The document describes a high voltage X-ray generator designed for cardiological fluoroscopy systems, capable of delivering up to 15 kW of power and operating at 40 kHz. It outlines specifications such as maximum voltage, current, and thermal safety features, along with output signals and dimensions. The generator is suitable for both radiography and fluoroscopy applications, with options for different HV receptacles.

Uploaded by

FernandoGaro
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
115 views2 pages

E40 HF Generator

The document describes a high voltage X-ray generator designed for cardiological fluoroscopy systems, capable of delivering up to 15 kW of power and operating at 40 kHz. It outlines specifications such as maximum voltage, current, and thermal safety features, along with output signals and dimensions. The generator is suitable for both radiography and fluoroscopy applications, with options for different HV receptacles.

Uploaded by

FernandoGaro
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

HIGH VOLTAGE TANK FOR X-RAY GENERATORS E-40G HFD

FOR RADIOGRAPHY AND FLUOROSCOPY


40 kHz - 125 kV - 3,5÷15 kW
This High Voltage X-Ray Generator is suited for the supplying of the X-Ray tube’s housing of a
cardiological fluoroscopy system, where high power, 15kW pulsed fluoroscopy has to be reached, at up
to 30 frames per second.

X-RAY GENERATOR ASSEMBLY Use in Radiography


(2) Maximum Power: . . . . . . . . . . . . .3,5 kW (Inverter E-9040-5)
Operating Frequency (H.V.) 40 kHz 5 kW (Inverter E-9040-15P)
Maximum Voltage to X-Ray Tube . . . . . . . . . . . . . . . . . . . . .125 kV
Use in Fluoroscopy Receptacle (-) to ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62,5 kV
(1) Maximum Power: Receptacle (+) to ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62,5 kV
Maximum Current to X-Ray Tube: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous Fluoroscopy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 360 W
in accordance with (2) and the
Pulsed Fluoroscopy Duty Cycle 25%- 50% . . . . . . . . . . . . . . . . . . . .
X-Ray Tube Specifications
3,5 kW (Inverter E-9040-5)
Ripple at Maximum Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .< 1,5 %
15 kW (Inverter E-9040-15P)
kV Rise Time to Maximum Power . . . . . . . . . . . . . . . . . . . . .< 1 ms
Maximum Voltage to X-Ray Tube . . . . . . . . . . . . . . . . . . . . .120 kV
Receptacle (-) to ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 kV
Output Signals
Receptacle (+) to ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 kV
kV+ (Analog Signal) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0÷6,25 V
Maximum Current to X-Ray Tube: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
kV- (Analog Signal) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0÷6,25 V
in accordance with (1) and the
mA+ & mA- (Analog Signal) . . . . . . . . . . . . anodic mA readings
X-Ray Tube Specifications
Ripple at Maximum Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .< 1,5 %
Dimensions and Weight
kV Rise Time to Maximum Power . . . . . . . . . . . . . . . . . . . . .< 1 ms
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (see picture)
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17,5 kg
Thermal Features
Compensation Bellow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0,2 dm3
Thermal Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57°C ACCESSORIES
400 Hz Filament Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .S15

The Generator can be delivered with Big or Small HV-Receptacles.

Doc.: 9921

Specifications subject to change without notice.