Ground Floor Plan Second Floor Plan Third Floor Plan Fourth Floor Plan
Ground Floor Plan Second Floor Plan Third Floor Plan Fourth Floor Plan
A A A A
3.48
3.48
3.48
3.48
LAV LAV LAV LAV LAV LAV LAV LAV
CO COFD FD
CO
CO CO COFD FD
CO
CO CO COFD FD
CO
CO CO COFD FD
CO
CO
WC WC WC WC WC WC WC WC
100mmØ MOLDEX PVC 100mmØ MOLDEX PVC 100mmØ MOLDEX PVC 100mmØ MOLDEX PVC
100mmØ MOLDEX PVC 50mmØ MOLDEX PVC 100mmØ MOLDEX PVC 50mmØ MOLDEX PVC 100mmØ MOLDEX PVC 50mmØ MOLDEX PVC 100mmØ MOLDEX PVC 50mmØ MOLDEX PVC
B SOLID WASTE PIPE WATER WASTE PIPE
SOLID WASTE PIPE
B SOLID WASTE PIPE WATER WASTE PIPE
SOLID WASTE PIPE
B SOLID WASTE PIPE WATER WASTE PIPE
SOLID WASTE PIPE
B SOLID WASTE PIPE WATER WASTE PIPE
SOLID WASTE PIPE
100mmØ MOLDEX PVC 100mmØ MOLDEX PVC 100mmØ MOLDEX PVC 100mmØ MOLDEX PVC
100mmØ MOLDEX PVC 50mmØ MOLDEX PVC 100mmØ MOLDEX PVC 50mmØ MOLDEX PVC 100mmØ MOLDEX PVC 50mmØ MOLDEX PVC 100mmØ MOLDEX PVC 50mmØ MOLDEX PVC
SOLID WASTE PIPE SOLID WASTE PIPE SOLID WASTE PIPE SOLID WASTE PIPE
SOLID WASTE PIPE WATER WASTE PIPE SOLID WASTE PIPE WATER WASTE PIPE SOLID WASTE PIPE WATER WASTE PIPE SOLID WASTE PIPE WATER WASTE PIPE
3.49
3.49
3.49
3.49
LAV LAV LAV LAV LAV LAV LAV LAV
12.00
12.00
12.00
12.00
FD FD FD FD FD FD FD FD
WC WC WC WC WC WC WC WC
C C C C
3.48
3.48
3.48
3.48
SEPTIC TANK SEPTIC TANK
LAV LAV LAV LAV LAV LAV LAV LAV
FD FD FD FD FD FD FD FD
WC WC WC WC WC WC WC WC
CO CO CO CO
CO CO CO CO
D D D D
1.55
1.55
1.55
1.55
FD FD
E E E E
TO MAIN SEWER TO MAIN SEWER
3 4
3.10
GENERAL NOTES:
1. ALL SANITARY WORKS INCLUDE HEREIN SHALL BE EXECUTED ACCORDING TO THE PROVISIONS OF
THE PLUMBING CODE OF THE PHILIPPINES, THE NATIONAL BUILDING CODE OF THE PHILIPPINES,
AND ITS IMPLEMENTING RULES AND REGULATIONS.
SD SD SD 2. COORDINATE THE DRAWING WITH OTHER RELATED DRAWINGS AND SPECIFICATIONS. THE
ARCHITECT AND OR THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY
WATER WATER FOUND THEREIN HIS/HER DECISION SHALL BE FINAL.
TANK TANK
3. ALL PIPES SHALL BE INSTALLED AS INDICATED. ANY RELOCATION REQUIRED FOR PROPER
EXECUTION OF OTHER TRADES SHALL BE WITH PRIOR APPROVAL WITH THE ARCHITECT AND OR
75mmØ MOLDEX PVC ENGINEER.
STORM WATER PIPE
4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION.
SD
SD 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED FLOOR AND WALL OPENINGS.
B SD 6. ALL SLOPE FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 2% MINIMUM, UNLESS OTHERWISE NOTED.
7. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S
INSTRUCTIONS.
3.49
SOLID WASTE PIPE 11. REFER TO TECHNICAL SPECIFICATION FOR DETAILED MATERIAL AND EQUIPMENT SPECIFICATIONS.
50mmØ MOLDEX PVC
WATER WASTE PIPE 12. UPON COMPLETION OF THE CONSTRUCTION OF THE SANITARY SEWER, DRAINAGE SYSTEM AND WATER SUPPLY SYSTEM,
3.48
THE CONTRACTOR SHALL REMOVE ALL SURPLUS CONSTRUCTION MATERIALS AND DEBRIS RESULTING FROM THE WORK.
KS CO
SPECIFICATION:
D UP 1. COLD WATER LINES - VESBO OR BENDEN PIPES & FITTINGS.
1.55
PRC. REG. No. : 0162392 DESIGNED BY : SEC 3 RA 9266 PROPOSED PROJECT TITLE APPROVED BY REVISION/S SHEET No.