PEY at Maxi.

The document provides detailed specifications for Mitsubishi Electric ceiling concealed ducted air conditioners using R410A refrigerant, including models PEY-P18JAG, SUY-ZP18VA, and others. It includes information on cooling capacity, power input, airflow, dimensions, sound levels, and refrigerant details. Additionally, it notes the conditions for capacity ratings and SEER calculations, along with installation requirements for refrigerant pipes.

Uploaded by

Anas mumtaz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
51 views1 page

PEY at Maxi.

The document provides detailed specifications for Mitsubishi Electric ceiling concealed ducted air conditioners using R410A refrigerant, including models PEY-P18JAG, SUY-ZP18VA, and others. It includes information on cooling capacity, power input, airflow, dimensions, sound levels, and refrigerant details. Additionally, it notes the conditions for capacity ratings and SEER calculations, along with installation requirements for refrigerant pipes.

Uploaded by

Anas mumtaz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

MITSUBISHI ELECTRIC AIR CONDITIONERS

EXPANDED RATING DATA SHEET


TYPE : CEILING CONCEALED - DUCTED TYPE (R410A)- (High EER Range)

INVERTER - COOLING ONLY


INPUT REFRIGERANT
AMB. RATED INPUT NET
EAT MAXIMUM COOLING CAPACITY AIR FLOW POWER ELECTRICAL DETAILS RATED DIMENSIONS (HXWXD) PIPE SOUND LEVEL
MODEL No. TEMP. POWER SEER WEIGHT
(kW) COP DIAMETER ORIGIN
(DB)
DB/WB Total Sensible Total Sensible LOW MED. HIGH LOW MED. HIGH IU CU IU+OU IU CU IU CU IU CU GAS LIQ. IU CU
IU / CU (°C) (°C) (MBH) (MBH) (kW) (kW) (CFM) (LPS) (kW) (kW) (kW) (V-Ph-Hz) (V-Ph-Hz) (kW/kW) (kW/kW) (mm) (mm) (kg) (kg) (in) (in) (dBA) (dBA)

35 27/19 18.42 15.29 5.40 4.48 0.09 1.31 1.40

PEY-P18JAG / 46 29/19 15.35 13.97 4.50 4.10 0.09 1.66 1.75


425 510 600 200 240 285 (220-230-240)-1-50 (220-230-240)-1-50 3.50 4.10 250X900X732 550X800X285 27 32 1/2 1/4 39 51 Thailand Thailand
SUY-ZP18VA
46 24/17 14.74 12.23 4.32 3.59 0.09 1.58 1.67

52 24/17 13.63 11.32 4.00 3.32 0.09 1.78 1.87

35 27/19 30.37 25.81 8.90 7.57 0.15 1.81 1.96

PEY-P24JAG / 46 29/19 27.64 25.70 8.10 7.53 0.15 2.12 2.27


620 740 885 295 350 420 (220-230-240)-1-50 (220-230-240)-1-50 3.52 4.12 250X1100X732 880X840X330 29 47 5/8 3/8 39 54 Thailand Thailand
SUY-ZP24VA
46 24/17 24.29 20.65 7.12 6.05 0.15 1.97 2.12

52 24/17 22.47 19.10 6.59 5.60 0.15 2.11 2.26

35 27/19 33.10 31.11 9.70 9.12 0.23 2.03 2.26

PEY-P30JAG / 46 29/19 29.34 28.76 8.60 8.43 0.23 2.82 3.05


850 1025 1200 400 485 567 (220-230-240)-1-50 (220-230-240)-1-50 3.50 4.09 250X1400X732 880X840X330 38 50 5/8 3/8 42 54 Thailand Thailand
SUY-ZP30VA
46 24/17 26.48 24.89 7.76 7.29 0.23 2.71 2.94

52 24/17 24.49 23.02 7.18 6.75 0.23 2.92 3.15

35 27/19 36.51 34.32 10.70 10.06 0.34 2.12 2.46

PEY-P36JAG / 46 29/19 30.37 29.76 8.90 8.72 0.34 2.79 3.13


1040 1255 1485 490 590 700 (220-230-240)-1-50 (220-230-240)-1-50 3.50 4.09 250X1400X732 880X840X330 39 51 5/8 3/8 44 54 Thailand Thailand
SUY-ZP36VA
46 24/17 29.21 27.45 8.56 8.05 0.34 2.76 3.10

52 24/17 27.02 25.40 7.92 7.44 0.34 3.06 3.40

35 27/19 51.18 42.99 15.00 12.60 0.34 2.69 3.03

PEY-P45JAG/ 46 29/19 38.90 35.79 11.40 10.49 0.34 3.81 4.15


1040 1255 1485 490 590 700 (220-230-240)-1-50 (220-230-240)-1-50 3.50 4.10 250X1400X732 1338X1050X330 39 94 5/8 3/8 44 55 Thailand Thailand
PUY-ZP45YKA
46 24/17 41.97 35.25 12.30 10.33 0.34 3.72 4.06

52 24/17 39.41 33.10 11.55 9.70 0.34 4.08 4.42

35 27/19 60.05 52.24 17.60 15.31 0.49 2.97 3.46

PEY-P60GAG / 46 29/19 46.40 43.62 13.60 12.78 0.49 4.32 4.81


1695 - 2120 800 - 1000 (220-230-240)-1-50 (220-230-240)-1-50 3.50 4.10 400X1400X634 1338X1050X330 63 102 5/8 3/8 45 55 Thailand Thailand
PUY-ZP60YKA
46 24/17 49.24 42.84 14.43 12.56 0.49 4.14 4.63

52 24/17 46.30 40.28 13.57 11.81 0.49 4.57 5.06

Notes: PEY/GPL/Aug 2019

1*Capacity mentioned above the temp. condition of Ambient 46 °C DB and EAT 29/19 °C DB/WB based on ESMA.

2* SEER based on ISO 16358-1. 2013

2* Refrigerant suction & discharge pipes to be insulated separately of min. 3/8" thickness each.

3* Amb. Temp. : Ambient Temperature, EAT: Entering Air Temperature, DB: Dry Bulb, WB: Wet Bulb, IU: Indoor unit, CU: Outdoor unit, HXWXD: Height X Width X Depth

4* External Static Pressure (ESP) = 35, 50, 70, 100, 125 Pa (PEY-P **JAG), 50/100/150Pa (PEY-P**GAG)

6* Controller : Wired LCD Remote