Low Frequency Solar Inverter
PV3600 TLV Series (8KW-12KW)
Specification
Features MODEL PV36-8048 TLV PV36-10048 TLV PV36-12048 TLV
• Smart LCD setting(Working modes, Charge Current, Charge voltage, etc.) Nominal Battery System Voltage 48VDC 48VDC 48VDC
• Built-in MPPT solar charge controller 100A/200A Rated power 8.0KW 10.0KW 12.0KW
• MPPT efficiency max 98% Surge rating 24000VA 30000VA 36000VA
• Powerful charge rate up to 80Amp Capable of starting electric motor 4HP 5HP 6HP
• DC start &Automatic Self-Diagnostic Function Waveform Pure sine wave / same as input (bypass mode)
• USB monitoring function Nominal output voltage RMS 100V/110V/120V/200V/220V/240V
INVERTER
• Supporting AGS, BTS port OUTPUT Output frequency 50Hz / 60Hz ± 0.3Hz
• Compatible to generator Inverter effciency(peak) >88%
• Built-in bms function Line mode efficiency >95%
• Multi-brand lithium battery communication can be set up via the screen Power factor 1.0
Typical transfer time 20ms(max)
Voltage 220V/230V/240V
Introduction AC INPUT Selectable voltage range 90-280 VAC (APL)
Frequency range 50Hz / 60Hz
PV3600 TLV series is a multi-function inverter ,combining functions of inverter and MPPT solar charger controller, solar charger and battery charger
to offer uninterruptible power support. The comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery Low battery voltage cutoff 40-48VDC for 48VDC mode
charging current, AC/solar charger priority, and selectable input voltage based on different applications. Low battery voltage recover 42-50VDC for 48VDC mode
BATTERY High battery voltage cutoff 60VDC for 48VDC mode
Back panel printing description Solar system connection High battery voltage recover 57VDC for 48VDC mode
Idle consumption-search mode < 60W when power saver on
Output voltage Depends on battery type
1 4 3 2 5
Solar Panel
Charger AC input breaker rating 80A 80A 80A
1. LCD Display AC CHARGER
Overcharge protection S.D. 31.4VDC for 24VDC mode (62.8VDC for 48VDC mode )
2. Status Indicator
3. Charging Indicator Maximum charge current 60A 70A 80A
4. Fault Indicator Generator BTS Continuous output power Yes Variances in charging voltage & S.D. voltage base on the battery temperature
5. Function Buttons
Input voltage waveform Sine wave (grid or generator)
Nominal input frequency 50Hz or 60Hz
BYPASS Overload protection (SMPS Load) Circuit breaker
&
AC Input LAPTOP
1 2 3 4 PROTECTION Output short circuit protection Circuit breaker
Bypass breaker rating 63A 63A 63A
LIGHTING
Max bypass current 80Amp
AC Output
Maximum PV charge current 100A/200A
AIR-CONDITIONER
DC voltage 48V
Maximim PV array power 5000W(10000W for 200A optional)
TV
SOLAR
MPPT range @ operating voltage(VDC) 64~235VDC
CHARGER
Battery Maximum PV array open circuit voltage 250VDC
FAN
Maximum effciency >98%
5 6 7 8 9 10 11 12 13 14 15
Standby power consumption <2W
Mounting Wall mount
MECHANICAL
Dimensions (W*H*D) 640.5*402.3*212.7mm
1. BAT- 6. Fan 11. AC input SPECIFICATIONS
2. BAT+ 7. USB port 12.AC outputr Package Dimensions (W*H*D) 818*577.5*415mm
3. AC input breaker 8. AGS port 13.PV2 input Operation temperature range 0°C to 40°C
4. AC output breaker 9. BTS/BMS port 14.PV1 input
5. Remote control port 10.Wifi communication port 15.Ground Storage temperature -15°C to 60°C
OTHER
Audible noise 60dB MAX
Display LED+LCD
The technical specifications of this document are subject to change without any notice
- 49 - - 50 -