Product Data Sheet
PDS 71-381/rev.A
September 1999                                                                Model 381 pH/ORP
Insertion/Submersion Flow Through Sensor
• ADVANCED ON-LINE SENSOR DIAGNOSTICS1
  (Model 381+ only), for use with the Model
  54pH/ORP Analyzer and 3081pH/ORP Transmitter,
  predict and identify process-related sensor failures.
• MODULAR DESIGN facilitates maintenance by
  eliminating terminal and mounting brackets and
  extraneous hardware.
• DOUBLE-JUNCTION, GEL-FILLED REFERENCE
  CELL provides high temperature performance,
  extended service life, and resistance to the effects
  of pumping, dilution, and contamination.
• MOLDED POLYETHERSULFONE (PES) BODY
  provides compatibility with a variety of processes.
• OPTIONAL FLOW-POWERED OR ULTRASONIC
  CLEANING provides trouble-free service in difficult
  applications.
FEATURES AND APPLICATIONS
The Rosemount Analytical Model 381 Sensor meas-            The modular body design eliminates the need for
ures the pH or the Oxidation Reduction Potential           internal mounting brackets, terminal brackets, and
(ORP) of aqueous solutions in pipelines, open tanks, or    screws. All components are screw-type or plug-in-
ponds. The sensor is suitable for use in most industrial   place, allowing for fast simple service.
applications, including water and waste treatment          The integral preamplifier conditions the high imped-
plants.                                                    ance glass electrode signal at the sensor, providing a
The Model 381 is available with an optional stainless      transmission capability of up to 1000 ft (304.8 m). The
steel solution ground. The solution ground provides        Rosemount Analytical method of preamplification has
advanced sensor diagnostics for preventative mainte-       become the industry standard for reliable pH meas-
nance when used with the Models 54pH/ORP                   urement. In submersion applications at temperatures
Analyzer and 3081pH/ORP Transmitter. Sensor diag-          greater than 80°C, the preamplifier must be located in
nostics result in time and money savings by reducing       a remote junction box or in the instrument.
the guesswork in sensor maintenance and replace-           A double-junction, gel-filled reference cell, a stan-
ment requirements.                                         dard feature of the Model 381, improves sensor life
The sensor is housed in a molded PES body and has          when unknown reference cell contaminants, such
two O-ring seals with breach lock threads that secure      as sulfides, may exist. The gel solution maintains its
the PES cover. This provides a waterproof union for        viscosity at high temperatures, and resists the effect
long operating life and easy removal for routine main-     of pumping and dilution, resulting in an extended
tenance.
                                                                                              Continued on page 2
FEATURES AND APPLICATIONS
Continued from page 1
service life. A choice of a wood or ceramic liquid junc-                            fluid in a circular path carrying three Teflon2 balls that
tion allows the user to optimize performance by                                     clean the electrode surface, physically preventing
emphasizing reference life (wood) or chemical resist-                               accumulation of coating materials. Flow-powered
ance (ceramic).                                                                     cleaning is suitable for all hazardous area applica-
In many flow applications, crystalline or viscous coat-                             tions.
ings are present, such as calcium carbonate or petro-                               The Model 381 is available with 3K Balco or Pt 100
leum oils, which may coat the electrode surfaces and                                temperature compensation and is compatible with all
impede the sensor’s performance. The flow-powered                                   Rosemount Analytical pH/ORP Analyzers.
cleaning option may be used in these instances. A                                   1
                                                                                        Patent pending
specially designed flow chamber directs the process                                 2
                                                                                        Teflon is a registered trademark of E.I. du Pont de Nemours & Company.
SPECIFICATIONS
Materials of Construction:
      Body, Cover and Flow Cell: Polyethersulfone (PES)                             Minimum Conductivity: 75 µS/cm, nominal 100 µS/cm
      O-Rings: Viton3                                                               Temperature Compensation: Automatic, 0 to 100°C
                                                                                       (32 to 212°F)
      Measuring Electrode: Glass (and platinum or gold
       for Model 381 ORP)                                                           Maximum Pressure/Temperature Rating:
                                                                                       790 kPa (abs) at 100°C (100 psig at 212°F)
      Liquid Junction: Kynar4/wood (Code 20) or
        Kynar/ceramic (Code 21)                                                     Cable: For Code pH, pHE, ORP: 4 conductor, 22 GA
                                                                                       with common shield. Code +: 10 conductor,
      Solution Ground: 316 Stainless steel (Code + only)                               shielded cable
Sensor Process Connections:                                                         Weight/Shipping Weight: 1.0 kg/1.7 kg (2.2 lb/3.7lb)
   Submersion: 3/4 in. MNPT
                                                                                    3
                                                                                      Viton is a registered trademark of E.I. du Pont de Nemours & Co.
      Insertion: 2 in. MNPT                                                         4
                                                                                      Kynar is a trademark of Elf Atochem North America, Inc .
Flow Through Cell: 3/4 in. MNPT inlet and outlet                                    5
                                                                                      A CCU G LASS is a trademark of Rosemount Analytical.
Measuring Ranges:
   ORP; -1500 to +1500 mV
      pH; ACCUGLASS™5 0-14
                                         Percent Linearity Over pH Range
                        General Purpose and Ruggedized glass (codes -10 &-12)                                 High pH glass (code -11)
      0-2 pH                                               97%                                                            94%
     2-12 pH                                               99%                                                            97%
    12-13 pH                                               96%                                                            98%
    13-14 pH                                               92%                                                            98%
* Note: Ruggedized glass electrodes are ideal for abrasive applications, but response times are typically slower than other glass
formulas.
2 Rosemount Analytical
   MOUNTING AND DIMENSIONAL DRAWING
    MILLIMETER
       INCH
                                                   CABLE 4.5 IN.
                       CORD GRIP                         15 FT.
                 (DO NOT REMOVE)
                      9.5
                      3/8
                                                    3/4” MNPT
                                                      COVER
                   249.2
                   8-13/16
                                                      BODY
                                                      2 IN. MNPT
                                                      (FOR INSERTION
                                                      INSTALLATION)
                          48.4
                         1-28/32
                                       47.6
                                     1-7/8 DIA
                                        81.7
                                     3-7/32 DIA
              MEASURING
              ELECTRODE                             TEMPERATURE
                                                    COMPENSATOR1
        LIQUID JUNCTION
              1 ALSO SERVES AS SOLUTION GROUND FOR 381+
INSERTION AND FLOW THROUGH INSTALLATION
                                   10°
                                   MIN
                    2 IN.
                    MNPT
                                                    2 IN. MNPT
                    PIPE TEE
                    INSTALLATION                  SIDE OF TANK
                    STRAIGHT                      INSTALLATION
            FLOW    FLOW
  3/4 IN.
  MNPT
                   10°
                   MIN
                                                      2 IN. MNPT
                               WELD                 150 LBS. RAISED
                         2 IN.   GASKET             FACE FLANGE
                         MNPT                       PIPE LINE
                                                    INSTALLATION
                                   FLOW
                    PIPE TEE INSTALLATION
                    ELBOW FLOW
            FLOW
                                                                       Rosemount Analytical 3
                   SUBMERSION INSTALLATION: HANDRAIL MOUNTING ACCESSORY (P/N 1000857)
4 Rosemount Analytical
MILLIMETER
   INCH
   SUBMERSION INSTALLATION: HANDRAIL MOUNTING ACCESSORY (P/N 11275-00)
                                                                Rosemount Analytical 5
          MILLIMETER
             INCH          MODEL 381 SENSOR IN
                         FLOW THROUGH ASSEMBLY
                              MODEL 381 SENSOR WITH FLOW
                              POWERED CLEANER, MINIMUM FLOW
                              RATE REQUIRED IS 2 gpm;
                              DO NOT EXCEED 6 gpm AS THIS
                              COULD CAUSE ELECTRODE DAMAGE.
6 Rosemount Analytical
ORDERING INFORMATION
Model 381 pH/ORP Sensor is housed in a PES body suitable for insertion, submersion, or flow through
installation. The sensor is offered with an integral preamplifier, measuring electrode, double-junction gel-filled
reference cell, automatic temperature compensation for pH, and a choice of two cable lengths of either
15 ft or 50 ft (4.5 or 15.2 m).
  MODEL
   381        INSERTION, SUBMERSION, FLOW THROUGH SENSOR
  CODE        FUNCTION
   pH         pH assembly for Models 1003, 1023, 1050, 1060, and 1181pH; requires Code 30
   pE         pH or ORP assembly for Models 1054, 1054A, 1054B, 2054, and 2081; requires Code 31
    +         pH or ORP assembly for Models 54, 81, 3081, 4081 pH or ORP; requires Code 31
   OR         ORP assembly for Models 1003, 1023, 1050, 1060, and 1181ORP; requires Code 32
  CODE        INSTALLATION
   00         Insertion, 2 in. MNPT
   02         Submersion, 3/4 in. MNPT
   03         Flow Through Assembly, 3/4 in. MNPT inlet and outlet
   04         Flow Through Assembly with Flow Powered Cleaner (not available with ORP), 3/4 in. MNPT inlet and outlet
  CODE        MEASURING ELECTRODE
   10         General purpose pH, GPHT (0-14), not available with Code OR
   11         High pH Electrode, requires Code 21. For sodium concentrations greater than 1 or continuous
              measurement above 11 pH; not available with Code OR
    12        Ruggedized pH Electrode. For abrasive solutions, not available with Code OR
    13        Platinum ORP Electrode, not available with Code pH
    14        Gold ORP Electrode, not available with Code pH
    15        HF pH Electrode. For HF concentrations less than 300 ppm, not available with Code OR
  CODE        LIQUID JUNCTION
   20         Wood/Kynar Liquid Junction
   21         Ceramic/Kynar Liquid Junction
  CODE        TEMPERATURE COMPENSATION
   30         Automatic TC, 3K ohm. For Models 1003, 1023, 1050, 1060, & 1181pH
   31         Automatic TC Pt 100, 100 ohm RTD. For Models 1054, 1054A, 1054B, 2054, 2081, 54, 81, 3081, and 4081
   32         Automatic TC NOT REQUIRED. For Models 1003, 1023, 1050, 1060, & 1181 ORP
  CODE        CABLE
   40         15 ft (4.5 m) cable for integral sensor preamp (see below for preamp choices)
   41         15 ft (4.5 m) coax cable w/BNC connector for remote sensor preamp and integral analyzer preamp
              (Models 1054A-54, 1054B-54, 2054-54 only)
    42        15 ft (4.5 m) coax cable w/o BNC connector for integral analyzer preamp (Models 1054, 1181-43/44, and
              2081-05 only), not available with Codes OR and +
    43        50 ft (15.2 m) cable for integral sensor preamp (see below for preamp choices)
  CODE         INTEGRAL PREAMPLIFIER
   50          Preamp for Models 1181 pH/ORP & 1050/1060
   51          Preamp for Models 1003/1023
   52          Preamp NOT REQUIRED (uses Code 41 or 42 only)
   54          Preamp for Models 1054, 1054A, 1054B, 2054, and 2081
   55          Preamp for Models 54, 81, 3081, and 4081 (for Code+ only)
     381         pH        00        10       20     30       40       50                    EXAMPLE
NOTE: Model 2700 Analyzer can be used only with Models 381+-31/33-45-52.
                                                                                                    Rosemount Analytical 7
MODEL 381 pH, pHE, ORP ACCESSORIES
      PART #             DESCRIPTION
     1000856             Handrail mounting bracket for submersion service, for use with Models 1003 & 1023
     1000857             Handrail mounting bracket for submersion service, for use with remote junction box
     22697-00            Combination pH electrode, general purpose
     22697-01            Combination pH electrode, high pH
     22698-00            Preamplifier for use with Models 1003, 1023
     22698-02            Preamplifier for use with Models 1050, 1181
     22698-03            Preamplifier for use with Models 1054/2054 Series, 2081
     22719-02            Remote junction box
     22811-00            Flow cell (includes electrode shroud)
     22892-00            Flow powered cleaner retrofit kit (for use with Option -03 sensors)
     22996-00            Remote junction box for internal preamp
     23296-00            Remote Division 2 junction box for internal preamp for use with Models 1181pH/ORP,
                         1050/1060, 1003/1023
     23296-01            Remote Division 2 junction box for internal preamp for use with Models 1054/2054 Series, 2081
     9200160             Extension cable, sensor or remote preamp to analyzer, specify length
MODEL 381+ ACCESSORIES
   PART #                DESCRIPTION
  11275-00               Handrail mounting bracket for submersion service
  1000857                Handrail mounting bracket for submersion service, for use with remote junction box
  22892-00               Flow powered cleaner retrofit kit (for use with option -03 sensors)
  23550-00               Junction Box, with extension board 54, 81, 3081, and 4081 compatible
  23646-01               Extension cable, double shield, prepped, specify length, for option -40 and -43
  23555-00               Remote junction box with preamp for 54, 81, 3081, and 4081 compatible, for option -40 and -43
  23557-00               Preamplifier for junction box, 54, 81, 3081, and 4081 compatible
  9200273                Extension cable, 10 conductor, shielded, unprepped, specify length
                          The right people,
                          the right answers,
                          right now.
                                                               ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE
                                                                                                http://www.raihome.com
                                                                                         Credit Cards for U.S. Purchases Only.
Emerson Process Management
Rosemount Analytical Inc.
2400 Barranca Parkway
Irvine, CA 92606 USA
Tel: (949) 757-8500
Fax: (949) 474-7250
http://www.raihome.com