D1FB Uk
D1FB Uk
3
D1FB for external electronics:
D1FB D1FB OBE
The parameters can be saved, changed and duplicated in
combination with the digital power amplifier PWD00A-400.
The valve parameters can be edited with the common
ProPxD software for both versions. A B A B
The D1FB valves can be ordered with spool/sleeve design
(D1FB*0) for maximum precision as well as spool/body a 0 b a 0 b
design (D1FB*3) for high nominal flow - see functional P T P T
limit curves for maximum flow capability.
Valves with explosion proof solenoids Ex e mb ll see
catalogueMSG11-3343.
Download: www.parker.com/ISDE, see “Support” D1FB D1FB OBE
Features
• Spool/sleeve and spool/body
• 3 command options for D1FB OBE:
+/- 10 V, 4…20 mA, +/- 20 mA
• High repeatability from valve to valve
• Low hysteresis
• Manual override
• Digital onboard electronics
Parametrizing connection
Main connection
(always on B-side)
Manual
override
A B A B
D1FB
D 1 F B 0 N
Directional Size Proportional Standard Spool Spool Seals NBR Solenoid Connector Design Design
control DIN NG06 control dynamics type position (other seal series
valve CETOP 03 standard compounds (not required
on request) for ordering)
NFPA D03 repeatability
D 1 F B 0 N
Directional Size Proportional Standard Spool Spool Seals NBR Input Options Design Design
control DIN NG06 control dynamics type position (other seal signal series
valve CETOP 03 standard compounds (not required
on request) for ordering)
NFPA D03 repeatability
General
Design Direct operated proportional DC valve
Actuation Proportional solenoid
Size NG06/CETOP 03/NFPA D03
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTFD value 1) [years] 150
Weight (OBE) [kg] 2.2 (2.9)
Hydraulic
3 Max. operating pressure
Max. pressure drop PABT / PBAT
[bar] Ports P, A, B 350; Port T 210
[bar] 350
Fluid Hydraulic oil according to DIN 51524 ... 535, other on request
Fluid temperature [°C] -25...+60
Viscosity permitted [cSt] / [mm2/s] 20...400
recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406; 18/16/13
D1FB*0 (Spool/sleeve) D1FB*3 (Spool/body)
Nominal flow at ∆p = 5 bar
per control edge 2) [l/min] 6/12/20 10/20/30
Leakage at 100 bar [ml/min] <50 <60
Opening point (OBE) [%] see flow characteristics (set to 10 command signal)
Static / Dynamic
Step response at 100 % step [ms] 30 30
Hysteresis [%] <4 <6
Temperature drift solenoid current [%/K] <0.02
Electrical characteristics
Duty ratio [%] 100 ED; CAUTION: Coil temperature up to 150 °C possible
Standard (as per EN 175301-803) IP65 in accordance with EN 60529 (with correctly mounted
Protection class plug-in connector)
DT04-2P “Deutsch“ IP69K (with correctly mounted plug-in connector)
Code "J"
Solenoid Code "M" Code "K"
(Spool/sleeve)
Supply voltage [V] 9 12 24
Current consumption [A] 2.7 2.2 1.1 (0.8)
Resistance [Ohm] 2.7 4.4 18.6
Connector as per EN 175301-803 (code W), DT04-2P “Deutsch“ connector (code J).
Solenoid connection
Solenoid identification as per ISO 9461.
Wiring min. [mm²] 3x1.5 (AWG 16) overall braid shield (Code W), "Deutsch" connector DP4 2-Pin (Code J)
Wiring lenght max. [m] 50
1) If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve elec-
tronics voltage supply is to be switched off by a suitable switching element with sufficient reliability.
√
2)
Flow rate for different ∆p per control edge: Qx = QNom. · ∆px
∆pNom.
Flow characteristics
D1FB*0 external electronics
at ∆p = 5 bar per metering edge
Spool type E01/02/03, B31/32
100 100
Flow Q [% of nominal flow]
75 75
A-T P-A
3
50 50
P-B P-A
A-T B-T P-B B-T
25 25
0 0
100 -80 -60 -40 -20 0 20 40 60 80 100 100 -80 -60 -40 -20 0 20 40 60 80 100
Command signal [%] Command signal [%]
D1FB*0 OBE
(set to opening point 10 %)
at ∆p = 5 bar per metering edge
Spool type E01/02/03, B31/32
100 100
Flow Q [% of nominal flow]
75 75
A-T P-A
50 50
P-B P-A
A-T B-T P-B B-T
25 25
0 0
100 -80 -60 -40 -20 0 20 40 60 80 100 100 -80 -60 -40 -20 0 20 40 60 80 100
Command signal [%] Command signal [%]
Functional limits
at 25 %, 50 %, 75 % and 100 % command signal At asymmetric flow a reduced flow limit has to be con-
(symmetric flow) sidered.
Spool type E01H
40
Flow Q [l/min]
A B
100 %
30 P T
75 %
20
10 50 %
25 %
0
0 50 100 150 200 250 300 350
Pressure drop p P–T [bar]
Flow characteristics
D1FB*3 external electronics
at ∆p = 5 bar per metering edge
Spool type E01/02/03, B31/32
100 100
Flow Q [% of nominal flow]
75 75
A-T P-A
50
P-B
A-T
P-A
B-T
50
3
P-B B-T
25 25
0 0
100 -80 -60 -40 -20 0 20 40 60 80 100 100 -80 -60 -40 -20 0 20 40 60 80 100
Command signal [%] Command signal [%]
D1FB*3 OBE
(set to opening point 10 %)
at ∆p = 5 bar per metering edge
Spool type E01/02
100 100
Flow Q [% of nominal flow]
75 75
P-B P-A
A-T B-T A-T P-A
50 50
P-B B-T
25 25
0 0
-100 -80 -60 -40 -20 0 20 40 60 80 100 -100 -80 -60 -40 -20 0 20 40 60 80 100
Command signal [%] Command signal [%]
Functional limits
at 25 %, 50 %, 75 % and 100 % command signal At asymmetric flow a reduced flow limit has to be con-
(symmetric flow) sidered.
Spool type E01K
70
Flow Q [l/min]
A B
60
50 P T
40
100 %
30
75 %
20
10 50 %
25 %
0
0 50 100 150 200 250 300 350
Pressure drop p P–T [bar]
Reference Reference
command E command E
F0: 0...+/-10 V µC G0: 0...±20 mA µC
D S0: 4...12...20 mA D
potentiometer-
supply
3
+10 V C
-10 V F
0V 0V
G A B G A B
supply supply
PE voltage PE voltage
18...30 V= 18...30 V=
Code W5
11 + PE acc. to EN 175201-804
preset
recall
S1 S2 S3 S4
6 7 8 11
Reference
command 5
W5: 0...+/-10 V µC
4
potentiometer-
supply
+10 V 9
-10 V 10
0V
4
5
3 10 6
1 2
2 9 11 7
supply
1 8 voltage
PE
18...30 V=
D1FB*C
15
79.5
Ø9.5
22
P
Ø5.5
3 P
46
A B
T
72.5 17
222
D1FB*E D1FB*K
15
15
79.5
79.5
Ø9.5 Ø9.5
~53
~53
22
22
P P
Ø5.5 Ø5.5
P P
46
46
A B A B
T T
72.5 17 17 132
158 158
Ø9.5
71.3
68
22
P
Ø5.5
P
46
A B
T
72.5 17
222
D1FB*C OBE
125
Ø9.5
22
P
Ø5.5
46
A B
T
72.5 17
222
125
Ø9.5 Ø9.5
22
22
P P
Ø5.5 Ø5.5
P P
46
46
A B A B
T T
72.5 17 17 132
158 158