0% found this document useful (0 votes)
11 views1 page

Roof

The document contains important construction notes emphasizing that all dimensions must be verified on-site and only written dimensions should be followed. It highlights the need for immediate clarification from architects in case of discrepancies between various drawings and site conditions. Additionally, it specifies that all dimensions are in millimeters and levels in meters, with certain definitions provided for construction terminology.

Uploaded by

dii.s7290uwu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11 views1 page

Roof

The document contains important construction notes emphasizing that all dimensions must be verified on-site and only written dimensions should be followed. It highlights the need for immediate clarification from architects in case of discrepancies between various drawings and site conditions. Additionally, it specifies that all dimensions are in millimeters and levels in meters, with certain definitions provided for construction terminology.

Uploaded by

dii.s7290uwu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

NOTES:

1. ALL DIMENSIONS TO BE CHECKED ON SITE.


2. NO DIMENSION TO BE SCALED OFF FROM THE DRAWINGS,
ONLY WRITTEN DIMENSIONS TO BE FOLLOWED
3. IN THE EVENT OF ANY DISCREPANCIES OR DIFFERENCES
BETWEEN ANY
ARCHITECTURAL DRAWINGS AND STRUCTURAL DRAWINGS
OR OTHER

ENGINEERING DRAWINGS OR SITE CONDITIONS OR


OTHERWISE, IMMEDIATE

REFERENCE IS TO BE MADE TO THE ARCHITECTS FOR


LVL +9 CLARIFICATION
.6M PRIOR TO EXECUTION ON SITE.

ADDITIONAL NOTES:
1. UNLESS SPECIFIED OTHERWISE, ALL DIMENSIONS ARE IN MM
AND ALL LEVELS ARE IN METERS.
2. ALL LEVELS INDICATED ON ARCHITECTURAL DRAWINGS UNLESS

9.6M
LVL +1 OTHERWISE SPECIFIED ARE WITH RESPECT TO FINISHED FLOOR
1.5M LVL +9 LEVELS. FLOOR FINISH THICKNESS SHALL BE 50MM.EXPECT FOR
.6M

LVL +
SUNK AREAS WHICH SHALL HAVE WATERPROOFING
DT 7 TREATMENT.
3. T.O.C MEANS TOP OF CONCRETE.
4. T.O.S MEANS TOP OF SLAB
5. F.F.L MEANS FINISHED FLOOR LEVEL
6. ALL DIMENSIONS MENTIONED ARE UNFINISHED.

LVL +10.2M
LVL +13.8M

RIDG
E LINE

9.6M
LVL +
RIDG
E LIN
LVL +10.2M E

LINE

LVL +9.6M
RIDGE
DT 6 LW-1
LVL +9 LVL +1
.6M 1.5M

LVL +12.5M
RIDGE LINE
LVL +9
.6M

LVL +9.6M
LVL +14.7M

LVL +9.6M
VALLEY LINE

LVL +11.5M
DT 5

LVL +11.5M
LVL +10.2M

LVL +9.6M

LVL +9.6M
LVL +9.6M LVL +9.6M
RIDGE LINE
LVL +11.5M

LVL +10.2M DT 4

LVL +11.5M
DT 3
NO: DATE: 16/04/25 DESCRIPTION BY:
LVL +10.2M
LVL +12.5M

LW-2
REVISIONS
RIDGE LINE
DATE : DRG NO :
16/04/25
VALLEY LINE

RIDGE LINE DRAWN BY: DEEPIGA S PILLAI B-26

LVL +9.6M
CHECKED BY:
15MM THK COPING ON
LVL +10.2M PARAPET WALL

SCALE: 1:100 ROOF PLAN

LVL +10.2M NORTH :

A
DT 1 DT 2
LVL +11.5M LVL +11.5M
NAME AND ADDRESS OF ARCHITECT
LVL +9.6M LVL +9.6M DEEPIGA S PILLAI B-26
L.S.RAHEJA SCHOOL OF ARCHITECTURE, OPP. COLGATE
GROUND,
KHERWADI, BANDRA(EAST), MUMBAI-400051

RCC SLAB ON DUCT @0.8M 15MM THK COPING ON


FROM UFL PARAPET WALL

THIS DRAWING AND DESIGN IS THE SOLE PROPERTY OF LS


RAHEJA SCHOOL OF ARCHITECTURE AND SHALL NOT BE TRACED,
COPIED,REPRODUCED,MODIFIED,LENT OR MADE UNAUTHORISED
USE OF IN ANY OTHER MANNER WITHOUT THE WRITTEN PRIOR
CONSENT OF THE COLLEGE