FACT SHEET
BLOW-IN OR SPRAY-APPLIED Cellulose
Insulation
ATTIC COVERAGE CHART – LOOSE-FILL AND STABILIZED APPLICATIONS
Tabla de Cobertura de Ático - Aplicaciónes de Relleno Suelto y Aplicaciónes Estabilizadas
25lbs (11.3kg) SANCTUARY®
Minimum Thickness (inches) Net Coverage (no adjustment for framing) Net Coverage (adjusted for 2" x 6" framing on 16" centers)
Espesor minimo (en pulgadas) Cobertura neta (sin compesación para la estructura) Cobertura neta (con compensación para una estructura de 2" x 6" en centros de 16")
R-Value at 75° F
Mean Temp.
STABILIZED LOOSE-FILL
Valor de resistencia
termica (valor R) Initial Installed Initial Installed Settled Maximum Sq. Ft. per Bag Minimum Bags per 1,000 Sq. Ft. Minimum Weight per Sq. Ft. Maximum Sq. Ft. per Bag Minimum Bags per 1,000 Sq. Ft.
at 75 F de Thickness Thickness Thickness
temperature media Espesor inicial instalado Espesor inicial instalado Espesor asentado Pies cuadrados máximos por bolsa Cantidad minima de bolsas por 1,000 pies cuadrados Peso minimo por pie cuadrado Pies cuadrados máximos por bolsa Cantidad minima de bolsas por 1,000 pies cuadrados
13 3.8 3.9 3.6 65.8 15.2 0.38 72.6 13.8
19 5.5 5.7 5.3 44.2 22.6 0.57 48.8 20.5
22 6.4 6.6 6.1 38.0 26.3 0.66 41.2 24.2
30 8.7 8.9 8.3 25.9 38.6 0.97 27.4 36.5
38 10.9 11.2 10.4 19.0 52.6 1.32 19.9 50.1
44 12.6 12.9 12.0 15.7 63.5 1.59 16.5 60.8
49 13.9 14.3 13.3 14.1 70.8 1.80 14.6 68.5
60 16.9 17.3 16.1 11.6 86.0 2.20 12.0 83.5
LOOSE-FILL APPLICATIONS STABILIZED APPLICATIONS
THE ABOVE COVERAGE CHART IS BASED ON A NOMINAL BAG WEIGHT OF 25 LBS USING A VOLUMATIC THE ABOVE COVERAGE CHART IS BASED ON A NOMINAL BAG WEIGHT OF 25.0 LBS USING A VOLUMATIC III, 3RD GEAR AND 8"
III, 3RD GEAR AND 8" GATE. THE CHART IS BASED ON SETTLED THICKNESS AND IS FOR ESTIMATING GATE. THE CHART IS BASED ON SETTLED THICKNESS AND IS FOR ESTIMATING PURPOSES ONLY. DO NOT EXCEED MAXIMUM
PURPOSES ONLY. DO NOT EXCEED MAXIMUM SQUARE FEET COVERAGE PER BAG. THE APPLICATOR SQUARE FEET COVERAGE PER BAG. THE APPLICATOR MUST INSTALL BOTH THE MINIMUM NUMBER OF BAGS PER 1000 SQ.
MUST INSTALL BOTH THE MINIMUM NUMBER OF BAGS PER 1000 SQ. FT. AND THE MINIMUM FT. AND THE MINIMUM INSTALLED THICKNESS TO ENSURE THE STATED R-VALUE HAS BEEN REACHED. FAILURE TO MEET
INSTALLED THICKNESS TO ENSURE THE STATED R-VALUE HAS BEEN REACHED. FAILURE TO MEET BOTH THESE REQUIREMENTS MAY PREVENT THE APPLICATION OF SPECIFIED R-VALUE. THE INSTALLED MOISTURE CONTENT
BOTH THESE REQUIREMENTS MAY PREVENT THE APPLICAITON OF SPECIFIED R-VALUE. JOB MUST BE BETWEEN 16% AND 22% IN ATTIC APPLICATIONS. JOB CONDITIONS, APPLICATION TECHNIQUES, EQUIPMENT, AND
CONDITIONS, APPLICATION TECHNIQUES, EQUIPMENT AND SETTINGS CAN INFLUENCE ACTUAL SETTINGS CAN INFLUENCE ACTUAL COVERAGE. MINIMUM NET WEIGHT IS 23.75 LBS. IN ACCORDANCE WITH ASTM C-1497.
COVERAGE. MINIMUM NET WEIGHT IS 23.75 LBS. IN ACCORDANCE WITH ASTM C-739. THE STABILIZED APPLICATION IS FOR PROFESSIONAL INSTALLERS ONLY USING SPECIALIZED EQUIPMENT.
SIDEWALL & FLOOR COVERAGE CHART – DENSE-PACK APPLICATION
Tabla de Cobertura Lateral y del Piso - Aplicaciónes de Paquete Denso
Dry Dense-Pack Sidewall & Floor Applications (3.5 pcf minimum installed density) SANCTUARY® READ THIS BEFORE YOU BUY
Framing Thermal Resistance Installed Thickness Minimum Wt Per Square foot Maximum Coverage per Bag
(Adjusted for Framing)
WHAT YOU SHOULD KNOW ABOUT R-VALUES
Estructura (R value) (Inches) lb/ft2
Resistencia térmica Espesor instalado (pulgadas) Peso mínimo por pie cuadrado
Cobertura máxima por bolsa (con compensación para la estructura)
This chart shows the R-Value of this insulation. R means
(R) lb/ft2
16 inch o.c. ft2/Bag 24 inch o.c. ft2/Bag resistance to heat flow. The highter the R-Value, the greater
16 pulgadas o.c. pie2/bolsa 24 pulgadas o.c. pie2/bolsa
the insulating power. Compare insulation R-Values before you
2x4 13 3.5 1.02 27.0 26.1 buy. There are other factors to consider. The amount of the
2x6 21 5.5 1.60 17.2 16.6 insulation you need depends on the climate you live in. Also,
2x8 28 7.5 2.19 12.6 12.1 your fuel savings from isulation will depend upon the climate,
This coverage chart is for dry applications only and is based on the Krendl KS200, with material applied dry.
the type and size of your house, the amount of insulation
already in your house, and your fuel use patterns and family
SIDEWALL COVERAGE CHART – SPRAY-APPLIED APPLICATIONS
Tabla de Cobertura Lateral - Aplicaciónes Aplicadas por Spray
size. If you buy too much insulation, it will cost you more than
what you’ll save on fuel. To get the marked R-Value, it is
essential that this insulation be installled properly.
Spray-Applied Sidwall Applications (2.75 pcf minimum installed density) SANCTUARY®
Framing Thermal Resistance Installed Thickness Minimum Wt Per Square foot Maximum Coverage per Bag
(R value) (Inches) lb/ft2 (Adjusted for Framing)
Estructura Manufactured by
Resistencia térmica Espesor instalado (pulgadas) Peso mínimo por pie cuadrado
Cobertura máxima por bolsa (con compensación para la estructura) Casa Grande, AZ 85193
(R) lb/ft2
16 inch o.c. ft2/Bag 24 inch o.c. ft2/Bag
Greenfiber® Decatur, AL 35601
16 pulgadas o.c. pie2/bolsa 24 pulgadas o.c. pie2/bolsa Tampa , FL 33605
Toll-Free 800-228-0024
2x4 13 3.5 0.79 35.0 33.8 Eastanollee , GA 30538
www.greenfiber.com
Hickory, KY 42051
2x6 21 5.5 1.24 22.3 21.6
Greenfiber® is a registered Springfield, KY 40069
This coverage chart is based on the Volumatic III, 2nd gear, 6" gate. The installed moisture content must be between 25% and 35% as measured by a trademark of Greenfiber® Webberville, Ml 48892
hand held moisture meter. Do not cover the insulation until the insulation moisture content, measured and documented after a minimum period of 24 © 2023 Greenfiber®.
hrs from the time of installation, reaches 25% or less in accordance with Greenfiber's Wallspray Manual. Install dry dense pack Sanctuary insulation Lester Prairie, MN 55354
in all exterior wall sections where added vapor impediments, such as cabinets, mirrors, tubs, and shower enclosures are located. If unsure where All rights reserved. Norfolk , NE 68701
impediments are located, dry dense pack the entire exterior wall section(s). Non-standard or unusual wall configurations (i.e., other than 2x4 and 2x6
walls) can affect thermal and sound properties and require special installation considerations. These types of designs should be analyzed and, if Greenfiber® Chambersburg, PA 17201
necessary, tested prior to plan review. Contact Greenfiber technical representative for applications or framing that is not included on these charts.
5500 77 Center Drive, Wilkes Barre, PA 18702
Suite 100 Charlotte, NC 28217 Waco, TX 76704
Salt Lake City, UT 84119
Made in USA
Debert, Nova Scotia
PM-6.3329 Rev E 01/23 Chandler, AZ 85225
UL Classified.
See complete marking on back of packaging