0% found this document useful (0 votes)
19 views10 pages

Directional

The document outlines the specifications and ordering instructions for the 90-SV Series of solenoid valves and related components, which are IP67 compliant and compatible with secondary batteries. It details various configurations, including actuation types, port sizes, and additional features such as manual overrides and voltage suppressors. The document also includes information on compatible series, connection types, and specific part numbers for different configurations.

Uploaded by

mugirahayusyofan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
19 views10 pages

Directional

The document outlines the specifications and ordering instructions for the 90-SV Series of solenoid valves and related components, which are IP67 compliant and compatible with secondary batteries. It details various configurations, including actuation types, port sizes, and additional features such as manual overrides and voltage suppressors. The document also includes information on compatible series, connection types, and specific part numbers for different configurations.

Uploaded by

mugirahayusyofan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

Single Valve/Sub-plate Type IP67 Compliant

90-SV Series
How to Order

90 SV 2 1 00 5 W1 U D
Series compatible with Thread type
secondary batteries Nil Rc
90 Material restriction F G
Series N NPT
2 90-SV2000 T NPTF
4 90-SV4000

Type of actuation Port size


Symbol Port size Applicable series
2 position single
Nil Without sub-plate
(A) (B)
4 2 02 1/4 90-SV2000
1 03 3/8 90-SV4000
5 1 3 04 1/2 90-SV4000
(EA) (P) (EB)

2 position double
(A)
4
(B)
2
Manual override
2 Nil Non-locking push type
5 1 3 D Push-turn locking slotted type
(EA) (P) (EB)

3 position closed center


(A) (B)

3
4 2
Light/Surge voltage suppressor
U With light/surge voltage suppressor(Non-polar type)
5 1 3
(EA) (P) (EB) R With surge voltage suppressor(Non-polar type)

3 position exhaust center


(A) (B)
4 2 M12 waterproof connector
4
Symbol Cable length (mm)
5 1 3 W1 300
(EA) (P) (EB)
W2 500
3 position pressure center W3 1000
(A) (B) W4 2000
4 2
5 W7 5000

5 1 3
(EA) (P) (EB)

4 position dual 3 port valve: N.C./N.C.


Rated voltage
(A) (B) 5 24 VDC
4 2
6 12 VDC
A SOL.a SOL.b
5 3
(EA) (EB)

1
(P) Pilot type
4 position dual 3 port valve: N.O./N.O. Nil Internal pilot
(A) (B) R External pilot
4 2
*External pilot specifications is not
B SOL.a SOL.b available for 4 position dual 3 port
5 3
(EA) (EB) valves.
1
(P)

4 position dual 3 port valve: N.C./N.O.


(A) (B)
4 2

C SOL.a
5
SOL.b
3 *Specifications and dimensions for the 90-series are the
(EA) (EB)
same as standard products.
1
(P)
*4 position dual 3 port valve is not available for the 90-SV4000.

2
EX124 Integrated Type (for Output)
Serial Transmission System

90-SV-X124 Series

Control Valves
IP65 Compliant

Directional
How to Order Manifold

Actuators
Tie-rod base

90 SS5V 2 10S Q D 05 U X124


Series compatible with
secondary batteries
Specifications

Air Grippers
90 Material restriction 1. Special SI unit:
EX124D-SDN1-X188
(PNP open collector)
Series 2. Enclosure: IP65 compliant

2 90-SV2000
4 90-SV4000

Air Filters/Pressure Air Preparation


SUP/EXH block assembly

Equipment
SI unit specifications
Symbol Protocol type
Nil Internal pilot
Q DeviceNet
R External pilot

Valve stations P, E port location


Symbol Stations Note U U side (2 to 10 stations)

Related Products Control Equipment


02 2 stations (1) D D side (2 to 10 stations)
Double wiring specifications B Both sides (2 to 16 stations)
08 8 stations
02 2 stations (2)
Specified layout
(up to 16 solenoids possible.)
16 16 stations
• Including the number of blanking plate assemblies.
Note 1) Double wiring specifications: Single, double, 3 position and 4
position solenoid valves can be used on all manifold stations.

Flow Control
Use of a single solenoid will result in an unused control signal.
If this is not desired, order with a specified layout.
Note 2) Specified layout: Indicate wiring specifications on a manifold
specification sheet.
(Note that double, 3 and 4 position valves cannot be used
where single solenoid wiring has been specified.)

SI Unit Part No.


Symbol Protocol type SI unit part no. CE-certified Equipment
DeviceNet
Vacuum

Q (Negative common)
EX124D-SDN1-X188

A, B port size (Metric) A, B port size (Inch)


Symbol A, B port P, E port Applicable series Symbol A, B port P, E port Applicable series
C4 One-touch fitting for ø4 N3 One-touch fitting for ø5/32"
One-touch One-touch
C6 One-touch fitting for ø6
fitting for ø10
90-SV2000 N7 One-touch fitting for ø1/4"
fitting for ø3/8"
90-SV2000
Detection
Switches

C8 One-touch fitting for ø8 N9 One-touch fitting for ø5/16"


M A, B ports mixed M A, B ports mixed
*In the case of mixed specifications (M), indicate separately on the manifold specification sheet.
*Port sizes of X, PE port for external pilot specifications (R) are ø4 mm or ø5/32 inch.
Auto Switches

*Specifications and dimensions for the 90-series are the same as standard products.

3
EX124 Integrated Type (for Output)
Serial Transmission System

90-SV-X166 Series
IP65 Compliant

How to Order Manifold


Tie-rod base

90 SS5V 2 10S V D 05 U X166


Series compatible with
secondary batteries
Specifications
90 Material restriction 1. Special SI unit:
EX124D-SMJ1-X182
(Negative common)
Series 2. Enclosure: IP65 compliant

2 90-SV2000
4 90-SV4000

SI unit SUP/EXH block assembly


specifications
Symbol Protocol type
Nil Internal pilot
V CC-Link
R External pilot

Valve stations P, E port location


Symbol Stations Note U U side (2 to 10 stations)
02 2 stations (1) D D side (2 to 10 stations)
Double wiring specifications B Both sides (2 to 16 stations)
08 8 stations
02 2 stations (2)
Specified layout
(up to 16 solenoids possible.)
16 16 stations
• Including the number of blanking plate assemblies.
Note 1) Double wiring specifications: Single, double, 3 position and 4
position solenoid valves can be used on all manifold stations.
Use of a single solenoid will result in an unused control signal.
If this is not desired, order with a specified layout.
Note 2) Specified layout: Indicate wiring specifications on a manifold
specification sheet.
(Note that double, 3 and 4 position valves cannot be used
where single solenoid wiring has been specified.)

SI Unit Part No.


Symbol Protocol type SI unit part no. CE-certified
CC-Link
V (Negative common)
EX124D-SMJ1-X182

A, B port size (Metric) A, B port size (Inch)


Symbol A, B port P, E port Applicable series Symbol A, B port P, E port Applicable series
C4 One-touch fitting for ø4 N3 One-touch fitting for ø5/32"
One-touch One-touch
C6 One-touch fitting for ø6
fitting for ø10
90-SV2000 N7 One-touch fitting for ø1/4"
fitting for ø3/8"
90-SV2000
C8 One-touch fitting for ø8 N9 One-touch fitting for ø5/16"
C8 One-touch fitting for ø8 N9 One-touch fitting for ø5/16" One-touch
One-touch 90-SV4000
C10 One-touch fitting for ø10 90-SV4000 N11 One-touch fitting for ø3/8" fitting for ø3/8"
fitting for ø12
C12 One-touch fitting for ø12 M A, B ports mixed
M A, B ports mixed
*In the case of mixed specifications (M), indicate separately on the manifold specification sheet.
*Port sizes of X, PE port for external pilot specifications (R) are ø4 mm or ø5/32 inch for 90-SV2000 series and ø6 mm or
ø1/4 inch for 90-SV4000 series.

*Specifications and dimensions for the 90-series are the same as standard products.

4
D-sub Connector

90-SV Series

Control Valves
Directional
How to Order Manifold

Actuators
Tie-rod base

90 SS5V 2 10FD 1 05 U
Series
2 90-SV2000
4 90-SV4000

Air Grippers
Series compatible with secondary batteries
90 Material restriction

Connector entry direction


1 Upward

Air Filters/Pressure Air Preparation


2 Lateral

Equipment
Valve stations
Symbol Stations Note
02 2 stations (1)
···

···

Double wiring specifications


11 11 stations

Related Products Control Equipment


02 2 stations (2)
Specified layout
···

···

20 20 stations (Up to 23 solenoids possible.)


Note 1) Double wiring specifications: Sin-
gle, double, 3 position and 4 pos-
ition solenoid valves can be used
at all of the manifold stations.
Use of a single solenoid will re-
sult in an unused control signal. If
this is not desired, order with a
specified layout.

Flow Control
Note 2) Specified layout: Indicate wiring
specifications on the manifold
specification sheet. (Note that
double, 3 and 4 position valves
cannot be used where single sol-
enoid wiring has been specified.)

P, E port location
U U side (2 to 10 stations)
Equipment
D D side (2 to 10 stations)
Vacuum

B Both sides (2 to 20 stations)

Pilot type
Nil Internal pilot
R External pilot
Detection
Switches

A, B port size (metric) A, B port size (inch)


Symbol A, B port P, E port Applicable series Symbol A, B port P, E port Applicable series
C4 One-touch fitting for ø4 N3 One-touch fitting for ø5/32"
One-touch One-touch
C6 One-touch fitting for ø6
fitting for ø1
90-SV2000 N7 One-touch fitting for ø1/4"
fitting for ø3/8"
90-SV2000
C8 One-touch fitting for ø8 N9 One-touch fitting for ø5/16"
C8 One-touch fitting for ø8 N9 One-touch fitting for ø5/16" One-touch
One-touch 90-SV4000
Auto Switches

C10 One-touch fitting for ø10 90-SV4000 N11 One-touch fitting for ø3/8" fitting for ø3/8"
fitting for ø12
C12 One-touch fitting for ø12 M A, B ports mixed
M A, B ports mixed
*In the case of mixed specifications (M), indicate separately on the manifold specification sheet.
*Port sizes of X, PE port for external pilot specifications (R) are ø4 mm or ø5/32 inch for 90-SV2000 series and ø6 mm or ø1/4 inch
for 90-SV4000 series.

*Specifications and dimensions for the 90-series are the same as standard products.
5
90-SV Series

How to Order Solenoid Valves

90 SV 2 1 0 0 5 F
Series compatible with Manual override
secondary batteries Nil: Non-locking push D: Push-turn locking
90 Material restriction type slotted type

Series
2 90-SV2000
4 90-SV4000

Type of actuation
1 2 position single
2 2 position double
3 3 position closed center
4 3 position exhaust center Light/Surge voltage suppressor
5 3 position pressure center U With light/surge voltage suppressor
A 4 position dual 3 port valve: N.C./N.C. R With surge voltage suppressor
B 4 position dual 3 port valve: N.O./N.O.
C 4 position dual 3 port valve: N.C./N.O.
*4 position dual 3 port valve is not available for the Rated voltage
90-SV4000.
5 24 VDC
6 12 VDC

Pilot type
Nil Internal pilot
R External pilot
*External pilot specifications
is not available for 4 position
dual 3 port valves.

*Specifications and dimensions for the 90-series are the same as standard products.

6
Plug-in Unit
Base Mounted
90-VQ1000-X121 Series
90-VQ2000-X121 Series

Control Valves
Double Check Block (Separated Type)

Directional
How to Order

Actuators
90-VQ1000 90 VQ1000 FPG C6 C6 X121
Series compatible with secondary batteries For blanking
90 Material restriction manual specification

Air Grippers
OUT side port size
C4 One-touch fitting for ø4
C6 One-touch fitting for ø6

IN side port size


C4 One-touch fitting for ø4

Air Filters/Pressure Air Preparation


C6 One-touch fitting for ø6

Equipment
*Specifications and dimensions for the 90-series are the
same as standard products.

Related Products Control Equipment


90-VQ2000 90 VQ2000 FPG 01 01 X121
Series compatible with secondary batteries For blanking
90 Material restriction manual specification

OUT side port size


01 Rc 1/8

Flow Control
IN side port size
01 Rc 1/8

*Specifications and dimensions for the 90-series are the


same as standard products.
Equipment
Vacuum
Detection
Switches Auto Switches

7
3 Port Solenoid Valve
Pilot Operated Poppet Type

90-VP300/500 Series
Rubber Seal

How to Order

90 VP 3 4 2 5DZ 02 A
Series compatible with
secondary batteries Passage symbol
90 Material restriction A N.C. (Normally closed)
B N.O. (Normally open)
Only "A" is available for external
Series VP solenoid valve pilot type.

Body size Thread type


3 14 standard Nil Rc
5 38 standard F G
N NPT
T NPTF
Type of actuation
Common use to normally closed
4 Port size
and normally open (Pilot)
Symbol Port size Rc 90-VP342 90-VP542
02 14
Body type 03 38
2 Body ported

Manual override
Valve option Nil Push type
Nil Standard (Internal pilot) B Locking type (Slotted)
R External pilot C Locking type (Manual)

Rated voltage Light/Surge voltage suppressor


5 24 VDC
Nil None
6 12 VDC Z* With light/surge voltage suppressor
*Option

Electrical entry
D DIN terminal

How to Order Pilot Valve Assembly Pilot Valve Assembly and Electrical Entry
Symbol Electrical entry

90 SF4 5 D Z 50 Surge voltage suppressor


Indicator light
DZ
Rated voltage Manual override
5 24 VDC Nil Push type
6 12 VDC B Locking type (Slotted)
C Locking type (Manual)
Series compatible with
secondary batteries
90 Material restriction Light/Surge voltage suppressor
Nil None
Z* With light/surge voltage suppressor
Electrical entry
*Option
D DIN terminal

*Specifications and dimensions for the 90-series are the same as standard products.

8
3 Port Solenoid Valve
Pilot Operated Poppet Type

90-VG342 Series

Control Valves
Directional
Rubber Seal

How to Order

Actuators
90 VG342 5DZ 04 A
Series compatible with
secondary batteries Pilot valve option
90 Material restriction Valve option Nil Standard type

Air Grippers
Nil Internal pilot Y Energy-saving type (DC only)
R External pilot E Continuous duty type

Rated voltage
Passage symbol
5 24 VDC
Nil External pilot
6 12 VDC
A N.C. (Normally closed)

Air Filters/Pressure Air Preparation


B N.O. (Normally open)

Equipment
Electrical entry
D DIN terminal Thread type
Nil Rc
F G
N NPT
Light/Surge voltage suppressor T NPTF

Related Products Control Equipment


Nil None
Z With light/surge voltage suppressor

Port size
04 12
06 34
10 1

Flow Control
*Specifications and dimensions for the 90-series are the same as standard products.

Equipment
Vacuum
Detection
Switches Auto Switches

9
3 Port Solenoid Valve
Direct Operated Poppet Type

90-VT317 Series
Rubber Seal

How to Order

90 V T 317 5 D Z 02
Series compatible with Port size
secondary batteries 02 1 4 (8A)
90 Material restriction

Body type
T Body ported
Light/Surge voltage suppressor
Electrical
entry D
Symbol
Valve option Nil —
Nil Standard type S
E Continuous duty type Z
V For vacuum Z: With light/surge voltage suppressor

Rated voltage
5 24 VDC
6 12 VDC

Electrical entry
D DIN terminal

*Specifications and dimensions for the 90-series are the same as standard products.

10
Finger Valve

90-VHK Series

Control Valves
Directional
How to Order

Actuators
Standard type 90 VHK 2 02S 06F
Series compatible with Bracket
secondary batteries Nil None
90 Material restriction L With L-bracket

Air Grippers
*Bracket and
Valve model screws are
attached.
2 2 port valve

Knob color
1(P) port size Nil
ø4 (Standard) Gray
04F

Air Filters/Pressure Air Preparation


06F ø6

Equipment
R
ø8 (Option) Red
08F
01S R18
02S R14
03S R38
2(A) port size
04F ø4
06F ø6

Related Products Control Equipment


08F ø8

*Specifications and dimensions for the 90-series are the same as standard products.

Applicable Series L Type Bracket Part No.

Flow Control
Standard Type 1(P): One-touch fitting · 2(A): One-touch fitting
Applicable tubing O.D. (mm) Bracket
1(P) 2(A) assembly no.

ø4 ø4 90-VHK-B1A

ø4
ø6 90-VHK-B1A Equipment
ø6
Vacuum

1(P): One-touch fitting 1(P): Male thread ø6


2(A): One-touch fitting 2(A): One-touch fitting ø8 90-VHK-B1A
ø8
2(A) Applicable tubing O.D. (mm) 2(A) Applicable tubing O.D. (mm)
1(P) ø4 ø6 ø8 1(P) ø4 ø6 ø8
1(P): Male thread · 2(A): One-touch fitting
Applicable tubing

ø4 — — 18
Port size R
O.D. (mm)

Connection thread R Applicable tubing O.D. (mm) Bracket


Detection
Switches

ø6 — 14 — 1(P) 2(A) assembly no.

ø8 — 38 — ø4
18 ø6 90-VHK-B1A
ø8
ø6
14 90-VHK-B1A
Auto Switches

ø8
ø6
38 90-VHK-B1A
ø8

11

You might also like