VarioTrack
VT-80
Model                                                                                                       VT-80
Electrical characteristics PV array side
At nominal battery voltage                                            12 V                                  24 V                                     48 V
Maximum solar power recommended (@STC)                               1250 W                                2500 W                                   5000 W
Maximum solar open circuit voltage                                    80 V                                                      150 V
Maximum solar functional circuit voltage                              75 V                                                      145 V
Minimum solar functional circuit voltage                                                           Above battery voltage
Electrical characteristics battery side
Maximum output current                                                                                    80 A
Nominal battery voltages                                                                  Automatic / manual set to 12, 24 or 48 V
Operating voltage range                                                                                  7 - 68 V
Performances of the device
Power conversion efficiency (in a 48 V typical-system)                                                       > 99 %
Maximum stand-by self-consumption (48 V)                                                                 25 mA > 1.2 W
Maximum stand-by self-consumption (24 V)                                                                 30 mA > 0.8 W
Maximum stand-by self-consumption (12 V)                                                                 35 mA > 0.5 W
Charging stages                                                                       4 stages: Bulk, Absorption, Float, Equalization
Battery temperature compensation (available with accessory BTS-01)            –3 mV /°C / cell (25°C ref) default value adjustable -8 to 0 mV /°C
Electronic protections
PV reverse polarity                                                                                     Up to –150 V
Battery reverse polarity                                                                                Up to –150 V
Battery overvoltage                                                                                      Up to 150 V
Over temperature                                                                                          Protected
Reverse current at night                                                                             Prevented by relays
Environment
Operating ambient temperature range                                                                      –20 to 55°C
Humidity                                                                                                    100 %
Ingress protection of enclosures                                                                  IP54, IEC/EN 60529:2001
Mounting location                                                                                          indoor
General data
Warranty                                                                                                  5 years
ISO Certification                                                                                  9001:2008 / 14001:2004
Weight                                                                                                     5.5 kg
Dimensions h/w/l [mm]                                                                                  120 / 220 / 350
Parallel operation (separated PV arrays)                                                              Up to 15 devices
Max wire size                                                                                             35 mm2
Glands                                                                                                   M 20 × 1,5
Communication
Network cabling                                                                               STUDER communication BUS
Remote control & Communication                                                RCC-02/-03, Xcom-232i / Xcom-LAN / Xcom-GSM / Xcom-SMS
Menu languages                                                                             English / French / German / Spanish
Data logging                                                                  With RCC-02/03, Xcom-232i on SD card · One point every minute
Accordance to standards
CE compliant                                                                       EMC 2004/108/EC · LV 2006/95/EC · RoHS 2011/65/EU
Safety                                                                                           IEC/EN 62109–1:2010
EMC (Electro Magnetic Compatibility)                                                IEC/EN 61000–6–3:2011 · IEC/EN 61000–6–1:2005
Accessories
Remote control RCC-02 or RCC-03                                                                                l
Module Xcom-232i                                                                                               l
Communication sets Xcom-LAN / Xcom-GSM / Xcom-SMS                                                              l
Battery Status Processor BSP                                                                                   l
2 aux. contacts module ARM-02                                                                                  l
Cooling Module ECF-01                                                                                     Included
Battery temp. sensor BTS-01 (3 m)                                                                              l
Communication cable CAB-RJ45-8-2                                                                               l
Data may change without any notice