0% found this document useful (0 votes)
106 views50 pages

QPS Catalogue

Success designs and manufactures Low Voltage Dry-Type Transformers using Vacuum Pressure Impregnation technology, ensuring reliability and energy efficiency for various applications. The company, established in Malaysia in 1980, focuses on quality and innovation while providing customized solutions as an Original Design and Equipment Manufacturer. Their products comply with international standards and are designed to meet diverse customer needs, including specialized transformers for industrial, commercial, and marine environments.

Uploaded by

Waleed Ashraf
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
106 views50 pages

QPS Catalogue

Success designs and manufactures Low Voltage Dry-Type Transformers using Vacuum Pressure Impregnation technology, ensuring reliability and energy efficiency for various applications. The company, established in Malaysia in 1980, focuses on quality and innovation while providing customized solutions as an Original Design and Equipment Manufacturer. Their products comply with international standards and are designed to meet diverse customer needs, including specialized transformers for industrial, commercial, and marine environments.

Uploaded by

Waleed Ashraf
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 50

Electrical Apparatus

Responding to a
Changing World

“In the past several years, there has been an accelerated


rate of change to introduce energy efficiency standards
globally not only for lighting but for transformers as well.”

Success designs and manufactures Low Voltage Dry-Type Transformers


using the Vacuum Pressure Impregnation (VPI) technology which already
proven to be highly reliable over the years used in diverse commercial and
industrial environments. These transformers are used in many applications
including in commercial buildings, on board of vessels as well as in deep
mines and industrial environment as well as the most demanding and
special requirements including OPTIMIZED SPACE UTILIZATION.

Safe, Reliable & Energy Efficient


“Quality and innovation are two of the company’s
central philosophies. To this end, we use up-to-date
technology and we are constantly researching to
develop new systems and products.”

Success is a transformer and lighting manufacturing company incorporated in Malaysia since 1980 wholly-owned by Success
Transformer Corporation Berhad (STC), a public listed company in the Main Board of Bursa Malaysia. We have been the
foremost provider of lighting and power distribution technologies, enabling new and more efficient uses of energy in
industrial areas that can transform our world both visually and practically.

“With our capabilities, we Our Complete Solutions Workflow begin from conception all the way to
final installation on site. We have amassed the necessary software, and
are able to manufacture from
hardware and expertise. Success is an Original Design Manufacturer (ODM)
ground up, to match as close where we design and manufacture products for customers under their
to perfection as possible to own brands, and an Original Equipment Manufacturer (OEM) where we
your compliance, performance manufacture products for customers according to their designs. We can
create any design, in almost any situation, and we will present a visual
and output, sustainability &
rendering of the design or design area to the customer as part of our pre-
consumption specifications.” sales service to visualize your ideas.

We are using the most advanced production technologies and the most
demanding control systems to guarantee the highest quality and total
product reliability. Considerable investments have been made to upgrade
equipment, quality certification and laboratory testing facilities, in
particular for our low voltage transformer and LED lighting sectors.

Every product from Success is manufactured in accordance with industry


and international standards including ISO 9001. Our ability to meet the
customer’s requirements is constantly being evaluated and improved to
deliver more efficiency, effectiveness and flexibility to assure their benefit.
Quality Products & Services
power transformer

technical data standard series


standard compliance
· IEC 60076
· EN 61558

certifications
CE

primary / secondary voltage


range three phase single phase metal enclosure
· up to 1000V

capacity
introduction
· single phase
QPS Power Transformer is suitable for any industrial, commercial, manufacturing and production process
50VA ~ 100KVA
· three phase application. Power Transformer can be offered for a variety of environment conditions, for instance K factor
50VA ~ 2000KVA transformer, UPS transformer, and marine transformer. QPS transformer is safe, reliable and durable. Not
only do we produce top quality transformers but we also custom build transformers according to customers’
winding material design and specifications. With the continuous development in all phases of the design and manufacturing
· copper or aluminium
processes, we now offer dry-type transformers up to 2000KVA (2MVA).
· polyester enamelled wire
155°C (Class F) &
180°C (Class H) enclosures
· Fiberglass wire Enclosures for QPS transformers are manufactured from cold-rolled steel sheet and finished with epoxy
180°C (Class H) powder coat. Different Ingress Protection (IP) categories could be supplied upon request, which is up to IP44.
Enclosures can also be manufactured to meet customers’ special requirements.
silicon steel
· good quality, non grained
type testing
oriented and low loss
grained oriented Upon request, the following type test can be carried out at extra costs.
silicon steel · temperature rise test
Certifications by testing body are available upon request.
varnish
· high grade high temperature
accessories
polyester varnish
Optional accessories may be requested at an additional cost:

insulation class · over-current protection device: MCB / MCCB


· class F or H · surge protection device
· temperature measurement device
cooling · lamp indicator
· natural air cool
· castor wheels
· ventilation fan
ambient temperature
· maximum 40°C
facilities
metal enclosure protection class · foil winding machines
· standard: IP21 · wire winding machines
(other protection class
· vacuum impregnation facility
is available upon request)
· comprehensive testing equipment

Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
power transformer

three phase three phase two phase

k-factor transformer
The use of electronic equipment is growing rapidly in both the commercial and industrial sectors. These
electronic devices are powered by either switching power supplies or a rectifier circuit. Some examples of
these devices include UPS, computers, fax machines and printers. There are contributing to the distortion of
the current waveform and the generation of harmonics. Harmonics are defined as currents created by non-
linear loads, which generate non-linear current waveforms. Some of the examples in which the harmonics
presence include apparatus vibration, overheating of electrical equipment and electronic devices
malfunction.

K-Factor transformer is designed to withstand the harmonic distortion associated with these loads. It is
suitable for building security and as a bypass transformer for UPS systems, computers and peripherals,
telecommunication, laboratory instrumentation and office automation.

marine transformer
QPS marine transformer is safe and durable, which is produced for ships or vessels. The transformer is
manufactured in compliance with independent Marine Vessel requirements to maximize safety. The
transformer is naturally air-cooled mounted in IP rated metal enclosures. FAT by independent body could be
arranged upon customer’s request, at an extra cost.

Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
motor starting auto transf0rmer

capacity
· single tapping @ 70%
· three tapping @ 50%, 60%
and 75%

E-I silicon steel grade


· 0.5mm silicon steel

cooling
· natural air cool

safety
· thermostat protected for
transformer above 11KW

termination of wires
· high quality nylon
terminal block
· chrome steel metal
bolts & nuts

re-start frequencies
· maximum re-start
frequencies of
4 times per hour at
appropriate intervals

insulation class
· class F

optional
· customize designs are
available upon request

dimension
D W

D W

H H
Y

X Y

3.75kw to 132kw above 150kw

Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
motor starting auto transf0rmer

technical specification for aluminium wire

capacity hp thermostat no. of tapping mounting pitch (mm) overall dimension (mm) weight
(kw) tapping percentage x y w d h (kg)
3.75 5.0 nil/1 single 70% 120 185 215 195 90 5.5
5.5 7.5 nil/1 single 70% 120 185 215 195 95 6.5
7.5 10 nil/1 single 70% 120 185 215 195 100 7.0
11 15 nil/1 single 70% 140 210 240 215 100 9.5
11 15 1 three 50% 60% 75% 140 210 240 225 140 9.6
15 20 1 three 50% 60% 75% 140 210 240 225 155 11.5
22 30 1 three 50% 60% 75% 155 240 270 245 155 15.0
30 40 1 three 50% 60% 75% 155 240 270 245 160 16.5
37.5 50 1 three 50% 60% 75% 155 240 270 245 170 19.0
45 60 1 three 50% 60% 75% 185 270 300 275 170 20.5
56 75 1 three 50% 60% 75% 185 270 300 275 180 25.5
66 88 1 three 50% 60% 75% 185 270 300 275 210 34.0
80 107 1 three 50% 60% 75% 210 305 340 300 205 36.0
94 125 1 three 50% 60% 75% 210 305 340 300 215 41.0
110 150 1 three 50% 60% 75% 220 305 340 310 245 56.0
132 175 1 three 50% 60% 75% 220 305 340 310 255 61.0
150 200 3 three 50% 60% 75% 210 170 360 370 390 91.0
180 240 3 three 50% 60% 75% 260 170 410 380 400 105.0
225 300
3 three 50% 60% 75% 260 190 410 400 400 120.0

technical specification for copper wire

capacity hp thermostat no. of tapping mounting pitch (mm) overall dimension (mm) weight
(kw) tapping percentage x y w d h (kg)
3.75 5.0 nil/1 single 70% 120 185 215 195 90 6.1
5.5 7.5 nil/1 single 70% 120 185 215 195 95 7.5
7.5 10.0 nil/1 single 70% 120 185 215 195 100 8.6
11 (S) 15 nil/1 single 70% 140 210 240 215 100 10.7
11 3T 15 1 three 50% 60% 75% 140 210 240 225 145 12.4
15 20 1 three 50% 60% 75% 140 210 240 225 155 13.9
22 30 1 three 50% 60% 75% 155 240 270 245 150 17.3
30 40 1 three 50% 60% 75% 155 240 270 245 155 19.3
37.5 50 1 three 50% 60% 75% 155 240 270 245 155 21.1
45 60 1 three 50% 60% 75% 185 270 300 275 160 24.0
56 75 1 three 50% 60% 75% 185 270 300 275 180 30.3
66 88 1 three 50% 60% 75% 185 270 300 275 190 35.1
80 107 1 three 50% 60% 75% 210 305 340 300 210 42.3
94 125 1 three 50% 60% 75% 210 305 340 300 215 48.3
110 150 1 three 50% 60% 75% 220 305 340 310 235 62.5
132 175 1 three 50% 60% 75% 220 305 340 310 245 68.8
150 200 3 three 50% 60% 75% 210 170 360 370 390 100
180 240 3 three 50% 60% 75% 210 180 360 380 390 115
225 300
3 three 50% 60% 75% 210 190 360 390 390 130

Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
VARIABLE VOLTAGE transf0rmer

technical data

· high efficiency of greater


than 97%

· large cast aluminum carbon


brush holder plate for better
heat dissipation

· high-grade carbon brush


with less than 0.5mm wear
and tear after 100,000 introduction
cycles usage Variable voltage transformers are very convenient and useful where different voltages are required to
conduct tests or inspections. Examples are instrument calibration labs, QC department in the manufacturing
· metal casing coated with sector, etc. They are also suitable for use as step-up or step-down transformers in areas where supply voltage
epoxy paint to provide better is too low or too high.
surface protection
SETM is the first local manufacturer of variable voltage transformers in Malaysia under the company’s
· enamel wire of PEW 150°C brand QPS. QPS has catered a range of single phase from 5 to 60 Ampere and three phase from
grade provides better 5 to 30 Ampere variable voltage transformers to suit different customers’ needs.
working temperature
QPS variable voltage transformer uses high quality materials and stringent quality controls to ensure that
· improve starting current with only high quality products are produced at all times. QPS variable voltage transformer provides more than
the use of high quality just quality, reliability and compatibility; it also provides strong technical supports to our valuable customers.
grained oriented
silicon steel core

· insulation and withstand


voltage capable of reaching
up to 20M ohm at 500VDC
and 1.5kV respectively

Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
VARIABLE VOLTAGE transf0rmer

dimension
W
W
W
H

D H D
H D

type B type C type D

technical specification

model type maximum no. of input output overall weight


output phase voltage voltage dimensions (mm) (kg)
current (A) ( V) ( V) w d h
VT1-1 B 5 1 110 / 240 0 ~ 260 165 165 180 9
VT2-1 B 10 1 110 / 240 0 ~ 260 165 165 200 12
VT3-1 B 15 1 110 / 240 0 ~ 260 233 233 195 17
VT5-1 B 20 1 110 / 240 0 ~ 260 233 233 195 20
VT7-1 D 30 1 110 / 240 0 ~ 260 320 390 250 26
VT10-1 D 40 1 110 / 240 0 ~ 260 260 330 560 55
VT15-1 D 60 1 110 / 240 0 ~ 260 320 390 560 65
VT2-1-SC C 10 1 240 0 ~ 260 225 213 270 14
VT3-1-SC C 15 1 240 0 ~ 260 245 233 290 19
VT5-1-SC C 20 1 240 0 ~ 260 245 233 290 22
VT3-3 D 5 3 415 0 ~ 450 220 280 530 28
VT6-3 D 10 3 415 0 ~ 450 240 310 560 45
VT9-3 D 15 3 415 0 ~ 450 260 330 560 58
VT15-3 D 20 3 415 0 ~ 450 260 330 560 65
VT20-3 D 30 3 415 0 ~ 450 320 390 560 80
remarks: *SC - complete with socket

Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
DETUNED HARMONIC
CIRCUIT FILTER REACTOR

technical data
rated voltage
· 3 x 525V 50Hz &
440V 50Hz

filtering factor (uk)


· 7%

frequency of filter
· 189Hz
diagram

tolerance of inductance line

· ±5% A A
B B
linearity of inductance C C
· 1.3 x In

test voltage reactor

· 2.5kV

degree of protection
· IP 00

winding material
· copper or aluminium
· polyester enamelled wire
introduction
155°C (Class F) &
Power disturbance and harmonic distortion in electrical systems have proven to be fatal to equipment,
180°C (Class H)
cables, transformers, capacitor banks etc. The situation has deteriorated further with the use of products
· fibreglass wire 180°C
such as variable speed drives, soft starters, rectifiers, UPS, discharge lamp etc. These devices will generate or
(Class H)
increase the harmonic distortion and high frequency interference in the power system. These disturbances
will cause overheating to cables, transformer and related equipment etc.
reactor core
· 0.5mm high grade silicon steel
Detuned Harmonic Circuit Filter Reactor is used for:

·
from Japan & Korea
filtering harmonics and high frequency disturbance

varnish · reduce high inrush current (from parallel switching of capacitors & from power to capacitor banks
and thus improves the operating source life span of the capacitor)
· high grade high temperature
polyester varnish
Filtering % p is the ratio of inductance to capacitance. It is not to be confused with the impedance or
reactance of an inductor.
insulation class
For a 50Hz system:

·
· class F or H
p=7% = 189Hz is used where protection to capacitor and harmonics reduction is required

· p=6% = 204Hz is to be used where the system is rich in 5th harmonics and above

·
ambient temperature
p=13% = 139Hz is used where voltage distortion exceed permissible limit
· max 40°C

Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
DETUNED HARMONIC
CIRCUIT FILTER REACTOR

Technical Data (p=7%)


1. The reactor is manufactured to withstand 125% capacitor current (l1) at its rated operating voltage.
2. Harmonic current handling capacity (for p=7.0% detuned reactor):

·· l1 = 1.06 Ic (fundamental current)


l3 = 0.04 x l1 (3rd harmonic)
·· l5 = 0.31 x l1 (5th harmonic)
l5 = 0.13 x l1 (7th harmonic)
· lth = 1.25 x l1
3. Inductance tolerance is manufactured to be less than ± 5%.
4. Reactor Linearity still within 95~105% of their nominal inductance at 150% rated current. This assured maximum filtering of distortion
even in the presence of severe harmonics and best absorption of surges.
5. Saturation of iron core: The reactor will not saturate (a drop of 10% of the nominal inductance) at 175% of rated current.
6. Insulation-Class F 155°C. (Class H 180°C available upon request).
7. Operating Temperature: 100°C max. temperature rise at ambient temperature of 40°C . Thermostat 130°C (NC) is fitted to coil windings for
over temperature protection.
8. Testing: insulation strength tested at 2.5kV @ 1 minute.
9. Noise level: below 55dB - reactor not hum at no harmonics condition.

dimension

W D
W D

H
H

front view side view front view side view

type A type B

detuned harmonic circuit filter reactor 525V 50Hz 7%


technical specification

model model 525V capacitor rated inductance overall dimension (mm) weight
no. type rater power (KVAr) current (A) (mH) w d h (kg)
A5K07525 A 5 5.5 12.281 175 130 170 4.5
A10K07525 A 10 11 6.141 210 130 230 8.1
A15K07525 A 15 16.5 4.094 210 145 230 10.2
A20K07525 A 20 22 3.070 210 150 230 10.4
A25K07525 B 25 27.5 2.456 270 170 230 14.6
A30K07525 B 30 33 2.047 270 175 230 15.3
A40K07525 B 40 44 1.535 270 180 230 17.8
A50K07525 B 50 55 1.228 270 190 230 19.7
A60K07525 B 60 66 1.023 270 205 230 22.8
A75K07525 B 75 82.5 0.819 320 200 280 30.5
A80K07525 B 80 88 0.768 320 200 280 30.5
A100K07525 B 100 110 0.614 320 215 280 33
A120K07525 B 120 132 0.512 320 235 280 35.8
A150K07525 B 150 165 0.409 375 270 280 50
A160K07525 B 160 176 0.384 375 270 280 52.4
A200K07525 B 200 220 0.307 410 270 320 58
A300K07525 B 300 330 0.205 435 295 320 76

Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
LINE REACTOR

rated voltage
· 3 x 415V 50Hz

% impedance
· 4%

frequency
· 50Hz

test voltage
diagram
· 2.5kV

variable line motor line variable motor line load


degree of protection speed reactor load reactor speed load reactor
drive drive
· IP 00

rated current M M
· refer to table

winding material line reactor: line reactor: line reactor:


· copper or aluminium · reduce inrush current · suppresses interference and · suppresses interference
· polyester enamelled wire · reduce noise and transients generated from the coming from the electrical
155°C (Class F) & temperature of the motor electrical system system or load
180°C (Class H) · increase the life span of · smooth the harmonics · smooth the harmonics
· fiberglass wire semiconductors · reduce inrush current · reduce inrush current
180°C (Class H) · increase the life span of
semiconductors
reactor core
introduction
· 0.5mm high grade silicon steel
With the increase in demand for better quality products at minimum cost, new equipment or machines are
from Japan and Korea
being develop using electronic devices to meet individual requirements. One of the devices that has gone
through tremendous improvement is the variable speed drive. However, variable speed drives are very
varnish
sensitive to line fluctuations and other nuisance problems.
· high grade high temperature
polyester varnish
Line reactors offer an economical solution to a variety of problems especially in variable speed drive
installations. They act as current limiting device, as well as filters for electrical noises and harmonics
insulation class
generated from the loads. It is applicable to either the input or the output of the drives.
· class F or H

ambient temperature
· max 40°C

Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
LINE REACTOR

dimension

W D
W D

H
H

front view side view front view side view

type A type B

3 phase line reactor 415V 50Hz 4%


technical specification

model model type current (A) inductance (mH) dimensions (mm) weight
w d h (kg)
3LR8 A 8 3.813 175 130 170 3.9
3LR12 A 12 2.542 210 110 220 5.8
3LR18 A 18 1.695 210 125 220 7.5
3LR28 B 28 1.089 210 150 160 8.7
3LR40 B 40 0.763 210 165 160 10.9
3LR50 B 50 0.610 240 170 210 15.0
3LR63 B 63 0.484 240 180 210 17.4
3LR80 B 80 0.381 270 180 210 19.1
3LR125 B 125 0.244 270 205 210 26.6
3LR160 B 160 0.191 300 200 260 34.7
3LR200 B 200 0.153 315 220 260 38.0

Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
v-SERIES AUTOMATIC VOLTAGE STABILIZER

technical data
input voltage
· single phase: 230V ±12%
· three phase: 415V ±12%
+ neutral

output voltage (true rms)


· single phase: 230VAC ±1.5%
· three phase: 415VAC ±1.5%

voltage fluctuation
rated kva In the real world power line voltage occurs frequently especially in industrial area. Every electrical
· single phase: 1KVA ~ 30KVA equipments and devices do have a working voltage limit/tolerance. Some equipment are build to tolerate
· three phase: 3KVA ~150KVA ±10% of nominal voltage while others ±5% or less depending on sensitivity.

output waveform/ effects


The correct operation of electrical and electronic equipment depends on the voltage accuracy and stability.
distortion
In the event of long time over voltage, it will lead to damage of the equipment; while long time under
· sinewave/follow input voltage will cause malfunction and computation errors of the electrical & electronic equipment.

response time solutions


· 0.05 ~ 0.07 sec/V Installing QPS Automatic Voltage Stabilizer (AVS) or power line conditioner will ensure the continuity and
quality of production.
Input voltage variation from:
frequency
Single Phase: 230VAC ±12%
· 50 / 60Hz Three Phase: 415VAC ±12% + Neutral (3 phase 4 wire)
- excellent output voltage accuracy of within ±1.5% set value.
efficiency - regulation correction time approximately 0.05 ~ 0.07 sec per volt.
· > 95% - minimum maintenance due to its simplicity in design.
- easy installation.
- tailor made to special voltages and configuration for example, three phase voltage without neutral or for
over current protection
outdoor configurations.
· MCB / MCCB

QPS Servo - Motor Automatic Voltage Stabilizer provides a continuous monitoring of the output voltage
operating temperature (true RMS sensing) by means of an electronic Control Circuit that compares the instantaneous output voltage
· 0°C ~ 45°C with the set value. When changes are detected due to fluctuation of supply voltage or sudden changes in
load, an electrical signal will be transmitted to the servo – motor which is coupled onto the brush gear of the
SPD surge protection variable transformer, causes the brush gear to rotate until the appropriate voltage is restored. This method
of stabilization does not create interference or harmonic to the supply system. QPS Three phase Automatic
· 1 phase standard
Volltage Stabilizer also designed to cater for unbalanced load. This made possible with its independent
· 3 phase (optional) phase monitoring system.

phase loss sensing QPS Automatic Voltage Stabilizer offer high quality performance at competitive prices. They solve voltage
protection unstable problems and increase productivity.
· phase sensing relay (optional)
power line conditioner

automatic output delay QPS power line conditioner (PLC) is a AVS with the inclusion of a shielded isolation transformer.
on system
· time delay (optional)

Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
v-SERIES AUTOMATIC VOLTAGE STABILIZER

applications
· CNC wire-cut / EDM · Broadcasting equipment
· CNC drilling machine · Photographic processing equipment
· CNC milling machine · Photocopy machine
· X – Ray equipment · Test equipment
· Industrial robots · Computers
· Communication system · Medical equipment
· PLC equipment · LAB equipment

standard features
. over current circuit breaker
. analog voltmeter
. phase indicator lamps
. phase selector switch for voltmeter (for three phase only)

optional features
. surge protection device (SPD)
. phase loss (3 phase model) c/w programmable under / over voltage detector / phase sequence monitoring
. automatic output delay on system
. manual bypass switch

single phase standard fittings


single phase models
standard fittings come with phase pilot lamp, over current breaker and voltmeter with selector switch.

input termination
power cord c/w 13A BS 3 pin plug – (model 1KVA, 2KVA & 3KVA)
power cord c/w 15A BS 3 pin plug – (model 4KVA)
terminal block for hardwire – (model 5KVA ~ 30KVA)

output termination
13A BS 3 pin socket – (model 1KVA ~ 15KVA)
terminal block for hardwire – (model 3KVA ~ 30KVA)

three phase standard fittings


over current breaker – (model 3KVA ~ 150KVA)
voltmeter input – line / phase voltage – (model 30KVA ~ 150KVA)
voltmeter output – (model 3KVA ~ 150KVA)

phase pilot lamp, input and output termination


terminal block – (model 3KVA ~ 150KVA)

diagram

Single Phase & Three Phase Servo – Motor Voltage Stabilizer Block Diagram

Legend

ST – series transformer ECC – electric control circuit


VR – variable transformer M – servo-motor ST1
R R
ST ST2
L L Y Y
ST3
B B
input VR stabilized input
VR1 VR2 VR3 stabilized
output output
N N
M ECC
N N

M ECC M ECC M ECC


* single phase avs / avr
single phase avs
/ avr 3-phase avs / avr independent phase control

* three phase avs / avr independent phase control

Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
v-SERIES SINGLE PHASE
AUTOMATIC VOLTAGE STABILIZER

dimension
D W
W W
D D

D
D D
W W H
H H
H H
H

CABINET 1
CABINET 1
CABINET 3 CABINET 4
cabinet 1 cabinet 2 cabinet 3

single phase V-series 230VAC


technical specification

model cabinet power rated rated / output input voltage output accuracy dimensions (mm) (+/-) weight (kg)
output (KVA) current (A) variation (%) h w d (+/-)
VSS1 - 2 1 1 4 230V ± 12% ±1.5% 183 200 220 8
VSS2 - 2 1 2 9 230V ± 12% ±1.5% 200 230 245 10
VSS3 - 2 1 3 13 230V ± 12% ±1.5% 283 260 330 23
VSS4 - 2 1 4 17 230V ± 12% ±1.5% 283 260 330 24
VSS5 - 2 1 5 22 230V ± 12% ±1.5% 283 260 330 24
VSS7 - 2 2 7.5 33 230V ± 12% ±1.5% 370 270 560 45
VSS10 - 2 2 10 43 230V ± 12% ±1.5% 370 270 560 50
VSS15 - 2 2 15 65 230V ± 12% ±1.5% 370 270 560 53
VSS20 - 2 3 20 87 230V ± 12% ±1.5% 640 400 375 57
VSS25 - 2 3 25 109 230V ± 12% ±1.5% 640 400 375 68
VSS30 - 2 3 30 130 230V ± 12% ±1.5% 640 400 375 73

remarks: The dimensions indicated above is applicable for Automatic Voltage Stabilizer only. Please refer to the staff for power line conditioner dimensions if required.

Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
D
v-SERIES THREE PHASE
W AUTOMATIC VOLTAGE STABILIZER

dimension
D
H W
W
D

CABINET 1
cabinet 1 cabinet 2

three phase V-series 415VAC


technical specification

model cabinet power rated rated / output input voltage output accuracy dimensions (mm) (+/-) weight (kg)
output (KVA) current (A) variation (%) h w d (+/-)
VST3 - 4 1 3 4 415V ± 12% ±1.5% 530 295 460 32
VST6 - 4 1 6 8 415V ± 12% ±1.5% 530 295 460 36
VST10 - 4 1 10 14 415V ± 12% ±1.5% 660 360 600 75
VST15 - 4 1 15 21 415V ± 12% ±1.5% 660 360 600 78
VST20 - 4 1 20 28 415V ± 12% ±1.5% 660 360 600 96
VST25 - 4 1 25 35 415V ± 12% ±1.5% 660 360 600 107
VST30 - 4 1 30 42 415V ± 12% ±1.5% 700 380 810 115
VST40 - 4 1 40 56 415V ± 12% ±1.5% 700 380 810 128
VST45 - 4 1 45 63 415V ± 12% ±1.5% 700 380 810 134
VST50 - 4 1 50 70 415V ± 12% ±1.5% 700 380 810 136
VST60 - 4 1 60 84 415V ± 12% ±1.5% 700 380 810 180
VST75 - 4 1 75 104 415V ± 12% ±1.5% 815 475 1070 213
VST100 - 4 1 100 139 415V ± 12% ±1.5% 815 475 1070 248
VST125 - 4 1 125 174 415V ± 12% ±1.5% 815 475 1070 270
VST150 - 4 2 150 209 415V ± 12% ±1.5% 1490 660 580 385

remarks: The dimensions indicated above is applicable for Automatic Voltage Stabilizer only. Please refer to the staff for power line conditioner dimensions if required.

Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
S-SERIES AUTOMATIC VOLTAGE STABILIZER

technical data
input voltage
· single phase: 230V ± 15%
· three phase: 415V ± 15%/10%
+ neutral

output voltage (true rms)


· single phase: 230VAC ± 1.5%
· three phase: 415VAC ±1.5%

rated kva voltage fluctuation


· single phase: 1KVA ~ 30KVA In the real world power line voltage occurs frequently especially in industrial area. Every electrical
equipments and devices do have a working voltage limit/tolerance. Some equipment are build to tolerate
· three phase: 3KVA ~ 1000KVA
±10% of nominal voltage while others ±5% or less depending on sensitivity.

output waveform/ effects


distortion The correct operation of electrical and electronic equipment depends on the voltage accuracy and stability.
· sinewave/follow input In the event of long time over voltage, it will lead to damage of the equipment; while long time under
voltage will cause malfunction and computation errors of the electrical & electronic equipment.
response time
solutions
· 0.05 ~ 0.07 sec/V
Installing QPS Automatic Voltage Stabilizer (AVS) or power line conditioner will ensure the continuity and
quality of production.
frequency Input voltage variation from:
· 50 / 60Hz Single Phase: 230V ± 15%
Three Phase: 415V ± 15% + Neutral (3 phase 4 wire)
- excellent output voltage accuracy of within ±1.5% set value.
efficiency
- regulation correction time approximately 0.05 ~ 0.07 sec per volt.
· > 95%
- minimum maintenance due to its simplicity in design.
- easy installation.
operating temperature - tailor made to special voltages and configuration for example, three phase voltage without neutral or for
· 0°C ~ 45°C outdoor configurations.

over current protection QPS Servo - Motor Automatic Voltage Stabilizer provides a continuous monitoring of the output voltage
(true RMS sensing) by means of an electronic Control Circuit that compares the instantaneous output voltage
· MCB / MCCB
with the set value. When changes are detected due to fluctuation of supply voltage or sudden changes in
load, an electrical signal will be transmitted to the servo – motor which is coupled onto the brush gear of the
SPD surge protection variable transformer, causes the brush gear to rotate until the appropriate voltage is restored. This method
· 1 phase standard of stabilization does not create interference or harmonic to the supply system. QPS Three phase Automatic
· 3 phase (optional) Volltage Stabilizers also designed to cater for unbalanced load. This made possible with its independent
phase monitoring system.
phase loss sensing
protection QPS Automatic Volltage Stabilizers offer high quality performance at competitive prices. They solve voltage
unstable problems and increase productivity.
· phase sensing relay (optional)

power line conditioner


automatic output delay QPS power line conditioner (PLC) is a AVS with the inclusion of a shielded isolation transformer.
on system
· time delay (optional)

Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
S-SERIES AUTOMATIC VOLTAGE STABILIZER

applications
· CNC wire-cut / EDM · Broadcasting equipment
· CNC drilling machine · Photographic processing equipment
· CNC milling machine · Photocopy machine
· X – Ray equipment · Test equipment
· Industrial robots · Computers
· Communication system · Medical equipment
· PLC equipment · LAB equipment

standard features
. over current circuit breaker
. analog voltmeter
. phase indicator lamps
. phase selector switch for voltmeter

optional features
. surge protection device (SPD)
. over current protection (for model above 150KVA)
. phase loss / phase sequence monitoring (3 phase model)
. automatic output delay on system
. manual bypass switch

single phase standard fittings


single phase models
standard fittings come with phase pilot lamp, over current breaker and voltmeter with selector switch.

input termination
power cord c/w 13A BS 3 pin plug – (model 1KVA , 2KVA & 3KVA)
power cord c/w 15A BS 3 pin plug – (model 4KVA)
terminal block for hardwire – (model 5KVA ~ 30KVA)

output termination
13A BS 3 pin socket – (model 1KVA ~ 5KVA)
terminal block for hardwire – (model 5KVA ~ 30KVA)

three phase standard fittings


over current breaker – (model 3KVA ~ 150KVA)
phase selector switch for output voltmeter – (model 3KVA ~ 15KVA)
phase selector switch for input & output voltmeter – (model 20KVA ~ 50KVA)
phase selector switch for output voltmeter & ammeter – (model 60KVA ~ 200KVA)
phase selector switch for input, output voltmeter & output ammeter – (model 250KVA ~ 1000KVA)
phase indicator lamps (output)
input & output terminal block (model 3KVA ~ 150KVA)

diagram
Single Phase & Three Phase Servo – Motor Voltage Stabilizer Block Diagram

Legend

ST – series transformer ECC – electric control circuit


VR – variable transformer M – servo-motor ST1
R R
ST ST2
L L Y Y
ST3
B B
input VR stabilized input
VR1 VR2 VR3 stabilized
output output
N N
M ECC
N N

single phase avs / avr M ECC M ECC M ECC


* single phase avs / avr 3-phase avs / avr independent phase control
Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ
* three phase avsfrom
/ avrthe actual product.
independent phase control
S-SERIES SINGLE PHASE
AUTOMATIC VOLTAGE STABILIZER

D W D W
dimension

W W
D D
H D W HD W

H H H H

NET 4 CABINET
CABINET35 CABINET 4 CABINET 5 CABINET 3 CA
cabinet 1 cabinet 2 cabinet 3

single phase S-series 230VAC

technical specification

model cabinet power rated rated / output input voltage output accuracy dimensions (mm) (+/-) weight (kg)
output (KVA) current (A) variation (%) h w d (+/-)
S1 − 2 1 1 4 230V ± 15% ± 1.5% 260 280 335 12
S2 − 2 1 2 9 230V ± 15% ± 1.5% 260 280 335 14
S3 − 2 1 3 13 230V ± 15% ± 1.5% 260 280 335 21
S4 − 2 1 4 17 230V ± 15% ± 1.5% 260 280 335 21.5
S5 − 2 2 5 22 230V ± 15% ± 1.5% 275 260 500 34
S7 − 2 2 7.5 33 230V ± 15% ± 1.5% 370 270 560 40
S10 − 2 2 10 43 230V ± 15% ± 1.5% 370 270 560 46.5
S15 − 2 2 15 65 230V ± 15% ± 1.5% 370 270 560 54
S20 − 2 3 20 87 230V ± 15% ± 1.5% 640 400 375 64
S25 − 2 3 25 109 230V ± 15% ± 1.5% 640 400 375 75
S30 − 2 3 30 130 230V ± 15% ± 1.5% 640 400 375 83

remarks: The dimensions indicated above is applicable for Automatic Voltage Stabilizer only. Please refer to the staff for power line conditioner dimensions if required.

*available upon request

special casing* frame type frame type

Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
S-SERIES THREE PHASE
AUTOMATIC VOLTAGE STABILIZER
D
W

D
W

D
H W

W
D D
H W

H H

CABINET 1
cabinet 1 cabinet 2 cabinet 3
CABINET 1

three phase S-series 415VAC

technical specification

model cabinet power rated rated / output input voltage output accuracy dimensions (mm) (+/-) weight (kg)
output (KVA) current (A) variation (%) h w d (+/-)
T3 − 4 1 3 4 415V±15% ± 1.5% 665 320 585 45
T6 − 4 1 6 8 415V±15% ± 1.5% 665 320 585 50
T10 − 4 1 10 14 415V±15% ± 1.5% 665 320 585 75
T15 − 4 1 15 21 415V±15% ± 1.5% 665 320 585 77
T20 − 4 2 20 28 415V±15% ± 1.5% 1110 570 500 159
T30 − 4 2 30 42 415V±15% ± 1.5% 1110 570 500 165
T40 − 4 2 40 56 415V±15% ± 1.5% 1110 570 500 180
T45 − 4 2 45 63 415V±15% ± 1.5% 1110 570 500 182
T50 − 4 2 50 70 415V±15% ± 1.5% 1110 570 500 190
T60 − 4 2 60 83 415V±15% ± 1.5% 1110 570 500 211
T75 − 4 2 75 104 415V±15% ± 1.5% 1110 570 500 225
T100 − 4 2 100 139 415V±15% ± 1.5% 1275 660 580 300
T125 − 4 2 125 174 415V±15% ± 1.5% 1275 660 580 345
T150 − 4 2 150 209 415V±15% ± 1.5% 1490 660 580 385
T200 − 4 2 200 278 415V±10% ± 1.5% 1490 660 580 380
T250 − 4 3 250 348 415V±10% ± 1.5% 1740 1400 800 550
T300 − 4 3 300 417 415V±10% ± 1.5% 1740 1400 800 732
T400 − 4 3 400 556 415V±10% ± 1.5% 1740 1400 800 986
T500 − 4 3 500 695 415V±10% ± 1.5% 1740 1400 800 1100
T600 − 4 3 600 835 415V±10% ± 1.5% 1955 1600 1400 1200
T700 − 4 3 700 974 415V±10% ± 1.5% 1955 1600 1400 1700
T1000 − 4 3 1000 1391 415V±10% ± 1.5% 1955 1600 1400 2000

remarks: The dimensions indicated above is applicable for Automatic Voltage Stabilizer only. Please refer to the staff for power line conditioner dimensions if required.

Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
CURRENT TRANSFORMER

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
CURRENT TRANSFORMER

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
RING TYPE - PVC TAPE SERIES

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
Casing type - mbq series

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
Casing type - msq series

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
AUTOMoTIve lead acid
battery charger series

introduction
Lead Acid Battery Chargers are designed to cater for high volume battery charging
up to 9 pieces of 12V battery or 18 pieces of 6V battery connected in series. This is made possible
with the use of multiple voltage and current selections to provide various combinations of charging
conditions to suit individual requirement.

They are supplied in heavy gauge steel casing complete with epoxy powder coated finishing and
come in two different designs of fixed and multiple voltage/current selections.

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
AUTOMoTIve lead acid
battery charger series

technical specification
input voltage 220Vac - 240Vac 1 phase 50Hz
(for all models)

model STM 1205 STM 1210 STM 1215 STM 2410


output 12Vdc 12Vdc 12Vdc 12Vdc ~ 24Vdc
max charging current max 5Amp max 10Amp max 15Amp max 10Amp
(low & high select) (low & high select) (low & high select) (selectable)
safety protection input fuse 2Amp, input fuse 2Amp, input fuse 2Amp, input fuse 3Amp,
output auto fuse 7.5Amp output auto fuse 15Amp output MCB 16Amp output MCB 16Amp
dimension (h x w x d) (120 x 160 x 210) mm (120 x 160 x 210) mm (135 x 180 x 225) mm (160 x 240 x 260) mm
weight 3.5kg 5.0kg 6.0kg 11.0kg

model STM 2420 STM 4810


STM 4820
output 12Vdc ~ 24Vdc 6Vdc ~ 48Vdc 6Vdc ~ 48Vdc
max charging current max 20Amp max 10Amp max 20Amp
(selectable) (selectable) (selectable)
safety protection input fuse 5Amp, input fuse 5Amp, input fuse 8Amp,
output MCB 25Amp output MCB 15Amp output MCB 25Amp
dimension (h x w x d) (300 x 340 x 330) mm (300 x 340 x 330) mm (300 x 340 x 330) mm
weight 21.0kg 18.5kg 24.5kg

model: STM 2410 model:


340 STM 4810 / STM 4820 330

240 260 340 330 340

SUPER-LITE BATTERY CHARGER


STM-4820 SUPER-LITE BATTERY CHAR GER
STM-4810
SUPER-LITE CURRENT ADJUSTOR CURR ENT ADJUSTOR
BATTERY CHARGER STM - 2410 MAINS OFF MAINS
OFF
A
-
BATTERY CHARGER
A
MAINS
OUTPUT D.C.
CHARGING RATE
220V ~ 240V A.C.
12V ~ 24V D.C.
1~ 10A
7 1
- 7 1

No. of Batteries 2 x 12V or 4 x 6V


6 2 6 2

CURRENT ADJUSTOR OUTPUT

300
OUTPUT
2 3 START 24V MAINS 5 3 5 3
4
1

4
OFF

VOLTAGE SELECTOR
5

D.C. VOLTAGE SELECTOR


OUTPUT OFF OFF
BATTERY CHARGER BATTERY CHARGER

48V 6V MODEL STM-4820 48V 6V MODEL STM-4810

12V ON MAINS 220V ~ 240V A.C.


MAINS 220V ~ 240V A.C.
OUTPUT D.C. 6V~ 48V D.C.
OUTPUT D.C. 6V~ 48V D.C.
CHARGING RATE 1 ~ 20 Amps
CHARGING RATE 1 ~ 20 Amps

36V 12V D.C. No. of Batteries 4 x 12V or 8 x 6V 36V 12V D.C. No. of Batteries 4 x 12V or 8 x 6V

OUTPUT OUTPUT
24V 24V

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
AUTOMoTIve lead acid
battery charger series

technical specification
input voltage 220Vac - 240Vac 1 phase 50Hz
(for all models)

model STM 9610 / STM 10810 SE 715 / SE 915


output 6Vdc ~ 96Vdc / 12Vdc ~ 108Vdc 12Vdc ~ 84Vdc / 12Vdc ~ 108Vdc
max charging current max 10Amp max 15Amp
(selectable) (selectable)
safety protection input fuse 8Amp, input fuse 15Amp,
output MCB 15Amp output MCB 20Amp
dimension (h x w x d) (300 x 340 x 330) mm (485 x 580 x 320) mm
weight 24.0kg / 26.kg 41.0kg / 48.0kg

model: STM 9610 / STM 10810 model: SE 715 / SE 915

SUPER-LITE BATTERY CHARGER


STM-10810

CURRENT ADJUSTOR
OFF MAINS
A
7 1
-
6 2

300
OUTPUT
5 3
4
VOLTAGE SELECTOR
OFF 12V
BATTERY CHARGER
24V

108V 36V

6V 48V D.C.
OUTPUT
84V 60V
72V

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
battery charger /
engine starter

introduction
. Mobile Battery Charger / Engine Starter has a range of features including variable
charge rates and powerful boost facility. It is designed for the charging battery and keeping the
vehicles on the move
. Used as slow & fast charger and booster
. Equipped with timer for fast charging and auto stop purposes
. Selectable battery voltage range control (12V & 24V)
. Input and output breaker protection
. Variable and adjustable charging current control
. Fitted with rubber wheels and handle for instant mobility
. Built-in MCB against overloads and polarity inversion
. Selectable charging current control
. Robust in design and maintenance free
. Easy to operate, reliable and economical

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
battery charger /
engine starter

STM 2460 SMART 450

technical specification
model: STM 2460 model: SMART 450
input voltage 220Vac ~ 240Vac input voltage 220Vac ~ 240Vac
1 phase 50Hz 1 phase 50Hz
cranking power 350Amp cranking power 450Amp
charging voltage 12Vdc ~ 24Vdc charging voltage 12Vdc ~ 24Vdc
charging current 1 ~ 60Amp (adjustable) charging current 1 ~ 60Amp (selectable)
output 12V start - 4.2KW output 12V start - 5.4KW
24V start - 8.4KW 24V start - 10.8KW
weight 51.5kg weight 38kg

. A mobile charger / starter designed for the garage and fleet . A mobile starter / charger designed for the garage and fleet
. Operator with modern - style metal casing . Operator with modern - style metal casing
. Used as slow & fast charger and booster . Used as slow & fast charger and booster
. Equipped with timer for fast charging and auto stop purposes . Selectable battery voltage range (12V & 24V)
. Selectable battery voltage range control (12V & 24V) . Input breaker protection
. Input and output breaker protection . Selectable charging current control
. Variable and adjustable charging current control . Fitted with rubber wheels and handle for instant mobility
. Fitted with rubber wheels and handle for instant mobility . Robust in design and maintenance free
. Build-in MCB against overloads and polarity . Easy to operate, reliable and economical

dimensions
model: STM 2460 model: SMART 450
360 280
300 280
250

820
690 490 550

500 150 420 70 130

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
constant current
battery charger

A fully automated constant current charger designed for charging high volume unformed
lead acid batteries. Charging current can be adjusted easily to provide the most suitable
combination of charging current accordingly.

Due to its unique design, charging of batteries having different voltages is possible by simply
connecting the batteries in series without exceeding the rated maximum DC voltage of the
charger. To increase the quantity of batteries per charge, parallel connection as groups of
batteries is allowed.

A charging timer is incorporated to provide presetting of charging time. The systems will
shutdown once the preset time is reached.

constant current battery charger is very economical, easy to operate and


maintenance free. It is most suitable for battery manufacturing industries and workshops.

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
constant current
battery charger

STM 15015 STM 15030

technical specification technical specification


model: STM 15015 model: STM 15030
input voltage 220Vac ~ 240Vac input voltage 220Vac ~ 240Vac
1 phase 50Hz 1 phase 50Hz
output voltage 150Vdc output voltage 150Vdc
charging current max 0 ~ 15Amp (adjustable) charging current max 0 ~ 30Amp (adjustable)
safety protection input MCB 20Amp safety protection input MCB 40Amp
output MCB 20Amp output MCB 40Amp
time setting 0 ~ 99hrs time setting 0 ~ 99hrs
current & voltage display analog DCA & DCV panel meters current & voltage display analog DCA & DCV panel meters
enclosure finishing epoxy powder coated enclosure finishing epoxy powder coated
dimension (h x w x d) (400 x 590 x 410) mm dimension (h x w x d) (500 x 760 x 510) mm
weight 75.5kg weight 132.5kg

dimensions

model: STM 15015 model: STM 15030


760 510
590 410 760 510
590 410

500
400
500
400

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
automatic traction
battery charger series

Automatic Battery Chargers is specially designed for charging Electrical


Truck batteries. Our range of Traction battery charger is able to meet the demand of different
brands of battery use in Electrical Truck. The batteries condition and reliability is of the highest
importance to get the Electrical Truck moving. The sophisticated design of
Automatic Traction Battery Charger ensures that the battery is fully recharged.

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
automatic traction
battery charger series

S-Series

technical specification
main supply single phase 240V (V/cell)
(1 %)

frequency 50 / 60Hz
2,6
U
DC output voltage 12V, 24V, 36V and 48V 2,4
100 2,0
DC output current 10A up to 60A
indicators power on, 80% charged, 100% charged, 50
equalizing and safety timer
I
protection input MCB and output HRC fuse 25

overload protection current limiting t


HOUR 1 2 3 4 5 6 7 8 9 10
operating temperature 0 to 40°C
enclosure finishing mild steel coated with epoxy features
. u - charging voltage curve
. I - charging current curve
. t - charging time
automatic traction battery charger is an evolution in
electrical truck battery charging. It is fully automatic, robust & simple to
operate and comes in single phase input.

features
. fully automatic two steps charging
. Thyristor controlled rectification
. protected by a 13 hours security timer
. WOWa charging mode
. equalizing cycle

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
automatic traction
battery charger series

S-Series

technical specification
model type AC input battery capacity charging time
RC 1210-S 12V / 10A 1 Ø 240V @ 50Hz 50 ~ 65 Ah 9 - 12hrs
RC 1215-S 12V / 15A 1 Ø 240V @ 50Hz 65 ~ 95 Ah 9 - 12hrs
RC 1220-S 12V / 20A 1 Ø 240V @ 50Hz 95 ~125 Ah 9 - 12hrs
RC 1225-S 12V / 25A 1 Ø 240V @ 50Hz 125 ~ 155 Ah 9 - 12hrs
RC 1230-S 12V / 30A 1 Ø 240V @ 50Hz 155 ~190 Ah 9 - 12hrs
RC 1240-S 12V / 40A 1 Ø 240V @ 50Hz 190 ~ 250 Ah 9 - 12hrs
RC 1250-S 12V / 50A 1 Ø 240V @ 50Hz 250 ~ 315 Ah 9 - 12hrs
RC 1260-S 12V / 60A 1 Ø 240V @ 50Hz 315 ~ 375 Ah 9 - 12hrs
RC 2410-S 24V / 10A 1 Ø 240V @ 50Hz 50 ~ 65 Ah 9 - 12hrs
RC 2415-S 24V / 15A 1 Ø 240V @ 50Hz 65 ~ 95 Ah 9 - 12hrs
RC 2420-S 24V / 20A 1 Ø 240V @ 50Hz 95 ~ 125 Ah 9 - 12hrs
RC 2425-S 24V / 25A 1 Ø 240V @ 50Hz 125 ~ 155 Ah 9 - 12hrs
RC 2430-S 24V / 30A 1 Ø 240V @ 50Hz 155 ~ 190 Ah 9 - 12hrs
RC 2440-S 24V / 40A 1 Ø 240V @ 50Hz 190 ~ 250 Ah 9 - 12hrs
RC 2450-S 24V / 50A 1 Ø 240V @ 50Hz 250 ~ 315 Ah 9 - 12hrs
RC 2460-S 24V / 60A 1 Ø 240V @ 50Hz 315 ~ 375 Ah 9 - 12hrs
RC 3630-S 36V / 30A 1 Ø 240V @ 50Hz 155 ~ 190 Ah 9 - 12hrs
RC 3640-S 36V / 40A 1 Ø 240V @ 50Hz 190 ~ 250 Ah 9 - 12hrs
RC 3650-S 36V / 50A 1 Ø 240V @ 50Hz 250 ~ 315 Ah 9 - 12hrs
RC 3660-S 36V / 60A 1 Ø 240V @ 50Hz 315 ~ 375 Ah 9 - 12hrs
RC 4830-S 48V / 30A 1 Ø 240V @ 50Hz 155 ~ 190 Ah 9 - 12hrs
RC 4840-S 48V / 40A 1 Ø 240V @ 50Hz 190 ~ 250 Ah 9 - 12hrs
RC 4850-S 48V / 50A 1 Ø 240V @ 50Hz 250 ~ 315 Ah 9 - 12hrs
RC 4860-S 48V / 60A 1 Ø 240V @ 50Hz 315 ~ 375 Ah 9 - 12hrs
note: other capacity is available upon request.

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
automatic traction
battery charger series

T-Series

technical specification
main supply three phase 415V
(V/cell)
(1 %)

frequency 50 / 60Hz
2,6
DC output voltage 12V, 24V, 36V, 48V, 72V and 80V U
2,4
DC output current 30A up to 220A 100 2,0

indicators power on, 80% charged, 100%


charged, equalizing and safety timer 50

I
protection input MCB and output HRC fuse
25
overload protection current limiting
HOUR 1 2 3 4 5 6 7 8 9 10 t
operating temperature 0 to 40°C
enclosure finishing mild steel coated with epoxy features
. u - charging voltage curve
. I - charging current curve
automatic traction battery charger is an evolution . t - charging time
in electrical truck battery charging. It is fully automatic, robust &
simple to operate and comes in single phase input.

features
. fully automatic two steps charging
. Thyristor controlled rectification
. protected by a 13 hours security timer
. WOWa charging mode
. equalizing cycle

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
automatic traction
battery charger series

T-Series

technical specification
model type AC input battery capacity charging time
RC 2440-T 24V / 40A 3 Ø 415V @ 50Hz 185 ~ 250 Ah 9 - 12hrs
RC 2460-T 24V / 60A 3 Ø 415V @ 50Hz 250 ~ 375 Ah 9 - 12hrs
RC 2480-T 24V / 80A 3 Ø 415V @ 50Hz 375 ~ 500 Ah 9 - 12hrs
RC 24100-T 24V / 100A 3 Ø 415V @ 50Hz 500 ~ 625 Ah 9 - 12hrs
RC 24120-T 24V / 120A 3 Ø 415V @ 50Hz 625 ~ 750 Ah 9 - 12hrs
RC 24140-T 24V / 140A 3 Ø 415V @ 50Hz 750 ~ 875 Ah 9 - 12hrs
RC 24160-T 24V / 160A 3 Ø 415V @ 50Hz 875 ~ 1000 Ah 9 - 12hrs
RC 24180-T 24V / 180A 3 Ø 415V @ 50Hz 1000 ~ 1125 Ah 9 - 12hrs
RC 3650-T 36V / 50A 3 Ø 415V @ 50Hz 180 ~ 250 Ah 9 - 12hrs
RC 3660-T 36V / 60A 3 Ø 415V @ 50Hz 250 ~ 375 Ah 9 - 12hrs
RC 3680-T 36V / 80A 3 Ø 415V @ 50Hz 375 ~ 500 Ah 9 - 12hrs
RC 36100-T 36V / 100A 3 Ø 415V @ 50Hz 500 ~ 625 Ah 9 - 12hrs
RC 36120-T 36V / 120A 3 Ø 415V @ 50Hz 625 ~ 750 Ah 9 - 12hrs
RC 36140-T 36V / 140A 3 Ø 415V @ 50Hz 750 ~ 875 Ah 9 - 12hrs
RC 36160-T 36V / 160A 3 Ø 415V @ 50Hz 875 ~ 1000 Ah 9 - 12hrs
RC 36180-T 36V / 180A 3 Ø 415V @ 50Hz 1000 ~ 1125 Ah 9 - 12hrs
RC 36200-T 36V / 200A 3 Ø 415V @ 50Hz 1125 ~ 1200 Ah 9 - 12hrs
RC 36220-T 36V / 220A 3 Ø 415V @ 50Hz 1200 ~ 1320 Ah 9 - 12hrs
RC 4840-T 48V / 40A 3 Ø 415V @ 50Hz 170 ~ 250 Ah 9 - 12hrs
RC 4860-T 48V / 60A 3 Ø 415V @ 50Hz 250 ~ 375 Ah 9 - 12hrs
RC 4880-T 48V /80A 3 Ø 415V @ 50Hz 375 ~ 500 Ah 9 - 12hrs
RC 48100-T 48V / 100A 3 Ø 415V @ 50Hz 500 ~ 625 Ah 9 - 12hrs
RC 48120-T 48V / 120A 3 Ø 415V @ 50Hz 625 ~ 750 Ah 9 - 12hrs
RC 48140-T 48V / 140A 3 Ø 415V @ 50Hz 750 ~ 875 Ah 9 - 12hrs
RC 48160-T 48V / 160A 3 Ø 415V @ 50Hz 875 ~ 1000 Ah 9 - 12hrs
RC 48180-T 48V / 180A 3 Ø 415V @ 50Hz 1000 ~ 1125 Ah 9 - 12hrs
RC 48200-T 48V / 200A 3 Ø 415V @ 50Hz 1125 ~ 1200 Ah 9 - 12hrs
RC 48220-T 48V / 220A 3 Ø 415V @ 50Hz 1200 ~ 1320 Ah 9 - 12hrs
RC7260-T 72V / 60A 3 Ø 415V @ 50Hz 250 ~ 375 Ah 9 - 12hrs
RC7280-T 72V / 80A 3 Ø 415V @ 50Hz 375 ~ 500 Ah 9 - 12hrs
RC72100-T 72V / 100A 3 Ø 415V @ 50Hz 500 ~ 625 Ah 9 - 12hrs
RC72120-T 72V / 120A 3 Ø 415V @ 50Hz 625 ~ 750 Ah 9 - 12hrs
RC72140-T 72V / 140A 3 Ø 415V @ 50Hz 750 ~ 875 Ah 9 - 12hrs
RC72160-T 72V / 160A 3 Ø 415V @ 50Hz 875 ~ 1000 Ah 9 - 12hrs
RC72180-T 72V / 180A 3 Ø 415V @ 50Hz 1000 ~ 1125 Ah 9 - 12hrs
RC72200-T 72V / 200A 3 Ø 415V @ 50Hz 1125 ~ 1200 Ah 9 - 12hrs
RC8060-T 80V / 60A 3 Ø 415V @ 50Hz 250 ~ 375 Ah 9 - 12hrs
RC8080-T 80V / 80A 3 Ø 415V @ 50Hz 375 ~ 500 Ah 9 - 12hrs
RC80100-T 80V / 100A 3 Ø 415V @ 50Hz 500 ~ 625 Ah 9 - 12hrs
RC80120-T 80V / 120A 3 Ø 415V @ 50Hz 625 ~ 750 Ah 9 - 12hrs
RC80140-T 80V / 140A 3 Ø 415V @ 50Hz 750 ~ 875 Ah 9 - 12hrs
RC80160-T 80V / 160A 3 Ø 415V @ 50Hz 875 ~ 1000 Ah 9 - 12hrs
note: other capacity is available upon request.

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
gc series golf car
battery charger

GC series golf car battery charger is a portable lead


acid charger designed specially for golf car deep-cycle batteries
charging. This charger allows you to operate without worrying
whether the battery is fully charged or not thanks to the fully
automated charging system incorporated within the charger. The
input cable comes with a 3 pin 13A plug top that can be connected
to any wall mounted 13A sockets and the output cable comes with
a battery connector.

Electronic monitoring of charging condition monitors the actual


condition during charging and is indicated through bright L.E.Ds
located on the front panel. It is very economical, simple to operate
and superb reliability which battery chargers will
always emphasize on.

features
rated supply voltage 240V 50Hz
battery type lead acid battery
charging voltage 24Vdc, 36Vdc and 48Vdc
charging current 17A max
charging type fully automatic charging
Front View
LED indicators charger on, charging, 50% charged,
80% charged and fully charged
safety feature MCB over current protection
cubical construction aluminium casing
D

technical specification
model charging charging dimension (mm)
voltage (Vdc) rate (h x w x d)
GC 2417 24V 17A 310 x 210 x 290
GC 3617 36V 17A 310 x 210 x 290
GC 4817 48V 17A 310 x 210 x 290

Side View

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
sealed lead acid
battery charger series

SLA series battery charger is a portable charger designed specially for charging
sealed lead acid battery. Incorporated with a fully automated charging system and the actual charging
condition is indicated through the ammeter located on the front panel. It is very economical, simple
to operate and superb reliability.

features
input rated voltage 220Vac ~ 240Vac 1Φ 50Hz
battery type sealed lead acid battery / lead acid battery
charging voltage 12Vdc / 24Vdc
charging current 5A, 10A and 15A
charging type fully automatic charging

technical specification
model SLA SLA SLA SLA SLA SLA
1205 1210 1215 2405 2410 2415
battery voltage 12V 12V 12V 24V 24V 24V
charging rate 5A 10A 15A 5A 10A 15A

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
STANDBY AUTOMATIC
battery charger SERIES

Standby Automatic Battery Charger series is use in


the switchboard for charging generator battery. Battery condition
is automatically maintained to full charge by the charger at all times
and ready for starting the generator when required.

Standby Automatic Battery Charger is also applicable for charging


battery for standby use only.

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
ss & ES series standby
automatic battery charger

features
· electronic current limiting
· incorporated with rectifier
fail relay
· boost charging facility
· auxiliary trickle charging
facility
· nickel cadmium / lead acid
battery selection
SS-Series ES-Series
· maximum charging current is
limited to 5A, 10A, 15A and
technical specification
20A respectively
model SS-Series supply output charging fuse dimension (mm) weight
· metal base plate fabricated voltage voltage current (A) rating (A) (h x w x d) (kg)
from heavy gauge steel with
SABC-SS-1205 240Vac DC 12V 5A 7.5A 115 x 245 x 310 4.5
epoxy finishing
SABC-SS-1210 240Vac DC 12V 10A 15A 115 x 245 x 310 5.5
· designed for vertical
SABC-SS-1215 240Vac DC 12V 15A 20A 145 x 245 x 310 7.0
mounting to obtain good
SABC-SS-1220 240Vac DC 12V 20A 32A 165 x 245 x 360 9.5
conventional cooling
SABC-SS-2405 240Vac DC 24V 5A 7.5A 115 x 245 x 310 5.5
· suitable for standby
SABC-SS-2410 240Vac DC 24V 10A 15A 165 x 245 x 310 9.0
generator set battery
SABC-SS-2415 240Vac DC 24V 15A 20A 180 x 245 x 360 10.0
charging
SABC-SS-2420 240Vac DC 24V 20A 32A 185 x 245 x 360 13.0
SABC-SS-4805 240Vac DC 48V 5A 10A 165 x 245 x 310 9.0
rated supply voltage
SABC-SS-4810 240Vac DC 48V 10A 16A 180 x 245 x 360 13.0
· 240V +/- 10% 50Hz

model ES-Series supply output charging fuse dimension (mm) weight


boost charge voltage for voltage voltage current (A) rating (A) (h x w x d) (kg)
12/24v batteries SABC-ES-1205 240Vac DC 12V 5A 7.5A 145 x 210 x 210 3.7
· nickel cadmium battery SABC-ES-1210 240Vac DC 12V 10A 15A 145 x 210 x 210 4.9
- 15 –15.5Vdc / 30 – 31Vdc SABC-ES-2405 240Vac DC 24V 5A 7.5A 145 x 210 x 210 4.9
· lead acid battery SABC-ES-2410 240Vac DC 24V 10A 15A 145 x 210 x 210 7.6
- 14.5 –15Vdc / 29 – 30Vdc
circuit diagram (SS-Series / ES-Series) dimension (ES-Series)
float charge voltage for
BDG 1
12/24v batteries BDG R1
1 R1 G G

· nickel cadmium battery CURRENT


LIMIT
CURRENT
LIMIT
VOLTAGE
QPS

RELAY VOLTAGE
CUT - OUT
H
- 14.25Vdc / 28.5Vdc RELAY K
CUT - OUT
TRIGGER
I

· lead acid battery K J


SCR 1
TRIGGER F
I
W
- 13.75Vdc / 27.5Vdc A B J C D1
MAINS CURRENT

R2
H
SCR 1
TRICKLE CURRENT F
MAINS CURRENT

A B C D1 R2
H

TRICKLE CURRENT

dimension (SS-Series) D

QPS
H

W D

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
Cs & VS series standby
automatic battery charger

features
· electronic current limiting
· incorporated with rectifier
fail relay
· boost charging facility
· auxiliary trickle charging
facility
· nickel cadmium / lead acid
battery selection
· maximum charging current
is limited to 5A and 10A
respectively CS-Series VS-Series
· metal bracket fabricated
from heavy gauge steel with technical specification
epoxy finishing model CS-Series supply output charging fuse dimension (mm) weight
· designed for vertical voltage voltage current (A) rating (A) (h x w x d) (kg)

mounting to obtain good SABC-CS-1205 240Vac DC 12V 5A 7.5A 170 x 140 x 135 5.3
conventional cooling SABC-CS-1210 240Vac DC 12V 10A 15A 170 x 140 x 135 5.8
· suitable for standby SABC-CS-2405 240Vac DC 24V 5A 7.5A 170 x 140 x 135 5.8
generator set battery SABC-CS-2410 240Vac DC 24V 10A 15A 215 x 140 x 135 8.6
charging
model VS-Series supply output charging fuse dimension (mm) weight
voltage voltage current (A) rating (A) (h x w x d) (kg)
rated supply voltage
· 240V +/- 10% 50Hz SABC-VS-1205 240Vac DC 12V 5A 10A 138 x 98 x 103 3.0
SABC-VS-2405 240Vac DC 24V 5A 10A 138 x 98 x 120 4.0
boost charge voltage for
12/24v batteries circuit diagram dimension (CS-Series)
· nickel cadmium battery
BDG 1
- 15 – 15.5Vdc / 30 – 31Vdc R1
G
W D
· lead acid battery CURRENT
LIMIT
- 14.5 – 15Vdc / 29 – 30Vdc VOLTAGE
CUT - OUT W
RELAY
H
K SCR1
float charge voltage for I
TRIGGER

12/24v batteries J
SCR 1 SCR2
F
· nickel cadmium battery MAINS CURRENT
TRIGGER H
D1 D2 VOLTAGE
- 14.25Vdc / 28.5Vdc A B C D1 R2
RELAY
H
CURRENT
CUT - OUT
QPS
LIMIT
· lead acid battery CS-Series
TRICKLE CURRENT

- 13.75Vdc / 27.5Vdc AC 240V E R1 dimension (VS-Series)


SCR1
W

SCR2
SCR1
TRIGGER
D1 D2 VOLTAGE
SCR2
CUT - OUT
RELAY TRIGGER CURRENT H
D1 D2 LIMIT
VOLTAGE
CUT - OUT
RELAY CURRENT QPS
LIMIT
AC 240V E R1
D
VS-Series
AC 240V E R1

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
BATTERY BANK

features
· 12V battery for vehicles
maintenance
· maintenance-free battery /
auto charger
· plugs directly into a 12V car
cigarette lighter
· rugged metal construction

design features
· robust
· easy to operate In a modern day vehicle, more and more equipment is being
· light and portable installed. The data in the storage functions of the electronic devices is
maintained by the vehicle’s 12V battery. Data is lost when the battery
is disconnected. In order to maintain the data, a backup battery bank
is needed before disconnecting the battery. 12Vdc
battery bank is specially designed to solve this problem.

technical specification
model 12Vdc battery bank
supply voltage 240Vac
output voltage 12Vdc
frequency 50 / 60 Hz
safety features fast blow glass fuse
enclosures finishing epoxy powder coated
dimensions (h x w x d) (175 x 110 x 250) mm
weight 5.0kg

dimension

110 250

175

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
BATTERY tester

BT 101 BT 202 DC-12

6V & 12V battery tester is designed for fast and accurate 180
monitoring of battery condition. It is equipped with multiple test function
such as battery load test, motor cranking test and charging system test.
300
Robust design, light weight and large display are some of the special
features that provide user the flexibility of movement and fast judgement
when carrying out test. Heavy duty insulated battery clamps are selected
85
to ensure safe and proper application.
BT 101
features
battery rating 6V and 12V batteries
checking parameters battery load test
motor cranking test 261
charging system test
safety features reverse polarity protection
automatic overload cut-off 130 150
overload alarm (optional)
DC-12
battery load test duration 10 seconds (maximum)
terminal clips 200Amps high quality clips

technical specification 270

model BT 101 DC-12 BT 202


battery capacity selection √ √
temperature selection √ 247 167

automatic overload cut-off √ √ BT 202


battery rating (V) 6 – 12 12 12
motor cranking test √ √ √
dimensions (h x w x d) 300 x 180 x 85 261 x 130 x 150 270 x 247 x 167
weight (kg) 2.0 3.5 4.0

Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
accreditations & certifications

ISO9001: UKAS ISO9001: Standard Malaysia CE marking for


Control Transformer

CE marking for On-Site Witness DNV certificate


Isolating Transformers for DHCFR

ISO 9001:2015 Quality Management System certified by Bureau Veritas


PSB TUV SUD Test Certificate for K-factor transformer
PSB TUV SUD Test Certificate for Detuned Harmonic Circuit Filter Reactor
Compliance to Low Voltage Directive (LVD) according to IEC60076
ABS (American Bureau of Shipping)
RMRS (Russian Maritime Register of Shipping)
LR (Lloyd’s Registrar)
DNV (Det Norske Veritas)
BV (Bureau Veritas)
NKK (Nippon Kaiji Kyokai)
GL (German Lloyd)
www.success.com.my

Success Electronics & Transformer Manufacturer Sdn Bhd [200853-K]


(A wholly owned subsidiary of Success Transformer Corporation Berhad)

No. 3, 5 & 7 Jln TSB 8, Taman Industri Sungai Buloh, 47000 Sungai Buloh, Selangor Darul Ehsan, West Malaysia.
T: 1300 88 2788 (National Toll Free) / +603 - 6279 2800
F: +603 - 6157 2722 / 2723 E: ses@success.com.my

Sales Enquiry
Domestic: marketing@success.com.my
Overseas: export@success.com.my

You might also like