Concrete Strain Gauge

The document provides specifications for general purpose strain gages in a linear pattern, specifically the C2A-XX-20CLW series with resistances of 120 and 350 ohms. These gages are designed for use on concrete and feature a strain range of ±3% and a temperature range of –60° to +180°F. Additionally, it includes a legal disclaimer regarding product specifications and liabilities.

Uploaded by

furkan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views2 pages

Concrete Strain Gauge

The document provides specifications for general purpose strain gages in a linear pattern, specifically the C2A-XX-20CLW series with resistances of 120 and 350 ohms. These gages are designed for use on concrete and feature a strain range of ±3% and a temperature range of –60° to +180°F. Additionally, it includes a legal disclaimer regarding product specifications and liabilities.

Uploaded by

furkan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

20CLW

General Purpose Strain Gages—Linear Pattern


GAGE PATTERN DATA
GAGE
DESIGNATION RESISTANCE OPTIONS
(OHMS) AVAILABLE
See Note 1

C2A-XX-20CLW-120 120 ± 0.6%


C2A-XX-20CLW-350 350 ± 0.6%

actual size DESCRIPTION


For use on concrete and for strain
integration on large specimens.

Legend inch
GAGE DIMENSIONS ES = Each Section CP = Complete Pattern
S = Section (S1 = Section 1) M = Matrix millimeter

Gage Length Overall Length Grid Width Overall Width Matrix Length Matrix Width
2.000 2.155 0.175 0.175 2.232 0.235
50.80 54.740 4.450 4.450 56.692 5.969

GAGE SERIES DATA — See Gage Series datasheet for complete specifications
Series Description Strain Range Temperature Range
C2A Encapsulated constantan gages with preattached ready-to-use cables. ±3% –60° to +180°F (–50° to +80°C)

Example of a
C2A Construction

Note 1: Insert desired S-T-C number in spaces marked XX.

Document No.: 11256 For technical questions, contact www.micro-measurements.com



Revision: 26-Oct-2015 mm@vpgsensors.com 1
Legal Disclaimer Notice
Vishay Precision Group, Inc.

Disclaimer
ALL PRODUCTS, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE.

Vishay Precision Group, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf
(collectively, “VPG”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in
any other disclosure relating to any product.

The product specifications do not expand or otherwise modify VPG’s terms and conditions of purchase, including but
not limited to, the warranty expressed therein.

VPG makes no warranty, representation or guarantee other than as set forth in the terms and conditions of purchase.
To the maximum extent permitted by applicable law, VPG disclaims (i) any and all liability arising out of the
application or use of any product, (ii) any and all liability, including without limitation special, consequential or
incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose,
non-infringement and merchantability.

Information provided in datasheets and/or specifications may vary from actual results in different applications and
performance may vary over time. Statements regarding the suitability of products for certain types of applications
are based on VPG’s knowledge of typical requirements that are often placed on VPG products. It is the customer’s
responsibility to validate that a particular product with the properties described in the product specification is suitable for
use in a particular application. You should ensure you have the current version of the relevant information by contacting
VPG prior to performing installation or use of the product, such as on our website at vpgsensors.com.

No license, express, implied, or otherwise, to any intellectual property rights is granted by this document, or by any
conduct of VPG.

The products shown herein are not designed for use in life-saving or life-sustaining applications unless otherwise
expressly indicated. Customers using or selling VPG products not expressly indicated for use in such applications do
so entirely at their own risk and agree to fully indemnify VPG for any damages arising or resulting from such use or sale.
Please contact authorized VPG personnel to obtain written terms and conditions regarding products designed for such
applications.

Product names and markings noted herein may be trademarks of their respective owners.

Copyright Vishay Precision Group, Inc., 2014. All rights reserved.

Document No.: 63999 www.vpgsensors.com


Revision: 15-Jul-2014 1

You might also like