Form 73 - Thermal

The document outlines the recommended scope of accreditation for Young Engg. & Calibration Services Pvt. Ltd. for calibration laboratories, detailing various thermal measurement instruments and their calibration capabilities. It includes specific calibration methods, measurement ranges, and observed uncertainties for each instrument. The assessment was conducted over two days, with signatures from the CAB representative and assessors confirming the recommendations.

Uploaded by

Anirban Das
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
19 views6 pages

Form 73 - Thermal

The document outlines the recommended scope of accreditation for Young Engg. & Calibration Services Pvt. Ltd. for calibration laboratories, detailing various thermal measurement instruments and their calibration capabilities. It includes specific calibration methods, measurement ranges, and observed uncertainties for each instrument. The assessment was conducted over two days, with signatures from the CAB representative and assessors confirming the recommendations.

Uploaded by

Anirban Das
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Form 73

RECOMMENDED SCOPE OF ACCREDITATION


(For Calibration Laboratories)
Name of the Laboratory: Date(s) of Visit: 22.02.2025 to 23.02.2025
Young Engg. & Calibration Services Pvt. Ltd., Howrah

Discipline: Thermal Facility: Permanent Location: KAMARDANGA ROAD,


(Temperature) ICHAPUR, HOWRAH, WEST BENGAL, INDIA
SI *Measurand or Calibration or Measureme Calibration and Measurement Capability **
Reference Material/ Measurement nt range
Type of instrument Method or and Claimed Observed Recomm Assessment
or material to be
procedure additional by CAB by ended by Technique
calibrated or
measured/ Quantity
parameters Assessor Assessor used by
Measured / where Assessor(s)
(Calibration Witness /
Instrument applicable
Document review
(Range and /Interviewing / File
Frequency) Review (Record
Review

5 Deep Freezer, Using RTD and Precision (-) 80 °C to 100 2.63 °C 1.2 °C 1.2°C Test/
Refrigerator, Incubator Thermometer (Minimum 9 ºC Calibration
(Non-medical purpose), sensor) by Multi Position Witness
Autoclave (non-medical Method
purpose), Air Oven,
Furnace, Temperature
Bath, Thermal
Chamber
6 Deep Freezer, Using RTD and Precision (-)196 ºC to 1.25 °C 1.2 °C 1.2°C Test/
Refrigerator, Thermometer (Minimum 9 (-)80 ºC Calibration
Temperature Bath, sensor) by Multi Position Witness
Thermal Chamber, Method
Thermal / Cryogenic
Tank
7 Dry Block Calibrators / Using Two R Type 600°C to 1.1 °C 1.002 °C 1.1 °C Test/ Calibration
Chamber Thermocouple with 1200°C Witness
Precision Thermometer
by Comparison Method
as per EURAMET CG No.
13
8 Dry Block Calibrators / Using Two R Type 1200°C to 1.2°C 1.002°C 1.2 °C Test/ Calibration
Chamber Thermocouple with 1500°C Witness
Precision Thermometer
by Comparison Method
as per EURAMET CG No.
13
9 Infrared Thermometer / Using Non-Contact 50 ºC to 300 3.2 °C Not 3.2 °C Adequate through
Pyrometer Thermometer & Black ºC Witnessed File Review
Body Source (Emissivity: Recommended
0.95) by Comparison the existing scope
Method
10 Infrared Thermometer / Using Non-Contact 300 ºC to 500 3.5 °C 3.5 °C 3.5 °C Test/ Calibration
Pyrometer Thermometer & Black ºC Witness
Body Source (Emissivity:
0.95) by Comparison
Method
11 Infrared Thermometer / Using Non-Contact 500 ºC to 1200 5.4 °C 4.15 °C 5.4 °C Test/ Calibration
Pyrometer Thermometer & Black ºC Witness
Body Source (Emissivity:
0.99) by Comparison
Method
12 Infrared Thermometer / Using Non-Contact (-)10 ºC to 120 0.45 °C 2.06 °C 2.06 °C Test/ Calibration
Pyrometer Thermometer & Black ºC Witness
Body Source (Emissivity:
0.95) by Comparison
Method
13 Liquid Baths/ Dry Using Two SSPRT (-)80 ºC to 50 0.15 °C 0.076 °C 0.15 °C Test/ Calibration
Block Calibrators / with Precision ºC Witness
Chamber/ Ovens Thermometer by
Comparison Method as
per EURAMET CG No. 13
14 Liquid Baths/ Dry Using Two SSPRT 250 ºC to 600 0.25 °C 0.077 °C 0.25 °C Test/ Calibration
Block Calibrators / with Precision ºC Witness
Chamber/ Ovens Thermometer by
Comparison Method as
per EURAMET CG No. 13
15 Liquid Baths/ Dry Using Two SSPRT 50 ºC to 250 ºC 0.15 °C 0.08 °C 0.15 °C Test/ Calibration
Block Calibrators / with Precision Witness
Chamber/ Ovens Thermometer by
Comparison Method as
per EURAMET CG No. 13
16 Liquid in Glass Using SPRT with 150 ºC to 250 0.09 °C 0.09 °C 0.09 °C Test/ Calibration
Thermometer Precision Thermometer & ºC Witness
Liquid Bath by
Comparison Method
17 Liquid in Glass Using SPRT with (-)80 ºC to 50 0.05 °C 0.06 °C 0.06 °C Test/ Calibration
Thermometer Precision Thermometer & ºC Witness
Liquid Bath by
Comparison Method
18 Liquid in Glass Using SPRT with 50 ºC to 150 ºC 0.07 °C 0.046 °C 0.07 °C Test/ Calibration
Thermometer Precision Thermometer & Witness
Liquid Bath by
Comparison Method
19 Liquid in Glass Using SPRT with 250 ºC to 500 0.25 °C 0.37 °C 0.37 °C Test/ Calibration
Thermometer Precision Thermometer & ºC Witness
Liquid Bath by
Comparison Method
20 RTD/ Thermocouple Using SPRT with 250 ºC to 600 0.16 °C 0.3 °C 0.3 °C Test/ Calibration
With or Without Precision Thermometer & ºC Witness
Temperature Indicator / Dry Block Calibrator by
Controller / Recorder / Comparison Method
Temperature Gauge
/Temperature
Controller Switch with
Indicator /Digital
Thermometer With
Sensor
21 RTD/ Thermocouple Using SPRT with (-)80 °C to 50 0.04 °C 0.04 °C 0.04 °C Test/ Calibration
With or Without Precision Thermometer & °C Witness
Temperature Indicator / Liquid Bath by
Controller / Recorder / Comparison Method
Temperature Gauge
/ Temperature
Controller Switch with
Indicator /Digital
Thermometer With
Sensor
22 RTD/ Thermocouple Using SPRT with 150 °C to 250 0.07 °C 0.07 °C 0.07 °C Test/ Calibration
With or Without Precision Thermometer & °C Witness
Temperature Indicator / Liquid Bath by
Controller / Recorder / Comparison Method
Temperature Gauge
/ Temperature
Controller Switch with
Indicator /Digital
Thermometer With
Sensor
23 RTD/ Thermocouple Using SPRT with (-)196 °C 0.1 °C 0.1 °C 0.1 °C Test/ Calibration
With or Without Precision Thermometer & Witness
Temperature Indicator / Liquid Bath by
Controller / Recorder / Comparison Method
Temperature Gauge
/ Temperature
Controller Switch with
Indicator /Digital
Thermometer With
Sensor
24 RTD/ Thermocouple Using SPRT with 50 °C to 150 0.05 °C 0.032 °C 0.05 °C Test/ Calibration
With or Without Precision Thermometer & °C Witness
Temperature Indicator / Liquid Bath by
Controller / Recorder / Comparison Method
Temperature Gauge
/ Temperature
Controller Switch with
Indicator /Digital
Thermometer With
Sensor
25 Temperature Indicator/ Using SPRT with 100 °C to 300 0.07 °C 0.07 °C 0.07 °C Test/ Calibration
Controller / Precision °C Witness
Recorder with sensor Thermometer by
of Block Furnace/ Comparison Method
Bath/ Oven / Thermal
Chamber (Single
Position)
26 Temperature Indicator/ Using SPRT with 300 ºC to 600 0.07 °C 0.08 °C 0.08 °C Test/ Calibration
Controller / Recorder Precision Thermometer ºC Witness
with sensor of Block by Comparison Method
Furnace/ Bath /Oven /
Thermal Chamber
(Single Position)
27 Temperature Indicator/ Using SPRT with (-)196 ºC to 0.12 °C 0.076 °C 0.12 °C Test/ Calibration
Controller / Recorder Precision Thermometer (-)80 ºC Witness
with sensor of Deep by Comparison Method
freezer/ Refrigerator/
Bath / Thermal
Chamber (Single
Position)
28 Temperature Indicator/ Using SPRT with (-)80 ºC to 100 0.08 °C 0.08 °C 0.08 °C Test/ Calibration
Controller / Recorder Precision Thermometer ºC Witness
with sensor of Deep by Comparison Method
freezer/ Refrigerator/
Recorder/ Block
Furnace/ Bath /
Thermal Chamber
(Single Position)
29 Temperature Indicator/ Using R-Type 600 ºC to 1200 1.1 °C 1.12 °C 1.12 °C Test/ Calibration
Controller/ Recorder Thermocouple with ºC Witness
with sensor of Furnace/ Precision Thermometer
Bath/ Thermal by Comparison Method
Chamber (Single
Position)
30 Temperature Indicator/ Using R-Type 1200 ºC to 1.2 °C 1.12 °C 1.2 °C Test/ Calibration
Controller/ Recorder Thermocouple with 1500 ºC Witness
with sensor of Block Precision Thermometer
Furnace/ Bath/ Thermal by Comparison Method
Chamber (Single
Position)
31 Thermal Chamber, Using RTD with 100 ºC to 350 3.05 °C 3.05 °C 3.05 °C Test/ Calibration
Incubator (Non-medical Precision Thermometer ºC Witness
purpose), Autoclave (Minimum 9 sensor) by
(Non-medical purpose), Multi Position Method
Air Oven, Furnace,
Temperature Bath,
Temperature Calibrator
32 Thermal Chamber, Using N type 350 ºC to 1200 6.9 °C 6.9 °C 6.9 °C Test/ Calibration
Furnace, Temperature Thermocouple with ºC Witness
Calibrator / Precision Thermometer
Temperature Bath (Minimum 9 sensors) by
Multi Position Method
33 Thermal Imager Using Non-Contact (-)10 ºC to 120 0.45 °C 2.06 °C 2.06 °C Test/ Calibration
(Temperature only) Thermometer & IR ºC Witness
Calibrator (Emissivity:
0.95) as per ASTM E2847
by comparison method
34 Thermocouple With or Using R type 1200 °C to 2.0 °C 2.2 °C 2.2 °C Test/ Calibration
Without Temperature Thermocouple with 1500 °C Witness
Indicator / Controller / Precision Thermometer &
Recorder / Dry Block Calibrator by
Temperature Gauge / Comparison Method
Temperature Controller
Switch with Indicator
/Digital Thermometer
With Sensor
35 Thermocouple With or Using R type 600 °C to 1200 1.4 °C 0.97 °C 1.4 °C Test/ Calibration
Without Temperature Thermocouple °C Witness
Indicator / Controller / with Precision
Recorder / Thermometer &
Temperature Gauge / Dry Block Calibrator by
Temperature Controller Comparison Method
Switch with Indicator
/Digital Thermometer
With Sensor
*For Electro technical discipline, scope shall be recommended parameters wise, for Fluid Flow discipline it shall be
range wise where as for other disciplines scope shall be recommended DUC wise.
** CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, using a
coverage factor of k = 2. NABL 143 shall be referred for the recommendation of CMC.

(Mr. Anirban Das) (Mr. Alok Sain) (Mr. Himadri Roy)


Signature, Date & Name of CAB Signature, Date & Name of Signature, Date & Name of
Representative Assessor(s) Lead Assessor
Form 73
RECOMMENDED SCOPE OF ACCREDITATION
(For Calibration Laboratories)

Name of the Laboratory: Date(s) of Visit: 22.02.2025 to 23.02.2025


Young Engg. & Calibration Services Pvt. Ltd., Howrah

Discipline: Thermal Facility: Site Location: KAMARDANGA ROAD,


(Temperature) ICHAPUR, HOWRAH, WEST BENGAL, INDIA
SI *Measurand or Calibration or Measureme Calibration and Measurement Capability **
Reference Material/ Measurement nt range
Type of instrument Method or and
or material to be Claimed Observed Recomm Assessment
procedure additional by CAB by ended by Technique
calibrated or
measured/ Quantity
parameters Assessor Assessor used by
where Assessor(s)
Measured / (Calibration Witness /
Instrument applicable
Document review
(Range and /Interviewing / File
Frequency) Review (Record
Review

5 Deep Freezer, Using RTD and Precision (-) 80 °C to 100 2.63 °C 1.2 °C 1.2°C Test/
Refrigerator, Incubator Thermometer (Minimum 9 ºC Calibration
(Non-medical purpose), sensor) by Multi Position Witness
Autoclave (non-medical Method
purpose), Air Oven,
Furnace, Temperature
Bath, Thermal
Chamber
6 Deep Freezer, Using RTD and Precision (-)196 ºC to 1.25 °C 1.2 °C 1.2°C Test/
Refrigerator, Thermometer (Minimum 9 (-)80 ºC Calibration
Temperature Bath, sensor) by Multi Position Witness
Thermal Chamber, Method
Thermal / Cryogenic
Tank
7 Dry Block Calibrators / Using Two R Type 600°C to 1.1 °C 1.002 °C 1.1 °C Test/ Calibration
Chamber Thermocouple 1200°C Witness
with Precision
Thermometer by
Comparison Method as
per EURAMET CG No. 13
8 Dry Block Calibrators / Using Two R Type 1200°C to 1.2°C 1.002°C 1.2 °C Test/ Calibration
Chamber Thermocouple 1500°C Witness
with Precision
Thermometer by
Comparison Method as
per EURAMET CG No. 13
9 Infrared Thermometer / Using Non-Contact 50 ºC to 300 3.2 °C Not 3.2 °C Adequate through
Pyrometer Thermometer & Black ºC Witnessed File Review
Body Source (Emissivity: Recommended
0.95) by Comparison the existing scope
Method
10 Infrared Thermometer / Using Non-Contact 300 ºC to 500 3.5 °C 3.5 °C 3.5 °C Test/ Calibration
Pyrometer Thermometer & Black ºC Witness
Body Source (Emissivity:
0.95) by Comparison
Method
11 Infrared Thermometer / Using Non-Contact 500 ºC to 1200 5.4 °C 4.15 °C 5.4 °C Test/ Calibration
Pyrometer Thermometer & Black ºC Witness
Body Source (Emissivity:
0.99) by Comparison
Method
12 Infrared Thermometer / Using RTD with Precision (-)15 ºC to 120 0.45 °C 0.43 °C 0.45 °C Test/ Calibration
Pyrometer Thermometer & Black ºC Witness
Body Source (Emissivity:
0.9 to 1.0) by Comparison
Method
13 Liquid Baths/ Dry Using Two SSPRT (-)80 ºC to 50 0.15 °C 0.076 °C 0.15 °C Test/ Calibration
Block Calibrators / with Precision ºC Witness
Chamber/ Ovens Thermometer by
Comparison Method as
per EURAMET CG No. 13
14 Liquid Baths/ Dry Using Two SSPRT 250 ºC to 600 0.25 °C 0.077 °C 0.25 °C Test/ Calibration
Block Calibrators / with Precision ºC Witness
Chamber/ Ovens Thermometer by
Comparison Method as
per EURAMET CG No. 13
15 Liquid Baths/ Dry Using Two SSPRT 50 ºC to 250 ºC 0.15 °C 0.08 °C 0.15 °C Test/ Calibration
Block Calibrators / with Precision Witness
Chamber/ Ovens Thermometer by
Comparison Method as
per EURAMET CG No. 13
16 Liquid in Glass Using SPRT with 150 ºC to 250 0.09 °C 0.09 °C 0.09 °C Test/ Calibration
Thermometer Precision Thermometer & ºC Witness
Liquid Bath by
Comparison Method
18 Liquid in Glass Using SPRT with 50 ºC to 150 ºC 0.07 °C 0.046 °C 0.07 °C Test/ Calibration
Thermometer Precision Thermometer & Witness
Liquid Bath by
Comparison Method
20 RTD/ Thermocouple Using SPRT with 250 ºC to 600 0.16 °C 0.3 °C 0.3 °C Test/ Calibration
With or Without Precision Thermometer & ºC Witness
Temperature Indicator / Dry Block Calibrator by
Controller / Recorder / Comparison Method
Temperature Gauge
/Temperature
Controller Switch with
Indicator /Digital
Thermometer With
Sensor
21 RTD/ Thermocouple Using SPRT with (-)80 °C to 50 0.04 °C 0.04 °C 0.04 °C Test/ Calibration
With or Without Precision Thermometer & °C Witness
Temperature Indicator / Liquid Bath by
Controller / Recorder / Comparison Method
Temperature Gauge
/ Temperature
Controller Switch with
Indicator /Digital
Thermometer With
Sensor
22 RTD/ Thermocouple Using SPRT with 150 °C to 250 0.07 °C 0.07 °C 0.07 °C Test/ Calibration
With or Without Precision Thermometer & °C Witness
Temperature Indicator / Liquid Bath by
Controller / Recorder / Comparison Method
Temperature Gauge
/ Temperature
Controller Switch with
Indicator /Digital
Thermometer With
Sensor
23 RTD/ Thermocouple Using SPRT with (-)196 °C 0.1 °C 0.1 °C 0.1 °C Test/ Calibration
With or Without Precision Thermometer & Witness
Temperature Indicator / Liquid Bath by
Controller / Recorder / Comparison Method
Temperature Gauge
/ Temperature
Controller Switch with
Indicator /Digital
Thermometer With
Sensor
24 RTD/ Thermocouple Using SPRT with 50 °C to 150 0.05 °C 0.032 °C 0.05 °C Test/ Calibration
With or Without Precision Thermometer & °C Witness
Temperature Indicator / Liquid Bath by
Controller / Recorder / Comparison Method
Temperature Gauge
/ Temperature
Controller Switch with
Indicator /Digital
Thermometer With
Sensor
25 Temperature Indicator/ Using SPRT with 100 °C to 300 0.07 °C 0.07 °C 0.07 °C Test/ Calibration
Controller / Precision °C Witness
Recorder with sensor Thermometer by
of Block Furnace/ Comparison Method
Bath/ Oven / Thermal
Chamber (Single
Position)
26 Temperature Indicator/ Using SPRT with 300 ºC to 600 0.07 °C 0.08 °C 0.08 °C Test/ Calibration
Controller / Recorder Precision Thermometer ºC Witness
with sensor of Block by Comparison Method
Furnace/ Bath /Oven /
Thermal Chamber
(Single Position)
27 Temperature Indicator/ Using SPRT with (-)196 ºC to 0.12 °C 0.076 °C 0.12 °C Test/ Calibration
Controller / Recorder Precision Thermometer (-)80 ºC Witness
with sensor of Deep by Comparison Method
freezer/ Refrigerator/
Bath / Thermal
Chamber (Single
Position)
28 Temperature Indicator/ Using SPRT with (-)80 ºC to 100 0.08 °C 0.08 °C 0.08 °C Test/ Calibration
Controller / Recorder Precision Thermometer ºC Witness
with sensor of Deep by Comparison Method
freezer/ Refrigerator/
Recorder/ Block
Furnace/ Bath /
Thermal Chamber
(Single Position)
29 Temperature Indicator/ Using R-Type 600 ºC to 1200 1.1 °C 1.12 °C 1.12 °C Test/ Calibration
Controller/ Recorder Thermocouple with ºC Witness
with sensor of Furnace/ Precision Thermometer
Bath/ Thermal by Comparison Method
Chamber (Single
Position)
30 Temperature Indicator/ Using R-Type 1200 ºC to 1.2 °C 1.12 °C 1.2 °C Test/ Calibration
Controller/ Recorder Thermocouple with 1500 ºC Witness
with sensor of Block Precision Thermometer
Furnace/ Bath/ Thermal by Comparison Method
Chamber (Single
Position)
31 Thermal Chamber, Using RTD with 100 ºC to 350 3.05 °C 3.05 °C 3.05 °C Test/ Calibration
Incubator (Non-medical Precision Thermometer ºC Witness
purpose), Autoclave (Minimum 9 sensor) by
(Non-medical purpose), Multi Position Method
Air Oven, Furnace,
Temperature Bath,
Temperature Calibrator
32 Thermal Chamber, Using N type 350 ºC to 1200 6.9 °C 6.9 °C 6.9 °C Test/ Calibration
Furnace, Temperature Thermocouple with ºC Witness
Calibrator / Precision Thermometer
Temperature Bath (Minimum 9 sensors) by
Multi Position Method
33 Thermal Imager Using IR Calibrator (-)15 ºC to 120 0.45 °C 0.43 °C 0.45 °C Test/ Calibration
(Temperature only) (Emissivity: 0.9 ºC Witness
to 1.0) and RTD sensor
with Indicator as per
ASTM E2847 by
comparison method
34 Thermocouple With or Using R type 1200 °C to 2.0 °C 2.2 °C 2.2 °C Test/ Calibration
Without Temperature Thermocouple with 1500 °C Witness
Indicator / Controller / Precision Thermometer &
Recorder / Dry Block Calibrator by
Temperature Gauge / Comparison Method
Temperature Controller
Switch with Indicator
/Digital Thermometer
With Sensor
35 Thermocouple With or Using R type 600 °C to 1200 1.4 °C 0.97 °C 1.4 °C Test/ Calibration
Without Temperature Thermocouple °C Witness
Indicator / Controller / with Precision
Recorder / Thermometer &
Temperature Gauge / Dry Block Calibrator by
Temperature Controller Comparison Method
Switch with Indicator
/Digital Thermometer
With Sensor
*For Electro technical discipline, scope shall be recommended parameters wise, for Fluid Flow discipline it shall be
range wise where as for other disciplines scope shall be recommended DUC wise.
** CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, using a
coverage factor of k = 2. NABL 143 shall be referred for the recommendation of CMC.

(Mr. Anirban Das) (Mr. Alok Sain) (Mr. Himadri Roy)


Signature, Date & Name of CAB Signature, Date & Name of Signature, Date & Name of
Representative Assessor(s) Lead Assessor

You might also like