Yamada
Yamada
900409E-09
           OPERATION MANUAL
                                         OIL PUMP
              DR-50A1 (DRUM TYPE)                                 ITEM No.852628
              SH-50A1 (SIPHON TYPE)                               ITEM No.852629
                                               WARNING
Prior to operating this pump, be sure to read this operation manual for safety. After reading the manual, please
keep it at hand any time for your quick reference.
                                                                                                                          1/3
- Preface
  Thank you very much for purchasing Yamada Pump. This pump, driven by the compressed air from an air
  compressor, is designed to pump out or transfer lubricant from drum cans or other vessels. The material of the liquid
  contact section of the machine is aluminum alloy (A6061 - T6), and that of the seal section is NBR. Any solvent which
  does not agree to these materials is not available.
                                         This indicates the existence of potential hazard which, if not avoided, will
              WARNING :                  result in death or serious injury.
                                         This indicates the existence of potential hazard which, if not avoided, may
              CAUTION :                  result in bodily injury or in physical damage.
  Furthermore, to indicate the type of danger and damage, the following symbols are also used along with those
  mentioned above:
                This symbol indicates an act that is prohibited (prohibition). The concrete contents of prohibition are
                indicated by the side of the indication.
                This symbol indicates the contents that must be observed. The concrete contents of observance are
                indicated by the side of the indication.
                                                                                                                            2/3
- Precautions on Use
     The following warnings and cautions are very important. Be sure to observe them.
                                                    WARNING
           - Keep your face away from the exhaust and discharge ports. Material may suddenly come out. There is
             a possibility of losing eyesight if it strikes eyes.
           - Gasoline is a high volatile fuel. Do not use it to clean the pump in any case, otherwise ignition or
             explosion may be caused.
- Keep your fingers away from each port to avoid injury from moving parts.
           - Modification of this pump may lead to death, bodily injury, or a failure. Do not modify it in any case
             because it involves a risk.
           - The operator and maintenance engineer should read the operation manual thoroughly before operating
             the pump and performing maintenance in respect of this pump.
           - Always wear proper safety equipments(facemask, ear plugs, and safety shoes, etc.) when installing,
             operating and disassembling the pump.
           - Make ground connection when working with flammable material or in explosive atmosphere. Rapid
             pumping of material can result in static electrical charge.
             Also, be sure to provide proper ventilation where a flammable atmosphere may exist.
           - Attach a valve(for stop in emergency) or regulator to the air supply pipe to keep supply air pressure
             under 0.7 MPa.
           - Discontinue it when you feel a hazard or abnormality during the work. And correspond according to the
             troubleshooting.
           - Stop pump operation immediately when a drum becomes empty. Running the pump dry will cause
             excessive vibration, resulting in reduction of pump life and damage to other equipment.
             Be especially careful when pumping explosive material. Mixture of an air and vaporized material can
             explode. If there is any possibility of running dry, install a dry-run protection device like a liquid level
             control.
           - Before maintenance operation, be sure to stop air from being supplied to the pump, and release the
             internal pressure (both air and material) of the pump. There is danger such as spouting of the material
             when the maintenance work is done with air supplied.
           - Do not discharge material directly onto the ground. Dispose of harmful materials according to the
             requirements specified in SDS or local regulations. Also, dispose of pump according to the local
             regulations after removing residual material from inside pump. (Please contact industrial waste disposal
             service.)
           - (SH type only)If using a wall mount bracket for installation, the wall must be strong enough to withstand
             vibration of the pump.
                                                                                                            3/3
                                         CAUTION
- Keep hands and fingers away from the pump during operation to avoid injury from moving parts.
- Use pump for the material suitable for the specification. Parts may be corroded and material leak from
  the damaged parts can lead to environmental pollution. Also, follow handling notes (SDS) of the
  manufacturer about the handling of the material used.
- Take fall-prevention measures if using a slim or light tank. Risk of falling will be increased due to shift in
  center of gravity caused by change in the material level in a tank.
- Take protective measures against rainwater and dust. It is likely to lead to the pollution of the material.
- Be very careful about the edge of the pump when you lift the pump. Your hands might be injured.
- Be very careful about your posture when installing the pump. Back injury may be caused by lifting the
  pump.
- Do not touch the surfaces of the pump and the hose when pumping high-temperature material. Risk of
  burns exists.
- Stop the air supply source after the end of work when not using this pump for a long time such as
  nighttimes and holidays. Also, open the valve of the exhalation port and liberate pressure in the pump
  and the hose. There is a possibility of polluting facilities because of the damage of the hose and the
  leakage of the valve. Such a secondary disaster becomes a responsibility on the user side.
- (DR type only)Place a drum on a flat, level surface to position pump horizontally against a ground.
  Operating the pump on a slope may cause a fall or tip-over due to shift in center of gravity caused by
  change in the material level.
- (DR type only)Material remaining inside or on the surface of the pump may spill out by inserting or
  removing the pump into/from a drum. Be very careful not to get your clothing dirty.
                                                    Table of Contents
- Preface
- For Safe Operation
- Warnings and Cautions
- Precautions on Use
1.    Names and Materials of Parts
      1.1 Names and Materials of Parts .............................................................................................         1
      1.2 Contents of Package ...........................................................................................................    1
2.    Principle of Operation ........................................................................................................... 1
3.    Installation ....................................................................................................................      1
      3.1 For the Drum Pump .............................................................................................................    2
      3.2 For the Siphon Pump ...........................................................................................................    2
      3.3 Connecting the ground wire .................................................................................................       3
4.    Air Connection ........................................................................................................................ 3
5.    Operating Method ................................................................................................................... 3
6.    Maintenance and Inspection
      6.1 Troubleshooting and Corrective Measures ..........................................................................                 4
      6.2 Maintenance and Inspection ................................................................................................        4
7.    Disassembly and Assembly................................................................................................. 5
8.    Parts Disassembly Drawing and Parts List ..................................................................... 6
9.    Pump Specifications .............................................................................................................. 7
10. Accessary for SH-50A1 (852629) ........................................................................................ 8
11. Limited Warranty .................................................................................................................... 9
1. Names and Materials of Parts
  1.1 Names and Materials of Parts
       [Drum pump]                                              [Siphon pump]
3. Installation
                                                       CAUTION
              - Apply sealing compound or sealing tapes to the male screws and tighten tightly when the pipes are
                connected. Be careful not to allow the sealing materials to enter the piping.
                Do not apply the tip of the terminal (two thread ridges) to maintain conductive property of the ground.
                (However, no applying is necessary if it will be connected to the hose union.)
                Check that there is no leakage or electrical continuity in each part after connecting the piping.
                                                            1
 3.1 For the Drum Pump
 1) Unpack and take out the pump.
 2) Fix the pump with a vise and connect a prepared material hose to its
     discharge port. When this is done, it is recommended to purchase and attach
     a hose union to between the pump and hose. (Fig. 2)
 3) Unplug the inlet port (2”) of the drum can and screw in the bung adapter
     connected to the pump. (Fig. 3)                                                   Fig. 2
 4) Insert the pump into the bung adapter. After the lower end of the pump (foot
     valve section) hits the bottom of the drum, lift the pump by 2 - 3 cm to secure
     a gap between the bottom of the drum and the foot valve. After determining a
     position, tighten a wing bolt of the bung adapter to fix the pump. (Fig. 4)
<NOTE>
 - The procedure is also available for resin type drums. Screw in the upper
   screw of the bung adapter into the drum.                                            Fig. 3
                              CAUTION
              - When using a covered vessel such as a drum can, be
                sure to loosen a vent plug so that the inside of the vessel
                will not be evacuated.
CAUTION Fig. 5
                                                                                        Fig. 6
                                                           2
  3.3 Connecting the ground wire
                                                       WARNING
              - Make ground connection when working with flammable material or in explosive atmosphere. Rapid
                pumping of material can result in static electrical charge. Also, be sure to provide proper ventilation
                where a flammable atmosphere may exist.
  1) When installing the pump, be sure to connect the ground wire at the specified position.
  2) Also connect ground wires to peripheral equipment and piping.
  3) Use 2.0 mm2 minimum ground wire.
                                                       CAUTION
               - In order to use the pump safely and enjoy a long service life, be sure to attach the air regulator to the air
                 supply port. (The air regulator consists of a reducing valve and pressure gauge.)
 <NOTE>
  - If the air has been supplied to the air hose, the pump will be activated the moment it is connected. Prior to
    connecting the air hose to the pump, be sure to turn the knob of the air regulator in the counterclockwise direction.
  - Use of the air regulator allows you to adjust a supply air pressure to the pump, improve operability by reducing
    wasteful movements of the pump, thus prolonging the service life of the pump.
  - The air pressure is increased by turning the knob in the clockwise direction and decreased by turning it in the
    counterclockwise direction.
                                                       CAUTION
               - The supply air pressure to the pump should be 0.7 MPa or less. Do not raise the pressure over 0.7
                 MPa in any case.
               - If the air supplied to the pump is not shut off after completion of the work or at night, the hose may be
                 damaged or leak may occur on the valve or gun, thereby causing a secondary accident. This secondary
                 accident shall be attributable the user’s responsibility.
 <NOTE>
  - The distance for pressure feed differs depending on the viscosity, temperature, and required flow rate of oil.
    Regarding details, please ask YAMADA CORPORATION or the dealer for further information.
  - If the oil in the drum can has be exhausted, the pump is operated at a higher speed without oil and has an adverse
    effect on its life. Stop the pump operation at once and replace the drum can with a new one. For replacing the drum
    can, observe the item pertaining to “3.1 For the Drum Pump”.
5. Operating Method
  1) Turn the knob of the air regulator in the clockwise direction to supply the air into the pump.
  2) If the air is supplied, the pump will be activated for a while, fill the hose and gun with the oil, and stop.
  3) The oil is discharged by operating the lever of the gun at the end of the material hose. Pulling the lever opens the
     valve and automatically activates the pump to discharge the oil. Returning the lever closes the valve and stops a
     discharge and the pump itself simultaneously.
  4) Adjust the supply air pressure in accordance with the purpose of use. Normally, run the pump at the supply air
     pressure of 0.3 - 0.5 MPa. When using the pump to feed-pressure the oil, a discharge rate differs depending on the
     piping distance. Adjust the supply air pressure (up to 0.7 MPa) until your desired discharge rate is obtained.
 <NOTE>
  - When activation of the pump does not stop for a long period time, there may be a leak due to loose connection of
    the hose, piping, gun, etc. or idling due to worm piston packing or valve seat inside the lower pump. Stop an air
    supply and check.
                                                             3
6. Maintenance and Inspection
    6.1 Troubleshooting and Corrective Measures
        Symptom                                      Contents of inspection                        Corrective measure
   The pump fails to start.   - Whether or not the air is properly supplied.                     → Pressure check.
                               - Whether or not the valve halfway the piping is closed              (0.3 - 0.7 MPa)
                                                                  ↓
                               (Remove the material hose from the outlet port on the
                                pump side and activate the pump.)
                               - If activated, the material hose, piping or plumbing is clogged
                                 or an operating pressure is low.
                               - If not activated, the pump is out of order.
                                                                  ↓
                               (Separate the lower pump and activate only the air motor.)
                               - If activated, the lower pump is out of order.                    → Ask for service.
                               - If not activated, the air motor is out of order.                 → Ask for service.
   The pump fails to stop.    - Whether or not there is a leak from the outlet valve (gun).
                               - Whether or not there is a leak from a joint of the piping,
                                 material hose, etc.
                               - Whether or not the drum is running out of the oil.               → Replenish or replace
                                                                  ↓
                               - The lower pump is out of order.                                  → Ask for service.
   The pump is operated       - Whether or not the drum is running out of the oil.               → Replenish or replace
    but does not feed the                                         ↓
    material by pressure.      - The lower pump is out of order.                                  → Ask for service.
   The pump is operated       - Whether or not the supply air pressure has dropped.              → Adjust the pressure.
    but the pressure and                                          ↓                                 (Up to 0.7 MPa)
    flow rate are              - The lower pump is out of order.                                  → Ask for service.
    insufficient.                (Worn valve seat, clogging by dust)
                                                             4
7. Disassembly and Assembly
   When the pump does not function properly or stop, do not hasten to disassemble it. Seeing “6. Maintenance and
   Inspection”, scrutinize the condition and do not disassemble unnecessary parts.
   The air motor does not come into direct contact with the material and hardly goes out of order. You do not have to
   disassemble it. If disassembly is required by any chance, contact our service shop.
                                                        CAUTION
               - Gasoline is a high volatile fuel. Do not use it to clean the pump in any case, otherwise ignition or
                 explosion may be caused.
               - When cleaning pump parts, do not use a liquid that may corrode aluminum, copper ally, iron, etc.
               - Before disassembling and inspecting the machine, be sure to stop the supply air and open the outlet
                 valve to release the internal pressure of the pump.
 <NOTE>
  - The cylinder made of aluminum alloy is vulnerable. Be sure to fix the main
    body with the vise.
  6) By using a pipe wrench on the knurled of the tube. Unscrew the outer
     tube to take it off from the main body.
  7) Remove an O ring from the plunger section, take out a pin, and pull out                         Fig. 8
     a connecting rod. (Fig. 8)
 <NOTE>
  - Take care not to cause the oil remaining in the tube to flow on the floor.
  9) Fix the connecting rod with the vice and unscrew a nut to remove the                   Fig. 9
      valve body and valve seat. (Fig. 9)
  10) Visually check the lip section of the packing inserted into the intake
      valve and replace it if it is worn out or scratched. (Fig.10)
      (When replacing the packing, make sure that the open end of the lip
      faces upward.)
  11) For assembling, reverse the disassembling procedure.
                                                                                                                  Fig.10
                                                             5
8. Parts Disassembly Drawing and Parts List
 ■ 852628 DR-50A1, 852629 SH-50A1
      ■ Parts List
                    Parts No.
      No.                                 Descriptions          Q'ty
               DR-50A1    SH-50A1
       ①        803483              Air motor                    1
       ②        803485     803487   Lower pump                   1
       ③        803488              Bung adapter                 1
       ④        680743              Air plug                     1
                                                                6
 9. Pump specifications
       ■Engineering Data
 NOTE
 The continuous pump operation should be avoided
 if the desired delivery is in the range shaded in the
 figure below.
                                                           7
10. Accessary for SH-50A1 (852629)
■Panel unit
                                                     8
11. Limited Warranty
  If an abnormality occurs during normal operation in accordance with the operating instructions and other operating
  cautions within the warranty period (12 months after date of purchase) that can be attributed to a manufacturing
  defect, the defective parts of this product will be serviced or the product will be replaced free of charge. However, this
  warranty will not cover compensation for incidental damage or any malfunction listed below.
  1. Warranty period
     This warranty will be valid for a period of 12 months after the date of purchase.
  2. Warranty
     If, during the warranty period, any of the material of the genuine parts of this product or the workmanship of this
     product is found defective, and is so verified by our company, the servicing cost will be fully born by our company.
  3. Exclusion
     Even during the warranty period, this warranty does not cover the following.
     1) Malfunction arising from use of parts other than manufacturer-specified genuine parts
     2) Malfunction arising from misuse or operating errors, or lack of storage or maintenance care
     3) Malfunction arising from use with a fluid that may cause corrosion, inflation or dissolution of the component
         parts of the product
     4) Irregularity arising from repair made by other than by our firm, our regional office, dealer or authorized service
         personnel
     5) Malfunction arising from modification of the product by other than authorized service personnel
     6) Wear and tear of parts that must be regularly replaced in the course of normal operation, such as packings,
         O-rings and hose.
     7) Malfunction and/or damage due to use with incorrect voltage.
     8) Malfunction and/or damage due to transportation, moving or drop page of the product after purchase
     9) Malfunction and/or damage due to fire, earthquake, flood or other force majeure
     10) Malfunction arising from use of compressed air that contains impurities or excessive moisture, or use of
         gases or fluids other than the specified compressed air
     11) Malfunction arising from use of excessively abrasive material or of inadequate grease.
     Furthermore, this warranty does not cover the rubber parts, or other parts used in this product and its accessories,
     which are subject to wear in normal operation.
            ・hoses         ・packings ・cords
  4. Parts
     Parts for this product will be kept available for 5 years after discontinuation of production. Once 5 years have
     elapsed after close of production, availability of parts for this product cannot be guaranteed.
                                                            9
YAMADA               CORPORATION
 INTERNATIONAL DEPARTMENT
 1-1-3, Minami-Magome,Ota ku, Tokyo, 143-8504, Japan
 PHONE : +81-(0)3-3777-0241
 FAX     : +81-(0)3-3777-0584
 E-mail : intl@yamadacorp.co.jp
 Web     : www.yamadacorp.co.jp
202101.2517 900409E