BILL OF QUANTITY
NIT No- Year 2024-25 Group No-
Bill of Quantity for :- #REF!
Estimated cost :- #REF!
Earnest money :- 99400.00
Cost of BOQ :- 5000.00
Time of Completion (in months) :- 03 Months
30.01.2024 to 05.02.2024
Date of sell of BOQ :- Time : Upto 3:00pm
06.02.2024
Date & Time for Receipt Tender :- Time : Upto 3:00pm
09.02.2024
Date & Time of Opening Tender :- Time : Upto 3:30pm
No. of Items:- 53
Authority for Receiving Tender:-
i Superintending Engineer
L.A.E.O Work Circle Saharsa
ii Executive Engineer
L.A.E.O Work Div. Madhepura
iii Assistant Engineer
L.A.E.O Work Div. Madhepura
Sl.No.SR Ref. Item of Work Unit Qty Rate Amount
Civil Works
1 2.29 Surface dressing of the ground including removing
vegetation and
inequalities not exceeding 15 cm deep and disposal of
rubbish, lead
upto 50 m and lift upto 1.5 mAll kinds of soil
2.29.1 All Kinds of soil %sqm #REF! #REF! #REF!
EARTH WORK
Sl.No.SR Ref. Item of Work Unit Qty Rate Amount
2 2.8 Earth work in excavation in foundation trenches or
drains(not exceeding 1.5 m in width or 10 sqm on plan)
including dressing of sides and ramming of bottoms, lift
upto 1.5 m . Including getting out the excavated soil
and disposal of surplus excavated soil as directed,
within a lead of 50 m.
2.8.1 All Kinds of soil cum #REF! #REF! #REF!
3 2.26 Filling available excavated earth (excluding rock) in
trenches,plinth, sides of foundations etc. in layers not
exceeding 20 cm indepth: consolidating each deposited
layer by ramming and watering lead cum #REF! #REF! #REF!
4 2.28 Supplying and Filling in plinth with local sand and
under floors including, watering, ramming consolidating
and dressing complete cum #REF! #REF! #REF!
5 6.1A+ Brick work with bricks of class designation 100A in
6.1.14A foundations and plinth in :Cement mortar 1:6 (1
cement: 6 coarse sand ) cum #REF! #REF! #REF!
6 6.1.14A Brick work with bricks of class designation 100A in
+6.3A foundations and plinth in :Cement mortar 1:6 (1
cement: 6 coarse sand ). Extra for Brick work in
superstructure above plinth level upto floor V cum #REF! #REF! #REF!
7 4.1.3 Providing and laying in position cement concrete of
specified grade exluding the cost of centring and
shuttering-all work upto plinth level. 1:2:4(1 Cement: 2
coarse sand:4 graded stone aggregate 20 mm nominal
size) cum #REF! #REF! #REF!
8 5.1.2 Providing and laying in position specified grade of
reinforced cement concrete excluding the cost of
centring,shuttering,finishing and reinforcement-All work
puto plinth level. 1:1.5:3(1 cement: 1.5 coarse sand:3
graded stone aggregate 20 mm nominal size)
cum #REF! #REF! #REF!
9 5.2.2 Reinforced cement concrete work in wall (any
thickness),including attached pilasters, buttresses,
plinth and string courses, fillets, columns, pillars, piers,
abutments, posts and
cum #REF! #REF! #REF!
10 5.3+ Reinforced cement conrete work in beams,suspended
5.33B4 floors,roofs having slope upto 15, landings,balconiec,
shelves,chajjas, lintels, bands, plain window sills,
staircases and spiral stair cases upto floor five level
excludingthe cost of 1 cement:2 coarse sand:4graded
stone aggregate 20 mm nominal size).
cum #REF! #REF! #REF!
11 5.22.7 Reinforcement for R.C.C. work including
straightening,cutting, bending, placing in position and
binding all complete.
Tor 8 mm kg #REF! #REF! #REF!
Tor 10 mm kg #REF! #REF! #REF!
Tor 12 mm kg #REF! #REF! #REF!
Tor 16 mm kg #REF! #REF! #REF!
Sl.No.SR Ref. Item of Work Unit Qty Rate Amount
Centering and Shuttering
12 4.3.1 Centring and shuttering including strutting,propping
etc.and removal or form work for foundations,footings,
bases Columns sqm #REF! #REF! #REF!
13 5.9.1 Centring and shuttering including strutting,propping etc.
and removal of form for. Foundations, footings, bases
of columns etc. formass concrete. sqm #REF! #REF! #REF!
14 5.9.3 Centering and shuttering in Suspended floors, Landings sqm #REF! #REF! #REF!
15 5.9.5 Centering and shuttering in Plinth beam, major Lintel,
Roof Beam sqm #REF! #REF! #REF!
16 5.9.6 Centering and shuttering for Stiffners sqm #REF! #REF! #REF!
17 5.9.7 Centering and shuttering in Stair Waist Slab sqm #REF! #REF! #REF!
18 5.9.19 Centering and shuttering in Chajja sqm #REF! #REF! #REF!
DOORS AND WINDOWS
19 10.5.1 Providing and fixing 1 mm thick M.S.sheet gate with
frame of 40x40x6 mmangle iron and 3mm MS gusset
plates at the junction and corners.allnecessary fittings
completejncluding applying a priming coat of approved
steel primer. sqm #REF! #REF! #REF!
20 9.48.1 Providing and fixing M.S. grills of required pattern in
frames of windows etc. with M.S. flats, square or round
bars etc. including priming coat with approved steel Kg #REF! #REF! #REF!
primer all complete.
21 1549 Providing and fixing G.I. pipes 40 mm dia pipe ….etc
all comp
m #REF! #REF! #REF!
22 10.18 Providing and fixing circular cast iron box for ceiling fan
clamp 140 mm internal dia, 73 mm height, 5 mm thick
rim bottom and top lids, 1.5 mm thick M.S sheet with its
top surface hacked for proper bonding top lid shall be
screwed into the cast iron box by means of 3.3 mm dia
round headed screws, one ;pcf at the corners. Clamps
shall be made of 12 mm dia M.S. bar bent to shape as
per standard drawing. nos #REF! #REF! #REF!
FLOORING WORK
23 11.72 Providing designation 100 A one brick flat soling joints
filled with local sand including cost of watering, taxes,
royalty all complete as per building specification and
direction of E/l,
sqm #REF! #REF! #REF!
24 11.26.1 Kota stone slab 20 to 25 mm thick - flooring over 20
mm (average ) thick base laid overand jointed with grey
cement slurry mixed with pigment to match theshade of
the slab including rubbing and polishing complete .
Base with1:1:1 (1 lime : 1 surkhi: 1 coarse sand ) / 1:4
(1 cement: 4 coarse sand
)
sqm #REF! #REF! #REF!
Sl.No.SR Ref. Item of Work Unit Qty Rate Amount
25 11.27 Kota stone slabs 20 mm thick in risers of steps skirting.
Dado & pillarslaid on 12 mm (average (thick cement
mortar 1:3 (1 cement: 3 coarsesand ) and jointed with
grey cement slurry mixed with pigment to matchthe
shade of the slab including rubbing and polishing
complete. Detailsof cost for 10 sqm
sqm #REF! #REF! #REF!
26 10.16.1 Steel work in built up tubular Hot finished welded type
tubes(round, square or rectangular hollow tubesetc.)
trusses etc., including cutting, hoisting, fixing in position
and applying a
priming coat of approved steel primer, including
welding and bolted withspecial shaped washers etc.
complete
kg #REF! #REF! #REF!
27 12.1.3 Providing corrugated 0.63 mm thick with zinc coating
not less than 275 gm/m2 G.S. sheet roofing including
vertical / curved surfacefixed with polymer coated J or
L hooks, bolts and nuts 8 mm diameter withbitumen
and G.I. limpet washers or with G.I. limpet washers
filled with whitelead, including a coat of approved steel
primer and two coats of approvedpaint on overlapping
of sheets complete (up to any pitch in horizontal/ sqm #REF! #REF! #REF!
PLASTER WORK
28 13.11.4 Cement plaster in course sand.12 mm cement plaster
1:6 (outside surface) sqm #REF! #REF! #REF!
29 13.12.4 15 mm cement plaster 1:6 (inside surface) sqm #REF! #REF! #REF!
30 13.24.2 6 mm cement plaster 1:4 in ceiling sqm #REF! #REF! #REF!
31 13.17.1 12 mm plaster 1:3 with cement punning sqm #REF! #REF! #REF!
32 13.11.1 12 mm water proofing mix cement plaster 1:3 …..etc
& all comp
13.36.1 sqm #REF! #REF! #REF!
FINISHING WORK
33 13.78.1 Finishing walls with water proofing cement paint of
& approved brand and manufacture and of required
13.79.1 shade to give an even shade New work (three or more
coats) with Applying one coat of cement primer of
sqm #REF! #REF! #REF!
approved brand and manufacture on wall surface
34 13.93.1 Painting with synthetic enamel paint of approved brand
andmanufacture to give an even shade:Two or more
coats on new work sqm #REF! #REF! #REF!
35 NSR Carriage of Materials
Bricks %o #REF! #REF! #REF!
Stone Chips cum #REF! #REF! #REF!
Coarse Sand cum #REF! #REF! #REF!
Local Sand cum #REF! #REF! #REF!
36 NSR Difference Cost of
Materials
Bricks %o #REF! #REF! #REF!
Cement bags #REF! #REF! #REF!
Sl.No.SR Ref. Item of Work Unit Qty Rate Amount
37 NSR Difference of GST 18% instead of 12% (multiplying
factor 0.063307) 1 #VALUE! #VALUE!
38 NSR Supplying, fitting and fixing of informatory sign board,
shilanyas and udghatan shilapatt of granite black stone
all complete as per direction of E/I. Each #REF! #REF! #REF!
39 NSR Supplying, fitting and fixing of whiteboard for Class
Room…..etc all complete as per direction of E/I. Each #REF! #REF! #REF!
40 NSR Add seigniorage
Charge
Bricks %o #REF! #REF! #REF!
Stone Chips 10mm cum #REF! #REF! #REF!
Coarse Sand cum #REF! #REF! #REF!
Local Sand cum #REF! #REF! #REF!
ELECTRIFICATION WORKS Rate as per S.O.R. of B.C.D Patna Effective Date -01-09-2023
41 1.3.3 Wiring for light point/ fan point/ exhaust fan point / call
bell point with 1.5 Sq.mm FR PVC insulated copper
conductor cable in recessed PVC conduit with modular
type switch , modular plate, suitable size GI box etc
as required. Group 'C'
pt 8.00 1146.00 9168.00
42 1.31 Supplying and fixing suitable size GI box with modular
plate and cover in recess including providing and fixing
modular type 3 pin 5/6 amps socket outlet & 6A switch
connection etc. as required.
Each 5.00 414.00 2070.00
43 1.5 Wiring for light/ power plug plug with 2 X 4 sq. mm FR
PVC insulated copper conductor single core cable in
surface / recessed medium class PVC conduit along
with 1 Nos 4 sq. mm FR PVC insulated copper
conductor single core cable for loop earthing as
required
m 5.00 309.00 1545.00
44 1.33 Supplying and fixing 2 pin, 6 amp ceiling rose on the
existing junction box/ wooden block including
connection etc as required.
Each 5.00 64.00 320.00
45 1.34 Supplying and fixing Batten/angale holder on the
exisiting jucction box/pvc box including connection etc.
as required.
Each 6.00 80.00 480.00
46 1.7 Wiring for circuit/ submain wiring alongwith earth wire
withthe following sizes of FRLS PVC insulated copper
conductor,single core cable in surface/ recessed
medium class PVCconduit as required.
1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire m 30.00 201.00 6030.00
1.7.2 2X2.5 sq. mm + 1X 2.5 sq. mm earth wire m 20.00 246.00 4920.00
1.7.11 4 X 6 sq. mm + 1 X 6 sq. mm earth wire m 15.00 660.00 9900.00
47 2.9.1 Supplying and fixing 4 way ( 4 + 12 ), double door,
horizontal typefollowing way, horizontal type,three pole
& neutral, sheet steel, MCB distribution board, 415
volts, on surface/ recess, complete with tinned copper Each 1.00 4184.00 4184.00
bus - bar, neutral bus bar, earth bar, din bar,
Sl.No.SR Ref. Item of Work Unit Qty Rate Amount
48 2.12 Supplying and fixing following rating, 240/415 volts,
"C" curve, miniature circuit breaker suitable for
inductive loads of following poles in the existing MCB
DB complete with connections, testing and
commissioning etc. as required.
2.12.1 6 Amp. To 32 Amp. SP MCB Group-B 240 Volt Each 5.00 237.00 1185.00
2.12.7 40/63 Amps, Tripole pole and neutral Each 1.00 1859.00 1859.00
49 6.1.6 Supplying and fixing of following types lamp in the
existing electrical fitting/ fixtures etc. as required 15watt
LED lamp Each 5.00 250.00 1250.00
50 8.15 Supply and installation of regular/standard model A.C.
ceiling fan of 1200 mm sweep including wiring the
down rods of standard length (upto 30 cm) with 1.5 sq.
Each 2.00 2482.00 4964.00
51 1.25 Supplying and fixing stepped type electronic fan
regulator on the existing modular plate/ switch box
including connections but excluding modular plate
etc.as required.
Each 2.00 358.00 716.00
52 3.6 Earthing with copper earth plate 600 mm X 600 mm X
3 mm thick including accessories, and providing
masonary enclosure with cover plate having locking
arrangement and watering pipe 2.7 metre long etc. with
charcoal/ coke and salt as required.
Each 0.00 13721.00 0.00
53 3.17 Providing and fixing 4.00 mm dia copper wire on
surface or in recess for loop earthing etc. as required.
m 5.00 144.00 720.00
Total Rs #REF!
INTERNAL ELECTRIFICATION OF
#REF!
Items Covered Under BCD-Electrical SOR-2023 Effective From 01.09.2023
Sl. No. SOR Rate Amount
Code.
Description of Work Unit Qty.
(Rs.) (Rs.)
Electrical Works
1 1.3 Wiring for light point/ fan point/ exhaust fan point / call bell point
with 1.5 Sq.mm FR PVC insulated copper conductor cable in
recessed PVC conduit with modular type switch , modular plate,
suitable size GI box etc as required.
1.3.3 Group C Point 8.00 1146.00 9,168.00
2 1.31 Supplying and fixing suitable size GI box with modular plate Each 5.00 414.00 2,070.00
and cover in recess including providing and fixing modular type
3 pin 5/6 amps socket outlet & 6A switch connection etc. as
required.
3 1.5 Wiring for light/ power plug plug with 2 X 4 sq. mm FR PVC meter 5 309.00 1,545.00
insulated copper conductor single core cable in surface /
recessed medium class PVC conduit along with 1 Nos 4 sq. mm
FR PVC insulated copper conductor single core cable for loop
earthing as required
4 1.33 Supplying and fixing 2 pin, 6 amp ceiling rose on the existing Each 5.00 64.00 320.00
junction box/ wooden block including connection etc as
required.
5 1.34 Supplying and fixing Batten/angale holder on the exisiting Each 6.00 80.00 480.00
jucction box/pvc box including connection etc. as required.
6 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the
following sizes of FR PVC insulated copper conductor, single
core cable in surface/ recessed medium class PVC conduit as
required.
1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Meter 30.00 201.00 6,030.00
1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Meter 20.00 246.00 4,920.00
1.7.11 4 X 6 sq. mm + 1 X 6 sq. mm earth wire Meter 15.00 660.00 9,900.00
7 2.9 Supplying and fixing following way, horizontal type,three pole &
neutral, sheet steel, MCB distribution board, 415 volts, on
surface/ recess, complete with tinned copper bus - bar, neutral
bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without
MCB/RCCB/Isolator
2.9.1 4 way ( 4 + 12 ), double door, horizontal type Each 1.00 4184.00 4,184.00
8 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve,
miniature circuit breaker suitable for inductive loads of following
poles in the existing MCB DB complete with connections,
testing and commissioning etc. as required.
2.12.1 6 Amp. To 32 Amp. SP MCB Group-B 240 Volt Each 5.00 237.00 1,185.00
2.12.7 40/63 Amps, Tripole pole and neutral Each 1.00 1859.00 1,859.00
9 6.1.6 Supplying and fixing of following types lamp in the Each 5.00 250.00 1,250.00
existing electrical fitting/ fixtures etc. as required. 15 watt LED
lamp
10 8.15 Supply and installation of regular/standard model A.C. ceiling Each 2.00 2482.00 4,964.00
fan of 1200 mm sweep including wiring the down rods of
standard length (upto 30 cm) with 1.5 sq.
11 1.25 Supplying and fixing stepped type electronic fan regulator on Each 2.00 358.00 716.00
the existing modular plate/ switch box including connections but
excluding modular plate etc.as required.
12 3.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm Set 0.00 13721.00 -
thick including accessories, and providing masonary enclosure
with cover plate having locking arrangement and watering pipe
2.7 metre long etc. with charcoal/ coke and salt as required.
13 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in mrt 5.00 144.00 720.00
recess for loop earthing etc. as required.
Total Rs 49,311.00
योजना एवं विकास विभाग
स्थानीय क्षेत्र अभियंत्रण संगठन के अंतर्गत
योजना के स्वीकृति हेतु चेकलिस्ट
1 योजना /शीर्ष /कार्यक्रम का नाम #REF!
प्राप्त आवंटन की विवरणी:
2 वित्तीय वर्ष : 2023-24
प्रसंग एवं तिथि:
3 कार्य का नाम #REF!
4 प्राक्कलित राशि #REF!
कार्य की लम्बाई /आकर /मात्रा /संख्या(जो
5
लागू हो) ,d vn~n
6 योजना संख्या 1
लोकसभा क्षेत्र का नाम मधेपुरा
7
विधानसभा क्षेत्र का नाम आलमनगर
(i) प्रखंड /पंचायत का नाम pkSlk
8 (ii) योजना से लाभान्वित होने वाले गाँव /
टोला का नाम एवं जनसंख्या pkSlk
चयन समिति की प्राथमिकता सूची की
छायाप्रति /अनुशंसा पत्र की छाया प्रति
9
/अन्य हेतु चयनित योजना की प्रासंगिक
संलग्न है
पत्र की छायाप्रति
कार्य से संबंधित योजना के मार्गदर्शिका
10 के अनुरूप योजनाओं का चयन किया गया है या हाँ
नही यदि हाँ तो किस क्रमांक की योजना है
क्या इस कार्य हेतु विवाद रहित सरकारी
जमींन उपलब्ध है (हाँ या नहीं) | यदि हाँ तो
11
सम्बंधित कनीय अभियंता एवं सहायक
हाँ
यदि
अभियंतानहींका
तोप्रमाण
क्या सम्बंधित
पत्र भूस्वामियों
द्वारा बिहार सरकार के पक्ष में
12 भूमिदान पत्र (महामहिम राज्यपाल, बिहार &
के नाम से निबंधन ) प्राक्कलन के साथ
क्या
संलग्न प्रस्तावित
है या नही योजना हेतु चिन्हित
13 भूमि पर किसी प्रकार का अतिक्रमण है (हाँ नहीं
क्या
या नही) प्रस्तावित योजना वन क्षेत्र में
पड़ता है(हाँ या नही) यदि हाँ, तो क्या वन
14
विभाग से अनापत्ति प्रमाण पत्र संलग्न
नहीं
क्या प्रस्तावित योजना वन क्षेत्र में है
या
पड़ता नही
है(हाँ या नही) यदि हाँ, तो क्या वन
15
विभागप्रस्तावित
से अनापत्ति प्रमाण पत्र संलग्न
नहीं
क्या योजना वन क्षेत्र में है
या
पड़ता नही
है(हाँ या नही) यदि हाँ, तो क्या वन
16
विभाग से अनापत्ति प्रमाण पत्र संलग्न है
नहीं
प्रस्तावित योजना में विगत पांच वर्षो
या नही
में किसी प्रकार का कार्य हुआ है(हाँ या
नही), यदि हाँ तो विवरण दे तथा यह अंकित
17 करें कि प्रस्तावित योजना के प्राक्कलन नहीं
में पूर्व योजना से सम्बंधित प्रयुक्त
किया जा सकने वाले सामग्री के समुचित
इस्तेमाल का प्रावधान
क्या प्राक्कलन किया गया
में इंडेक्स है यारुट
प्लान, नही
चार्ट, लीड चार्ट संरचना का प्लान
18
एलिवेशन, सेक्शन में विस्तृत Steel
हाँ
Reinforcement इत्यादि संलग्न है या नही
भवन निर्माण के मामले में सम्बंधित
भूकम्प जोन के लिए संरचना भूकंप निरोधी है
19
या नही यदि हाँ तो निरूपण अभियंता का
हाँ
प्लान एवं संरचना
गली निर्माण परनाली
के साथ हस्ताक्षर हैसमुचित
एवं उसकी या नही
20 स्थान पर जल निकासी का प्रावधान किया गया vko';d ugha
है या नही, यदि नही तो क्यों?
क्या प्राक्कलन विस्तृत सर्वेक्षण कर
तैयार किया गया है यदि हाँ तो कनीय
21 22.05.2023
अभियंता एवं सहायक अभियंता का स्थल
सर्वेक्षण की तिथि
क्या यह सुनिश्चित कर लिया गया है कि
योजना को पूर्णरूपेण पूरा करने के लिए सभी
22 आवश्यक मदों का समावेश प्राक्कलन में कर हाँ
लिया गया है एवं उसकी विशिष्टियां समुचित
रूप से निर्धारित कर ली गयी हैं
23 विस्तृत प्राक्कलन तैयार करने की तिथि 24.05.2023
प्राक्कलन में विस्तृत दर विश्लेषण सभी
24 अवयवों के मद संख्या के साथ संलगन है या हाँ
नही
प्राक्कलन सम्बंधित विभाग का अद्यतन
अनुसूचित दर एवं संहिता (कोड) के प्रावधान
25 BCD 01.01.2022
के अनुरूप है या नही | यदि हाँ तो किस विभाग
का है एवं
योजना मेंलागु होने की
प्रयुक्त की तिथि
जाने वाली सामग्री
की धुलाई अनुमोदित क्वैर्री/ सामग्री
स्थल से नुनतम दूरी से दी गयी है या नही,
26
साथ ही रेलवे व सड़क मार्ग में से जिसकी दर
हाँ
कम हो के तुलनात्मक विवरणी संलग्न है या
प्राक्कलन पर तकनीकी अनुमोदन/ स्वीकृति
नही
की विवरणी
पदाधिकारी का नाम: Jh johUnz dqekj flag
पदनाम: कार्यपालक अभियंता
27
राशि: #REF!
तिथि:
प्राक्कलन पर प्रशासनिक स्वीकृति करने
28 वाले
पदाधिकारी का नाम:
पदनाम:
राशि:
तिथि:
¼gLrk{kj½ ¼gLrk{kj½ ¼gLrk{kj½
Jh /kesZUnz dqekj Jh foosd dqekj Jh johUnz dqekj flag
duh; vfHk;ark lgk;d vfHk;ark dk;Zikyd vfHk;ark
LFkk0 {ks0 vfHk0 la0 LFkk0 {ks0 vfHk0 la0 LFkk0 {ks0 vfHk0 la0
inLFkkiu LFky%&e/ksiqjk inLFkkiu LFky%& e/ksiqjk e/ksiqjk
¼gLrk{kj½ ¼gLrk{kj½
uke%& uke%&
voj ;kstuk inkf/kdkjh] ftyk ;kstuk inkf/kdkjh]
ftyk e/ksiqjk ftyk e/ksiqjk