Document Number:       102NMAN0003
Revision Number:           G
                                                                     Aircraft Serial
                                                                          Number:
63354 POWELL BUTTE ROAD
BEND, OR 97701, USA
800- 547-2558
www.precsieflight.com
                  Instructions for Continued Airworthiness
                 Cirrus SR22/SR22T Built-In Oxygen System
                                STC Number SA01708SE
                                            NOTICE
 The Airworthiness Limitations Section (Section 2.6) is FAA Approved and specifies maintenance
    required under Sections 43.16 and 91.403 of the Federal Aviation Regulations, unless an
                          alternative program has been FAA Approved.
                        These documents must be kept with the aircraft records.
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF THE PRECISE FLIGHT, INC.
(PFI) COMPANY, AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO
REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE, OR SELL
ANYTHING IT MAY CONTAIN OR DESCRIBE IN ANY WAY. REPRODUCTION, DISCLOSURE,
OR USE WITHOUT SPECIFIC PRIOR WRITTEN CONSENT OF PFI IS STRICTLY PROHIBITED.
                                      FAA Approval Date: 1/31/2017                       Page 1 of 36
                                        63354 POWELL BUTTE ROAD                 Document
                                              BEND, OR 97701                                     102NMAN0003
                                                                                Number:
                                               800- 547-2558
                                             www.preciseflight.com           Revision Number:         G
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
Cirrus Design SR22/SR22T Built-In Oxygen System
REVISION HISTORY
                                                                                       Approved     Approved
Rev.            DESCRIPTION OF CHANGES                       Author          Date
                                                                                          By           Date
 -     Original Release                                       STP        9/7/2006        JNS         9/7/2006
 A     Revised document to include remote filler, and         JNS        9/27/2006       JNS        9/27/2006
       final oxygen system wire routing.                                                 FAA        10/3/2006
 B     Revised document to include the A5 constant            JNS        4/27/2007     JNS/FAA      7/23/2007
       flowmeter, the PreciseFlow® Oxygen Conserver,
       added Section 2.7.1 inspection checklist for ease
       of maintenance, updated wire schematics adding
       the remote Annunciator option, added Section
       3.0 IPC to this document for ease of
       maintenance for Cirrus Customers and Service
       Centers.
 C     Added section 2.4.7 for either ground or flight        JNS         2/8/2008         JNS       2/8/2008
       testing of the O2 Required Pressure Sensor,
       added a ground test procedure for sensor test,
       allowed the owner/pilot to perform the 50, 200,
       and 500hr inspections on the breathing
       equipment. Corrected typo on item 1, Figure 19
       for the Bottle Assembly. Added Trouble Shooting
       Flow Charts figures 5-11.
 D     Removed owner/pilot notes for 50, 200, and             JNS        3/21/2008         JNS      3/21/2008
       500hr inspections on the breathing equipment as
       required per the FAA. Corrected page
       numbering error do to formatting.
 E     Updated ICA for Cirrus Perspective Installations;   W. Ashforth    2/22/10          CRB       2/23/10
       Added new SR22T model throughout document;
       changed Hydrostatic pressure test to every 5 yrs.
       (was: 3 yrs.);
 F     Added 5 port manifold data, changed CPC O-ring       R. Norris    5/27/2011         CRB       6/22/11
       service interval to 5 years, removed A4 from IPC,
       corrected typos.
 G     Corrected typo in table 1 of section 2.7. Updated
       system wire diagram section 2.8. Added
       051A0330-2 to BOM section 3.7.3. Added               J. Noland
                                                                         02/04/2016        CRB      02/15/2016
       102N0420-2 to BOM section 3.8 fig 25. Added          R. Norris
       102N0401 (3.8.1) to section 3.8. Added renamed
       conserver X3 to all sections.
                                              Title Page Rights Apply
                                      FAA Approval Date: _1/31/2017_______                         Page 2 of 36
                                                    63354 POWELL BUTTE ROAD                             Document
                                                          BEND, OR 97701                                                       102NMAN0003
                                                                                                        Number:
                                                           800- 547-2558
                                                          www.preciseflight.com                    Revision Number:                     G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
TABLE OF CONTENTS
Revision History ......................................................................................................................... 2
Table of Contents ...................................................................................................................... 3
1.0 Overview.............................................................................................................................. 5
   1.1 Purpose ............................................................................................................................ 5
   1.2 ICA Revisions ................................................................................................................. 5
2.0 Instructions for Continued Airworthiness ............................................................................. 6
   2.1 Introduction ...................................................................................................................... 6
   2.2 System Description .......................................................................................................... 6
   2.3 Special Tools Required .................................................................................................... 8
   2.4 Maintenance Instructions ................................................................................................. 8
   2.4.1 Bottle Removal and Replacement ................................................................................. 8
   2.4.2 Filler Station Cleaning ................................................................................................... 9
   2.4.3 Line Cleaning ................................................................................................................ 9
          2.4.4 Functional Test ...................................................................................................... 9
          2.4.5 Oxygen System Installation.................................................................................. 10
          2.4.6 Oxygen System Bleed-Down (Purging) ............................................................... 10
          2.4.7 Oxygen Required Pressure Calibration Check..................................................... 10
          2.4.7.1 Flight Test (Method A) ...................................................................................... 11
          2.4.7.2 Ground Test (Method B) ................................................................................... 11
   2.5 Trouble Shooting Guide ................................................................................................. 13
          2.5.1 Oxygen System Fails to Operate ......................................................................... 13
          2.5.2 Oxygen System Trouble Shooting Flow Chart ..................................................... 13
          2.5.3 Additional Technical Assistance........................................................................... 17
   2.6 Airworthiness Limitations ............................................................................................... 17
   2.7 Scheduled Maintenance Intervals and Overhaul Intervals for Inspections for Continued
   Airworthiness ....................................................................................................................... 18
          2.7.1 Scheduled Maintenance Checklist ....................................................................... 19
   2.8 System Wiring Diagram ................................................................................................. 22
................................................................................................................................................ 23
3.0 Illustrated Parts Catalog .................................................................................................... 24
   3.1 Purpose .......................................................................................................................... 25
   3.2 Overview ........................................................................................................................ 25
   3.3 Breathing Stations .......................................................................................................... 25
          3.3.1 Constant Flow Breathing Equipment .................................................................... 25
          3.3.2 PreciseFlow or X3 Demand Flow Breathing Equipment ...................................... 26
   3.4 Overhead Distribution Manifold Installation .................................................................... 27
   3.5 Oxygen Low Pressure Line Installation .......................................................................... 28
   3.6 Oxygen Bottle Installation .............................................................................................. 29
   3.7 Display/Logic Assembly Installation ............................................................................... 30
   3.7.1 Display and Controller Installations - Standard Installation ......................................... 30
   3.7.2 Display and Controller Installations - Ribbon Cable ................................................... 31
   3.7.3 Display and Controller Installation – Cirrus Perspective ............................................. 32
   3.7.4 OPTIONAL – Remote Annunciator (OPTIONAL) ........................................................ 33
   3.8 Filler Port and Line Installation ....................................................................................... 34
   3.8.1 Alternate Filler Port and Line Installation..................................................................... 35
                                                           Title Page Rights Apply
                                                 FAA Approval Date: _1/31/2017_______                                               Page 3 of 36
                                     63354 POWELL BUTTE ROAD              Document
                                           BEND, OR 97701                                 102NMAN0003
                                                                          Number:
                                            800- 547-2558
                                           www.preciseflight.com       Revision Number:          G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
List of Active Pages
ORIGINAL               ADDED PAGES                      ORIGINAL                ADDED PAGES
PG    REV   PG   REV    PG    REV     PG      REV       PG    REV    PG   REV     PG   REV     PG    REV
 1     G
 2     G
 3     G
 4     G
 5     G
 6     G
 7     G
 8     G
 9     G
10     G
11     G
12     G
13     G
14     G
15     G
16     G
17     G
18     G
19     G
20     G
21     G
22     G
23     G
24     G
25     G
26     G
27     G
28     G
29     G
30     G
31     G
32     G
33     G
34     G
35     G
36     G
                                           Title Page Rights Apply
                                FAA Approval Date: _1/31/2017_______                          Page 4 of 36
                                       63354 POWELL BUTTE ROAD                Document
                                             BEND, OR 97701                                    102NMAN0003
                                                                              Number:
                                              800- 547-2558
                                            www.preciseflight.com          Revision Number:           G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
1.0 OVERVIEW
1.1 PURPOSE
The Built-In Oxygen System (“Oxygen System” or “System”), is installed to provide supplemental
oxygen for the pilot and passengers. The System consists of the following:
  1.    A 77 cu Ft. composite wrapped cylinder mounted in the aft fuselage of the aircraft
  2.    An oxygen regulator which is connected to the bottle and contains:
           a. An overpressure discharge
           b. A high pressure transducer
   3. A Remote Filler Assembly located in the aft center of the baggage compartment and contains:
           a. A service port for filling the Oxygen System
           b. A manual pressure gauge
   4. Associated plumbing and fittings
   5. A center console panel display and System actuation switch
   6. An overhead distribution manifold with low pressure transducer and integrated interior LED
        dome light
   7. Breathing devices and flowmeters with cannulas, or masks
Setting the oxygen switch to ON illuminates the display showing oxygen quantity and energizes the
System to allow oxygen to reach the overhead distribution manifold. Additionally the System
annunciates if oxygen should be used in the aircraft as well as oxygen pressure or electrical faults.
Four (4) or five (5) manually operated oxygen flowmeters or PreciseFlow or X3 Oxygen Conservers can
be connected to the oxygen distribution manifold. The flow controls are calibrated and adjustable for
altitude by the user. The following flow controls can be one of the following:
      A4 Flowmeters and Standard or Oxygen Conserving Cannulas -- Up to 18,000 Ft.
      A4 Flowmeters and Masks (Standard and Microphone) -- Up to 25,000 Ft.
      A5 Flowmeters and Standard or Oxygen Conserving Cannulas – Up to 18,000 Ft.
      A5 Flowmeters and Masks (Standard and Microphone) – Up to 25,000 Ft.
      PreciseFlow or X3 Oxygen Conserver with Dual Lumen Cannula – Up to 18,000 Ft.
      PreciseFlow or X3 Oxygen Conserver with Masks (Standard and Microphone) – Up to 25,000 Ft.
1.2 ICA REVISIONS
To ensure the maintenance of your existing aircraft, possible revisions to Section 2.0 Instructions for
Continued Airworthiness may require updating over the life of the aircraft. Per the applicable Federal
Aviation Regulations, an update process is required to properly maintain these instructions in addition
to the aircraft itself. Because of this, it is imperative to complete the registration card for the aircraft
once the System has been installed.
Revisions can be made by a service letter from Precise Flight Inc., an Airworthiness Directive as issued
by the Administrator, by single page updates, or by a complete replacement of all pages of the manual.
It must be clearly noted as to the revision level of the pages listed in the List of Active Pages. If a single
sheet(s) is replaced, replace the List of Active Pages with the new one provided, or update the list
manually and initial and date the list.
                                            Title Page Rights Apply
                                    FAA Approval Date: _1/31/2017_______                           Page 5 of 36
                                       63354 POWELL BUTTE ROAD                         Document
                                             BEND, OR 97701                                        102NMAN0003
                                                                                       Number:
                                              800- 547-2558
                                            www.preciseflight.com               Revision Number:        G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
2.0 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS
2.1 INTRODUCTION
The contents of this section provide the instructions for continued airworthiness for the Cirrus
SR22/SR22T Built-In Oxygen System. The majority of the installation does not affect the standard
airworthiness of the aircraft; only the key Oxygen System items that exist different are noted in this
section. All structure and general maintenance must be performed in accordance with existing
approved maintenance practices, the aircraft maintenance manual or other FAA Approved
document(s).
2.2 SYSTEM DESCRIPTION
                               Figure 1 - SR22/SR22T Built-In Oxygen System Overivew
                                             Title Page Rights Apply
                                    FAA Approval Date: _1/31/2017_______                             Page 6 of 36
                                      63354 POWELL BUTTE ROAD                 Document
                                            BEND, OR 97701                                    102NMAN0003
                                                                              Number:
                                             800- 547-2558
                                           www.preciseflight.com           Revision Number:         G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
The Built-In Oxygen System consists of a few simple components for supplying sufficient oxygen to the
crew and passengers of the Cirrus SR22/SR22T aircraft. These components follow:
Oxygen Bottle
   – Stores 77 cu Ft. of Oxygen at 1800 psig
Regulator Assembly
   – Converts the high bottle pressure to a usable 70 psig for cabin distribution. This is actuated
      through a latching solenoid assembly with an electrical connection to the aircraft cockpit. The
      regulator assembly allows the bottle to be filled through a separate fill port and a fill gage. The
      fill gage allows the maintenance personnel to monitor the fill operation. An overpressure burst
      disc is incorporated to dissipate excess pressure and protect the bottle. A high pressure
      transducer electrically transmits bottle pressure to the cockpit display.
Oxygen Remote Filler Station
   – Allows for easy filling of the oxygen system and incorporates a manual pressure gage for filling,
      and preflight. Located for convenient access through the baggage door on the left hand side of
      the aircraft, just above the floor on the center of the baggage compartment aft wall. An easy
      access door covers the filler port to prevent damage to the filler from shifting baggage.
Oxygen Distribution Lines and Electrical Wiring Connections
   – The oxygen distribution lines allow oxygen to safely enter the aircraft cabin. The electrical
      connections allow the bottle and oxygen cabin pressure to be transmitted to the cockpit and for
      cockpit selection of oxygen in the aircraft cabin.
Oxygen Distribution Manifold
   – Allows the crew and passengers to connect to the Oxygen System with four (4) or five (5) quick
      disconnect fittings with the capability of sealing oxygen flow to the cabin when disconnected.
Oxygen System Display and Display-Logic Controller (DLA)
   – The Oxygen System display provides control over the oxygen delivery to the aircraft cabin. This
      display supports an Annunciator to indicate when oxygen is to be used (above 12,000 Ft. PA)
      and an indication of cabin oxygen or electrical actuation fault. The cabin oxygen flashing fault
      illuminates if cabin oxygen is not – between 60 psig and 85 psig. The electrical actuation fault
      illuminates if there is an electrical short or open circuit to the latching solenoid at the regulator.
      The oxygen controller supports these functions and ensures a short duration signal to drive the
      latching solenoid.
Breathing Equipment
   – The breathing equipment can consist of either constant flow and/or demand flow regulator
       breathing stations. Both use a connection to the distribution manifold. Precise Flight A4 or A5
       constant flow devices or “Flowmeters” indicate the flow of oxygen with an integral valve to
       control the quantity of oxygen reaching the crew or passenger. The PreciseFlow or X3 demand
       flow conservers are calibrated and adjusted by the user for altitude to supply oxygen to either
       dual lumen cannulas up to 18,000ft, or dual sensing masks. The flow indicator on this flow
       device is labeled with appropriate oxygen flow for increasing aircraft altitude. The constant
       flowmeter or demand regulator is attached to the appropriate approved mask or cannula to
       deliver oxygen to the crew or passengers.
                                           Title Page Rights Apply
                                    FAA Approval Date: _1/31/2017_______                         Page 7 of 36
                                      63354 POWELL BUTTE ROAD                Document
                                            BEND, OR 97701                                   102NMAN0003
                                                                             Number:
                                             800- 547-2558
                                           www.preciseflight.com          Revision Number:           G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
2.3 SPECIAL TOOLS REQUIRED
-Plastic reservoir hand pump
-Chemical-resistant gloves
-Protective eyewear with side shields
Refer to the installation instructions, or drawings for the Precise Flight Built-In Oxygen System.
2.4 MAINTENANCE INSTRUCTIONS
CAUTION: INSTALL PROTECTIVE COVERS ON ALL OPEN LINES AND COMPONENT FITTINGS
         IMMEDIATELY AFTER THEY ARE DISCONNECTED.
Maintain aircraft structure and wiring in accordance with aircraft maintenance manual and FAA
AC43.13.
Precise Flight Inc., www.preciseflight.com, is the approved Overhaul Facility
2.4.1 BOTTLE REMOVAL AND REPLACEMENT
The Built-In Oxygen System bottle removal and replacement procedure follows:
WARNING: OXYGEN SYSTEM MUST BE BLED TO ZERO PSI BEFORE ANY MAINTENANCE.
Bleeding Procedure:
   1. Aircraft battery power ON, oxygen display panel ON.
   2. Connect Flowmeter breathing device to overhead distribution panel and turn Flowmeter to full
       flow until oxygen is purged from the System and the flashing red 200 PSI quantity LED has
       been illuminated for 10 minutes and no more oxygen is flowing through the breathing device.
   3. Oxygen panel display OFF, aircraft power OFF.
Bottle Removal Procedure:
   1. Remove aft fuselage access panel fasteners.
   2. Remove and store access panel in a safe location.
   3. Detach flexible oxygen line and cap both lines.
   4. Disconnect electrical harness.
   5. Release the two band clamp restraints.
   6. Remove bottle and regulator assembly by first moving the assembly forward and to the left.
        Remove bottle and regulator assembly aft end of the bottle first.
   7. Installation is opposite of removal – Tighten wing nuts until snug and then two more turns to
        ensure proper tension on clamp bolt.
   8. Perform a functional system check following installation (purging per next step can be
        accomplished during the functional test).
   9. Purge the oxygen system by filling the main tank to a minimum of 500psig and bleeding the
        system down between 50-100psig by following the bleeding procedure prior to filling the system
        for use.
                                           Title Page Rights Apply
                                   FAA Approval Date: _1/31/2017_______                         Page 8 of 36
                                        63354 POWELL BUTTE ROAD                  Document
                                              BEND, OR 97701                                       102NMAN0003
                                                                                 Number:
                                               800- 547-2558
                                             www.preciseflight.com           Revision Number:             G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
2.4.2 FILLER STATION CLEANING
The filler port requires cleaning periodically, and prior to filling, to keep clean of dirt, dust, and oils to
prevent fire.
2.4.3 LINE CLEANING
Line Cleaning Procedure:
    1. Preparation
           a. Obtain a suitable container for collecting fluid waste.
           b. Wear protective gloves and eyewear.
           c. Assemble a reservoir pump and drain line, see Fig 1.
    2. Flushing
           a. Fill 2 qt reservoir with 1% Alconox or Liquinox detergent solution.
                 www.alconox.com
            b. Attach reservoir pump to cabin oxygen line.
            c. Pump 2 qt Alconox or Liquinox through oxygen line.
            d. Undo pump connection and rinse pump with clear water.
            e. Fill 2 qt reservoir with clear tap water.
            f. Attach reservoir pump to cabin oxygen line.
            g. Pump 2 qt water through oxygen line.
            h. Repeat steps A through D, rinsing the pump with the next cleaning material.
            i. Pump 1 qt Methyl Alcohol through oxygen line.
            j. Pump 1 qt ASAHIKLIN AK-225 through oxygen line. www.agcchem.com
            k. Purge the line of AK-225 by passing clean dry air through the line.
            l. With the air still flowing, sniff the air exiting the drain line. The absence of odors will
               verify the line is free of AK-225.
            m. Reconnect lines and restore System to service.
2.4.4 Functional Test
The following test procedure will evaluate the Built-In Oxygen System installation in the aircraft:
    1. Check wiring and connections before applying aircraft battery power.
    2. Fill Oxygen System with aviators oxygen (see Maintenance Manual or Flight Manual
       Supplement), leave access panel open.
    3. Switch the Oxygen System ON at the oxygen control panel and verify that the Oxygen System
       quantity display indicates the same oxygen pressure shown at the aft fill port gauge.
    4. Connect Flowmeter breathing device to overhead distribution panel.
    5. Ensure oxygen flow through a breathing device.
    6. Switch the Oxygen System OFF at the oxygen control panel.
    7. Turn aircraft battery power off.
                                              Title Page Rights Apply
                                      FAA Approval Date: _1/31/2017_______                            Page 9 of 36
                                      63354 POWELL BUTTE ROAD                Document
                                            BEND, OR 97701                                   102NMAN0003
                                                                             Number:
                                             800- 547-2558
                                           www.preciseflight.com          Revision Number:          G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
2.4.5 Oxygen System Installation
Refer to Precise Flight Inc. drawing list 102N0000 Cirrus Design Built-In Oxygen System for installation
and removal of the oxygen system components.
2.4.6 Oxygen System Bleed-Down (Purging)
Use the following procedure to bleed-down the oxygen system should any of the hard lines, non-
conductive line be opened, or bottle removed and re-installed/replaced. This procedure is required to
prevent contamination, or moisture inside the system.
   1. Attach the filler line to the filler port, making sure to purge the line prior to attaching to the
      aircraft.
   2. With the System ON, and flowmeters (or open Connectors) installed in the distribution ports,
      initiate flow for 1-2min.
   3. Remove the flowmeters from the distribution port, and turn the oxygen System OFF, and fill to
      650psig.
   4. Perform leak checks as required.
   5. Turn the System ON and using flowmeters (or open connectors) installed in the distribution
      ports; bleed the system down to below 50psig (but above 0psig).
   6. Repeat steps 3-5 once. (Leak check not required on second purge)
   7. Remove the flowmeters from the distribution port, and turn the oxygen System OFF, and fill to
      1500psig.
   8. Perform Final leak check.
   9. Fill System to 1800-2000psig as required.
2.4.7 Oxygen Required Pressure Calibration Check
The Precise Flight, Inc. Fixed Oxygen System is designed with an additional safety feature to indicate
O2 is required if the system is off, or there is no pressure at the outlet, when the cabin pressure is at
12,000ft Pressure Altitude (PA). This pressure sensor is internal to the Display Logic Controller (DLA).
To ensure this safety feature is functioning properly a check of its function is required during the annual
inspection. This may be done by a flight test to altitude, or by a ground test.
Note:     The Altitude Sensor in the Oxygen System Display Logic Assembly is NOT connected
          to the aircraft static system.
Note:     Not All aircraft are equipped with a Display Logic Assembly where a test port is
          available. In these cases the flight test is the only approved method for testing the
          calibration.
                                           Title Page Rights Apply
                                   FAA Approval Date: _1/31/2017_______                        Page 10 of 36
                                      63354 POWELL BUTTE ROAD                         Document
                                            BEND, OR 97701                                          102NMAN0003
                                                                                      Number:
                                             800- 547-2558
                                            www.preciseflight.com                Revision Number:        G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
2.4.7.1 Flight Test (Method A)
Method A of checking the calibration is by flight test. This flight is intended to be done during the
maintenance release flight following the annual inspection. The procedure is to fly to 11,000ft PA (alt
setting of 29.92inHg) and during the climb to 12,500ft PA with the oxygen system OFF, note the altitude
which the O2 Required Amber light begins to flash. This should occur between 11,500ft PA and
12,500ft PA if the system is operating normally.
2.4.7.2 Ground Test (Method B)
Method B for checking the calibration is by ground test. The ground test requires the removal of pilots
side Aft Trim Panel to gain access to the Display Logic it Controller (DLA), and is recommended that
this be performed with the seats removed, and the LH (Pilots) side Aft Trim Panel must be removed.
Note:     This should be performed during the Cabin Group Inspection as part of the Annual
          inspections. In the case of a progressive Maintenance Program, this test should be
          accomplished as close to once every year, not to exceed 18months.
Use the flowing procedure for the ground test method for the DLA pressure calibration check:
   1. Remove the Pilot Seat if not already removed as part of the annual maintenance check, cabin
      group.
   2. Remove the LH Aft Trim Panel if not already removed as part of the annual maintenance check,
      cabin group to gain access to the DLA. (See Figure 2)
                            Figure 2 - Location of Oxygen System Display Logic Controler
   3. Check general condition of the wiring, and DLA.
   4. Remove the Dust Cover/Plug. (See Figure 3)
                                             Title Page Rights Apply
                                   FAA Approval Date: _1/31/2017_______                              Page 11 of 36
                                    63354 POWELL BUTTE ROAD                          Document
                                          BEND, OR 97701                                             102NMAN0003
                                                                                     Number:
                                           800- 547-2558
                                          www.preciseflight.com                   Revision Number:        G
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
Cirrus Design SR22/SR22T Built-In Oxygen System
                                   Figure 3 - Removal of the Dust Cover Plug
  5. Using a soft rubber or similar tube with an inside diameter (ID) of 7/64in, connect one end to the
     pressure sensor nipple, and the other to the static line on a Pitot-Static Test system with pump.
                                  Figure 4 - Attachment of the Static Test Hose
CAUTION: CARE MUST BE TAKEN DURING THE INSTALLATION AND REMOVAL OF THE 7/64”
         INSIDE DIAMETER TUBING TO PREVENT DAMAGE TO THE SENSOR AND/OR THE
         CONTROLLER CIRCUIT. DO NOT YANK, OR PULL EXCESSIVELY DURING THE
         REMOVAL OR DAMAGE WILL OCCUR AND THE UNIT MUST BE REPLACED.
  6. With the aircraft in a safe condition to power up the Main Bus 2, turn ON the main bus 2 with the
     oxygen system off.
  7. Cycle the system ON and OFF to ensure the system is functioning, use a breathing device to
     ensure flow is present. With the system OFF, let the oxygen ‘bleed down’ prior to removing the
     breathing device.
  8. Using the static portion of the Pitot-Static tester, increase the static altitude slowly to 11,000ft
     PA. Continue increasing the altitude and note when the display indicates “O2 required” as
     signified on the display by the flashing amber LED. Note the altitude which this occurred.
                                           Title Page Rights Apply
                                 FAA Approval Date: _1/31/2017_______                                 Page 12 of 36
                                      63354 POWELL BUTTE ROAD                      Document
                                            BEND, OR 97701                                         102NMAN0003
                                                                                   Number:
                                             800- 547-2558
                                            www.preciseflight.com               Revision Number:        G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
   9. Verify the altitude where the indication first occurred:
          a. If indication is between 11,500ft PA and 12,500ft PA, then proceed to the next step.
          b. If the indication is outside of this range, re-verify the indication. If the DLA fails a second
              time, remove the DLA and replace, or contact PFI for re-adjustment.
   10. Turn Aircraft power off.
   11. Remove the pressure tubing taking extra care not to damage the DLA pressure transducer.
   12. Re-install the dust cover/plug.
   13. Note passing test as required.
2.5 TROUBLE SHOOTING GUIDE
2.5.1 Oxygen System Fails to Operate
a. Check circuit breaker.
b. Check connector plugs for security and contact insertion.
c. Check wiring diagram against aircraft installation. See Section 2.8.
d. Check the system function per section 2.5.2.
2.5.2 Oxygen System Trouble Shooting Flow Chart
     This section is for reference when troubleshooting the PFI Fixed Oxygen System, if used, and
     parts returned, please copy steps taken for reference.
CAUTION: Pressures above 105psig on the low-pressure side will damage the low-pressure
         transducer and will require the transducer to be replaced.
                                     Figure 5 –Trouble Shooting FlowChart (6)
                                            Title Page Rights Apply
                                    FAA Approval Date: _1/31/2017_______                            Page 13 of 36
                         63354 POWELL BUTTE ROAD                          Document
                               BEND, OR 97701                                             102NMAN0003
                                                                          Number:
                                800- 547-2558
                               www.preciseflight.com                   Revision Number:        G
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
Cirrus Design SR22/SR22T Built-In Oxygen System
                        Figure 6 - Trouble Shooting Flow Chart (1)
                      Figure 7 - Trouble Shooting Flow Chart (2 & 8)
                                Title Page Rights Apply
                       FAA Approval Date: _1/31/2017_______                                Page 14 of 36
                         63354 POWELL BUTTE ROAD                        Document
                               BEND, OR 97701                                           102NMAN0003
                                                                        Number:
                                800- 547-2558
                               www.preciseflight.com                 Revision Number:        G
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
Cirrus Design SR22/SR22T Built-In Oxygen System
                        Figure 8 - Trouble Shooting Flow Chart (3)
                        Figure 9 - Trouble Shooting Flow Chart (4)
                                Title Page Rights Apply
                       FAA Approval Date: _1/31/2017_______                              Page 15 of 36
                          63354 POWELL BUTTE ROAD                        Document
                                BEND, OR 97701                                           102NMAN0003
                                                                         Number:
                                 800- 547-2558
                                www.preciseflight.com                 Revision Number:        G
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
Cirrus Design SR22/SR22T Built-In Oxygen System
                        Figure 10 - Trouble Shooting Flow Chart (5)
                      Figure 11 - Trouble Shooting Flow Chart (7 & 9)
                                 Title Page Rights Apply
                       FAA Approval Date: _1/31/2017_______                               Page 16 of 36
                                    63354 POWELL BUTTE ROAD                 Document
                                          BEND, OR 97701                                    102NMAN0003
                                                                            Number:
                                           800- 547-2558
                                         www.preciseflight.com           Revision Number:        G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
2.5.3 Additional Technical Assistance
Please call Precise Flight, Inc., www.preciseflight.com, 800-547-2558 or 541-382-8684.
2.6 AIRWORTHINESS LIMITATIONS
         This Airworthiness Limitations Section is FAA Approved and Specifies
         maintenance required under Sections 43.16 and 91.403 of the Federal Aviation
         Regulations, unless an alternative program has been FAA Approved.
None –   The operation of the Built-In Oxygen System does not impact the airworthiness limitations,
         and is not required for normal flight.
Note:    To maintain the altitude capability of the aircraft, the Scheduled Maintenance Intervals
         and Inspections must be maintained.
                                         Title Page Rights Apply
                                  FAA Approval Date: _1/31/2017_______                       Page 17 of 36
                                                 63354 POWELL BUTTE ROAD                           Document
                                                       BEND, OR 97701                                                 102NMAN0003
                                                                                                   Number:
                                                        800- 547-2558
                                                       www.preciseflight.com                  Revision Number:                  G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
2.7 SCHEDULED MAINTENANCE INTERVALS AND OVERHAUL INTERVALS FOR INSPECTIONS FOR CONTINUED
AIRWORTHINESS
For this section, the 50hr, 200hr, and 500hr are time of oxygen system in use. Annual and yearly
inspection intervals are calendar intervals. Section 2.7.1 and Table 2 provides a checklist version of
this for maintenance work.
                                       Table 1 - Scheduled Maintenance Intervals and Inspections
                                                                                        15 YEARS
                                                                                         5 YEARS
                                                                                         3 YEARS
                                                                                       ANNUALLY
                                                                           EACH 500 HOURS OF USE
                                                                           EACH 200 HOURS OF USE
                                                                            EACH 50 HOURS OF USE
      Cirrus Design SR22/SR22T
      BUILT-IN OXYGEN SYSTEM
        1.   Check flexible lines for security of connections, kinks or tube discoloration.                                
        2.   Replace oxygen cannulas and/or oxygen masks.                                                         
        3.   Replace or overhaul microphone oxygen mask.                                                              
        4.   Perform functional test per Section 2.4.3.                                                                     
             Follow Cirrus Maintenance Manual and this document for general aircraft wiring system checks
                and headliner removal. Oxygen Wiring Diagram is in the Appendix.
             Check security of oxygen bottle mounting; re-torque wing nuts to snug and two turns tight.
             If contamination is found, clean oxygen lines. See 2.4.2.
             Check security of oxygen lines, and check bonding continuity on cabin oxygen line to ensure
                resistance to aircraft ground is no more than 0.0025Ω (2.5mΩ) between any metal to metal
                connections on the System.
             Clean and check condition of the filler port and ensure filler cap or rubber pad is present.
             Confirm that “O2 REQ’D” annunciator illuminates at 12,000 Ft. ± 500 Ft. Pressure Altitude.
        5.   Replace O-Ring in CPC Connector Assembly on the breathing stations                                                     
        6.   Purge Oxygen System. See Maintenance Manual.                                                                           
             Remove and hydrostatically test the oxygen cylinders from date marked on cylinder.
             Overhaul regulator/valve assembly – replace O-Rings, verify regulator pressure setting.
             If contamination is found, clean oxygen lines. See 2.4.2.
             Inspect oxygen lines and fittings for leaks, cracks or damage. Leak check with Snoop or
                equivalent. wwww.swagelok.com.
             Replace flexible oxygen lines on breathing stations.
             Replace O-Ring in CPC connector assembly identified on the breathing stations.
             Overhaul A4 and/or A5 Constant Flowmeters.
        7.   Replace composite wrapped oxygen cylinder.                                                                                 
             Overhaul regulator/valve assembly – replace O-Rings, verify regulator pressure setting.
             Replace non-conductive low-pressure oxygen line between the regulator and the AL hard-lines.
             Inspect oxygen lines and fittings for cracks, leaks or damage. Leak check with Snoop or
                equivalent. wwww.swagelok.com.
             Purge Oxygen System.
             Replace flexible oxygen lines on breathing stations.
             Replace O-Ring in CPC connector assembly identified on the breathing stations.
             Overhaul A4, and/or A5 Constant Flowmeters and PreciseFlow or X3 Demand Conservers.
Notes:
   1. Applicable to aircraft with Solid Green (Kevlar) Oxygen Bottle (PFI P/N 026N2001-3)
   2. Applicable to aircraft with Striped Green (Carbon) Oxygen Bottle (PFI P/N 026N2003-3)
                                                        Title Page Rights Apply
                                             FAA Approval Date: _1/31/2017_______                                         Page 18 of 36
                                        63354 POWELL BUTTE ROAD                           Document
                                              BEND, OR 97701                                                        102NMAN0003
                                                                                          Number:
                                               800- 547-2558
                                             www.preciseflight.com                 Revision Number:                           G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
2.7.1 Scheduled Maintenance Checklist
For this section, the 50hr, 200hr, and 500hr are time of oxygen system in use. Annual and yearly
inspection intervals are calendar intervals.
       Aircraft
                         Aircraft Serial                                               Inspection
    Registration                               Total Time         Hobbs Time
                             Number                                                Completion Date
       Number
                                      Table 2 - Scheduled Maintainance Checklist
                                                                                                                                       15 Year
                                                                                                           Annual
                                                                                                                     3 Year
                                                                                                                              5 Year
                                                                                           200hr
                                                                                                   500hr
                                                                                   50hr
 Item
                            Inspection Criteria
                                          Breathing Station Group
  1     Check Breathing Stations
           a) Check tubing connections for security                                 •
           b) Check tubing for kinks or discoloration and general
               cleanliness
           c) Check condition of flowmeters or PreciseFlow or X3
           d) Check flow indicator on PreciseFlow or X3 for cracks,
               stickiness, general condition
           e) Check Cannulas and Masks for general condition,
               cleanliness, or discoloration
                                            Initials:______Date:_________
  2     Replace Oxygen Cannulas and Standard (Clear) Masks
           a) Replace Standard Cannula as required and mark in-                             •
               service date on new part.
           b) Replace Oxymizer Cannula as required and mark in-
               service date on new part.
           c) Replace PreciseFlow or X3 Dual Lumen Cannula as
               required and mark in-service date on new part.
           d) Replace Standard (Clear) Facemask as required and mark
               in-service date on new part.
           e) Replace Standard (Clear) PreciseFlow or X3 Facemask as
               required and mark in-service date on new part.
                                            Initials:______Date:_________
  3     Replace/Overhaul Oxygen Facemasks with Microphone (Blue)
           a) Replace or Overhaul Facemask with Microphone (Blue) as                                •
               required and mark in-service date on New or Overhauled
               part.
           b) Replace or Overhaul PreciseFlow or X3 Facemask with
               Microphone (Blue) as required and mark in-service date
               on New or Overhauled part.
                                            Initials:______Date:_________
  4     Replace O-Rings in CPC connectors on Breathing Stations.
                                            Initials:______Date:_________                                                      •
                                              Title Page Rights Apply
                                     FAA Approval Date: _1/31/2017_______                                             Page 19 of 36
                                      63354 POWELL BUTTE ROAD                  Document
                                            BEND, OR 97701                                     102NMAN0003
                                                                               Number:
                                             800- 547-2558
                                           www.preciseflight.com            Revision Number:        G
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
Cirrus Design SR22/SR22T Built-In Oxygen System
5    Replace/ Overhaul A4 and or A5 Constant Flowmeters and
     PreciseFlow or X3 Oxygen Conservers                                                             •
        a) Replace or Overhaul A4 or A5 Constant Flowmeters as
            required and mark in-service date on New or Overhauled
            part.
        b) Replace or Overhaul PreciseFlow or X3 Oxygen
            Conservers as required and mark in-service date on New
            or Overhauled part.
        c) Replace flexible oxygen lines on breathing stations, part of
            replacement or overhaul.
                                       Initials:______Date:_________
                                  Oxygen System Installation Group
6    Functional Check
        a) Perform a functional check per section 2.4.4 of this                            •
             document.
                                            Initials:______Date:_________
7    Check Wiring
        a) Using the Cirrus Maintenance Manual and this document,                          •
             check the general wiring system including the portion of
             the oxygen system behind interior panels.
        b) See section 2.8 for oxygen system wiring schematic.
                                            Initials:______Date:_________
8    Check Oxygen System
        a) Check the security and condition of the oxygen bottle                           •
             assembly in the tail of the aircraft. If contamination is
             found in oxygen lines, clean oxygen lines per section
             2.4.3. Normal checks do not require the oxygen lines to
             be opened for inspection.
        b) Re-torque nuts for bottle mounting to 8in-lbs as required
        c) Check the security of oxygen lines and verify electrical
             continuity. Must be less than 0.0025Ω (2.5mΩ) between
             any connections. IE: tube to fitting, fitting to tube.
        d) Clean and check filler port and insure filler cap is present.
                                            Initials:______Date:_________
9    Check Altitude Annunciator (Refer to Section 2.4.7)
        a) Verify that the “O2 REQ’D” indicator light on the display                       •
             and if present the “OXYGEN REQUIRED” panel mount
             illuminate if the oxygen system is in the OFF position and
             the aircraft is at 12,000ft ± 500ft Pressure Altitude.
                                            Initials:______Date:_________
           Aircraft with Solid Green (Kevlar) Oxygen Bottle (PFI P/N 026N2001-3)
10   Hydrostatic Test Oxygen Bottle
        a) Remove Oxygen Bottle Assembly and return to Precise                                       •
            Flight Inc. for Bottle Hydrostatic test and Regulator
            Overhaul.
                 a. Overhaul regulator/valve assembly – Clean
                     regulator, replace O-Rings, and verify regulator
                     pressure.
                 b. Hydrostatic test the bottle and replace as required.
        b) Cap oxygen lines to prevent contamination. If oxygen
            lines become contaminated, or contamination found, clean
            lines per Section 2.4.3 of this report.
                                            Title Page Rights Apply
                                    FAA Approval Date: _1/31/2017_______                        Page 20 of 36
                                     63354 POWELL BUTTE ROAD                 Document
                                           BEND, OR 97701                                    102NMAN0003
                                                                             Number:
                                            800- 547-2558
                                          www.preciseflight.com           Revision Number:        G
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
Cirrus Design SR22/SR22T Built-In Oxygen System
         c) Re-Install Overhauled Regulator Valve Assembly and New
            Bottle.
         d) Bleed Down (Purge) Oxygen System per Section 2.4.6.
         e) Perform a functional check per section 2.4.4 of this
            document.
                                       Initials:______Date:_________
         Aircraft with Striped Green (Carbon) Oxygen Bottle (PFI P/N 026N2003-3)
11   Hydrostatic Test Oxygen Bottle
        a) Remove Oxygen Bottle Assembly and return to Precise                                     •
            Flight Inc. for Bottle Hydrostatic test and Regulator
            Overhaul.
                 a. Overhaul regulator/valve assembly – Clean
                     regulator, replace O-Rings, and verify regulator
                     pressure.
                 b. Hydrostatic test the bottle and replace as required
        b) Cap oxygen lines to prevent contamination. If oxygen
            lines become contaminated, or contamination found, clean
            lines per Section 2.4.3 of this report.
        c) Re-Install Overhauled Regulator Valve Assembly and New
            Bottle.
        d) Bleed Down (Purge) Oxygen System per Section 2.4.6.
        e) Perform a functional check per section 2.4.4 of this
            document.
                                         Initials:______Date:_________
                                                All Aircraft
12   Replace Oxygen Bottle
        a) Remove Oxygen Bottle Assembly and return to Precise                                          •
            Flight Inc. for Bottle replacement and Regulator Overhaul.
                a. Overhaul regulator/valve assembly – Clean
                     regulator, replace O-Rings, and verify regulator
                     pressure.
        b) Cap oxygen lines to prevent contamination. If oxygen
            lines become contaminated, or contamination found, clean
            lines per Section 2.4.3 of this report.
        c) Re-Install Overhauled Regulator Valve Assembly and New
            Bottle.
        d) Bleed Down (Purge) Oxygen System per Section 2.4.6.
        e) Perform a functional check per section 2.4.4 of this
            document.
                                          Initials:______Date:_________
                                          - End of Checklist -
                                           Title Page Rights Apply
                                   FAA Approval Date: _1/31/2017_______                       Page 21 of 36
                               63354 POWELL BUTTE ROAD                        Document
                                     BEND, OR 97701                                         102NMAN0003
                                                                              Number:
                                      800- 547-2558
                                     www.preciseflight.com               Revision Number:        G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
2.8 SYSTEM WIRING DIAGRAM
                   Figure 12 – Typical System Wire Diagram (Standard Installation)
                                     Title Page Rights Apply
                            FAA Approval Date: _1/31/2017_______                             Page 22 of 36
                              63354 POWELL BUTTE ROAD                    Document
                                    BEND, OR 97701                                      102NMAN0003
                                                                         Number:
                                     800- 547-2558
                                   www.preciseflight.com             Revision Number:        G
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
Cirrus Design SR22/SR22T Built-In Oxygen System
                Figure 13 - OPTIONAL - Remote Annunciator Wire Diagram
                                    Title Page Rights Apply
                           FAA Approval Date: _1/31/2017_______                          Page 23 of 36
                                      63354 POWELL BUTTE ROAD                      Document
                                            BEND, OR 97701                                        102NMAN0003
                                                                                   Number:
                                             800- 547-2558
                                           www.preciseflight.com               Revision Number:        G
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
Cirrus Design SR22/SR22T Built-In Oxygen System
       Figure 14 - OPTIONAL - Remote Annunciator Wire diagram (Ribbon Cable Installations)
                                            Title Page Rights Apply
                                   FAA Approval Date: _1/31/2017_______                            Page 24 of 36
                                          63354 POWELL BUTTE ROAD                      Document
                                                BEND, OR 97701                                             102NMAN0003
                                                                                       Number:
                                                 800- 547-2558
                                                www.preciseflight.com              Revision Number:              G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
3.0 ILLUSTRATED PARTS CATALOG
3.1 PURPOSE
       This section is not FAA accepted or FAA Approved and is for information only to aid in the
       maintenance and ordering replacement parts for the Precise Flight Built-In Oxygen System.
3.2 OVERVIEW
See Figure 1 for system overview picture.
3.3 BREATHING STATIONS
This section lists the replacement breathing station equipment available for the Cirrus
SR22/SR22T Built-In Oxygen System.
3.3.1 Constant Flow Breathing Equipment
                                      NOTE:
       The original Precise Flight, Inc. A4 Constant Flowmeter has been replaced by the A5 Constant Flowmeter
       for replacement parts. The Masks and Cannulas are interchangeable between the Constant Flow Meters
       Only.
                                                       1
                                                                                                                     2
                                                                                                       4
                                Figure 15 - Replacement Constant Flow Breathing Equipment
    Fig.     Item    PFI Part Number*                          Nomenclature                                     Effective
 Figure 15     1     027N0003-1            A5 Flowmeter with CPC Connector                                         All
 Figure 15     2     020N0001-1            Oxymizer Cannula                                                        All
 Figure 15     3     020N0002-1            Face Mask                                                               All
 Figure 15     4     020N0005-1            Face Mask with Microphone “Blue”                                        All
* Or equivalent foreign language version.
  PFI Kit Part                            Qty.         PFI Part
                      Fig.      Item                                                    Nomenclature
    Number                                             Number
 027N0305-1             -        -          -              -        A5 Assembly with Cannula - Face Mask, CPC, Kit
                    Figure 15    1          1         027N0003-1    A5 Flowmeter with CPC Connector
                    Figure 15    2          1         020N0001-1    Oxymizer Cannula
                    Figure 15    3          1         020N0002-1    Face Mask
 027N0306-1             -        -          -                  -    A5 Assembly with Cannula – Face Mask with
                                                                    Microphone, CPC, Kit
                    Figure 15    1          1         027N0003-1    A5 Flowmeter with CPC Connector
                    Figure 15    2          1         020N0001-1    Oxymizer Cannula
                    Figure 15    4          1         020N0005-1    Face Mask with Microphone “Blue”
                                                 Title Page Rights Apply
                                       FAA Approval Date: _1/31/2017_______                                 Page 25 of 36
                                             63354 POWELL BUTTE ROAD                      Document
                                                   BEND, OR 97701                                              102NMAN0003
                                                                                          Number:
                                                    800- 547-2558
                                                   www.preciseflight.com             Revision Number:                  G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
3.3.2 PreciseFlow or X3 Demand Flow Breathing Equipment
                                           NOTE:
       The Cirrus Built-In Oxygen System requires the PreciseFlow or X3 with CPC and
       In-Line Regulator. The PFI Semi-portable oxygen systems use a different
       pressure and are not compatible with the Built-In Oxygen System.
                                                                                                                        2
                      1
                                                          3                                                            4
                                Figure 16 - Replacement PreciseFlow Demand Breathing Equipment
    Fig.     Item    PFI Part Number*                              Nomenclature                                       Effective
 Figure 16     1     027N1002-1              Conserver and Inline Regulator Assembly, CPC                                All
 Figure 16     2     020N0050-1              Conserver (Dual Lumen) Cannula                                              All
 Figure 16     3     020N0060-1              Conserver Face Mask                                                         All
 Figure 16     4     020N0070-1              Conserver Face Mask with Microphone                                         All
* Or equivalent foreign language version.
  PFI Kit Part                               Qty.         PFI Part
                      Fig.        Item                                                     Nomenclature
    Number                                                Number
 027N1101-6             -           -          -              -        Conserver with Cannula/Face Mask, Inline
                                                                       Regulator Kit
                    Figure 16       1          1         027N1002-1    Conserver and Inline Regulator Assembly, CPC
                    Figure 16       2          1         020N0050-1    Conserver (Dual Lumen) Cannula
                    Figure 16       3          1         020N0060-1    Conserver Face Mask
 027N1102-6             -           -          -              -        Conserver with Cannula/Microphone Face Mask,
                                                                       Inline Regulator, Kit
                    Figure 16       1          1         027N1002-1    Conserver, Inline Regulator Assembly, CPC
                    Figure 16       2          1         020N0050-1    Conserver (Dual Lumen) Cannula
                    Figure 16       4          1         020N0070-1    Conserver Face Mask with Microphone
                                                    Title Page Rights Apply
                                          FAA Approval Date: _1/31/2017_______                                     Page 26 of 36
                                        63354 POWELL BUTTE ROAD                       Document
                                              BEND, OR 97701                                          102NMAN0003
                                                                                      Number:
                                               800- 547-2558
                                             www.preciseflight.com                 Revision Number:        G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
3.4 OVERHEAD DISTRIBUTION MANIFOLD INSTALLATION
                         4
                              5
                                  6
                                  7
                                   8
   Cirrus Headliner requires
   modification per Precise
       Flight Inc Drawing                    1
           102N0222
                                         2
                                      Figure 17 – Overhead Distribution Manifold
   Fig.     Item   PFI Part Number                            Nomenclature                               Effective
Figure 17     1      102N0221-1          Manifold Trim Ring                                                 All
Figure 17     2       HD 07091           #4 Black Oxide Washer                                              All
Figure 17     3       HD 07090           4-40 x 3/8 Button Head Cap Screw, Black Oxide                      All
Figure 17     4        EL 03046          Copper Foil Tape, Tin Plated 4”                                    All
                   CDC 50379-002
Figure 17    5      NAS1329A3-80         Insert                                                              All
Figure 17    6       102N0232-1          4 port Manifold and Bracket Assembly                            4 port A/C
                          OR
                     102N0235-1          5 port Manifold and Bracket Assembly                            5 port A/C
Figure 17    7       MS 35335-32         #10 Ext. Star Lock Washer                                           All
Figure 17    8       AN525-10R7          10-32 x 7/16 Washer Head Machine Screw                              All
                                                 Title Page Rights Apply
                                  FAA Approval Date: _1/31/2017_______                                 Page 27 of 36
                                            63354 POWELL BUTTE ROAD                        Document
                                                  BEND, OR 97701                                           102NMAN0003
                                                                                           Number:
                                                   800- 547-2558
                                                  www.preciseflight.com                 Revision Number:        G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
3.5 OXYGEN LOW PRESSURE LINE INSTALLATION
            Part of Item 4
                                           4                                               7
            2
   1
                                           Figure 18 - Low Pressure Line Installation
   Fig.         Item     PFI Part Number                             Nomenclature                             Effective
Figure 18         1        102N0253-1          Flexible Tubing Sub-Assembly                                      All
Figure 18         2         HD 07107           Fitting, Reducing Union                                           All
Figure 18         3        102N0252-1          Aft Fuselage Low Pressure Line                                    All
Figure 18         4         HD 06057           Bulkhead Union Fitting                                            All
Figure 18         5      NAS1149F0632P         3/8ID x 5/8OD Washer                                              All
Figure 18         6        102N0251-2          Aft Cabin Low Pressure Line                                       All
Figure 18         7         HD 07094           Fitting, 3/16 Comp Union                                          All
Figure 18         8        102N0251-1          Forward Cabin Low Pressure Line                                   All
                                                   Title Page Rights Apply
                                      FAA Approval Date: _1/31/2017_______                                  Page 28 of 36
                                              63354 POWELL BUTTE ROAD                      Document
                                                    BEND, OR 97701                                             102NMAN0003
                                                                                           Number:
                                                     800- 547-2558
                                                   www.preciseflight.com                Revision Number:            G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
3.6 OXYGEN BOTTLE INSTALLATION
            10
11                    9                                                                           Attachment of Low
                                              2                                     4
                                                                                                    Pressure Line
                                    3
                                                                                                           5
                                        7          8                1
                                                                                                           6
                             Attachment of High Pressure Line
                      Contact Precise Flight or Cirrus Design for Shelf Replacement
                                                  Figure 19 - Bottle Installation
   Fig.      Item           Part Number                             Nomenclature                                   Effective
Figure 19      1           100N0020-4 w/       Bottle Assembly, 77cuft, Remote Fill, 70psig1                        4 port
                           099N0024-1 or                                                                           manifold
                            100N1020-4                                                                             A/C only
                             Regulator
Figure 19        1         100N0020-5 w/       Bottle Assembly, 77cuft, Remote Fill, SAE, 70psig1                   4 port
                           099N0025-1 or                                                                           manifold
                            100N1020-5                                                                             A/C only
                             Regulator
Figure 19        1         100N0020-4 w/       Bottle Assembly, 77cuft, Remote Fill, 70psig1                      4 or 5 port
                            099N0024-2                                                                             manifold
                             Regulator
Figure 19        1         100N0020-5 w/       Bottle Assembly, 77cuft, Remote Fill, SAE, 70psig1                 4 or 5 port
                            099N0025-2                                                                             manifold
                             Regulator
Figure 19        2          102N0006-1         Cirrus Fixed Oxygen System – Ground Strap                                All
Figure 19        3          102N0120-1         Band Clamp Assembly, 77cuft Bottle                                       All
Figure 19        4        CDC 16524-002        U-Clamp, Oxygen Bottle                                                   All
Figure 19        5        CDC 16523-001        Strap, Oxygen Bottle                                                     All
Figure 19        6         MS27039-0805        Screw, Pan Head Structural #8-32                                         All
                          NAS1149FN832P        Washer, 0.32” Thick
Figure 19        7        CDC 16522-001        Pad, Aluminum, Oxygen Bottle                                             All
Figure 19        8          MS24694S5          Screw, Counter Sunk, Structural #8-32                                    All
                            MS21083N08         Nut, #8-32
                          NAS1149FN832P        Washer, 0.32” Thick
Figure 19        9         (Part of item 3)    ¼-28 Nylock Nut                                                          All
Figure 19        10        (Part of item 3)    AN960-4R – ¼ Washer                                                      All
Figure 19        11        (Part of item 3)    AN316-4R - ¼-28 Nut                                                      All
                                                   Title Page Rights Apply
                                         FAA Approval Date: _1/31/2017_______                                   Page 29 of 36
                                               63354 POWELL BUTTE ROAD                         Document
                                                     BEND, OR 97701                                          102NMAN0003
                                                                                               Number:
                                                      800- 547-2558
                                                    www.preciseflight.com                 Revision Number:            G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
 Notes:           1 – Bottle assembly is available in NPT or SAE ports for the filler line and low pressure outlet
                      connections, and standard or high flow regulators. Verify part number prior to ordering a
                      replacement.
3.7 DISPLAY/LOGIC ASSEMBLY INSTALLATION
                                                             NOTE:
The Cirrus Built-In Oxygen System has three (3) display/controller configurations. When replacing components take
extra care to make sure the correct part is ordered or replaced per the Precise Flight, Inc. installation drawings.
3.7.1 DISPLAY AND CONTROLLER INSTALLATIONS - STANDARD INSTALLATION
                                                                          9
     1
              3
        4
    5
                         6
                                         Figure 20 - Display and Logic Assembly Installation
    Fig.     Item PFI Part Number                             Nomenclature                           Effective
 Figure 20     1      AN365-632A       6-32 Nylock Nut                                                  All
 Figure 20     2        AN960-6        #6 Flat Washer                                                   All
 Figure 20     3     AN365-1032A       10-32 Nylock Nut                                                 All
 Figure 20     4       AN960-10L       #10 Flat Washer 0.032 THK.                                       All
 Figure 20     5      AN525-10R7       10-32 x 0.4375L Washer Head Machine Screw                        All
 Figure 20     6     MS21919-DG6       #6 Adel Clamp With Cushion                                       All
 Figure 20     7      100N2020-3       Display Logic Assembly, Remote – Low Profile                     All
 Figure 20     8     MS35206-213       Screw 4-40 x ¼ PH HD                                             All
 Figure 20     9      100N2120-2       Display Assembly, Low Resolution                                 All
 Notes:    Special care must be taken when replacing the Display Logic Assembly, and/or the Display Assembly
           to make sure they are compatible with the wire harness.
                                                     Title Page Rights Apply
                                            FAA Approval Date: _1/31/2017_______                               Page 30 of 36
                                        63354 POWELL BUTTE ROAD                         Document
                                              BEND, OR 97701                                            102NMAN0003
                                                                                        Number:
                                               800- 547-2558
                                              www.preciseflight.com                  Revision Number:        G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
3.7.2 DISPLAY AND CONTROLLER INSTALLATIONS - RIBBON CABLE
                                          1                                                                       1
         2
                                                                               3
                                                                                                             4
          5                                                                      5
                             Figure 21 - Alternate Display and Logic Assembly Installations
   Fig.      Item PFI Part Number                               Nomenclature                            Effective
Figure 21      1        100N2120-1        Display Assy, Low Resolution, with Ribbon Cable                   All
Figure 21      2        100N2020-3        Display Logic Assy, Remote – Low Profile                          All
Figure 21      3        100N2020-1        Display Logic Assy, Remote – Low Profile, Slide Lock              All
Figure 21      4        102N0320-1        Spacer Plate Adapter                                              All
Figure 21      5       MS35206-213        Screw, 4-40 x ¼ PH HD                                             All
Notes:    Special care must be taken when replacing the Display Logic Assembly, and/or the Display Assembly
          to make sure they are compatible with the wire harness. If a direct part number replacement is not
          available, contact Precise Flight Inc. with part numbers for the Wire Harness, Display, and Display
          Logic Assembly. (New installations are in the Figure 20 configuration)
                                               Title Page Rights Apply
                                     FAA Approval Date: _1/31/2017_______                                Page 31 of 36
                                        63354 POWELL BUTTE ROAD                         Document
                                              BEND, OR 97701                                          102NMAN0003
                                                                                        Number:
                                               800- 547-2558
                                             www.preciseflight.com                 Revision Number:        G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
3.7.3 DISPLAY AND CONTROLLER INSTALLATION – CIRRUS PERSPECTIVE
                       Figure 22 - Display and Logic Assembly Installations – Cirrus Perspective
   Fig.      Item   PFI Part Number                            Nomenclature                               Effective
                      051A0330-1          IFS Panel Assy., 104 – Flap, Oxygen                            See Note 1
 Figure 22    1           OR
                      051A0330-2          IFS Panel Assy., 110 – Flap, Oxygen                            See Note 2
 Figure 22    2       100N2030-1          Display Logic Assembly, MFD                                        All
 Figure 22    3      MS24693BB28          6-32 x ½” 100° Black Machine Screw                                 All
 Figure 22    4        AN960-10L          #10 Flat Washer 0.32 Thk.                                          All
 Figure 22    5      AN364-1032A          10-32 Nylock Nut                                                   All
 Figure 22    6       AN525-10R7          Screw, 10-32 x 7/16 Washer HD                                      All
 Figure 22    7     NAS1712D4-19S         Clamp, Cushioned Loop                                              All
 Figure 22    8      MS35206-213          Screw, 4-40 x ¼ PN HD                                              All
Notes:       1. MODEL SR22T S/N's 0001 THRU 0441
                MODEL SR22 S/N's 3026 THRU 3914
             2. MODEL SR22T S/N's 0442 & SUBSEQUENT
                MODEL SR22 S/N's 3915 & SUBSEQUENT
             3. Special care must be taken when replacing the Display Logic Assembly, and/or the Display
                Assembly to make sure they are compatible with the wire harness. If a direct part number
                replacement is not available, contact Precise Flight Inc. with part numbers for the Wire
                Harness, Display, and Display Logic Assembly.
                                              Title Page Rights Apply
                                    FAA Approval Date: _1/31/2017_______                               Page 32 of 36
                                     63354 POWELL BUTTE ROAD               Document
                                           BEND, OR 97701                                  102NMAN0003
                                                                           Number:
                                            800- 547-2558
                                        www.preciseflight.com           Revision Number:        G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
3.7.4 OPTIONAL – REMOTE ANNUNCIATOR (OPTIONAL)
                                                6
                                                     7
                         3      4
                                       5
             2
 1
                                       Figure 23 - Remote Annuciator
   Fig.     Item   PFI Part Number                         Nomenclature                         Effective
Figure 23     1      102N0008-2      Annunciator Wire Harness                                      All
Figure 23     2     Part of Item 1   LED Lamp Holder, Black, Holder Retainer                       All
Figure 23     3     Part of Item 1   LED, Amber (EL03021)                                          All
Figure 23     4     Part of Item 1   LED Lamp Holder, Black, Nut                                   All
Figure 23     5     Part of Item 1   LED Lamp Holder, Black, Bezel                                 All
Figure 23     6     MS 35206-213     Screw, 4-40 x ¼ PN HD                                         All
Figure 23     7      010A0101-1      LED Annunciator, Driver Assembly                              All
Figure 23     8      102N0051-1      Placard, Annunciator Dash, Oxygen Required                    All
Figure 23     -      010A0101-1      Annunciator Driver Wire Harness (NOT SHOWN)                   All
                                           Title Page Rights Apply
                                 FAA Approval Date: _1/31/2017_______                       Page 33 of 36
                                           63354 POWELL BUTTE ROAD                  Document
                                                 BEND, OR 97701                                      102NMAN0003
                                                                                    Number:
                                                  800- 547-2558
                                               www.preciseflight.com             Revision Number:            G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
3.8 FILLER PORT AND LINE INSTALLATION
                    See Figure 26
                     2                                                                          16
                     3
         5
                4                                                                                   15
         6
7
                                                                            14
                                                12          13
                                      11
          8 9                 10
                                             Figure 24 - Filler Port Assembly
       Fig.     Item     PFI Part Number                          Nomenclature                               Effective
    Figure 24     1        102N0414-1      Bracket, TKS Proportioning Valve (OPTIONAL)                          All
                            MS 07084,      Screw, 10-32 x 3/8 WH, Cd Stl (AN525-10R6)
    Figure 24    2          MS 07052,      Screw, 10-32 x ½, PHP, SS (MS51958-63)                                All
                          Or MS 07060      Screw, 10-32 x 7/16, PHP, SS (MS51958-62)
    Figure 24    3          HD 07104       Receptacle, Camloc (212-12N)                                          All
    Figure 24   4          102N0412-1      Access Panel Oxygen                                                   All
    Figure 24   5          102N0415-1      Door Assembly, Oxygen Filler                                          All
    Figure 24   6          102N0411-1      Access Panel, Modification                                            All
    Figure 24   7                -         See Cirrus IPC for Access Panel Screws                                All
    Figure 24   8           MS 01513       Screw, 6-32 x 3/8 PHP (MS35206-228)                                   All
    Figure 24    9          MS 01513       Screw, 6-32 x 3/8 PHP (MS35206-228)                                   All
    Figure 24   10          MS 01099       Flat Washer, #6 (AN960-6 or NAS1149FN616P)                            All
                            MS 01708       Screw, 8-32 x ½ WHD, Cd Stl (AN525-832R8)
    Figure 24   11                                                                                               All
                          Or MS 01743      Screw, 8-32 x 7/16, PHP (MS35206-244)
    Figure 24   12          OX MI124       Filler Check Valve (MS22066-3)                                        All
    Figure 24   13         102N0450-1      Remote Filler with Pressure Gage Assembly                             All
    Figure 24   14         102N0413-1      Bracket, Remote Filler                                                All
    Figure 24   15          MS 07064       Rivet, Blind (CCR264xS-3-0x)                                          All
    Figure 24   16          MS 01338       Nutplate, 8-32 Floating (MS21059-L08)                                 All
                                                Title Page Rights Apply
                                       FAA Approval Date: _1/31/2017_______                              Page 34 of 36
                                             63354 POWELL BUTTE ROAD                  Document
                                                   BEND, OR 97701                                      102NMAN0003
                                                                                      Number:
                                                    800- 547-2558
                                                  www.preciseflight.com            Revision Number:         G
 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
 Cirrus Design SR22/SR22T Built-In Oxygen System
3.8.1 ALTERNATE FILLER PORT AND LINE INSTALLATION
          See Figure 26
                               2      1
                               3
                       4                                                                          16
               5
          6
 7                                                                                           15
                                                         14
                                                    13
                                   10 11       12
                   8
                           9
                                                Figure 25 - Filler Port Assembly
Table 3
    Fig.      Item     PFI Part Number                               Nomenclature                           Effective
 Figure 25      1        035N1413-1           Bracket, Remote Filler                                           All
                          MS 07084,           Screw, 10-32 x 3/8 WH, Cd Stl (AN525-10R6)
 Figure 25     2          MS 07052,           Screw, 10-32 x ½ PHP, SS (MS51958-63)                             All
                        Or MS 07060           Screw, 10-32 x 7/16 PHP, SS (MS51958-62)
 Figure 25    3           HD 07276            Recept, ¼ Turn, Southco (82-35-295-15 or 82-35-295-20)            All
 Figure 25    4          102N0453-1           Access Panel, Oxygen, Flat Door                                   All
 Figure 25    5          035N0415-1           Door Assembly, Flat - Oxygen Filler                               All
 Figure 25    6          102N0411-2           Access Panel, Modification, wide                                  All
 Figure 25    7                -              See Cirrus IPC for Access Panel Screws                            All
 Figure 25    8           MS 01513            Screw, 6-32 x 3/8 PHP (MS35206-228)                               All
 Figure 25    9           MS 01350            Rivet, 3/32 x ¼ (MS20426AD3-4)                                    All
 Figure 25    10          HD 07277            Bumper, square, silicone (3592K6)                                 All
 Figure 25    11         035N0425-1           Placard, Bumper Locator                                           All
                          MS 01708            Screw, 8-32 x ½ Washer Head (AN525-832R8)
 Figure 25    12                                                                                                All
                        Or MS 01743           Screw, 8-32 x 7/16 PHP (MS35206-244)
 Figure 25    13         OX 020245            Filler Check Valve (MS22066-1)                                    All
 Figure 25    14         035N0210-1           Remote Filler with Pressure Gage Assembly                         All
 Figure 25    15          MS 07064            Rivet, Blind (CCR264xS-3-0x)                                      All
 Figure 25    16          MS 01338            Nutplate, 8-32 Floating (MS21059-L08)                             All
                                                    Title Page Rights Apply
                                           FAA Approval Date: _1/31/2017_______                         Page 35 of 36
                                      63354 POWELL BUTTE ROAD                         Document
                                            BEND, OR 97701                                                102NMAN0003
                                                                                      Number:
                                             800- 547-2558
                                            www.preciseflight.com                  Revision Number:            G
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS – STC SA01708SE
Cirrus Design SR22/SR22T Built-In Oxygen System
                                     Figure 26 - High-Pressure Line Installation
   Fig.     Item   PFI Part Number                           Nomenclature                                      Effective
Figure 26     1      102N0420-1         High Pressure Oxygen Line                                                 All
                          Or            Note: 102N0421-1 replaces 102N0420-1 and 102N0420-2.
                     102N0420-2         Cable tie mounts may need to be relocated for a new line
                          Or            installation.
                     102N0421-1
                                             Title Page Rights Apply
                                 FAA Approval Date: _1/31/2017_______                                      Page 36 of 36