0% found this document useful (0 votes)
212 views2 pages

Fpi BPM-200

The BPM-200 series is an advanced atmospheric dust monitor designed to measure PM10 and PM2.5 particle concentrations using β-ray technology. It features high accuracy, stability, and low maintenance costs, with flexible measurement modes and robust self-check functions. The device is suitable for all-weather operation and supports various communication methods for easy integration and monitoring.

Uploaded by

Vir du1vss
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
212 views2 pages

Fpi BPM-200

The BPM-200 series is an advanced atmospheric dust monitor designed to measure PM10 and PM2.5 particle concentrations using β-ray technology. It features high accuracy, stability, and low maintenance costs, with flexible measurement modes and robust self-check functions. The device is suitable for all-weather operation and supports various communication methods for easy integration and monitoring.

Uploaded by

Vir du1vss
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

BPM-200series

Atmospheric Dust Monitor

■ Product overview
Concentration index of respirable particles is an important
index for air quality. FPI combined years development
experience of environmental and safety testing
instrumentation with the highest demand of domestic and
international users', and used the β-ray technology, to
produce a new generation of BPM-200 series successfully
(atmospheric dust monitor). This monitor has the key “4h” BPM-200series atmospheric dust monitor
features such as high accuracy, high stability, high reliability
and high economy, and can measure atmospheric PM10 ■ Product features
and PM2.5 and other cut size of dust particles. It can be ◆High accuracy, strong anti-interference
widely used for detecting the respirable particles
concentration in atmosphere. ● Using dehumidification and humidity compensation
solutions to cover the impact from raining and high
■ Product principle temperature, all-weather and high-precision measurement;
β-ray method is a recommended method for atmospheric ● Built-in auto-zero calibration and auto-span calibration
dust particles automatic monitor.
function
The instrument uses precise cconstant sampling unit, can
control the volume of sampling air precisely. The suspended
◆Flexible measurement modes and functions
particles in atmosphere are adsorbed by filter paper which
be between β radioactive sources and detectors, and β-rays ● Powerful instrument self-check function, and a thoughtful
also will be absorbed when it passes through the measured examination function of the filter paper,
object, hence, with this β absorption principle, by analyzing
● Can choose the by-pass pipe design, provides artificial
the β intensity before and after absorption to obtain the
atmospheric dust concentration. comparing interface for manual and automatic sampling;

● Supports different time and cycle measurement modes,


sampling probe
the shortest cycle measurement can be set with 10 minutes;

◆Easy maintenance, low maintenance cost


● With the saving paper operation mode and filter paper
replacement reminding function, to reduce the use of filter
sensor sampling pump paper and save costs;

● Rich input and output interfaces and communication


methods, more convenient maintenance

βsource ● Supports wireless (GPRS) and wired communication


method (RS232/485)

flow control unit ● Supports printer;


BPM-200 System structure ● Optional SMS alarm module.
Technical parameters

Measurement index β-ray absorption method


Resolution 0.001 mg/ m 3
Limit of detection 0.001 mg/ m 3
Measurement accuracy ±2%F . S
Measurement range 0~1 mg/ m 3,0~2 mg/ m 3 ,0~5 mg/ m 3, 0~10 mg/ m 3(optional)
Zero drift <1%F . S/10℃
Span drift <1%F . S/10℃
Flow range 0-20L/Min (can be changed )
Flow error ±1%F . S
Capability index
Sampling flow stability ≤±2% flow on point/24h
Reproducibility of the
standard value
calibration film
Power fluctuation influence <2%F . S /20%fluctuating
Sampling cycle 1minutes-360minutes
Dust sampling time 1minutes-300minutes
Count time of sensor 1minutes-30minutes
Time accuracy 0.1%
Source C14radiation source,activity10µCi,exempted source
Typically single volume can be used about 2 months, and with the saving
Technical parameters Glass fiber filter paper belt
paper model, can be used about 3-4 months
Sensor High capability Geiger tube
Communication interface RS232、RS485
2-path analog (4-20mA) output, ;2-path analog1V-5V/0-5V output
2-path analog (4-20mA) input
Interface parameter Input and output
4-path analog output
2-path analog input
Other Serial printer or GPRS module is configurable
Power supply 220V AC±10%,50Hz±1Hz
Features
Total power consumption About 350, with the power supply for vocuum pump and air heating unit
Ambient temperature 0℃~50 ℃
Working condition Ambient humidity 0%~90%RH(non-condensing)
Ambient pressure 86kPa~116 kPa
Instrument dimension (310×430×400) mm(H×W×D)
Other indexes
Instrument weight About 25kg, without accessories

FPIBR-BMP1106100E(杭州印刷)

Focused Photonics(Hang Zhou), Inc.


No.760 Bin’an Road,Binjiang(Hi-tech)District
Hangzhou City,Zhejiang Province,China
Tel:0571-85012188
Fax:0571-85012001
Service hotline:400-7007-555 E-mail:sales_asd@fpi-inc.com
Http://www.fpi-inc.com

You might also like