter the setting' mode,Press"MODE"key to choose the 'tnit"as the subject 3 different
press(MoDEIkeytoconfirm,thedisplay.t,ow@forADinnercÓde,when Combinations.
dislay that threp stable arrow appear it also " di " sounds.press I MODE I key to confirm and enter b. Press "Mode"key to choose the unit,i.e. ..1b,,or..g,,.
into next step c. Press"SHIFT'key to choose the unit is',ON',or..OFF..
5).Calibration (.After setting,please turn offthe power.
The display shows: e.When you re-tum on,the new setting units are effected.
E »orror_l for AD inner code 5. Remarks
At this time which should be put on the weight refer to the choosen, wheá dislay that
1). Both the display and the keyboard are waterproof. However, completely immersing the
three stable arrow appear it, press (MODEI confirm.the calibration procedure is finished. scale
into water may cause serious damage.
Swith ofland take offall the weight,then switch on,the scale can bu used.
6). Selection Of Units 2). When tum on the power voltage will check it.and display voltage grade,when the Battery
Tliis function is used for setting the default unit. The unit selected will be kept in the scale when voltage not enough,on the window battery sign display one space,and Battery sign flicker.when
tum on the scale each times. There are four units ( kg, lb, and t ) to be selected. turn on the power have beep,must stop using the scale and recharge it immediately.
The setting operation as follow. Press [MODE] key to select the desired unit, and select "on" or 3). As usual, you should keep the backlight off if the backlight is not necessary. you should
tum
"off'by tSHtrTl key . After flural uint is selected. Press [MODE] key to enter Power on statue offthe power when the scale is not used. Besides, you're requested to reclarge :t e sealed lead-acid
4. Description Of User Selection battery as frequently as possible.
Tum on the power switch at the bottom while hotding [TARE/ZERO*] key at same time to entei
4). Ifthe scale is used for a long period or is recharged over 12 hours but could not
user selection mode.
work for a long time, it means that the battery is over used. In this'case, you'ie requested to replace
l). Selection OfAuto Backlight Off.
üe battery or ask your local distributor for replacement
This item function is used select backlight ON/OFF. "ON" means backlight keeping on; ..OFF,'
means backlight keeping off "AUT'means automation,according your operation automation ON 5). Use the DC adapter designed by the manufacturer for the indicator. Other adapters may
cause
or OFF.the operation details is following: damage to the indicator.
6. Spwifications
l). Response: 3-5 seconds
2). Display: 6upits laage LED digits dirylay
3). Tare: lüPlo of capacity
4).Zero: 4o/oof @y
5). Overload atarn Auto softwme alarm overO. 3% of capacity
6). Over load capacity: Auto protect over 125% ofcapacity
7). Power source: DC 6V 4.5Ah rechargéable battery
AC220I/ÍÍJ(I0V5ü)mAadrytor
8). Temperature: Storage: -1G+50 C
Operatc G40C
9). Humidity: Storage: Sa/o-9üÁR.H.
Operafe: l(P/r80q/o R.H.
Unit Conversion.
l
lke 1000s '

llb 453.59237s
loz = 28-349523125g
r(ToLAXTNDTA) 11.66380389

Ioad Cell connections


The load cells ate
a¡e co¡necd round
Pin I +Excitation
,/9.
Pl¡2 Shield 1
/o o\u
Pin 3 +§ignal
2 qo9.
Pin 4 -Sisnal
Pin 5 - Sdre€n

T.Printer Connect show .


o
GND T)(D GND TXD