Promass E300
Promass E300
                                Technical Information
                                Proline Promass E 300
                                Coriolis flowmeter
The flowmeter with minimized total cost of ownership and a compact, easily
accessible transmitter
Application                                                    Your benefits
• Measuring principle operates independently of physical       • Cost-effective – multi-purpose device; an alternative to
  fluid properties such as viscosity or density                  conventional volumetric flowmeters
• Accurate measurement of liquids and gases for a wide range   • Fewer process measuring points – multivariable
  of standard applications                                       measurement (flow, density, temperature)
Device properties                                              • Space‐saving installation – no inlet/outlet run needs
• Compact dual-pipe sensor                                     • Full access to process and diagnostic information –
• Medium temperature up to +150 °C (+302 °F)                     numerous, freely combinable I/Os and fieldbuses
• Process pressure up to 100 bar (1 450 psi)                   • Reduced complexity and variety – freely configurable I/O
• Compact dual‐compartment housing with up to 3 I/Os             functionality
• Backlit display with touch control and WLAN access           • Integrated verification – Heartbeat Technology
• Remote display available
                                                                                                                                          Proline Promass E 300
Table of contents
2                                                                                                                                                  Endress+Hauser
Proline Promass E 300
Heartbeat Technology . . . . . . . . . . . . . . . . . . . . . . . . . 86
Concentration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Device-specific accessories . . . . . . . . . . . . . . . . . . . . . .    86
Communication-specific accessories . . . . . . . . . . . . . . . .         87
Service-specific accessories . . . . . . . . . . . . . . . . . . . . . .   88
System components . . . . . . . . . . . . . . . . . . . . . . . . . . .    88
Supplementary documentation . . . . . . . . . . . . . . .                  89
Standard documentation . . . . . . . . . . . . . . . . . . . . . . . . 89
Supplementary device-dependent documentation . . . . . . . 89
Registered trademarks . . . . . . . . . . . . . . . . . . . . . . 90
Endress+Hauser                                                                   3
                                                                                               Proline Promass E 300
               Document information
Symbols used   Electrical symbols
Symbol Meaning
Direct current
Alternating current
                                    Ground connection
                                    A grounded terminal which, as far as the operator is concerned, is grounded via a
                                    grounding system.
                                    Equipotential connection
                                    A connection that has to be connected to the plant grounding system: This may be a
                                    potential equalization line or a star grounding system depending on national or
                                    company codes of practice.
Communication symbols
Symbol Meaning
                                    Bluetooth
                                    Wireless data transmission between devices over a short distance.
                                    LED
                                    Light emitting diode is off.
                                    LED
                                    Light emitting diode is on.
                                    LED
                                    Light emitting diode is flashing.
Symbol Meaning
                                    Permitted
                                    Procedures, processes or actions that are permitted.
                                    Preferred
                                    Procedures, processes or actions that are preferred.
                                    Forbidden
                                    Procedures, processes or actions that are forbidden.
                                    Tip
                                    Indicates additional information.
Reference to documentation
A Reference to page
Reference to graphic
Visual inspection
4                                                                                                       Endress+Hauser
Proline Promass E 300
Symbols in graphics
Symbol Meaning
1. , 2. , 3. … Series of steps
A, B, C, ... Views
                                                 Hazardous area
                                 -
                                                 Safe area (non-hazardous area)
                                 .
                                                 Flow direction
Fc = 2 · ∆m (ν · ω)
Fc = Coriolis force
∆m = moving mass
ω = rotational velocity
                        The amplitude of the Coriolis force depends on the moving mass ∆m, its velocity ν in the system and
                        thus on the mass flow. Instead of a constant rotational velocity ω, the sensor uses oscillation.
                        In the sensor, two parallel measuring tubes containing flowing fluid oscillate in antiphase, acting like
                        a tuning fork. The Coriolis forces produced at the measuring tubes cause a phase shift in the tube
                        oscillations (see illustration):
                        • At zero flow (when the fluid is at a standstill) the two tubes oscillate in phase (1).
                        • Mass flow causes deceleration of the oscillation at the inlet of the tubes (2) and acceleration at the
                           outlet (3).
                                                     1                                  2                        3
                                                                                                                           A0028850
                        The phase difference (A-B) increases with increasing mass flow. Electrodynamic sensors register the
                        tube oscillations at the inlet and outlet. System balance is ensured by the antiphase oscillation of the
                        two measuring tubes. The measuring principle operates independently of temperature, pressure,
                        viscosity, conductivity and flow profile.
Endress+Hauser                                                                                                                  5
                                                                                                         Proline Promass E 300
                   Density measurement
                   The measuring tube is continuously excited at its resonance frequency. A change in the mass and
                   thus the density of the oscillating system (comprising measuring tube and fluid) results in a
                   corresponding, automatic adjustment in the oscillation frequency. Resonance frequency is thus a
                   function of medium density. The microprocessor utilizes this relationship to obtain a density signal.
                   Volume measurement
                   Together with the measured mass flow, this is used to calculate the volume flow.
                   Temperature measurement
                   The temperature of the measuring tube is determined in order to calculate the compensation factor
                   due to temperature effects. This signal corresponds to the process temperature and is also available
                   as an output signal.
Transmitter
Sensor
                   Promass E                              • For standard applications where stable and reliable measurements are
                                                            required
                                                          • Simultaneous measurement of flow, volume flow, density and
                                                            temperature (multivariable)
                                                          • Immune to process influences
                                                          • Nominal diameter range: DN 8 to 80 (³⁄₈ to 3")
                                                          • Materials:
                                               A0026712
                                                            – Sensor: stainless steel, 1.4301 (304)
                                                            – Measuring tubes: stainless steel, 1.4539 (904L)
                                                            – Process connections: stainless steel, 1.4404 (316/316L)
6                                                                                                                 Endress+Hauser
Proline Promass E 300
Equipment architecture
                                                                1
                                   5
                                                     2                                                                 3
                                                                                                                       4
                                   6
A0027512
Safety                   IT security
                         We only provide a warranty if the device is installed and used as described in the Operating
                         Instructions. The device is equipped with security mechanisms to protect it against any inadvertent
                         changes to the device settings.
                         IT security measures in line with operators' security standards and designed to provide additional
                         protection for the device and device data transfer must be implemented by the operators themselves.
                         Device-specific IT security
                         The device offers a range of specific functions to support protective measures on the operator's side.
                         These functions can be configured by the user and guarantee greater in-operation safety if used
                         correctly. An overview of the most important functions is provided in the following section.
Endress+Hauser                                                                                                                    7
                                                                               Proline Promass E 300
    When the device is delivered, the device does not have an access code and is equivalent to 0000
    (open).
    WLAN passphrase
    A connection between an operating unit (e.g. notebook or tablet) and the device via the WLAN
    interface which can be ordered as an option is protected by the network key. The WLAN
    authentication of the network key complies with the IEEE 802.11 standard.
    When the device is delivered, the network key is pre-defined depending on the device. It can be
    changed via the WLAN settings submenu in the WLAN passphrase parameter.
8                                                                                     Endress+Hauser
     Proline Promass E 300
                              Input
     Measured variable        Direct measured variables
                              • Mass flow
                              • Density
                              • Temperature
15 ½ 0 to 6 500 0 to 238.9
25 1 0 to 18 000 0 to 661.5
40 1½ 0 to 45 000 0 to 1 654
50 2 0 to 70 000 0 to 2 573
DN x
8 ³⁄₈ 85
15 ½ 110
25 1 125
40 1½ 125
50 2 125
80 3 155
     Endress+Hauser                                                                                                                         9
                                                                                                     Proline Promass E 300
                      HART protocol
                      The measured values are written from the automation system to the measuring device via the HART
                      protocol. The pressure transmitter must support the following protocol-specific functions:
                      • HART protocol
                      • Burst mode
                      Current input
                      The measured values are written from the automation system to the measuring device via the
                      current input →  10.
                      Digital communication
                      The measured values can be written from the automation system to the measuring via:
                      • FOUNDATION Fieldbus
                      • PROFIBUS PA
                      • Modbus RS485
Resolution 1 µA
10                                                                                                          Endress+Hauser
Proline Promass E 300
Status input
Endress+Hauser                                                                                  11
                                                                                                                             Proline Promass E 300
                                       Output
Output and input variants              Depending on the option selected for output/input 1, different options are available for the other
                                       outputs and inputs. Only one option can be selected for each output/input 1 to 3. The table must be
                                       read vertically (↓).
                                       Example: If the option BA (current output 4 to 20 mA HART) was selected for output/input 1, one of
                                       the options A, B, D, E, F, H, I or J is available for output 2 and one of the options A, B, D, E, F, H, I or
                                       J is available for output 3.
FOUNDATION Fieldbus ↓ SA
FOUNDATION Fieldbus Ex i ↓ TA
PROFIBUS PA ↓ GA
PROFIBUS PA Ex i ↓ HA
Modbus RS485 ↓ MA
Not assigned A A A A A A A
Pulse/frequency/switch output                                                           E                   E                  E                    E
                      2)
Double pulse output                                                                     F                                                           F
Relay output H H H H
Status input J J J J
Not assigned A A A A A A A
Pulse/frequency/switch output E E
Relay output H H
Status input J J
12                                                                                                                                    Endress+Hauser
Proline Promass E 300
Resolution 0.38 µA
                                                    The range of options increases if the measuring device has one or more
                                                     application packages.
PROFIBUS PA
Current consumption 10 mA
FOUNDATION Fieldbus
Current consumption 10 mA
Modbus RS485
Endress+Hauser                                                                                                                13
                                                                                   Proline Promass E 300
Load 0 to 700 Ω
Resolution 0.38 µA
                               The range of options increases if the measuring device has one or more
                                application packages.
Pulse/frequency/switch output
Pulse output
Frequency output
Output frequency Adjustable: end value frequency 2 to 10 000 Hz (f max = 12 500 Hz)
                               The range of options increases if the measuring device has one or more
                                application packages.
Switch output
14                                                                                         Endress+Hauser
Proline Promass E 300
                                                The range of options increases if the measuring device has one or more
                                                 application packages.
                                                The range of options increases if the measuring device has one or more
                                                 application packages.
Relay output
Endress+Hauser                                                                                                            15
                                                                                                 Proline Promass E 300
                                               The range of options increases if the measuring device has one or more
                                                application packages.
Device diagnostics Device condition can be read out via HART Command 48
PROFIBUS PA
FOUNDATION Fieldbus
Modbus RS485
16                                                                                                      Endress+Hauser
Proline Promass E 300
                        4 to 20 mA
                        Failure mode              Choose from:
                                                  • 4 to 20 mA in accordance with NAMUR recommendation NE 43
                                                  • 4 to 20 mA in accordance with US
                                                  • Min. value: 3.59 mA
                                                  • Max. value: 22.5 mA
                                                  • Freely definable value between: 3.59 to 22.5 mA
                                                  • Actual value
                                                  • Last valid value
                        0 to 20 mA
                        Failure mode              Choose from:
                                                  • Maximum alarm: 22 mA
                                                  • Freely definable value between: 0 to 20.5 mA
Pulse/frequency/switch output
Pulse output
Frequency output
Switch output
Relay output
Local display
                        Interface/protocol
                        • Via digital communication:
                          – HART protocol
                          – FOUNDATION Fieldbus
                          – PROFIBUS PA
                          – Modbus RS485
                        • Via service interface
Endress+Hauser                                                                                                 17
                                                                                                       Proline Promass E 300
Web server
26 (+) 27 (–)
18                                                                                                          Endress+Hauser
Proline Promass E 300
26 (+) 27 (–)
                         Option HA                    PROFIBUS PA Ex i              Ex ia 1)                      Ex ic 2)
                                                                                    Ui = 30 V                     Ui = 32 V
                                                                                    li = 570 mA                   li = 570 mA
                                                                                    Pi = 8.5 W                    Pi = 8.5 W
                                                                                    Li = 10 µH                    Li = 10 µH
                                                                                    Ci = 5 nF                     Ci = 5 nF
                         Option G                     Pulse/frequency/switch        Ui = 30 V
                                                      output Ex i                   li = 100 mA
                                                                                    Pi = 1.25 W
                                                                                    Li = 0
                                                                                    Ci = 0
Low flow cut off The switch points for low flow cut off are user-selectable.
Galvanic isolation The outputs are galvanically isolated from one another and from earth (PE).
Manufacturer ID 0x11
Endress+Hauser                                                                                                                                 19
                                                                                        Proline Promass E 300
                                       The range of options increases if the measuring device has one or more
                                        application packages.
                                      Heartbeat Technology Application Package
                                      Additional measured variables are available with the Heartbeat Technology
                                      application package:
                                      Oscillation amplitude 0
PROFIBUS PA
Manufacturer ID 0x11
20                                                                                              Endress+Hauser
Proline Promass E 300
                                                      The range of options increases if the measuring device has one or more
                                                       application packages.
                                                     Heartbeat Technology Application Package
                                                     Additional measured variables are available with the Heartbeat Technology
                                                     application package:
                                                     • Oscillation frequency 0
                                                     • Frequency fluctuation 0
                                                     • Oscillation amplitude 0
                                                     • Oscillation damping 0
                                                     • Oscillation damping fluctuation 0
                                                     • Exciter current 0
Endress+Hauser                                                                                                                   21
                                                                                          Proline Promass E 300
     Compatibility with              If the device is replaced, the Promass 300 measuring device supports the
     earlier model                   compatibility of the cyclic data with earlier models. It is not necessary to
                                     adjust the engineering parameters of the PROFIBUS network with the
                                     Promass 300 GSD file.
                                     Earlier models:
                                     • Promass 80 PROFIBUS PA
                                       – ID No.: 1528 (hex)
                                       – Extended GSD file: EH3x1528.gsd
                                       – Standard GSD file: EH3_1528.gsd
                                     • Promass 83 PROFIBUS PA
                                       – ID No.: 152A (hex)
                                       – Extended GSD file: EH3x152A.gsd
                                       – Standard GSD file: EH3_152A.gsd
FOUNDATION Fieldbus
Manufacturer ID 0x452B48
Device revision 1
Number of VCRs 44
Permanent entries 1
Client VCRs 0
Server VCRs 10
Source VCRs 43
Sink VCRs 0
Subscriber VCRs 43
Publisher VCRs 43
Slot time 4
22                                                                                                Endress+Hauser
Proline Promass E 300
Transducer Blocks
                        Setup Transducer Block All parameters for standard commissioning.           No output values
                        (TRDSUP)
                        Advanced Setup          All parameters for more accurate measurement        No output values
                        Transducer Block        configuration.
                        (TRDASUP)
                        Display Transducer      Parameters for configuring the local display.       No output values
                        Block
                        (TRDDISP)
                        HistoROM Transducer     Parameters for using the HistoROM function.         No output values
                        Block
                        (TRDHROM)
                        Expert Configuration    Parameters that require the user to have in-        No output values
                        Transducer Block        depth knowledge of the operation of the device
                        (TRDEXP)                in order to configure the parameters
                                                appropriately.
                        Expert Information      Parameters that provide information about the       No output values
                        Transducer Block        state of the device.
                        (TRDEXPIN)
                        Service Sensor          Parameters that can only be accessed by Endress No output values
                        Transducer Block        +Hauser Service.
                        (TRDSRVS)
                        Total Inventory         Parameters for configuring all the totalizers and   Process variables (AI Channel)
                        Counter Transducer      the inventory counter.                              • Totalizer 1 (16)
                        Block                                                                       • Totalizer 2 (17)
                        (TRDTIC)                                                                    • Totalizer 3 (18)
                        Heartbeat Results 1     Information about the results of the verification. No output values
                        Transducer Block
                        (TRDHBTR1)
                        Heartbeat Results 2     Information about the results of the verification. No output values
                        Transducer Block
                        (TRDHBTR2)
                        Heartbeat Results 3     Information about the results of the verification. No output values
                        Transducer Block
                        (TRDHBTR3)
                        Heartbeat Results 4     Information about the results of the verification. No output values
                        Transducer Block
                        (TRDHBTR4)
Endress+Hauser                                                                                                                        23
                                                                                           Proline Promass E 300
Function blocks
     PID Block            1       6 ms                                              –
     (PID)
                                                                                     The  compensation
                                                                                      variables must be
                                                                                            transmitted to the device
                                                                                            in the SI basic units.
     Integrator Block     1       6 ms                                              –
     (IT)
24                                                                                                 Endress+Hauser
Proline Promass E 300
Modbus RS485
Data access Each device parameter can be accessed via Modbus RS485.
                        Power supply
Terminal assignment     Transmitter: supply voltage, input/outputs
                        HART
                             Supply voltage           Input/output 1               Input/output 2             Input/output 3
                        FOUNDATION Fieldbus
                             Supply voltage           Input/output 1               Input/output 2             Input/output 3
Endress+Hauser                                                                                                                    25
                                                                                                                       Proline Promass E 300
                              PROFIBUS PA
                                    Supply voltage               Input/output 1                 Input/output 2              Input/output 3
The terminal assignment depends on the specific device version ordered →  12.
                              Modbus RS485
                                    Supply voltage               Input/output 1                 Input/output 2              Input/output 3
The terminal assignment depends on the specific device version ordered →  12.
Device plugs available Device plugs may not be used in hazardous areas!
                              Device plugs are only available for the following device versions:
                              Order code for "Input; output 1"
                              • Option GA "PROFIBUS PA" →  26
                              • Option SA "FOUNDATION Fieldbus" →  26
L, N, P, U Plug M12 × 1 –
M, 3, 4, 5 7/8" plug –
1 4 2 Grounding
3 - PROFIBUS PA –
4 Not assigned
FOUNDATION Fieldbus
1 4 2 - Signal –
3 Grounding
4 Not assigned
26                                                                                                                            Endress+Hauser
Proline Promass E 300
Option D DC 24 V ±20% –
                                                             DC 24 V            ±20%              –
                        Option I
                                                             AC100 to 240 V     –15…+10%          50/60 Hz
                                                            1
                                                            2
                                                            3
A0026781
Endress+Hauser                                                                                                                    27
                                                                                            Proline Promass E 300
                                                                              Gnd
                                                                    Vcc
                                                                                    A   B
                                                                    81 82 83 84
                         1
                         2
                                                                    81 82 83 84
                                                                              Gnd
                                                                                    A   B
                                                                    Vcc
                                   3
A0027518
Connection examples
                    1              2              3
                                                                  4...20 mA
                                                   4                      5
                                                                                                               A0029055
28                                                                                               Endress+Hauser
Proline Promass E 300
1 2 3 4
4...20 mA
A0028762
HART input
1 2 3 4
4...20 mA
                                                                2                   3
                                                                                                                                  A0028763
Endress+Hauser                                                                                                                       29
                                                                                         Proline Promass E 300
PROFIBUS-PA
1 2 3 4
                                                                                                 6
                                                6                 6
                                                                                                 6
                                                                  6
                       8                                                     7
                                                                                                               A0028768
30                                                                                               Endress+Hauser
Proline Promass E 300
FOUNDATION Fieldbus
1 2 3 4
                                                                                                                    6
                                                                   6                 6
                                                                                                                    6
                                                                                     6
                                          8                                                     7
                                                                                                                                  A0028768
Modbus RS485
1 2 3
                                              A                                                                     A
                                                                                                                              4
                                                                                                                    B
                                               B
                                                                                                                    A
                                                                                                                              4
                                                                                                                    B
A0028765
                        7      Connection example for Modbus RS485, non-hazardous area and Zone 2/Div. 2
                        1    Control system (e.g. PLC)
                        2    Cable shield: the cable shield must be grounded at both ends to comply with EMC requirements; observe cable
                             specifications
                        3    Distribution box
                        4    Transmitter
Endress+Hauser                                                                                                                       31
                                                                            Proline Promass E 300
1 2
                                                                                         3
                                                       4...20 mA
                                                                                             A0028758
1 2 3
                                                                                         4
                                                                4...20 mA
A0028759
Pulse/frequency output
1 2
               12345
                                                                                             A0028761
32                                                                               Endress+Hauser
Proline Promass E 300
Switch output
1 2
A0028760
1 3
                                                                                       4
                                                                                               A0029280
                                                                                   2
                                     1                                                 4
                                                                                       5
                                                                                               A0029279
Endress+Hauser                                                                                    33
                                                                                                                Proline Promass E 300
Relay output
1 2
A0028760
Current input
1 2
A0028915
Status input
1 2
A0028764
Terminals                Transmitter
                         Spring terminals for conductor cross-section 0.2 to 2.5 mm2 (24 to 12 AWG)
34                                                                                                                   Endress+Hauser
Proline Promass E 300
Cable entries           • Cable gland: M20 × 1.5 with cable ⌀ 6 to 12 mm (0.24 to 0.47 in)
                        • Thread for cable entry:
                          – NPT ½"
                          – G ½"
                          – M20
                        • Device plug for digital communication: M12
                          Only available for certain device versions →  26.
Signal cable
                        PROFIBUS PA
                        Twisted, shielded two-wire cable. Cable type A is recommended .
                             For further information on planning and installing PROFIBUS PA networks see:
                             • Operating Instructions "PROFIBUS DP/PA: Guidelines for planning and commissioning"
                               (BA00034S)
                             • PNO Directive 2.092 "PROFIBUS PA User and Installation Guideline"
                             • IEC 61158-2 (MBP)
                        FOUNDATION Fieldbus
                        Twisted, shielded two-wire cable.
                             For further information on planning and installing FOUNDATION Fieldbus networks see:
                             • Operating Instructions for "FOUNDATION Fieldbus Overview" (BA00013S)
                             • FOUNDATION Fieldbus Guideline
                             • IEC 61158-2 (MBP)
                        Modbus RS485
                        The EIA/TIA-485 standard specifies two types of cable (A and B) for the bus line which can be used
                        for every transmission rate. Cable type A is recommended.
Cable type A
Signal damping Max. 9 dB over the entire length of the cable cross-section
                        Shield                       Copper braided shielding or braided shielding with foil shield. When grounding
                                                     the cable shield, observe the grounding concept of the plant.
Endress+Hauser                                                                                                                        35
                                                                                         Proline Promass E 300
     Pulse/frequency/switch output
     Standard installation cable is sufficient.
     Relay output
     Standard installation cable is sufficient.
     Status input
     Standard installation cable is sufficient.
Connecting cable for transmitter - remote display and operating module DKX001
     Standard cable
     A standard cable can be used as the connecting cable.
Cable length Maximum 300 m (1 000 ft), see the following table
     Standard cable               2 × 2 × 0.34 mm2 (22 AWG) PVC cable with common shield (2 pairs, pair-
                                  stranded)
     Operating temperature        When mounted in a fixed position: –50 to +105 °C (–58 to +221 °F); when cable
                                  can move freely: –25 to +105 °C (–13 to +221 °F)
36                                                                                                 Endress+Hauser
Proline Promass E 300
                         Performance characteristics
reference operating      •    Error limits based on ISO 11631
conditions               •    Water with +15 to +45 °C (+59 to +113 °F) at2 to 6 bar (29 to 87 psi)
                         •    Specifications as per calibration protocol
                         •    Accuracy based on accredited calibration rigs that are traced to ISO 17025.
                                To obtain measured errors, use the Applicator sizing tool →  88
                         Base accuracy
                                Design fundamentals →  39
Density (liquids)
[g/cm³] [g/cm³]
±0.0005 ±0.02
                         Temperature
                         ±0.5 °C ± 0.005 · T °C (±0.9 °F ± 0.003 · (T – 32) °F)
15 ½ 0.65 0.024
25 1 1.80 0.066
40 1½ 4.50 0.165
50 2 7.0 0.257
80 3 18.0 0.6615
                         Flow values
                         Flow values as turndown parameter depending on nominal diameter.
Endress+Hauser                                                                                                                   37
                                                                                                  Proline Promass E 300
SI units
US units
                Accuracy of outputs
                The outputs have the following base accuracy specifications.
Current output
Accuracy ±5 µA
                Pulse/frequency output
                o.r. = of reading
Accuracy Max. ±50 ppm o.r. (across the entire ambient temperature range)
                Base repeatability
                Mass flow and volume flow (liquids)
                ±0.075 % o.r.
                ±0.05 % o.r. (calibration option, for mass flow)
                Mass flow (gases)
                ±0.35 % o.r.
                     Design fundamentals →  39
                Density (liquids)
                ±0.00025 g/cm3
                Temperature
                ±0.25 °C ± 0.0025 · T °C (±0.45 °F ± 0.0015 · (T–32) °F)
38                                                                                                          Endress+Hauser
Proline Promass E 300
Pulse/frequency output
                        Density
                        When there is a difference between the density calibration temperature and the process
                        temperature, the typical measured error of the sensor is ±0.0001 g/cm3 /°C (±0.00005 g/cm3 /°F).
                        Field density calibration is possible.
                                                   3
                                             [kg/m ]
                                                 14
                                                  12
                                                  10
                                                   8
                                                   6
                                                   4
                                                   2
                                                   0
                                                              -40         0           50          100        150   [°C]
                                                       -80 -40       0    40 80 120 160 200 240 280 320 [°F]
                                                                                                                                   A0016609
                        Temperature
                        ±0.005 · T °C (± 0.005 · (T – 32) °F)
Influence of medium     The table below shows the effect on accuracy of mass flow due to a difference between calibration
pressure                pressure and process pressure.
                        o.r. = of reading
DN [% o.r./bar] [% o.r./psi]
[mm] [in]
8 ³⁄₈ no influence
15 ½ no influence
25 1 no influence
40 1½ no influence
50 2 –0.009 –0.0006
80 3 –0.020 –0.0014
Endress+Hauser                                                                                                                        39
                                                                                                                                Proline Promass E 300
                       ZeroPoint
                     ³ BaseAccu            ⋅ 100                               ± BaseAccu
                                                                                                                                                      A0021339
                                                                   A0021332
                       ZeroPoint                                                   ZeroPoint
                     < BaseAccu ⋅ 100                                              MeasValue ⋅ 100
                                                                               ±
                                                                   A0021333                                                                           A0021334
                        ½ ⋅ ZeroPoint
                    ³    BaseRepeat              ⋅ 100
                                                                                                                                                      A0021340
                                                                   A0021335
                        ½ ⋅ ZeroPoint                                                ZeroPoint
                    <    BaseRepeat              ⋅ 100                         ± ½ ⋅ MeasValue ⋅ 100
                                                                   A0021336                                                                           A0021337
                               E [%]
                         2.5
2.0
1.5
1.0
0.5
                           0
                               0       5    10     15    20   25     30       35   40   45   50   55   60   65   70   75   80   85   90    95 100 Q [%]
A0030289
                    Installation
                    No special measures such as supports etc. are necessary. External forces are absorbed by the
                    construction of the device.
Mounting location
A0028772
40                                                                                                                                        Endress+Hauser
Proline Promass E 300
                        To prevent measuring errors arising from accumulation of gas bubbles in the measuring tube, avoid
                        the following mounting locations in the pipe:
                        • Highest point of a pipeline.
                        • Directly upstream of a free pipe outlet in a down pipe.
A0028773
8 ³⁄₈ 6 0.24
15 ½ 10 0.40
25 1 14 0.55
40 1½ 22 0.87
50 2 28 1.10
80 3 50 1.97
Orientation             The direction of the arrow on the sensor nameplate helps you to install the sensor according to the
                        flow direction (direction of medium flow through the piping).
Orientation Recommendation
A Vertical orientation
A0015591
                                                                                                                                   1)
                            B     Horizontal orientation, transmitter
                                  head up                                                                                Exceptions:
                                                                                                                        →  19,  42
                                                                                                            A0015589
Endress+Hauser                                                                                                                             41
                                                                                                                 Proline Promass E 300
                                                                Orientation                                              Recommendation
                                                                                                                                 2)
                             C      Horizontal orientation, transmitter
                                    head down                                                                              Exceptions:
                                                                                                                          →  19,  42
                                                                                                              A0015590
                        1)       Applications with low process temperatures may decrease the ambient temperature. To maintain the
                                 minimum ambient temperature for the transmitter, this orientation is recommended.
                        2)       Applications with high process temperatures may increase the ambient temperature. To maintain the
                                 maximum ambient temperature for the transmitter, this orientation is recommended.
                        If a sensor is installed horizontally with a curved measuring tube, match the position of the sensor to
                        the fluid properties.
                                             1                                                                           2
                                                                                                                                      A0028774
Inlet and outlet runs   No special precautions need to be taken for fittings which create turbulence, such as valves, elbows
                        or T-pieces, as long as no cavitation occurs →  48.
RUPTURE DISK
A0029956
42                                                                                                                       Endress+Hauser
Proline Promass E 300
                            Experience shows that zero point adjustment is advisable only in special cases:
                            • To achieve maximum measuring accuracy even with low flow rates
                            • Under extreme process or operating conditions (e.g. very high process temperatures or very high-
                              viscosity fluids).
Protective cover
                                                                                   66 (2.6)
                                                     280 (11.0)                                             270 (10.5)
A0029553
                            Environment
Ambient temperature range   Measuring device Non-Ex                 –40 to +60 °C (–40 to +140 °F)
                            ‣ If operating outdoors:
                               Avoid direct sunlight, particularly in warm climatic regions.
Endress+Hauser                                                                                                                            43
                                                                                                                                  Proline Promass E 300
                                     Process
Medium temperature range
                                                                        TA
                                                                                                        A
                                                                                                                    B
                                                                                                                             TF
                                                                                                                                                         A0031121
                                     TA      Ambient temperature
                                     TF      Medium temperature
                                     A       Maximum permitted medium temperature at TA max = 60 °C (140 °F); higher medium temperatures require a
                                             reduction in the ambient temperature TF (derating)
                                     B       Maximum permitted ambient temperature at the maximum specified medium temperature of the sensor
A B A B
TA TF TA TF TA TF TA TF
Promass E 300 60 °C (140 °F) 150 °C (302 °F) – – 60 °C (140 °F) 110 °C (230 °F) 55 °C (131 °F) 150 °C (302 °F)
                                     Seals
                                     No internal seals
44                                                                                                                                       Endress+Hauser
Proline Promass E 300
Pressure-temperature    The following pressure/temperature diagrams apply to all pressure-bearing parts of the device and
ratings                 not just the process connection.
                                     [psi] [bar]
                                            100
                                    1400                  PN 100
                                             90
                                    1200
                                             80
                                    1000     70
                                             60           PN 63
                                      800
                                             50
                                      600    40
                                                          PN 40
                                      400    30
                                             20
                                      200
                                             10
                                        0      0
                                                   -50            0         50     100     150        200 [°C]
                                                    -50     0         50 100 150 200 250 300 350 400 [°F]
                                                                                                                    A0029832-EN
                                     [psi] [bar]
                                            100
                                    1400                  Class 600
                                             90
                                    1200
                                             80
                                    1000     70
                                             60
                                      800                 Class 300
                                             50
                                      600    40
                                      400    30
                                                          Class 150
                                             20
                                      200
                                             10
                                        0      0
                                                   -50            0         50     100     150        200 [°C]
                                                   -50      0         50 100 150 200 250 300 350 400 [°F]
                                                                                                                    A0029833-EN
Endress+Hauser                                                                                                            45
                                                                                Proline Promass E 300
                  [psi] [bar]
                 1000     70
                           60          63K
                   800
                           50
                   600     40
                                       40K
                   400     30
                           20
                   200                 20K
                           10
                                       10K
                     0      0
                                -50           0         50     100       150        200 [°C]
                                 -50      0       50 100 150 200 250 300 350 400 [°F]
                                                                                                  A0029834-EN
                  [psi] [bar]
                          40
                  400     30           DN 8...40
                          20
                  200
                          10           ≥ DN 50
                     0     0
                                -50           0         50     100       150       200 [°C]
                                 -50     0        50 100 150 200 250 300 350 400 [°F]
                                                                                                  A0029839-EN
                  [psi] [bar]
                          50
                  600     40
                                       DN 8…40
                  400     30
                          20           ≥ DN 50
                  200
                          10
                     0     0
                                -50           0         50     100       150       200 [°C]
                                 -50      0       50 100 150 200 250 300 350 400 [°F]
                                                                                                  A0029848-EN
     DIN 11851 allows for applications up to +140 °C (+284 °F) if suitable sealing materials are used.
     Please take this into account when selecting seals and counterparts, as these components can limit
     the pressure and temperature range.
46                                                                                     Endress+Hauser
Proline Promass E 300
                                     [psi] [bar]
                                             50
                                     600     40
                                                          DN 8…40
                                     400     30
                                             20           ≥ DN 50
                                     200
                                             10
                                        0      0
                                                   -50          0         50       100        150       200 [°C]
                                                    -50     0       50 100 150 200 250 300 350 400 [°F]
                                                                                                                        A0029848-EN
                                     [psi] [bar]
                                     400      30
                                              20
                                     200
                                              10
                                        0      0
                                                   -50          0         50       100        150       200 [°C]
                                                    -50     0       50 100 150 200 250 300 350 400 [°F]
                                                                                                                        A0029853-EN
                                     [psi] [bar]
                                              8
                                     100
                                             6
                                      50     2
                                        0      0
                                                   -50          0         50       100        150       200 [°C]
                                                    -50     0       50 100 150 200 250 300 350 400 [°F]
                                                                                                                        A0029862-EN
                        SMS 1145 allows for applications up to 6 bar (87 psi) if suitable sealing materials are used. Please
                        take this into account when selecting seals and counterparts, as these components can limit the
                        pressure and temperature range.
Endress+Hauser                                                                                                                 47
                                                                                                       Proline Promass E 300
VCO
                                       [psi] [bar]
                                              100
                                      1400
                                                90
                                      1200      80
                                      1000      70
                                                     -50        0         50         100       150        200 [°C]
                                                      -50   0       50 100 150 200 250 300 350 400 [°F]
                                                                                                                          A0029863-EN
                        Tri-Clamp
                        The clamp connections are suitable up to a maximum pressure of 16 bar (232 psi). Please observe
                        the operating limits of the clamp and seal used as they can be over 16 bar (232 psi). The clamp and
                        seal are not included in the scope of supply.
Secondary containment   The sensor housing is filled with dry inert gas and protects the electronics and mechanics inside.
pressure rating
                        The housing does not have pressure vessel classification.
                        Reference value for the pressure loading capacity of the sensor housing: 16 bar (232 psi)
                        For information on the dimensions: see the "Mechanical construction -> Accessories" section
Rupture disk            To increase the level of safety, a device version with a rupture disk with a trigger pressure of
                        10 to 15 bar (145 to 217.5 psi) can be used (order code for "Sensor option", option CA "rupture disk").
                        Rupture disks cannot be combined with the separately available heating jacket .
                        Special mounting instructions: →  42
Flow limit              Select the nominal diameter by optimizing between the required flow range and permissible pressure
                        loss.
                               For an overview of the full scale values for the measuring range, see the "Measuring range"
                               section
                        • The minimum recommended full scale value is approx. 1/20 of the maximum full scale value
                        • In most applications, 20 to 50 % of the maximum full scale value can be considered ideal
                        • A low full scale value must be selected for abrasive media (such as liquids with entrained solids):
                          flow velocity < 1 m/s (< 3 ft/s).
                        • For gas measurement the following rules apply:
                          – The flow velocity in the measuring tubes should not exceed half the sound velocity (0.5 Mach).
                          – The maximum mass flow depends on the density of the gas: formula →  9
Pressure loss To calculate the pressure loss, use the Applicator sizing tool →  88
System pressure         It is important that cavitation does not occur, or that gases entrained in the liquids do not outgas.
                        This is prevented by means of a sufficiently high system pressure.
                        For this reason, the following mounting locations are recommended:
                        • At the lowest point in a vertical pipe
                        • Downstream from pumps (no danger of vacuum)
A0028777
48                                                                                                            Endress+Hauser
Proline Promass E 300
Thermal insulation      In the case of some fluids, it is important that the heat radiated from the sensor to the transmitter is
                        kept to a minimum. A wide range of materials can be used for the required insulation.
                         NOTICE
                        Danger of overheating with insulation
                        ‣ Ensure that the temperature at the lower end of the transmitter housing does not exceed
                           80 °C (176 °F)
                         NOTICE
                        The insulation can also be thicker than the maximum recommended insulation thickness.
                        Prerequisite:
                        ‣ Ensure that convection takes place on a sufficiently large scale at the transmitter neck.
                        ‣ Ensure that a sufficiently large area of the housing support remains exposed. The uncovered part
                           serves as a radiator and protects the electronics from overheating and excessive cooling.
                                                                                                      t
                                                                                                      a
A0028853
                        The minimum distance a between the transmitter and the insulation is 10 mm (0.39 in). This is to
                        ensure that the transmitter remains completely exposed.
                        Maximum recommended insulation thickness
                                         t
                                    [in] [mm]
                                     1.5   40
                                           30
                                     1.0
                                           20                                        t40(104)
                                     0.5   10
                                                                    t60(140)
                                       0      0
                                                  80     90          100       110         120        130   140     150 [°C]
                                                                                                                               Tm
                                                              200                               250           290       [°F]
                                                                                                                                    A0028904
                         30       Maximum recommended insulation thickness depending on the temperature of the medium and the
                                   ambient temperature
t Insulation thickness
Tm Medium temperature
Heating                 Some fluids require suitable measures to avoid loss of heat at the sensor.
                        Heating options
                        • Electrical heating, e.g. with electric band heaters
                        • Via pipes carrying hot water or steam
                        • Via heating jackets
                               Heating jackets for the sensors can be ordered as accessories from Endress+Hauser →  86.
Endress+Hauser                                                                                                                         49
                                                                                        Proline Promass E 300
              NOTICE
             Danger of overheating when heating
             ‣ Ensure that the temperature at the lower end of the transmitter housing does not exceed
                80 °C (176 °F).
             ‣ Ensure that convection takes place on a sufficiently large scale at the transmitter neck.
             ‣ Ensure that a sufficiently large area of the housing support remains exposed. The uncovered part
                serves as a radiator and protects the electronics from overheating and excessive cooling.
Vibrations   The high oscillation frequency of the measuring tubes ensures that the correct operation of the
             measuring system is not influenced by plant vibrations.
50                                                                                              Endress+Hauser
Proline Promass E 300
                         Mechanical construction
Dimensions in SI units   Compact version
                                                        A                                         D
                                                   B        C                             E           F
                                                                                                                          I
                                          G
                                                                                                                   K
                                                                                              L
A0029786
                          [mm]         [mm]     [mm]        [mm]   [mm]    [mm]     [mm]          [mm]    [mm]    [mm]    [mm]        [mm]
                                                                                                                                       3)
                              8         200      141         59    169      68       101          5.35    252     341          89
                                                                                                                                       3)
                              15        200      141         59    169      68       101          8.30    252     352         100
                                                                                                                                       3)
                              25        200      141         59    169      68       101          12.0    249     351         102
                                                                                                                                       3)
                              40        200      141         59    169      68       101          17.6    255     376         121
                                                                                                                                       3)
                              50        200      141         59    169      68       101          26.0    269.5   445         175.5
                                                                                                                                       3)
                              80        200      141         59    169      68       101          40.5    288.5   493.5       205
                          [mm]         [mm]     [mm]        [mm]   [mm]    [mm]     [mm]          [mm]    [mm]    [mm]    [mm]        [mm]
                                                                                                                                       3)
                              8         217      159         58    188      85       103          5.35    282     371          89
                                                                                                                                       3)
                              15        217      159         58    188      85       103          8.30    282     382         100
                                                                                                                                       3)
                              25        217      159         58    188      85       103          12.0    279     381         102
                                                                                                                                       3)
                              40        217      159         58    188      85       103          17.6    285     406         121
                                                                                                                                       3)
                              50        217      159         58    188      85       103          26.0    299.5   475         175.5
                                                                                                                                       3)
                              80        217      159         58    188      85       103          40.5    318.5   523.5       205
Endress+Hauser                                                                                                                              51
                                                                                        Proline Promass E 300
      [mm]         [mm]     [mm]     [mm]     [mm]     [mm]     [mm]     [mm]   [mm]     [mm]      [mm]    [mm]
                                                                                                            3)
          8         196      135      61       176      73       103     5.35   251       340       89
                                                                                                            3)
          15        196      135      61       176      73       103     8.30   251       351      100
                                                                                                            3)
          25        196      135      61       176      73       103     12.0   248       350      102
                                                                                                            3)
          40        196      135      61       176      73       103     17.6   254       375      121
                                                                                                            3)
          50        196      135      61       176      73       103     26.0   268.5     444      175.5
                                                                                                            3)
          80        196      135      61       176      73       103     40.5   287.5    492.5     205
52                                                                                               Endress+Hauser
Proline Promass E 300
Flange connections
                                                                 C
                                              A
                                                  B
                                                  E
                                                                  D                                 L
A0015621
                              DN            A             B               C              D             E                L
                             [mm]         [mm]          [mm]            [mm]           [mm]          [mm]             [mm]
Surface roughness (flange): EN 1092-1 Form B1 (DIN 2526 Form C), Ra 3.2 to 12.5 µm
                              DN             A              B                C               D             E              L
                             [mm]          [mm]           [mm]             [mm]            [mm]          [mm]           [mm]
Surface roughness (flange): EN 1092-1 Form B1 (DIN 2526 Form C), Ra 3.2 to 12.5 µm
Endress+Hauser                                                                                                                    53
                                                                                   Proline Promass E 300
           DN             A               B               C               D            E                L
          [mm]          [mm]            [mm]            [mm]            [mm]         [mm]             [mm]
Surface roughness (flange): EN 1092-1 Form B2 (DIN 2526 Form E), Ra 0.8 to 3.2 µm
     Flange with groove according to EN 1092-1 Form D (DIN 2512N) available, PN 100
     1.4404 (F316/F316L)
     Order code for "Process connection", option D8S
           DN             A               B               C               D            E                L
          [mm]          [mm]            [mm]            [mm]            [mm]         [mm]             [mm]
Surface roughness (flange): EN 1092-1 Form B2 (DIN 2526 Form E), Ra 0.8 to 3.2 µm
           DN            A               B                C                   D            E            L
          [mm]         [mm]            [mm]             [mm]                [mm]         [mm]         [mm]
54                                                                                              Endress+Hauser
Proline Promass E 300
                              DN            A               B                C          D       E      L
                             [mm]         [mm]            [mm]             [mm]       [mm]    [mm]   [mm]
                              DN            A               B                C          D       E      L
                             [mm]         [mm]            [mm]             [mm]       [mm]    [mm]   [mm]
                              DN             A               B               C          D       E      L
                             [mm]          [mm]            [mm]            [mm]       [mm]    [mm]   [mm]
8 1) 95 70 4 × Ø15 14 15 232
15 95 70 4 × Ø15 14 15 279
Endress+Hauser                                                                                              55
                                                                        Proline Promass E 300
           DN             A               B              C         D       E            L
          [mm]          [mm]            [mm]           [mm]      [mm]    [mm]         [mm]
           DN             A               B              C         D       E            L
          [mm]          [mm]            [mm]           [mm]      [mm]    [mm]         [mm]
           DN             A               B              C         D       E            L
          [mm]          [mm]            [mm]           [mm]      [mm]    [mm]         [mm]
56                                                                              Endress+Hauser
Proline Promass E 300
X X
                                                                       C
                                                  A
                                                       B
                                                           E
                                                                       D
                                                                                                              L
A0015627
 31 Detail X: Asymmetrical process connection; the part shown in blue is provided by the supplier.
                        Flange DIN11864-2 Form A , for pipe according to DIN11866 series A, flat flange
                        1.4404 (316/316L)
                        Order code for "Process connection", option KCS
                             DN                   A               B                C                 D               E                 L
                            [mm]                [mm]            [mm]             [mm]              [mm]            [mm]              [mm]
8 54 37 4 × Ø9 10 10 249
15 59 42 4 × Ø9 10 16 293
25 70 53 4 × Ø9 10 26 344
40 82 65 4 × Ø9 10 38 456
50 94 77 4 × Ø9 10 50 562
                        3A version available: order code for "Additional approval", option LP in conjunction with
                        Ra ≤ 0.8 µm, order code for "Measuring tube material", option SB
Endress+Hauser                                                                                                                                57
                                                                                             Proline Promass E 300
Clamp connections
Tri-Clamp
                                 B
                                                                                         L
A0015625
     Tri-Clamp (½")
     1.4404 (316/316L)
     Order code for "Process connection", option FDW
             DN                      Clamp                   A                      B                    L
            [mm]                      [in]                 [mm]                   [mm]                 [mm]
     3A version available: order code for "Additional approval", option LP in conjunction with
     Ra ≤ 0.8 µm: order code for "Measuring tube material", option SB
     Ra ≤ 0.4 µm: order code for "Measuring tube material", option SC
     Tri-Clamp ( ≥ 1")
     1.4404 (316/316L)
     Order code for "Process connection", option FTS
             DN                      Clamp                   A                      B                    L
            [mm]                      [in]                 [mm]                   [mm]                 [mm]
     3A version available: order code for "Additional approval", option LP in conjunction with
     Ra ≤ 0.8 µm: order code for "Measuring tube material", option SB
     Ra ≤ 0.4 µm: order code for "Measuring tube material", option SC
58                                                                                                Endress+Hauser
Proline Promass E 300
Cable glands
                                              A
                                                  B
                                                                                                         L
A0015628
                        Threaded hygienic connection DIN 11851, for pipe according to DIN11866, series A
                        1.4404 (316/316L)
                        Order code for "Process connection", option FMW
                                  DN                              A                              B                    L
                                 [mm]                            [in]                          [mm]                 [mm]
8 Rd 34 × ¹⁄₈ 16 229
15 Rd 34 × ¹⁄₈ 16 273
25 Rd 52 × ¹⁄₆ 26 324
40 Rd 65 × ¹⁄₆ 38 456
50 Rd 78 × ¹⁄₆ 50 562
                        3A version available: order code for "Additional approval", option LP in conjunction with
                        Ra ≤ 0.8 µm: order code for "Measuring tube material", option SB
                        Threaded hygienic connection DIN11864-1 Form A, for pipe according to DIN11866, series A
                        1.4404 (316/316L)
                        Order code for "Process connection", option FLW
                                  DN                              A                             B                     L
                                 [mm]                            [in]                         [mm]                  [mm]
8 Rd 28 × ¹⁄₈ 10 229
15 Rd 34 × ¹⁄₈ 16 273
25 Rd 52 × ¹⁄₆ 26 324
40 Rd 65 × ¹⁄₆ 38 456
50 Rd 78 × ¹⁄₆ 50 562
                        3A version available: order code for "Additional approval", option LP in conjunction with
                        Ra ≤ 0.8 µm: order code for "Measuring tube material", option SB
Endress+Hauser                                                                                                                59
                                                                                          Proline Promass E 300
               DN                              A                             B                       L
              [mm]                            [in]                         [mm]                    [mm]
     3A version available: order code for "Additional approval", option LP in conjunction with
     Ra ≤ 0.8 µm: order code for "Measuring tube material", option SB
60                                                                                               Endress+Hauser
Proline Promass E 300
                                              A
                                                  B
                                                                                                         L
A0015623
                        Threaded hygienic connection ISO 2853, for pipe according to ISO 2037
                        1.4404 (316/316L)
                        Order code for "Process connection", option JSF
                                   DN                           A 1)                          B                       L
                                  [mm]                         [mm]                         [mm]                    [mm]
                        3A version available: order code for "Additional approval", option LP in conjunction with
                        Ra ≤ 0.8 µm: order code for "Measuring tube material", option SB
Endress+Hauser                                                                                                                61
                                                                                  Proline Promass E 300
VCO
                              B
                                                                              L
A0015624
     8-VCO-4 (½")
     1.4404 (316/316L)
     Order code for "Process connection", option CVS
                 DN                              A                      B                    L
                [mm]                            [in]                  [mm]                 [mm]
8 AF 1 10.2 252
     12-VCO-4 (¾")
     1.4404 (316/316L)
     Order code for "Process connection", option CWS
                 DN                               A                      B                       L
                [mm]                             [in]                  [mm]                    [mm]
15 AF 1½ 15.7 305
Accessories
                                                                                  7.0 (0.27)
                                                                                                      )
                                                                                                   47
                                                                                             2 (0.
                                                                                          !1
                                    86 (3.39)
A0028921
62                                                                                       Endress+Hauser
Proline Promass E 300
                                                          93 (3.6)   68 (2.7)
                                                             161 (6.3)
A0028923
Endress+Hauser                                                                     63
                                                                                                                      Proline Promass E 300
                                                              A                                       D
                                                          B         C                         E           F
                                                                                                                               I
                                               G
                                                                                                                        K
                                                                                                  L
A0029786
                          [in]          [in]       [in]           [in]   [in]   [in]   [in]        [in]        [in]     [in]       [in]   [in]
                                                                                                                                           3)
                              ³⁄₈      7.87        5.55           2.32   6.65   2.68   3.98       0.211       9.92     13.43       3.5
                                                                                                                                           3)
                              ½        7.87        5.55           2.32   6.65   2.68   3.98       0.33        9.92     13.86       3.94
                                                                                                                                           3)
                              1        7.87        5.55           2.32   6.65   2.68   3.98       0.47         9.8     13.82       4.02
                                                                                                                                           3)
                              1½       7.87        5.55           2.32   6.65   2.68   3.98       0.69        10.04     14.8       4.76
                                                                                                                                           3)
                              2        7.87        5.55           2.32   6.65   2.68   3.98       1.02        10.61    17.52       6.91
                                                                                                                                           3)
                              3        7.87        5.55           2.32   6.65   2.68   3.98       1.59        11.36    19.43       8.07
                          [in]          [in]       [in]           [in]   [in]   [in]   [in]       [in]        [in]      [in]       [in]   [in]
                                                                                                                                           3)
                              ³⁄₈      8.54        6.26           2.28   7.4    3.35   4.06       0.211       11.1     14.61       3.5
                                                                                                                                           3)
                              ½        8.54        6.26           2.28   7.4    3.35   4.06       0.33        11.1     15.04       3.94
                                                                                                                                           3)
                              1        8.54        6.26           2.28   7.4    3.35   4.06       0.47        10.98     15         4.02
                                                                                                                                           3)
                              1½       8.54        6.26           2.28   7.4    3.35   4.06       0.69        11.22    15.98       4.76
                                                                                                                                           3)
                              2        8.54        6.26           2.28   7.4    3.35   4.06       1.02        11.79     18.7       6.91
                                                                                                                                           3)
                              3        8.54        6.26           2.28   7.4    3.35   4.06       1.59        12.54    20.61       8.07
64                                                                                                                             Endress+Hauser
Proline Promass E 300
                          [in]         [in]     [in]    [in]     [in]     [in]     [in]        [in]    [in]    [in]    [in]   [in]
                                                                                                                               3)
                             ³⁄₈      7.72     5.31      2.4     6.93     2.87     4.06        0.211   9.88    13.39   3.5
                                                                                                                               3)
                             ½        7.72     5.31      2.4     6.93     2.87     4.06        0.33    9.88    13.82   3.94
                                                                                                                               3)
                             1        7.72     5.31      2.4     6.93     2.87     4.06        0.47    9.76    13.78   4.02
                                                                                                                               3)
                             1½       7.72     5.31      2.4     6.93     2.87     4.06        0.69     10     14.76   4.76
                                                                                                                               3)
                             2        7.72     5.31      2.4     6.93     2.87     4.06        1.02    10.57   17.48   6.91
                                                                                                                               3)
                             3        7.72     5.31      2.4     6.93     2.87     4.06        1.59    11.32   19.39   8.07
Endress+Hauser                                                                                                                     65
                                                                                 Proline Promass E 300
Flange connections
                                                 C
                               A
                                   B
                                   E
                                                      D                      L
A0015621
          DN             A             B                      C        D            E            L
          [in]          [in]          [in]                  [in]      [in]        [in]         [in]
          DN             A             B                      C        D            E            L
          [in]          [in]          [in]                  [in]      [in]        [in]         [in]
66                                                                                       Endress+Hauser
Proline Promass E 300
                             DN             A             B                   C        D       E      L
                             [in]          [in]          [in]               [in]      [in]   [in]   [in]
Endress+Hauser                                                                                              67
                                                                                             Proline Promass E 300
Clamp connections
Tri-Clamp
                                 B
                                                                                         L
A0015625
     Tri-Clamp (½")
     1.4404 (316/316L)
     Order code for "Process connection", option FDW
            DN                    Clamp                      A                     B                     L
            [in]                   [in]                     [in]                  [in]                 [in]
     3A version available: order code for "Additional approval", option LP in conjunction with
     Ra ≤ 32 µin: order code for "Measuring tube material", option SB
     Ra ≤ 16 µin: order code for "Measuring tube material", option SC
     Tri-Clamp ( ≥ 1")
     1.4404 (316/316L)
     Order code for "Process connection", option FTS
            DN                    Clamp                      A                     B                     L
            [in]                   [in]                     [in]                  [in]                 [in]
     3A version available: order code for "Additional approval", option LP in conjunction with
     Ra ≤ 32 µin: order code for "Measuring tube material", option SB
     Ra ≤ 16 µin: order code for "Measuring tube material", option SC
68                                                                                                Endress+Hauser
Proline Promass E 300
Cable glands
                                              A
                                                  B
                                                                                                         L
A0015628
                                 DN                              A                              B                     L
                                 [in]                           [in]                           [in]                 [in]
                        3A version available: order code for "Additional approval", option LP in conjunction with
                        Ra ≤ 32 µin: order code for "Measuring tube material", option SB
Endress+Hauser                                                                                                                 69
                                                                                 Proline Promass E 300
VCO
                              B
                                                                             L
A0015624
     8-VCO-4 (½")
     1.4404 (316/316L)
     Order code for "Process connection", option CVS
                 DN                               A                    B                        L
                 [in]                            [in]                 [in]                    [in]
     12-VCO-4 (¾")
     1.4404 (316/316L)
     Order code for "Process connection", option CWS
                DN                                A                    B                        L
                [in]                             [in]                 [in]                    [in]
Accessories
                                                                                 7.0 (0.27)
                                                                                                     )
                                                                                                  47
                                                                                            2 (0.
                                                                                         !1
                                    86 (3.39)
A0028921
70                                                                                      Endress+Hauser
Proline Promass E 300
                                                          93 (3.6)   68 (2.7)
                                                              161 (6.3)
A0028923
Weight in SI units
                                           DN                                             Weight [kg]
                                          [mm]
8 2.9
15 3.2
25 4.8
40 8.8
50 13.9
80 29
Weight in US units
                                          DN                                              Weight [lbs]
                                          [in]
3/8 6
½ 7
1 11
1½ 19
2 31
3 64
                        Window material
                        Order code for "Housing":
                        Option A "Aluminum, coated": glass
Endress+Hauser                                                                                              71
                                                                                        Proline Promass E 300
                                         4
                                                                                                              A0028352
Adapter for cable entry with internal thread G ½" Nickel-plated brass
Device plug
     Sensor housing
     • Acid and alkali-resistant outer surface
     • Stainless steel 1.4301 (304)
     Measuring tubes
     Stainless steel, 1.4539 (904L); manifold: stainless steel, 1.4404 (316L)
     Process connections
     • Flanges according to EN 1092-1 (DIN2501) / according to ASME B 16.5 / as per JIS B2220:
       Stainless steel, 1.4404 (F316/F316L)
     • All other process connections:
       Stainless steel, 1.4404 (316/316L)
            List of all available process connections →  73
72                                                                                              Endress+Hauser
Proline Promass E 300
                        Seals
                        Welded process connections without internal seals
Accessories
                        Protective cover
                        Stainless steel, 1.4404 (316L)
                        Operability
Operating concept       Operator-oriented menu structure for user-specific tasks
                        • Commissioning
                        • Operation
                        • Diagnostics
                        • Expert level
                        Fast and safe commissioning
                        • Guided menus ("Make-it-run" wizards) for applications
                        • Menu guidance with brief explanations of the individual parameter functions
                        • Device access via Web server
                        • Optional: WLAN access to device via mobile handheld terminal
                        Reliable operation
                        • Operation in local language →  74
                        • Uniform operating philosophy applied to device and operating tools
                        • If replacing electronic modules, transfer the device configuration via the integrated memory
                          (integrated HistoROM) which contains the process and measuring device data and the event
                          logbook. No need to reconfigure.
Endress+Hauser                                                                                                           73
                                                                                                 Proline Promass E 300
A0026785
                  Display elements
                  •   4-line, illuminated, graphic display
                  •   White background lighting; switches to red in event of device errors
                  •   Format for displaying measured variables and status variables can be individually configured
                  •   Permitted ambient temperature for the display: –20 to +60 °C (–4 to +140 °F)
                      The readability of the display may be impaired at temperatures outside the temperature range.
                  Operating elements
                  • External operation via touch control (3 optical keys) without opening the housing: , , 
                  • Operating elements also accessible in various hazardous areas
74                                                                                                      Endress+Hauser
Proline Promass E 300
A0026786
                        Material
                        The housing material of the display and operating module DKX001 depends on the choice of
                        transmitter housing material.
                        Cable entry
                        Corresponds to the choice of transmitter housing, order code for "Electrical connection".
                        Connecting cable
                        →  36
                        Dimensions
                        →  62
Endress+Hauser                                                                                                                 75
                                                                                     Proline Promass E 300
4 6
                    1                  2                  3                    5
                                                                                                           A0028747
2 3 6 8
                     1                  4                  5                   7
                                                                                                           A0028746
76                                                                                           Endress+Hauser
Proline Promass E 300
1 1 2
                                                                                                          3
                                                                                                          4
                                                                                                          5
                                                                  6                                       6
                                        7          8    9                 7           8       9
                                                                                                              A0028837
1 2
                                                                                                  3
                                                                                                  4
                                                                                                  5
                                                                      6       7
                                                                                                              A0028838
Endress+Hauser                                                                                                   77
                                                                                                       Proline Promass E 300
                                    1                                     2
                                                                                                                              A0029437
A0027563
78                                                                                                             Endress+Hauser
Proline Promass E 300
3 4 1 2 3 4
                                                                                   5             6
                                                                                                                                   A0028839
Configurable channels 1 to 11
Supported operating tools   Different operating tools can be used for local or remote access to the measuring device. Depending
                            on the operating tool used, access is possible with different operating units and via a variety of
                            interfaces.
                            Web browser              Notebook, PC or tablet    • CDI-RJ45 service        Special Documentation for the
                                                     with Web browser            interface               device →  90
                                                                               • WLAN interface
Endress+Hauser                                                                                                                        79
                                                                                                       Proline Promass E 300
                                Other operating tools based on FDT technology with a device driver such as DTM/iDTM or
                                DD/EDD can be used for device operation. These operating tools are available from the
                                individual manufacturers. Integration into the following operating tools, among others, is
                                supported:
                                •   Process Device Manager (PDM) by Siemens → www.siemens.com
                                •   Asset Management Solutions (AMS) by Emerson → www.emersonprocess.com
                                •   FieldCommunicator 375/475 by Emerson → www.emersonprocess.com
                                •   Field Device Manager (FDM) by Honeywell → www.honeywellprocess.com
                                •   FieldMate by Yokogawa → www.yokogawa.com
                                •   PACTWare → www.pactware.com
                                The associated device description files are available at: www.endress.com → Downloads
                           Web server
                           Thanks to the integrated Web server, the device can be operated and configured via a Web browser
                           and via a service interface (CDI-RJ45) or a WLAN interface. The structure of the operating menu is
                           the same as for the local display. In addition to the measured values, status information on the
                           device is also displayed and allows the user to monitor the status of the device. Furthermore the
                           measuring device data can be managed and the network parameters can be configured. The WLAN
                           connection requires a device that acts as an access point to enable communication via a computer or
                           mobile handheld terminal.
                           Supported functions
                           Data exchange between the operating unit (such as a notebook for example) and the measuring
                           device:
                           – Uploading the configuration from the measuring device (XML format, configuration backup)
                           – Save the configuration to the measuring device (XML format, restore configuration)
                           – Export event list (.csv file)
                           – Export parameter settings (.csv file, create documentation of the measuring point configuration)
                           – Export the Heartbeat verification log (PDF file, only available with the "Heartbeat Verification"
                             application package)
                           – Flash firmware version for device firmware upgrade, for instance
HistoROM data management   The measuring device features HistoROM data management. HistoROM data management
                           comprises both the storage and import/export of key device and process data, making operation and
                           servicing far more reliable, secure and efficient.
                                When the device is delivered, the factory settings of the configuration data are stored as a
                                backup in the device memory. This memory can be overwritten with an updated data record, for
                                example after commissioning.
80                                                                                                             Endress+Hauser
Proline Promass E 300
There are different types of data storage units in which device data are stored and used by the device:
                  Device memory                                  T-DAT                                  S-DAT
Available data    •   Event history, such as diagnostic events   • Measured value memory                • Sensor data: diameter etc.
                  •   Parameter data record backup                 ("Extended HistoROM" order           • Serial number
                  •   Device firmware package                      option)                              • User-specific access code (to use the
                  •   Driver for system integration e.g.:        • Current parameter data record          "Maintenance" user role)
                      – DD for HART                                (used by firmware at run time)       • Calibration data
                      – GSD for PROFIBUS PA                      • Maximum indicators (min/max          • Device configuration (e.g. SW options,
                      – DD for FOUNDATION Fieldbus                 values)                                fixed I/O or multi I/O)
                                                                 • Totalizer values
Storage location Fixed on the user interface board in the        Can be plugged into the user interface In the sensor plug in the transmitter neck
                 connection compartment                          board in the connection compartment part
                                      Data backup
                                      Automatic
                                      • The most important device data (sensor and transmitter) are automatically saved in the DAT
                                        modules
                                      • If the transmitter or measuring device is replaced: once the T-DAT containing the previous device
                                        data has been exchanged, the new measuring device is ready for operation again immediately
                                        without any errors
                                      • If the sensor is replaced: once the sensor has been replaced, new sensor data are transferred from
                                        the S-DAT in the measuring device and the measuring device is ready for operation again
                                        immediately without any errors
                                      Manual
                                      Additional parameter data record (complete parameter settings) in the integrated device memory
                                      for:
                                      • Data backup function
                                        Backup and subsequent restoration of a device configuration in the device memory
                                      • Data comparison function
                                        Comparison of the current device configuration with the device configuration saved in the device
                                        memory
                                      Data transfer
                                      Manual
                                      Transfer of a device configuration to another device using the export function of the specific
                                      operating tool, e.g. with FieldCare, DeviceCare or Web server: to duplicate the configuration or to
                                      store in an archive (e.g. for backup purposes)
                                      Event list
                                      Automatic
                                      • Chronological display of up to 20 event messages in the events list
                                      • If the Extended HistoROM application package (order option) is enabled: up to 100 event
                                        messages are displayed in the events list along with a time stamp, plain text description and
                                        remedial measures
                                      • The events list can be exported and displayed via a variety of interfaces and operating tools e.g.
                                        DeviceCare, FieldCare or Web server
                                      Data logging
                                      Manual
                                      If the Extended HistoROM application package (order option) is enabled:
                                      • Record up to 1 000 measured values via 1 to 4 channels
                                      • User configurable recording interval
                                      • Record up to 250 measured values via each of the 4 memory channels
                                      • Export the measured value log via a variety of interfaces and operating tools e.g. FieldCare,
                                         DeviceCare or Web server
                                      • Use the recorded measured value data in the integrated device simulation function in the
                                         Diagnostics submenu.
Endress+Hauser                                                                                                                                     81
                                                                                              Proline Promass E 300
                Service logbook
                Manual
                • Create up to 20 user-specific events with a date and customized text in a separate logbook for
                  documentation of the measuring point
                • Use for calibration or service operations, for example, or for maintenance or revision work that has
                  been performed
C-Tick symbol   The measuring system meets the EMC requirements of the "Australian Communications and Media
                Authority (ACMA)".
Ex approval     The measuring device is certified for use in hazardous areas and the relevant safety instructions are
                provided in the separate "Safety Instructions" (XA) document. Reference is made to this document on
                the nameplate.
                        The separate Ex documentation (XA) containing all the relevant explosion protection data is
                        available from your Endress+Hauser sales center.
                ATEX/IECEx
                Currently, the following versions for use in hazardous areas are available:
                Ex db eb
                                       Category                                      Type of protection
                Ex db
                                       Category                                      Type of protection
                Ex ec
                                       Category                                      Type of protection
                Ex tb
                                       Category                                      Type of protection
CCSAUS
Currently, the following versions for use in hazardous areas are available:
82                                                                                                     Endress+Hauser
Proline Promass E 300
Functional safety            The measuring device can be used for flow monitoring systems (min., max., range) up to SIL 2
                             (single-channel architecture; order code for "Additional approval", option LA) and SIL 3
                             (multichannel architecture with homogeneous redundancy) and is independently evaluated and
                             certified by the TÜV in accordance with IEC 61508.
                             The following types of monitoring in safety equipment are possible:
                             • Mass flow
                             • Volume flow
                             • Density
                                  Functional Safety Manual with information on the SIL device →  89
Modbus RS485 certification   The measuring device meets all the requirements of the MODBUS/TCP conformity test and has the
                             "MODBUS/TCP Conformance Test Policy, Version 2.0". The measuring device has successfully passed
                             all the test procedures carried out.
Endress+Hauser                                                                                                                    83
                                                                                                        Proline Promass E 300
Pressure Equipment         The devices can be ordered with or without a PED approval. If a device with a PED approval is
Directive                  required, this must be explicitly stated in the order. For devices with nominal diameters less than or
                           equal to DN 25 (1"), this is neither possible nor necessary.
                           • With the identification PED/G1/x (x = category) on the sensor nameplate, Endress+Hauser
                             confirms conformity with the "Essential Safety Requirements" specified in Appendix I of the
                             Pressure Equipment Directive 2014/68/EC.
                           • Devices bearing this marking (PED) are suitable for the following types of medium:
                             – Media in Group 1 and 2 with a vapor pressure greater than, or smaller and equal to0.5 bar
                               (7.3 psi)
                             – Unstable gases
                           • Devices not bearing this marking (PED) are designed and manufactured according to good
                             engineering practice. They meet the requirements of Art. 4, Par. 3 of the Pressure Equipment
                             Directive 2014/68/EU. The range of application is indicated in tables 6 to 9 in Annex II of the
                             Pressure Equipment Directive 2014/68/EC.
84                                                                                                              Endress+Hauser
Proline Promass E 300
                        • NAMUR NE 105
                          Specifications for integrating fieldbus devices in engineering tools for field devices
                        • NAMUR NE 107
                          Self-monitoring and diagnosis of field devices
                        • NAMUR NE 131
                          Requirements for field devices for standard applications
                        • NAMUR NE 132
                          Coriolis mass meter
                        • ETSI EN 300 328
                          Guidelines for 2.4 GHz radio components.
                        • EN 301489
                          Electromagnetic compatibility and radio spectrum matters (ERM).
                        Ordering information
                        Detailed ordering information is available from the following sources:
                        • In the Product Configurator on the Endress+Hauser website: www.endress.com -> Click "Corporate"
                          -> Select your country -> Click "Products" -> Select the product using the filters and search field ->
                          Open product page -> The "Configure" button to the right of the product image opens the Product
                          Configurator.
                        • From your Endress+Hauser Sales Center: www.addresses.endress.com
                             Product Configurator - the tool for individual product configuration
                             • Up-to-the-minute configuration data
                             • Depending on the device: Direct input of measuring point-specific information such as
                               measuring range or operating language
                             • Automatic verification of exclusion criteria
                             • Automatic creation of the order code and its breakdown in PDF or Excel output format
                             • Ability to order directly in the Endress+Hauser Online Shop
                        Application packages
                        Many different application packages are available to enhance the functionality of the device. Such
                        packages might be needed to address safety aspects or specific application requirements.
                        The application packages can be ordered with the device or subsequently from Endress+Hauser.
                        Detailed information on the order code in question is available from your local Endress+Hauser sales
                        center or on the product page of the Endress+Hauser website: www.endress.com.
                             Detailed information on the application packages:
                             Special Documentation for the device
                        Extended HistoROM          Comprises extended functions concerning the event log and the activation of the
                                                   measured value memory.
                                                   Event log:
                                                   Memory volume is extended from 20 message entries (standard version) to up to
                                                   100 entries.
                                                   Data logging (line recorder):
                                                   • Memory capacity for up to 1000 measured values is activated.
                                                   • 250 measured values can be output via each of the 4 memory channels. The
                                                     recording interval can be defined and configured by the user.
                                                   • Measured value logs can be accessed via the local display or operating tool e.g.
                                                     FieldCare, DeviceCare or Web server.
Endress+Hauser                                                                                                                          85
                                                                                                                  Proline Promass E 300
                              Accessories
                              Various accessories, which can be ordered with the device or subsequently from Endress+Hauser, are
                              available for the device. Detailed information on the order code in question is available from your
                              local Endress+Hauser sales center or on the product page of the Endress+Hauser website:
                              www.endress.com.
Accessories Description
                              Promass 300 transmitter   Transmitter for replacement or storage. Use the order code to define the following
                                                        specifications:
                                                        • Approvals
                                                        • Output
                                                        • Input
                                                        • Display / operation
                                                        • Housing
                                                        • Software
86                                                                                                                        Endress+Hauser
Proline Promass E 300
                         Remote display and    The remote display and operating module DKX001 is available as an optional extra:
                         operating module      Order code for "Display; operation", option O "Separate backlit, 4-line display;
                         DKX001                10 m (30 ft) Cable; touch control"
                                               The remote display and operating module DKX001 can also be ordered separately
                                               and subsequently as an accessory without a measuring device .
Accessories Description
                         Heating jacket        Is used to stabilize the temperature of the fluids in the sensor.
                                               Water, water vapor and other non-corrosive liquids are permitted for use as fluids.
                                               If using oil as a heating medium, please consult with Endress+Hauser.
                                               Heating jackets cannot be used with sensors fitted with a rupture disk.
                                                BA00371F
                                                 For details, see "Technical Information" TI00429F and Operating Instructions
                         Fieldgate FXA320      Gateway for the remote monitoring of connected 4 to 20 mA measuring devices via
                                               a Web browser.
                                                BA00053S
                                                 For details, see "Technical Information" TI00025S and Operating Instructions
                         Fieldgate FXA520      Gateway for the remote diagnostics and remote configuration of connected HART
                                               measuring devices via a Web browser.
                         Field Xpert SFX350    Field Xpert SFX350 is a mobile computer for commissioning and maintenance. It
                                               enables efficient device configuration and diagnostics for HART and FOUNDATION
                                               Fieldbus devices in the non-Ex area.
Endress+Hauser                                                                                                                   87
                                                                                                              Proline Promass E 300
                               Memograph M graphic   The Memograph M graphic display recorder provides information on all relevant
                               display recorder      measured variables. Measured values are recorded correctly, limit values are
                                                     monitored and measuring points analyzed. The data are stored in the 256 MB
                                                     internal memory and also on a SD card or USB stick.
                                                      BA00247R
                                                       For details, see "Technical Information" TI00133R and Operating Instructions
                               Cerabar M             The pressure transmitter for measuring the absolute and gauge pressure of gases,
                                                     steam and liquids. It can be used to read in the operating pressure value.
                               Cerabar S             The pressure transmitter for measuring the absolute and gauge pressure of gases,
                                                     steam and liquids. It can be used to read in the operating pressure value.
                                                      BA00271P
                                                       For details, see "Technical Information" TI00383P and Operating Instructions
                               iTEMP                 The temperature transmitters can be used in all applications and are suitable for
                                                     the measurement of gases, steam and liquids. They can be used to read in the fluid
                                                     temperature.
88                                                                                                                    Endress+Hauser
Proline Promass E 300
                          Supplementary documentation
                               For an overview of the scope of the associated Technical Documentation, refer to the following:
                               • The W@M Device Viewer : Enter the serial number from the nameplate
                                 (www.endress.com/deviceviewer)
                               • The Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the
                                 2-D matrix code (QR code) on the nameplate.
                          Part 1 of 2: Sensor
                          Measuring device                    Documentation code
                          Part 2 of 2: Transmitter
                                                Documentation code
                                                                     FOUNDATION
                          Measuring device HART                      Fieldbus        PROFIBUS PA          Modbus RS485
Operating Instructions
Documentation code
                                                                     FOUNDATION
                          Measuring device HART                      Fieldbus        PROFIBUS PA          Modbus RS485
ATEX/IECEx Ex ec XA01439D
cCSAus XP XA01373D
cCSAus Ex d/ Ex de XA01372D
cCSAus Ex nA XA01507D
INMETRO Ex ec XA01470D
NEPSI Ex nA XA01471D
Endress+Hauser                                                                                                             89
                                                                                           Proline Promass E 300
ATEX/IECEx Ex i XA01494D
ATEX/IECEx Ex ec XA01498D
cCSAus IS XA01499D
cCSAus Ex nA XA01513D
INMETRO Ex i XA01500D
INMETRO Ex ec XA01501D
NEPSI Ex i XA01502D
NEPSI Ex nA XA01503D
Special documentation
Contents Documentation
Installation Instructions
Installation Instructions for spare part sets Specified for each individual accessory
     Registered trademarks
     HART®
     Registered trademark of the FieldComm Group, Austin, Texas, USA
     PROFIBUS®
     Registered trademark of the PROFIBUS User Organization, Karlsruhe, Germany
     FOUNDATIONTM Fieldbus
     Registration-pending trademark of the FieldComm Group, Austin, Texas, USA
     Modbus®
     Registered trademark of SCHNEIDER AUTOMATION, INC.
     TRI-CLAMP®
     Registered trademark of Ladish & Co., Inc., Kenosha, USA
     Applicator®, FieldCare®, DeviceCare ®, Field XpertTM, HistoROM®, Heartbeat TechnologyTM
     Registered or registration-pending trademarks of the Endress+Hauser Group
90                                                                                                 Endress+Hauser
www.addresses.endress.com