7
2
                                                CONTENTS
PRECAUTIONS ............................................... 4
PREFACE........................................................... 6
NAMES AND FUNCTIONS ........................... 6
INSTALLATION & CONNECTION ........... 7
CALIBRATION ................................................ 8
OPERATIONS................................................. 10
   1. General Weighing .........................................11
  2. Weighing with Tare ........................................11
  3. Counting Mode ............................................ 12
  4. Weight Comparison Function(HI/OK/LOW) . 13
  5. Print Out ..................................................... 15
  6. Battery Charge............................................. 16
  7. Set-up Mode................................................. 16
  8. User Mode ................................................... 17
ERROR MESSAGES ..................................... 18
SERIAL INTERFACE ................................... 18
SPECIFICATIONS......................................... 19
HOW TO INSTALL HDI Series................... 20
ASSEMBLING THE DISPLAY OF HDI
WALL TYPE .................................................... 21
                     3
PRECAUTIONS
              4
5
PREFACE
Thank you for the purchasing of CAS HDI Series.
This series have been designed with CAS reliability, under rigid quality control
and with outstanding performance. Your specialty departments can enjoy with
CAS products.
We hope that CAS product meets your needs.
The user manual is designed to guide you to understand product operation and
proper care of product.
NAMES AND FUNCTIONS
OVERALL VIEW
 HDI
                                     6
INSTALLATION & CONNECTION
Load cell connection
Connect load cell connector to load cell port which is in the backside of the indicator.
* Connecting method
                                                              IN                 COLOR
                                                         1 (EXC+)                RED
                                                          2 (EXC-)              WHITE
                                                          3 (SIG+)              GREEN
                                                          4 (SIG-)              BLUE
                                                        5 (SHIELD)              SHIELD
Note. Wire color can be different depending on the
      loadcell’s manufacturer or it’s model.
* Load cell output to Resolution
         5V impression to loadcell
                                                       Recommended resolution
           Max. load cell output
                    4 mV                                             1/4,000
                    8 mV                                             1/8,000
                    10 mV                                            1/10,000
                                           7
CALIBRATION
- Product initialization
Press       key to go to Power on
                    When numbers on the display appears press CAL S/W.
                    There will be a beeping sound as the product initializes.
- General Calibration
* If the product initiation process is skipped, the #4 value will automatically be set to the
previously set value and the setup process will be skipped.
1. Pressing and holding calibration switch press        key to go to calibration mode.
2. Pressing and holding                 key press        key to go to calibration mode.
3.
                              key : Quick value settings. “1/2/5/10/20/50/DUAL”
                             Select
4.                            key : Set-point digits
                                    “00000/0000.0/000.00/00.000/0.0000/0.00000”
                             Select
5.                                  key : Full Capa. Setting (Input values are converted to grams
*When the quick value setting is Dual “ 3060 : 30-60kg , 6015: 60-150kg , 1530: 150-300kg”
                                    Select
                                             8
  Calibration mode
   Zero Calibration (Check that the scale reads zero)
           Span Calibration Input value. Note: Input values in Kg.
Place the previously inputted amount of weight on the scale and then
press       Select
Calibration complete
                           9
OPERATIONS
DISPLAY AND KEYBOARD
KEY FUNCTIONS
     KEYS                                    DESCRIPTIONS
                Used to set the zero point to 0.00.
                Used as an ESC key in Setup Mode.
                Used to enter a tare weight and used to cancel a tare weight.
                Used to convert the mode as below.
                [kg]  [pcs]  [%] [WEIGHT LIMIT ON/OFF] 
                [COUNT LIMIT ON/OFF]  [kg]
                Used as an ENTER key.
                Used to calculate a unit weight of a sample..
                [▶] Used to enter next digit.
                Used to display average weight.
                [    ] Used to have number up.
                PRINT key.
                [▼] Used to have number down.
                Used to turn ON or OFF the power.
                                   10
1. General Weighing
 ■ The display indicates if the scale is at zero or if there is a tare entered into the
 scale by way of a ZERO and NET.
 ① Turn on the power.                 ② When the display is not zero         ③ Place an item on the platter.
 The display shows 0.00.              though there is nothing on             When the STABLE lamp is
 Make sure that STABLE and            the platter, press the ZERO            on, read the weight.
 ZERO lamps are on.                   key.
2. Weighing with Tare
 ■ Tare is the weight of container being used for a commodity.
 The TARE key subtracts the weight of the container.
 ① Place the container on the         ② Press the TARE key, NET              ③ Place an item in the
 platter.                             lamp is on.                            container.
                                    ④ To release the TARE function, remove an item and
                                    container from the platter and press the TARE key.
                                                  11
3. Counting Mode
■ Samples on the platter.
 ① Press the MODE key until            ② Press the SAMPLE key,               ③ If you want to increase
 the display shows “WL OFF”.           then the display shows “10”.          sample size, press the
 If you have set sample size                                                 SAMPLE key. The display
 before the display shows “0”.                                               shows 10, 20, 50, 100, 200
                                                                             every time pressing the
                                                                             SAMPLE key.
④ If you set sample size to 10, place 10 samples on the platter.
⑤ Press the SET key. The display shows unit weight and then shows the number of samples. If the
display shows “LACK”
* The small value that can escape from ‘LACK’ message is over MAX CAPA / 3000.
    a. unit weight ≤ 0.8 e *
    b. weight load ≤ 2% of maximum weighing capacity.
                                        ⑥ Place parts on the platter, then the display shows the number
                                            of parts. You can also use tare function in counting mode.
                                                12
4. Weight Comparison Function(HI/OK/LOW)
① Press the MODE key until       ② Press the SAMPLE key to        ③ Press the SET key to set up
the display shows “WL OFF”.      activate this function, the      low value, the display shows
It means that weight limit       display shows “WL ON”.           “000.00”.
function is deactivated.
④ Press the HOLD(▲) or           ⑤ Press the SET key to set up    ⑥ Press the HOLD(▲) key
PRINT(▼) key to have             high value, the display           to have number up or
number up or down. To enter      shows “H000.00”.                  down. To enter
next digit, press the SAMPLE                                      next digit, press the
key.                                                              SAMPLE (▶) key.
                               ⑦ Press the SET key, the display shows “End”.
                                             13
⑧ If you set up LOW/HIGH limit wrong, “WL ERR” will be shown on the display. Then you have to set it
up again. For example) LOW=100.00kg HIGH=90.00kg  High limit is lower than Low limit.
⑨ Press the MODE key to go to weighing mode.
⑩ Suppose that the High limit of 70kg and the Low limit of 30kg are set up. In this condition, OK lamp is
lighted on if the weight is 40kg, HI lamp is lighted on if the weight is 80kg and if the weight is 20kg,
LO lamp is lighted on. It beeps as fixed on User Setup Mode.
                                              14
5. Print Out
5-1. Manual Print
  ■ You can print out data every time pressing the PRINT key. You can setup
  print function depends on your need. Refer to User Mode Table on page 17.
5-2. Auto Print
① To use auto print function, you have to set printer method = 1 in User mode.
Refer to User Mode Table on page 17.
② If the weight is stable, it is printed out automatically.
And You can print out data every time pressing the PRINT key.
5-3. Stream Print
① To use auto print function, you have to set printer method = 2 in User mode.
Refer to User Mode Table on page 17.
② If the weight is stable, it is printed out continuously
    < Print Format>
  12.000 Kg
  15.000 Kg
           .
           .
           .
                                                     15
6. Battery Charge
■ Warning massage is shown when the battery voltage is very low. (            )
■ At this time, charge the battery.
■ The display will show a red lamp and the battery will begin a fast charge
 automatically.
- Use only the ac adapter which comes with the scale. Other AC adapter may
  cause damage.
7. SET-UP MODE
Pressing and holding                  key press    key to go to set-up mode.
(a)    (b)   (c) (d)    (e)   (f)
(a)   Zero Tracking            0 ~9d
(b)   Minimum Tracking Digit 0 ~9d
(c)   Measure of weight after zero tracking 0 ~9d
(d)   Initial Zero Range      0 =20% 1 =100%
(e)   Vibration Filter       0 =high        1 =middle             2 =low
(f)   0 = Colon 1 =Semicolon
Default: 123100
        Zero Tracking : 1d
        Minimum Tracking Digit : 2d
        Measure of weight after zero tracking : 3d
       Initial Zero Range : 1 = 100% ,      Vibration Filter : 0 = high ,         0 = Colon
                                              16
8. User Mode
Pressing and holding         key press        key to go to user mode.
(a)   (b)   (c) (d)    (e)   (f)
(a) Backlight: 1 – Auto , 2 – On , 3 - Off
(b) Auto Power Off : 0 - off , 1 – 10min , 2- 30min , 3- 60min
(c) Unit of measure : 0 – Kg, 1- lb
(d) Baud Rate :       0 =4800 1 =9600 2=19200
(e) Print method : 0 = Auto print when the scale is stable
                      1 = Print continually when the scale is stable
                      2 = Manual print
(f) Not Use
Default : 100120
          Backlight : 1-Auto
          Auto Power Off : 0 – Off
          Unit of measure : 0 – Kg
          Baud Rate : 1- 9600bps
          Print method : 2 – Manual print
                                               17
ERROR MESSAGES
  Error
 Message                     Description                                  Solution
on Display
  “Err 0”    The "Err 0" occurs when scale is not stable.    Remove unstable facts.
             The "Err 1" occurs when a current zero point
  “Err 1”                                                    Please call your CAS dealer.
             has shifted from the last span calibration.
  “Err 3”    The "Err 3" is an overload error.               Please remove the weight.
             The "Err 9" is no weight error. When scale is
             in counting mode, you must load the weight.
 “Err 9”                                                     Please load the weight on your tray.
             If you have no weight on your scale, you can
             see this error message.
             The "Err 14" means calibration range is not
 “Err 14”                                                    Please call your CAS dealer.
             correct.
SERIAL INTERFACE
                                       18
SPECIFICATIONS
 Load Cell Excitation
                                                      DC 5 V
 Voltage
 Zero Adjustment
                                                 0.05 mV ~ 5 mV
 Range
 Input Sensitivity                                    2 uV/D
 A/D
                                                     1/300000
 Internal Resolution
 A/D
                                                     1/30000
 External Resolution
 Division                                 X1, x2, x5, x10 , x20 , x50
 A/D
                                                      10 Hz
 Conversion Speed
 Display Below Zero                                   Minus
 DISPLAY                             LCD 6 digits 110mm(W) X 35mm(H)
                                 STABLE, ZERO, HOLD, NET, HI/OK/LO, lb,
 DISPLAY LAMP
                                         , PCS, kg, Low Battery
 INTERFACE                                       RS-232C(Printer)
                                               DC 12 V 1.25 A Adaptor
 POWER SOURCE
                                                6 V 4 Ah Pb Battery
 TEMPERATURE
                                                 -10 °C ~ +40 °C
 RANGE
 PRODUCT SIZE
                                           220(W)X159(D)X107(H)
 (WDH)mm
 PRODUCT
                                                      1.5 kg
 WEIGHT
 MINIMUM
 VOLTAGE LEVEL                                     About 5.6 V
 OF THE BATTERY
 CONTINUOUS                            About 100 Hours(Back light Off)
 USING TIME                            About 25 Hours(Back Light On)
                        *The load Cell Specification can have an effect on using time.
 RECHARGING                                      About 12 Hours
▶Notice: Specifications are subject to change for improvement without notice.
                                          19
HOW TO INSTALL HDI Series
1. Open the box with care because indicator is connected to the scale with
   load cell wire.
2. Turn the post knob so as to fix indicator.
3. Pull down the wire out of post pipe and insert the post pipe to the post
   bracket. (Refer to fig. 1)
4. Fasten the post pipe with two bolts. (Refer to fig. 1)
   A long bolt should be connected to the upper side.
5. Insert the wire to the post pipe. (Refer to fig. 2, 3)
6. If the scale is not properly level, please adjust 4 leg (adjusting bolt) at the
   bottom of the scale so as to center the bubble of the leveling gauge.
※ Note : Place the scale on a flat and stable surface.
         Inside the indicated circle.
                                             20
ASSEMBLING THE DISPLAY OF HDI WALL TYPE
1. Attach head bracket to the display and fasten it with screws provided as shown in Figure. 1.
2. Connect both of grand wire and load cell wire to load cell connector at the backside of display
   as shown in Figure. 2.
3. Fasten grand wire to the bottom of platform body with bolt as shown in Figure. 3.
                                                21
MEMO
22
뒷표지
      23