QPS Catalogue
QPS Catalogue
Responding to a
Changing World
Success is a transformer and lighting manufacturing company incorporated in Malaysia since 1980 wholly-owned by Success
Transformer Corporation Berhad (STC), a public listed company in the Main Board of Bursa Malaysia. We have been the
foremost provider of lighting and power distribution technologies, enabling new and more efficient uses of energy in
industrial areas that can transform our world both visually and practically.
“With our capabilities, we Our Complete Solutions Workflow begin from conception all the way to
final installation on site. We have amassed the necessary software, and
are able to manufacture from
hardware and expertise. Success is an Original Design Manufacturer (ODM)
ground up, to match as close where we design and manufacture products for customers under their
to perfection as possible to own brands, and an Original Equipment Manufacturer (OEM) where we
your compliance, performance manufacture products for customers according to their designs. We can
create any design, in almost any situation, and we will present a visual
and output, sustainability &
rendering of the design or design area to the customer as part of our pre-
consumption specifications.” sales service to visualize your ideas.
We are using the most advanced production technologies and the most
demanding control systems to guarantee the highest quality and total
product reliability. Considerable investments have been made to upgrade
equipment, quality certification and laboratory testing facilities, in
particular for our low voltage transformer and LED lighting sectors.
certifications
CE
capacity
introduction
· single phase
QPS Power Transformer is suitable for any industrial, commercial, manufacturing and production process
50VA ~ 100KVA
· three phase application. Power Transformer can be offered for a variety of environment conditions, for instance K factor
50VA ~ 2000KVA transformer, UPS transformer, and marine transformer. QPS transformer is safe, reliable and durable. Not
only do we produce top quality transformers but we also custom build transformers according to customers’
winding material design and specifications. With the continuous development in all phases of the design and manufacturing
· copper or aluminium
processes, we now offer dry-type transformers up to 2000KVA (2MVA).
· polyester enamelled wire
155°C (Class F) &
180°C (Class H) enclosures
· Fiberglass wire Enclosures for QPS transformers are manufactured from cold-rolled steel sheet and finished with epoxy
180°C (Class H) powder coat. Different Ingress Protection (IP) categories could be supplied upon request, which is up to IP44.
Enclosures can also be manufactured to meet customers’ special requirements.
silicon steel
· good quality, non grained
type testing
oriented and low loss
grained oriented Upon request, the following type test can be carried out at extra costs.
silicon steel · temperature rise test
Certifications by testing body are available upon request.
varnish
· high grade high temperature
accessories
polyester varnish
Optional accessories may be requested at an additional cost:
Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
power transformer
k-factor transformer
The use of electronic equipment is growing rapidly in both the commercial and industrial sectors. These
electronic devices are powered by either switching power supplies or a rectifier circuit. Some examples of
these devices include UPS, computers, fax machines and printers. There are contributing to the distortion of
the current waveform and the generation of harmonics. Harmonics are defined as currents created by non-
linear loads, which generate non-linear current waveforms. Some of the examples in which the harmonics
presence include apparatus vibration, overheating of electrical equipment and electronic devices
malfunction.
K-Factor transformer is designed to withstand the harmonic distortion associated with these loads. It is
suitable for building security and as a bypass transformer for UPS systems, computers and peripherals,
telecommunication, laboratory instrumentation and office automation.
marine transformer
QPS marine transformer is safe and durable, which is produced for ships or vessels. The transformer is
manufactured in compliance with independent Marine Vessel requirements to maximize safety. The
transformer is naturally air-cooled mounted in IP rated metal enclosures. FAT by independent body could be
arranged upon customer’s request, at an extra cost.
Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
motor starting auto transf0rmer
capacity
· single tapping @ 70%
· three tapping @ 50%, 60%
and 75%
cooling
· natural air cool
safety
· thermostat protected for
transformer above 11KW
termination of wires
· high quality nylon
terminal block
· chrome steel metal
bolts & nuts
re-start frequencies
· maximum re-start
frequencies of
4 times per hour at
appropriate intervals
insulation class
· class F
optional
· customize designs are
available upon request
dimension
D W
D W
H H
Y
X Y
Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
motor starting auto transf0rmer
capacity hp thermostat no. of tapping mounting pitch (mm) overall dimension (mm) weight
(kw) tapping percentage x y w d h (kg)
3.75 5.0 nil/1 single 70% 120 185 215 195 90 5.5
5.5 7.5 nil/1 single 70% 120 185 215 195 95 6.5
7.5 10 nil/1 single 70% 120 185 215 195 100 7.0
11 15 nil/1 single 70% 140 210 240 215 100 9.5
11 15 1 three 50% 60% 75% 140 210 240 225 140 9.6
15 20 1 three 50% 60% 75% 140 210 240 225 155 11.5
22 30 1 three 50% 60% 75% 155 240 270 245 155 15.0
30 40 1 three 50% 60% 75% 155 240 270 245 160 16.5
37.5 50 1 three 50% 60% 75% 155 240 270 245 170 19.0
45 60 1 three 50% 60% 75% 185 270 300 275 170 20.5
56 75 1 three 50% 60% 75% 185 270 300 275 180 25.5
66 88 1 three 50% 60% 75% 185 270 300 275 210 34.0
80 107 1 three 50% 60% 75% 210 305 340 300 205 36.0
94 125 1 three 50% 60% 75% 210 305 340 300 215 41.0
110 150 1 three 50% 60% 75% 220 305 340 310 245 56.0
132 175 1 three 50% 60% 75% 220 305 340 310 255 61.0
150 200 3 three 50% 60% 75% 210 170 360 370 390 91.0
180 240 3 three 50% 60% 75% 260 170 410 380 400 105.0
225 300
3 three 50% 60% 75% 260 190 410 400 400 120.0
capacity hp thermostat no. of tapping mounting pitch (mm) overall dimension (mm) weight
(kw) tapping percentage x y w d h (kg)
3.75 5.0 nil/1 single 70% 120 185 215 195 90 6.1
5.5 7.5 nil/1 single 70% 120 185 215 195 95 7.5
7.5 10.0 nil/1 single 70% 120 185 215 195 100 8.6
11 (S) 15 nil/1 single 70% 140 210 240 215 100 10.7
11 3T 15 1 three 50% 60% 75% 140 210 240 225 145 12.4
15 20 1 three 50% 60% 75% 140 210 240 225 155 13.9
22 30 1 three 50% 60% 75% 155 240 270 245 150 17.3
30 40 1 three 50% 60% 75% 155 240 270 245 155 19.3
37.5 50 1 three 50% 60% 75% 155 240 270 245 155 21.1
45 60 1 three 50% 60% 75% 185 270 300 275 160 24.0
56 75 1 three 50% 60% 75% 185 270 300 275 180 30.3
66 88 1 three 50% 60% 75% 185 270 300 275 190 35.1
80 107 1 three 50% 60% 75% 210 305 340 300 210 42.3
94 125 1 three 50% 60% 75% 210 305 340 300 215 48.3
110 150 1 three 50% 60% 75% 220 305 340 310 235 62.5
132 175 1 three 50% 60% 75% 220 305 340 310 245 68.8
150 200 3 three 50% 60% 75% 210 170 360 370 390 100
180 240 3 three 50% 60% 75% 210 180 360 380 390 115
225 300
3 three 50% 60% 75% 210 190 360 390 390 130
Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
VARIABLE VOLTAGE transf0rmer
technical data
Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
VARIABLE VOLTAGE transf0rmer
dimension
W
W
W
H
D H D
H D
technical specification
Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
DETUNED HARMONIC
CIRCUIT FILTER REACTOR
technical data
rated voltage
· 3 x 525V 50Hz &
440V 50Hz
frequency of filter
· 189Hz
diagram
· ±5% A A
B B
linearity of inductance C C
· 1.3 x In
· 2.5kV
degree of protection
· IP 00
winding material
· copper or aluminium
· polyester enamelled wire
introduction
155°C (Class F) &
Power disturbance and harmonic distortion in electrical systems have proven to be fatal to equipment,
180°C (Class H)
cables, transformers, capacitor banks etc. The situation has deteriorated further with the use of products
· fibreglass wire 180°C
such as variable speed drives, soft starters, rectifiers, UPS, discharge lamp etc. These devices will generate or
(Class H)
increase the harmonic distortion and high frequency interference in the power system. These disturbances
will cause overheating to cables, transformer and related equipment etc.
reactor core
· 0.5mm high grade silicon steel
Detuned Harmonic Circuit Filter Reactor is used for:
·
from Japan & Korea
filtering harmonics and high frequency disturbance
varnish · reduce high inrush current (from parallel switching of capacitors & from power to capacitor banks
and thus improves the operating source life span of the capacitor)
· high grade high temperature
polyester varnish
Filtering % p is the ratio of inductance to capacitance. It is not to be confused with the impedance or
reactance of an inductor.
insulation class
For a 50Hz system:
·
· class F or H
p=7% = 189Hz is used where protection to capacitor and harmonics reduction is required
· p=6% = 204Hz is to be used where the system is rich in 5th harmonics and above
·
ambient temperature
p=13% = 139Hz is used where voltage distortion exceed permissible limit
· max 40°C
Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
DETUNED HARMONIC
CIRCUIT FILTER REACTOR
dimension
W D
W D
H
H
type A type B
model model 525V capacitor rated inductance overall dimension (mm) weight
no. type rater power (KVAr) current (A) (mH) w d h (kg)
A5K07525 A 5 5.5 12.281 175 130 170 4.5
A10K07525 A 10 11 6.141 210 130 230 8.1
A15K07525 A 15 16.5 4.094 210 145 230 10.2
A20K07525 A 20 22 3.070 210 150 230 10.4
A25K07525 B 25 27.5 2.456 270 170 230 14.6
A30K07525 B 30 33 2.047 270 175 230 15.3
A40K07525 B 40 44 1.535 270 180 230 17.8
A50K07525 B 50 55 1.228 270 190 230 19.7
A60K07525 B 60 66 1.023 270 205 230 22.8
A75K07525 B 75 82.5 0.819 320 200 280 30.5
A80K07525 B 80 88 0.768 320 200 280 30.5
A100K07525 B 100 110 0.614 320 215 280 33
A120K07525 B 120 132 0.512 320 235 280 35.8
A150K07525 B 150 165 0.409 375 270 280 50
A160K07525 B 160 176 0.384 375 270 280 52.4
A200K07525 B 200 220 0.307 410 270 320 58
A300K07525 B 300 330 0.205 435 295 320 76
Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
LINE REACTOR
rated voltage
· 3 x 415V 50Hz
% impedance
· 4%
frequency
· 50Hz
test voltage
diagram
· 2.5kV
rated current M M
· refer to table
ambient temperature
· max 40°C
Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
LINE REACTOR
dimension
W D
W D
H
H
type A type B
model model type current (A) inductance (mH) dimensions (mm) weight
w d h (kg)
3LR8 A 8 3.813 175 130 170 3.9
3LR12 A 12 2.542 210 110 220 5.8
3LR18 A 18 1.695 210 125 220 7.5
3LR28 B 28 1.089 210 150 160 8.7
3LR40 B 40 0.763 210 165 160 10.9
3LR50 B 50 0.610 240 170 210 15.0
3LR63 B 63 0.484 240 180 210 17.4
3LR80 B 80 0.381 270 180 210 19.1
3LR125 B 125 0.244 270 205 210 26.6
3LR160 B 160 0.191 300 200 260 34.7
3LR200 B 200 0.153 315 220 260 38.0
Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
v-SERIES AUTOMATIC VOLTAGE STABILIZER
technical data
input voltage
· single phase: 230V ±12%
· three phase: 415V ±12%
+ neutral
voltage fluctuation
rated kva In the real world power line voltage occurs frequently especially in industrial area. Every electrical
· single phase: 1KVA ~ 30KVA equipments and devices do have a working voltage limit/tolerance. Some equipment are build to tolerate
· three phase: 3KVA ~150KVA ±10% of nominal voltage while others ±5% or less depending on sensitivity.
QPS Servo - Motor Automatic Voltage Stabilizer provides a continuous monitoring of the output voltage
operating temperature (true RMS sensing) by means of an electronic Control Circuit that compares the instantaneous output voltage
· 0°C ~ 45°C with the set value. When changes are detected due to fluctuation of supply voltage or sudden changes in
load, an electrical signal will be transmitted to the servo – motor which is coupled onto the brush gear of the
SPD surge protection variable transformer, causes the brush gear to rotate until the appropriate voltage is restored. This method
of stabilization does not create interference or harmonic to the supply system. QPS Three phase Automatic
· 1 phase standard
Volltage Stabilizer also designed to cater for unbalanced load. This made possible with its independent
· 3 phase (optional) phase monitoring system.
phase loss sensing QPS Automatic Voltage Stabilizer offer high quality performance at competitive prices. They solve voltage
protection unstable problems and increase productivity.
· phase sensing relay (optional)
power line conditioner
automatic output delay QPS power line conditioner (PLC) is a AVS with the inclusion of a shielded isolation transformer.
on system
· time delay (optional)
Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
v-SERIES AUTOMATIC VOLTAGE STABILIZER
applications
· CNC wire-cut / EDM · Broadcasting equipment
· CNC drilling machine · Photographic processing equipment
· CNC milling machine · Photocopy machine
· X – Ray equipment · Test equipment
· Industrial robots · Computers
· Communication system · Medical equipment
· PLC equipment · LAB equipment
standard features
. over current circuit breaker
. analog voltmeter
. phase indicator lamps
. phase selector switch for voltmeter (for three phase only)
optional features
. surge protection device (SPD)
. phase loss (3 phase model) c/w programmable under / over voltage detector / phase sequence monitoring
. automatic output delay on system
. manual bypass switch
input termination
power cord c/w 13A BS 3 pin plug – (model 1KVA, 2KVA & 3KVA)
power cord c/w 15A BS 3 pin plug – (model 4KVA)
terminal block for hardwire – (model 5KVA ~ 30KVA)
output termination
13A BS 3 pin socket – (model 1KVA ~ 15KVA)
terminal block for hardwire – (model 3KVA ~ 30KVA)
diagram
Single Phase & Three Phase Servo – Motor Voltage Stabilizer Block Diagram
Legend
Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
v-SERIES SINGLE PHASE
AUTOMATIC VOLTAGE STABILIZER
dimension
D W
W W
D D
D
D D
W W H
H H
H H
H
CABINET 1
CABINET 1
CABINET 3 CABINET 4
cabinet 1 cabinet 2 cabinet 3
model cabinet power rated rated / output input voltage output accuracy dimensions (mm) (+/-) weight (kg)
output (KVA) current (A) variation (%) h w d (+/-)
VSS1 - 2 1 1 4 230V ± 12% ±1.5% 183 200 220 8
VSS2 - 2 1 2 9 230V ± 12% ±1.5% 200 230 245 10
VSS3 - 2 1 3 13 230V ± 12% ±1.5% 283 260 330 23
VSS4 - 2 1 4 17 230V ± 12% ±1.5% 283 260 330 24
VSS5 - 2 1 5 22 230V ± 12% ±1.5% 283 260 330 24
VSS7 - 2 2 7.5 33 230V ± 12% ±1.5% 370 270 560 45
VSS10 - 2 2 10 43 230V ± 12% ±1.5% 370 270 560 50
VSS15 - 2 2 15 65 230V ± 12% ±1.5% 370 270 560 53
VSS20 - 2 3 20 87 230V ± 12% ±1.5% 640 400 375 57
VSS25 - 2 3 25 109 230V ± 12% ±1.5% 640 400 375 68
VSS30 - 2 3 30 130 230V ± 12% ±1.5% 640 400 375 73
remarks: The dimensions indicated above is applicable for Automatic Voltage Stabilizer only. Please refer to the staff for power line conditioner dimensions if required.
Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
D
v-SERIES THREE PHASE
W AUTOMATIC VOLTAGE STABILIZER
dimension
D
H W
W
D
CABINET 1
cabinet 1 cabinet 2
model cabinet power rated rated / output input voltage output accuracy dimensions (mm) (+/-) weight (kg)
output (KVA) current (A) variation (%) h w d (+/-)
VST3 - 4 1 3 4 415V ± 12% ±1.5% 530 295 460 32
VST6 - 4 1 6 8 415V ± 12% ±1.5% 530 295 460 36
VST10 - 4 1 10 14 415V ± 12% ±1.5% 660 360 600 75
VST15 - 4 1 15 21 415V ± 12% ±1.5% 660 360 600 78
VST20 - 4 1 20 28 415V ± 12% ±1.5% 660 360 600 96
VST25 - 4 1 25 35 415V ± 12% ±1.5% 660 360 600 107
VST30 - 4 1 30 42 415V ± 12% ±1.5% 700 380 810 115
VST40 - 4 1 40 56 415V ± 12% ±1.5% 700 380 810 128
VST45 - 4 1 45 63 415V ± 12% ±1.5% 700 380 810 134
VST50 - 4 1 50 70 415V ± 12% ±1.5% 700 380 810 136
VST60 - 4 1 60 84 415V ± 12% ±1.5% 700 380 810 180
VST75 - 4 1 75 104 415V ± 12% ±1.5% 815 475 1070 213
VST100 - 4 1 100 139 415V ± 12% ±1.5% 815 475 1070 248
VST125 - 4 1 125 174 415V ± 12% ±1.5% 815 475 1070 270
VST150 - 4 2 150 209 415V ± 12% ±1.5% 1490 660 580 385
remarks: The dimensions indicated above is applicable for Automatic Voltage Stabilizer only. Please refer to the staff for power line conditioner dimensions if required.
Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
S-SERIES AUTOMATIC VOLTAGE STABILIZER
technical data
input voltage
· single phase: 230V ± 15%
· three phase: 415V ± 15%/10%
+ neutral
over current protection QPS Servo - Motor Automatic Voltage Stabilizer provides a continuous monitoring of the output voltage
(true RMS sensing) by means of an electronic Control Circuit that compares the instantaneous output voltage
· MCB / MCCB
with the set value. When changes are detected due to fluctuation of supply voltage or sudden changes in
load, an electrical signal will be transmitted to the servo – motor which is coupled onto the brush gear of the
SPD surge protection variable transformer, causes the brush gear to rotate until the appropriate voltage is restored. This method
· 1 phase standard of stabilization does not create interference or harmonic to the supply system. QPS Three phase Automatic
· 3 phase (optional) Volltage Stabilizers also designed to cater for unbalanced load. This made possible with its independent
phase monitoring system.
phase loss sensing
protection QPS Automatic Volltage Stabilizers offer high quality performance at competitive prices. They solve voltage
unstable problems and increase productivity.
· phase sensing relay (optional)
Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
S-SERIES AUTOMATIC VOLTAGE STABILIZER
applications
· CNC wire-cut / EDM · Broadcasting equipment
· CNC drilling machine · Photographic processing equipment
· CNC milling machine · Photocopy machine
· X – Ray equipment · Test equipment
· Industrial robots · Computers
· Communication system · Medical equipment
· PLC equipment · LAB equipment
standard features
. over current circuit breaker
. analog voltmeter
. phase indicator lamps
. phase selector switch for voltmeter
optional features
. surge protection device (SPD)
. over current protection (for model above 150KVA)
. phase loss / phase sequence monitoring (3 phase model)
. automatic output delay on system
. manual bypass switch
input termination
power cord c/w 13A BS 3 pin plug – (model 1KVA , 2KVA & 3KVA)
power cord c/w 15A BS 3 pin plug – (model 4KVA)
terminal block for hardwire – (model 5KVA ~ 30KVA)
output termination
13A BS 3 pin socket – (model 1KVA ~ 5KVA)
terminal block for hardwire – (model 5KVA ~ 30KVA)
diagram
Single Phase & Three Phase Servo – Motor Voltage Stabilizer Block Diagram
Legend
* single phase avs / avr 3-phase avs / avr independent phase control
Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ
* three phase avsfrom
/ avrthe actual product.
independent phase control
S-SERIES SINGLE PHASE
AUTOMATIC VOLTAGE STABILIZER
D W D W
dimension
W W
D D
H D W HD W
H H H H
NET 4 CABINET
CABINET35 CABINET 4 CABINET 5 CABINET 3 CA
cabinet 1 cabinet 2 cabinet 3
technical specification
model cabinet power rated rated / output input voltage output accuracy dimensions (mm) (+/-) weight (kg)
output (KVA) current (A) variation (%) h w d (+/-)
S1 − 2 1 1 4 230V ± 15% ± 1.5% 260 280 335 12
S2 − 2 1 2 9 230V ± 15% ± 1.5% 260 280 335 14
S3 − 2 1 3 13 230V ± 15% ± 1.5% 260 280 335 21
S4 − 2 1 4 17 230V ± 15% ± 1.5% 260 280 335 21.5
S5 − 2 2 5 22 230V ± 15% ± 1.5% 275 260 500 34
S7 − 2 2 7.5 33 230V ± 15% ± 1.5% 370 270 560 40
S10 − 2 2 10 43 230V ± 15% ± 1.5% 370 270 560 46.5
S15 − 2 2 15 65 230V ± 15% ± 1.5% 370 270 560 54
S20 − 2 3 20 87 230V ± 15% ± 1.5% 640 400 375 64
S25 − 2 3 25 109 230V ± 15% ± 1.5% 640 400 375 75
S30 − 2 3 30 130 230V ± 15% ± 1.5% 640 400 375 83
remarks: The dimensions indicated above is applicable for Automatic Voltage Stabilizer only. Please refer to the staff for power line conditioner dimensions if required.
Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
S-SERIES THREE PHASE
AUTOMATIC VOLTAGE STABILIZER
D
W
D
W
D
H W
W
D D
H W
H H
CABINET 1
cabinet 1 cabinet 2 cabinet 3
CABINET 1
technical specification
model cabinet power rated rated / output input voltage output accuracy dimensions (mm) (+/-) weight (kg)
output (KVA) current (A) variation (%) h w d (+/-)
T3 − 4 1 3 4 415V±15% ± 1.5% 665 320 585 45
T6 − 4 1 6 8 415V±15% ± 1.5% 665 320 585 50
T10 − 4 1 10 14 415V±15% ± 1.5% 665 320 585 75
T15 − 4 1 15 21 415V±15% ± 1.5% 665 320 585 77
T20 − 4 2 20 28 415V±15% ± 1.5% 1110 570 500 159
T30 − 4 2 30 42 415V±15% ± 1.5% 1110 570 500 165
T40 − 4 2 40 56 415V±15% ± 1.5% 1110 570 500 180
T45 − 4 2 45 63 415V±15% ± 1.5% 1110 570 500 182
T50 − 4 2 50 70 415V±15% ± 1.5% 1110 570 500 190
T60 − 4 2 60 83 415V±15% ± 1.5% 1110 570 500 211
T75 − 4 2 75 104 415V±15% ± 1.5% 1110 570 500 225
T100 − 4 2 100 139 415V±15% ± 1.5% 1275 660 580 300
T125 − 4 2 125 174 415V±15% ± 1.5% 1275 660 580 345
T150 − 4 2 150 209 415V±15% ± 1.5% 1490 660 580 385
T200 − 4 2 200 278 415V±10% ± 1.5% 1490 660 580 380
T250 − 4 3 250 348 415V±10% ± 1.5% 1740 1400 800 550
T300 − 4 3 300 417 415V±10% ± 1.5% 1740 1400 800 732
T400 − 4 3 400 556 415V±10% ± 1.5% 1740 1400 800 986
T500 − 4 3 500 695 415V±10% ± 1.5% 1740 1400 800 1100
T600 − 4 3 600 835 415V±10% ± 1.5% 1955 1600 1400 1200
T700 − 4 3 700 974 415V±10% ± 1.5% 1955 1600 1400 1700
T1000 − 4 3 1000 1391 415V±10% ± 1.5% 1955 1600 1400 2000
remarks: The dimensions indicated above is applicable for Automatic Voltage Stabilizer only. Please refer to the staff for power line conditioner dimensions if required.
Note: All specifications are subject to change without prior notice for product improvement. Quality products & Services
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
CURRENT TRANSFORMER
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
CURRENT TRANSFORMER
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
RING TYPE - PVC TAPE SERIES
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
Casing type - mbq series
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
Casing type - msq series
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
AUTOMoTIve lead acid
battery charger series
introduction
Lead Acid Battery Chargers are designed to cater for high volume battery charging
up to 9 pieces of 12V battery or 18 pieces of 6V battery connected in series. This is made possible
with the use of multiple voltage and current selections to provide various combinations of charging
conditions to suit individual requirement.
They are supplied in heavy gauge steel casing complete with epoxy powder coated finishing and
come in two different designs of fixed and multiple voltage/current selections.
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
AUTOMoTIve lead acid
battery charger series
technical specification
input voltage 220Vac - 240Vac 1 phase 50Hz
(for all models)
300
OUTPUT
2 3 START 24V MAINS 5 3 5 3
4
1
4
OFF
VOLTAGE SELECTOR
5
36V 12V D.C. No. of Batteries 4 x 12V or 8 x 6V 36V 12V D.C. No. of Batteries 4 x 12V or 8 x 6V
OUTPUT OUTPUT
24V 24V
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
AUTOMoTIve lead acid
battery charger series
technical specification
input voltage 220Vac - 240Vac 1 phase 50Hz
(for all models)
CURRENT ADJUSTOR
OFF MAINS
A
7 1
-
6 2
300
OUTPUT
5 3
4
VOLTAGE SELECTOR
OFF 12V
BATTERY CHARGER
24V
108V 36V
6V 48V D.C.
OUTPUT
84V 60V
72V
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
battery charger /
engine starter
introduction
. Mobile Battery Charger / Engine Starter has a range of features including variable
charge rates and powerful boost facility. It is designed for the charging battery and keeping the
vehicles on the move
. Used as slow & fast charger and booster
. Equipped with timer for fast charging and auto stop purposes
. Selectable battery voltage range control (12V & 24V)
. Input and output breaker protection
. Variable and adjustable charging current control
. Fitted with rubber wheels and handle for instant mobility
. Built-in MCB against overloads and polarity inversion
. Selectable charging current control
. Robust in design and maintenance free
. Easy to operate, reliable and economical
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
battery charger /
engine starter
technical specification
model: STM 2460 model: SMART 450
input voltage 220Vac ~ 240Vac input voltage 220Vac ~ 240Vac
1 phase 50Hz 1 phase 50Hz
cranking power 350Amp cranking power 450Amp
charging voltage 12Vdc ~ 24Vdc charging voltage 12Vdc ~ 24Vdc
charging current 1 ~ 60Amp (adjustable) charging current 1 ~ 60Amp (selectable)
output 12V start - 4.2KW output 12V start - 5.4KW
24V start - 8.4KW 24V start - 10.8KW
weight 51.5kg weight 38kg
. A mobile charger / starter designed for the garage and fleet . A mobile starter / charger designed for the garage and fleet
. Operator with modern - style metal casing . Operator with modern - style metal casing
. Used as slow & fast charger and booster . Used as slow & fast charger and booster
. Equipped with timer for fast charging and auto stop purposes . Selectable battery voltage range (12V & 24V)
. Selectable battery voltage range control (12V & 24V) . Input breaker protection
. Input and output breaker protection . Selectable charging current control
. Variable and adjustable charging current control . Fitted with rubber wheels and handle for instant mobility
. Fitted with rubber wheels and handle for instant mobility . Robust in design and maintenance free
. Build-in MCB against overloads and polarity . Easy to operate, reliable and economical
dimensions
model: STM 2460 model: SMART 450
360 280
300 280
250
820
690 490 550
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
constant current
battery charger
A fully automated constant current charger designed for charging high volume unformed
lead acid batteries. Charging current can be adjusted easily to provide the most suitable
combination of charging current accordingly.
Due to its unique design, charging of batteries having different voltages is possible by simply
connecting the batteries in series without exceeding the rated maximum DC voltage of the
charger. To increase the quantity of batteries per charge, parallel connection as groups of
batteries is allowed.
A charging timer is incorporated to provide presetting of charging time. The systems will
shutdown once the preset time is reached.
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
constant current
battery charger
dimensions
500
400
500
400
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
automatic traction
battery charger series
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
automatic traction
battery charger series
S-Series
technical specification
main supply single phase 240V (V/cell)
(1 %)
frequency 50 / 60Hz
2,6
U
DC output voltage 12V, 24V, 36V and 48V 2,4
100 2,0
DC output current 10A up to 60A
indicators power on, 80% charged, 100% charged, 50
equalizing and safety timer
I
protection input MCB and output HRC fuse 25
features
. fully automatic two steps charging
. Thyristor controlled rectification
. protected by a 13 hours security timer
. WOWa charging mode
. equalizing cycle
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
automatic traction
battery charger series
S-Series
technical specification
model type AC input battery capacity charging time
RC 1210-S 12V / 10A 1 Ø 240V @ 50Hz 50 ~ 65 Ah 9 - 12hrs
RC 1215-S 12V / 15A 1 Ø 240V @ 50Hz 65 ~ 95 Ah 9 - 12hrs
RC 1220-S 12V / 20A 1 Ø 240V @ 50Hz 95 ~125 Ah 9 - 12hrs
RC 1225-S 12V / 25A 1 Ø 240V @ 50Hz 125 ~ 155 Ah 9 - 12hrs
RC 1230-S 12V / 30A 1 Ø 240V @ 50Hz 155 ~190 Ah 9 - 12hrs
RC 1240-S 12V / 40A 1 Ø 240V @ 50Hz 190 ~ 250 Ah 9 - 12hrs
RC 1250-S 12V / 50A 1 Ø 240V @ 50Hz 250 ~ 315 Ah 9 - 12hrs
RC 1260-S 12V / 60A 1 Ø 240V @ 50Hz 315 ~ 375 Ah 9 - 12hrs
RC 2410-S 24V / 10A 1 Ø 240V @ 50Hz 50 ~ 65 Ah 9 - 12hrs
RC 2415-S 24V / 15A 1 Ø 240V @ 50Hz 65 ~ 95 Ah 9 - 12hrs
RC 2420-S 24V / 20A 1 Ø 240V @ 50Hz 95 ~ 125 Ah 9 - 12hrs
RC 2425-S 24V / 25A 1 Ø 240V @ 50Hz 125 ~ 155 Ah 9 - 12hrs
RC 2430-S 24V / 30A 1 Ø 240V @ 50Hz 155 ~ 190 Ah 9 - 12hrs
RC 2440-S 24V / 40A 1 Ø 240V @ 50Hz 190 ~ 250 Ah 9 - 12hrs
RC 2450-S 24V / 50A 1 Ø 240V @ 50Hz 250 ~ 315 Ah 9 - 12hrs
RC 2460-S 24V / 60A 1 Ø 240V @ 50Hz 315 ~ 375 Ah 9 - 12hrs
RC 3630-S 36V / 30A 1 Ø 240V @ 50Hz 155 ~ 190 Ah 9 - 12hrs
RC 3640-S 36V / 40A 1 Ø 240V @ 50Hz 190 ~ 250 Ah 9 - 12hrs
RC 3650-S 36V / 50A 1 Ø 240V @ 50Hz 250 ~ 315 Ah 9 - 12hrs
RC 3660-S 36V / 60A 1 Ø 240V @ 50Hz 315 ~ 375 Ah 9 - 12hrs
RC 4830-S 48V / 30A 1 Ø 240V @ 50Hz 155 ~ 190 Ah 9 - 12hrs
RC 4840-S 48V / 40A 1 Ø 240V @ 50Hz 190 ~ 250 Ah 9 - 12hrs
RC 4850-S 48V / 50A 1 Ø 240V @ 50Hz 250 ~ 315 Ah 9 - 12hrs
RC 4860-S 48V / 60A 1 Ø 240V @ 50Hz 315 ~ 375 Ah 9 - 12hrs
note: other capacity is available upon request.
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
automatic traction
battery charger series
T-Series
technical specification
main supply three phase 415V
(V/cell)
(1 %)
frequency 50 / 60Hz
2,6
DC output voltage 12V, 24V, 36V, 48V, 72V and 80V U
2,4
DC output current 30A up to 220A 100 2,0
I
protection input MCB and output HRC fuse
25
overload protection current limiting
HOUR 1 2 3 4 5 6 7 8 9 10 t
operating temperature 0 to 40°C
enclosure finishing mild steel coated with epoxy features
. u - charging voltage curve
. I - charging current curve
automatic traction battery charger is an evolution . t - charging time
in electrical truck battery charging. It is fully automatic, robust &
simple to operate and comes in single phase input.
features
. fully automatic two steps charging
. Thyristor controlled rectification
. protected by a 13 hours security timer
. WOWa charging mode
. equalizing cycle
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
automatic traction
battery charger series
T-Series
technical specification
model type AC input battery capacity charging time
RC 2440-T 24V / 40A 3 Ø 415V @ 50Hz 185 ~ 250 Ah 9 - 12hrs
RC 2460-T 24V / 60A 3 Ø 415V @ 50Hz 250 ~ 375 Ah 9 - 12hrs
RC 2480-T 24V / 80A 3 Ø 415V @ 50Hz 375 ~ 500 Ah 9 - 12hrs
RC 24100-T 24V / 100A 3 Ø 415V @ 50Hz 500 ~ 625 Ah 9 - 12hrs
RC 24120-T 24V / 120A 3 Ø 415V @ 50Hz 625 ~ 750 Ah 9 - 12hrs
RC 24140-T 24V / 140A 3 Ø 415V @ 50Hz 750 ~ 875 Ah 9 - 12hrs
RC 24160-T 24V / 160A 3 Ø 415V @ 50Hz 875 ~ 1000 Ah 9 - 12hrs
RC 24180-T 24V / 180A 3 Ø 415V @ 50Hz 1000 ~ 1125 Ah 9 - 12hrs
RC 3650-T 36V / 50A 3 Ø 415V @ 50Hz 180 ~ 250 Ah 9 - 12hrs
RC 3660-T 36V / 60A 3 Ø 415V @ 50Hz 250 ~ 375 Ah 9 - 12hrs
RC 3680-T 36V / 80A 3 Ø 415V @ 50Hz 375 ~ 500 Ah 9 - 12hrs
RC 36100-T 36V / 100A 3 Ø 415V @ 50Hz 500 ~ 625 Ah 9 - 12hrs
RC 36120-T 36V / 120A 3 Ø 415V @ 50Hz 625 ~ 750 Ah 9 - 12hrs
RC 36140-T 36V / 140A 3 Ø 415V @ 50Hz 750 ~ 875 Ah 9 - 12hrs
RC 36160-T 36V / 160A 3 Ø 415V @ 50Hz 875 ~ 1000 Ah 9 - 12hrs
RC 36180-T 36V / 180A 3 Ø 415V @ 50Hz 1000 ~ 1125 Ah 9 - 12hrs
RC 36200-T 36V / 200A 3 Ø 415V @ 50Hz 1125 ~ 1200 Ah 9 - 12hrs
RC 36220-T 36V / 220A 3 Ø 415V @ 50Hz 1200 ~ 1320 Ah 9 - 12hrs
RC 4840-T 48V / 40A 3 Ø 415V @ 50Hz 170 ~ 250 Ah 9 - 12hrs
RC 4860-T 48V / 60A 3 Ø 415V @ 50Hz 250 ~ 375 Ah 9 - 12hrs
RC 4880-T 48V /80A 3 Ø 415V @ 50Hz 375 ~ 500 Ah 9 - 12hrs
RC 48100-T 48V / 100A 3 Ø 415V @ 50Hz 500 ~ 625 Ah 9 - 12hrs
RC 48120-T 48V / 120A 3 Ø 415V @ 50Hz 625 ~ 750 Ah 9 - 12hrs
RC 48140-T 48V / 140A 3 Ø 415V @ 50Hz 750 ~ 875 Ah 9 - 12hrs
RC 48160-T 48V / 160A 3 Ø 415V @ 50Hz 875 ~ 1000 Ah 9 - 12hrs
RC 48180-T 48V / 180A 3 Ø 415V @ 50Hz 1000 ~ 1125 Ah 9 - 12hrs
RC 48200-T 48V / 200A 3 Ø 415V @ 50Hz 1125 ~ 1200 Ah 9 - 12hrs
RC 48220-T 48V / 220A 3 Ø 415V @ 50Hz 1200 ~ 1320 Ah 9 - 12hrs
RC7260-T 72V / 60A 3 Ø 415V @ 50Hz 250 ~ 375 Ah 9 - 12hrs
RC7280-T 72V / 80A 3 Ø 415V @ 50Hz 375 ~ 500 Ah 9 - 12hrs
RC72100-T 72V / 100A 3 Ø 415V @ 50Hz 500 ~ 625 Ah 9 - 12hrs
RC72120-T 72V / 120A 3 Ø 415V @ 50Hz 625 ~ 750 Ah 9 - 12hrs
RC72140-T 72V / 140A 3 Ø 415V @ 50Hz 750 ~ 875 Ah 9 - 12hrs
RC72160-T 72V / 160A 3 Ø 415V @ 50Hz 875 ~ 1000 Ah 9 - 12hrs
RC72180-T 72V / 180A 3 Ø 415V @ 50Hz 1000 ~ 1125 Ah 9 - 12hrs
RC72200-T 72V / 200A 3 Ø 415V @ 50Hz 1125 ~ 1200 Ah 9 - 12hrs
RC8060-T 80V / 60A 3 Ø 415V @ 50Hz 250 ~ 375 Ah 9 - 12hrs
RC8080-T 80V / 80A 3 Ø 415V @ 50Hz 375 ~ 500 Ah 9 - 12hrs
RC80100-T 80V / 100A 3 Ø 415V @ 50Hz 500 ~ 625 Ah 9 - 12hrs
RC80120-T 80V / 120A 3 Ø 415V @ 50Hz 625 ~ 750 Ah 9 - 12hrs
RC80140-T 80V / 140A 3 Ø 415V @ 50Hz 750 ~ 875 Ah 9 - 12hrs
RC80160-T 80V / 160A 3 Ø 415V @ 50Hz 875 ~ 1000 Ah 9 - 12hrs
note: other capacity is available upon request.
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
gc series golf car
battery charger
features
rated supply voltage 240V 50Hz
battery type lead acid battery
charging voltage 24Vdc, 36Vdc and 48Vdc
charging current 17A max
charging type fully automatic charging
Front View
LED indicators charger on, charging, 50% charged,
80% charged and fully charged
safety feature MCB over current protection
cubical construction aluminium casing
D
technical specification
model charging charging dimension (mm)
voltage (Vdc) rate (h x w x d)
GC 2417 24V 17A 310 x 210 x 290
GC 3617 36V 17A 310 x 210 x 290
GC 4817 48V 17A 310 x 210 x 290
Side View
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
sealed lead acid
battery charger series
SLA series battery charger is a portable charger designed specially for charging
sealed lead acid battery. Incorporated with a fully automated charging system and the actual charging
condition is indicated through the ammeter located on the front panel. It is very economical, simple
to operate and superb reliability.
features
input rated voltage 220Vac ~ 240Vac 1Φ 50Hz
battery type sealed lead acid battery / lead acid battery
charging voltage 12Vdc / 24Vdc
charging current 5A, 10A and 15A
charging type fully automatic charging
technical specification
model SLA SLA SLA SLA SLA SLA
1205 1210 1215 2405 2410 2415
battery voltage 12V 12V 12V 24V 24V 24V
charging rate 5A 10A 15A 5A 10A 15A
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
STANDBY AUTOMATIC
battery charger SERIES
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
ss & ES series standby
automatic battery charger
features
· electronic current limiting
· incorporated with rectifier
fail relay
· boost charging facility
· auxiliary trickle charging
facility
· nickel cadmium / lead acid
battery selection
SS-Series ES-Series
· maximum charging current is
limited to 5A, 10A, 15A and
technical specification
20A respectively
model SS-Series supply output charging fuse dimension (mm) weight
· metal base plate fabricated voltage voltage current (A) rating (A) (h x w x d) (kg)
from heavy gauge steel with
SABC-SS-1205 240Vac DC 12V 5A 7.5A 115 x 245 x 310 4.5
epoxy finishing
SABC-SS-1210 240Vac DC 12V 10A 15A 115 x 245 x 310 5.5
· designed for vertical
SABC-SS-1215 240Vac DC 12V 15A 20A 145 x 245 x 310 7.0
mounting to obtain good
SABC-SS-1220 240Vac DC 12V 20A 32A 165 x 245 x 360 9.5
conventional cooling
SABC-SS-2405 240Vac DC 24V 5A 7.5A 115 x 245 x 310 5.5
· suitable for standby
SABC-SS-2410 240Vac DC 24V 10A 15A 165 x 245 x 310 9.0
generator set battery
SABC-SS-2415 240Vac DC 24V 15A 20A 180 x 245 x 360 10.0
charging
SABC-SS-2420 240Vac DC 24V 20A 32A 185 x 245 x 360 13.0
SABC-SS-4805 240Vac DC 48V 5A 10A 165 x 245 x 310 9.0
rated supply voltage
SABC-SS-4810 240Vac DC 48V 10A 16A 180 x 245 x 360 13.0
· 240V +/- 10% 50Hz
RELAY VOLTAGE
CUT - OUT
H
- 14.25Vdc / 28.5Vdc RELAY K
CUT - OUT
TRIGGER
I
R2
H
SCR 1
TRICKLE CURRENT F
MAINS CURRENT
A B C D1 R2
H
TRICKLE CURRENT
dimension (SS-Series) D
QPS
H
W D
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
Cs & VS series standby
automatic battery charger
features
· electronic current limiting
· incorporated with rectifier
fail relay
· boost charging facility
· auxiliary trickle charging
facility
· nickel cadmium / lead acid
battery selection
· maximum charging current
is limited to 5A and 10A
respectively CS-Series VS-Series
· metal bracket fabricated
from heavy gauge steel with technical specification
epoxy finishing model CS-Series supply output charging fuse dimension (mm) weight
· designed for vertical voltage voltage current (A) rating (A) (h x w x d) (kg)
mounting to obtain good SABC-CS-1205 240Vac DC 12V 5A 7.5A 170 x 140 x 135 5.3
conventional cooling SABC-CS-1210 240Vac DC 12V 10A 15A 170 x 140 x 135 5.8
· suitable for standby SABC-CS-2405 240Vac DC 24V 5A 7.5A 170 x 140 x 135 5.8
generator set battery SABC-CS-2410 240Vac DC 24V 10A 15A 215 x 140 x 135 8.6
charging
model VS-Series supply output charging fuse dimension (mm) weight
voltage voltage current (A) rating (A) (h x w x d) (kg)
rated supply voltage
· 240V +/- 10% 50Hz SABC-VS-1205 240Vac DC 12V 5A 10A 138 x 98 x 103 3.0
SABC-VS-2405 240Vac DC 24V 5A 10A 138 x 98 x 120 4.0
boost charge voltage for
12/24v batteries circuit diagram dimension (CS-Series)
· nickel cadmium battery
BDG 1
- 15 – 15.5Vdc / 30 – 31Vdc R1
G
W D
· lead acid battery CURRENT
LIMIT
- 14.5 – 15Vdc / 29 – 30Vdc VOLTAGE
CUT - OUT W
RELAY
H
K SCR1
float charge voltage for I
TRIGGER
12/24v batteries J
SCR 1 SCR2
F
· nickel cadmium battery MAINS CURRENT
TRIGGER H
D1 D2 VOLTAGE
- 14.25Vdc / 28.5Vdc A B C D1 R2
RELAY
H
CURRENT
CUT - OUT
QPS
LIMIT
· lead acid battery CS-Series
TRICKLE CURRENT
SCR2
SCR1
TRIGGER
D1 D2 VOLTAGE
SCR2
CUT - OUT
RELAY TRIGGER CURRENT H
D1 D2 LIMIT
VOLTAGE
CUT - OUT
RELAY CURRENT QPS
LIMIT
AC 240V E R1
D
VS-Series
AC 240V E R1
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
BATTERY BANK
features
· 12V battery for vehicles
maintenance
· maintenance-free battery /
auto charger
· plugs directly into a 12V car
cigarette lighter
· rugged metal construction
design features
· robust
· easy to operate In a modern day vehicle, more and more equipment is being
· light and portable installed. The data in the storage functions of the electronic devices is
maintained by the vehicle’s 12V battery. Data is lost when the battery
is disconnected. In order to maintain the data, a backup battery bank
is needed before disconnecting the battery. 12Vdc
battery bank is specially designed to solve this problem.
technical specification
model 12Vdc battery bank
supply voltage 240Vac
output voltage 12Vdc
frequency 50 / 60 Hz
safety features fast blow glass fuse
enclosures finishing epoxy powder coated
dimensions (h x w x d) (175 x 110 x 250) mm
weight 5.0kg
dimension
110 250
175
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
BATTERY tester
6V & 12V battery tester is designed for fast and accurate 180
monitoring of battery condition. It is equipped with multiple test function
such as battery load test, motor cranking test and charging system test.
300
Robust design, light weight and large display are some of the special
features that provide user the flexibility of movement and fast judgement
when carrying out test. Heavy duty insulated battery clamps are selected
85
to ensure safe and proper application.
BT 101
features
battery rating 6V and 12V batteries
checking parameters battery load test
motor cranking test 261
charging system test
safety features reverse polarity protection
automatic overload cut-off 130 150
overload alarm (optional)
DC-12
battery load test duration 10 seconds (maximum)
terminal clips 200Amps high quality clips
Note: All specifications are subject to change without prior notice for product improvement.
Images, pictures, and illustrations used are for illustrative purposes only and the color printed in the brochure may differ from the actual product.
accreditations & certifications
No. 3, 5 & 7 Jln TSB 8, Taman Industri Sungai Buloh, 47000 Sungai Buloh, Selangor Darul Ehsan, West Malaysia.
T: 1300 88 2788 (National Toll Free) / +603 - 6279 2800
F: +603 - 6157 2722 / 2723 E: ses@success.com.my
Sales Enquiry
Domestic: marketing@success.com.my
Overseas: export@success.com.my