0% found this document useful (0 votes)
16 views2 pages

9841NH Techdata

The document provides detailed specifications for the RS-485 cable product 9841NH, which features a 24AWG tinned copper conductor, low smoke zero halogen outer jacket, and is suitable for various communication applications in noisy environments. It includes information on construction details, electrical characteristics, mechanical properties, and compliance with environmental and safety standards. The product is available in multiple lengths and is designed for reliable performance in industrial settings.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
16 views2 pages

9841NH Techdata

The document provides detailed specifications for the RS-485 cable product 9841NH, which features a 24AWG tinned copper conductor, low smoke zero halogen outer jacket, and is suitable for various communication applications in noisy environments. It includes information on construction details, electrical characteristics, mechanical properties, and compliance with environmental and safety standards. The product is available in multiple lengths and is designed for reliable performance in industrial settings.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Product: 9841NH

RS-485, 1 Pr #24 Str TC, PO Ins, OS+TC Brd, LSZH Jkt, Dca

Product Description
RS-485, 1 Pair 24AWG (7x32) Tinned Copper, PO Insulation, Overall Beldfoil®+Tinned Copper Braid(90%) Shield, LSZH Outer Jacket, CPR Dca

Technical Specifications

Product Overview

RS-485, POS; Computer communications; Low Voltage Analog Signals (4-20ma, 0-10v, ...); Low Voltage Digital Control (24v, …); Line Level Audio; Panel Wiring; serial
Suitable Applications:
communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, etc.

Construction Details

Conductor

Element No. of Elements Size Stranding Material

Pair(s) 1 24 AWG 7x32 TC - Tinned Copper

Insulation

Element Material Nom. Thickness Nom. Insulation Diameter Color Code

Pair(s) PE - Polyethylene 0.56 mm (0.022 in) 1.73 mm (0.0681 in) White/Blue & Blue/White

Outer Shield

Shield Type Material Coverage Drainwire Type

Tape Bi-Laminate (Alum+Poly) 100% 24 AWG (7x32) TC

Braid Tinned Copper (TC) 90%

Outer Jacket

Material Nom. Thickness Nom. Diameter

LSZH - Low Smoke Zero Halogen (Flame Retardant) 0.9 mm (0.035 in) 6.10 mm (0.240 in)

Overall Cable Diameter 6.10 mm (0.240 in)


(Nominal):

Electrical Characteristics

Electricals

Nom. Capacitance Nom. Capacitance Cond-to-Other (Conds + Nom. Characteristic Nom. Velocity of
Element Nom. Conductor DCR Max. Current
Cond-to-Cond Shield) Impedence Prop.

78.7 Ohm/km (24.0 2.1 Amps per


Pair(s) 42 pF/m (13 pF/ft) 75.5 pF/m 120 Ohm 66%
Ohm/1000ft) Conductor

Nom. Outer Shield DCR: 11.0 Ohm/km (3.35 Ohm/1000ft)

High Frequency (Nominal/Typical)

Element Frequency [MHz] Nom. Insertion Loss (Attenuation)

Pair(s) 1 1.97 dB/100m

Voltage

Voltage Rating

300 V

Mechanical Characteristics
Temperature

Operating Installation Storage

-45°C To +80°C -15°C To +80°C -45°C To +80°C

Bend Radius

Stationary Min. Installation Min.

30 mm (1.2 in) 61 mm (2.4 in)

Max. Pull Tension: 328 N (73.7 lbf)

Bulk Cable Weight: 52 kg/km (35 lbs/1000ft)

Standards and Compliance

Environmental Suitability: Indoor - Euroclass Dca, Indoor, Non-Halogenated, Sunlight Resistance, Oil Resistance

Flammability / Reaction IEC 60332-3-22, IEC 60332-3-24


to Fire:

CPR Compliance: CPR Euroclass: Dca-s2,d1,a1

ISO/IEC Compliance: IEC 61034-2 - Smoke Density Min Transmittance = 60%

CENELEC Compliance: EN 50290-2-20

European Halogen Free IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 - Halogen Amount = Zero, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 2.5 µS/mm, IEC 60754-2 -
Standards: Halogen Acid Gas Amount - Min. pH = 4.3

European Directive EU CE Mark


Compliance:

UK Regulation UKCA Mark


Compliance:

Other Standard DMX-512


Compliance(s):

History

Update and Revision: Revision Number: 0.791 Revision Date: 04-07-2025

Part Numbers

Variants

Item # Color Putup Type Length UPC/EAN Footnote

9841NH.00152 Chrome Reel 152 m 8719605022929

9841NH.00305 Chrome Reel 305 m 8719605022936

9841NH.00500 Chrome Reel 500 m 8719605022943

9841NH 0601000 Chrome Reel 1,000 ft 612825259497 C

9841NH 0601000 Chrome Reel 1,000 ft 612825259497 C

9841NH.001000 Chrome Reel 1,000 m 8719605022912

© 2025 Belden, Inc


All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without
notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and
regulations based on their individual usage of the product.

You might also like